Skip to main content
Top
Published in: Skeletal Radiology 12/2015

01-12-2015 | Scientific Article

Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

Authors: Connie Y. Chang, Ambrose J. Huang, Miriam A. Bredella, Martin Torriani, Elkan F. Halpern, Daniel I. Rosenthal, Dempsey S. Springfield

Published in: Skeletal Radiology | Issue 12/2015

Login to get access

Abstract

Objective

To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate?

Materials and methods

This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson’s χ2 test or Fisher’s exact test.

Results

In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001).

Conclusion

Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign lesion, a non-diagnostic biopsy may be considered reassuring. Frozen pathology may decrease the non-diagnostic biopsy rate.
Literature
1.
go back to reference Dupuy DE, Rosenberg AE, Punyaratabandhu T, Tan MH, Mankin HJ. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol. 1998;171:759–62.CrossRefPubMed Dupuy DE, Rosenberg AE, Punyaratabandhu T, Tan MH, Mankin HJ. Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms. AJR Am J Roentgenol. 1998;171:759–62.CrossRefPubMed
2.
go back to reference Altuntas AO, Slavin J, Smith PJ, Schlict SM, Powell GJ, Ngan S, et al. Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours. ANZ J Surg. 2005;75:187–91.CrossRefPubMed Altuntas AO, Slavin J, Smith PJ, Schlict SM, Powell GJ, Ngan S, et al. Accuracy of computed tomography guided core needle biopsy of musculoskeletal tumours. ANZ J Surg. 2005;75:187–91.CrossRefPubMed
3.
go back to reference Fraser-Hill MA, Renfrew DL. Percutaneous needle biopsy of musculoskeletal lesions, 1: effective accuracy and diagnostic utility. AJR Am J Roentgenol. 1992;158:809–12.CrossRefPubMed Fraser-Hill MA, Renfrew DL. Percutaneous needle biopsy of musculoskeletal lesions, 1: effective accuracy and diagnostic utility. AJR Am J Roentgenol. 1992;158:809–12.CrossRefPubMed
4.
go back to reference Fraser-Hill MA, Renfrew DL, Hilsenrath PE. Percutaneous needle biopsy of musculoskeletal lesions, 2: cost-effectiveness. AJR Am J Roentgenol. 1992;158:813–8.CrossRefPubMed Fraser-Hill MA, Renfrew DL, Hilsenrath PE. Percutaneous needle biopsy of musculoskeletal lesions, 2: cost-effectiveness. AJR Am J Roentgenol. 1992;158:813–8.CrossRefPubMed
5.
go back to reference Pohlig F, Kirchhoff C, Lenze U, Schauwecker J, Burgkart R, Rechl H, et al. Percutaneous core needle biopsy versus open biopsy in diagnostics of bone and soft tissue sarcoma: a retrospective study. Eur J Med Res. 2012;17:29.PubMedCentralCrossRefPubMed Pohlig F, Kirchhoff C, Lenze U, Schauwecker J, Burgkart R, Rechl H, et al. Percutaneous core needle biopsy versus open biopsy in diagnostics of bone and soft tissue sarcoma: a retrospective study. Eur J Med Res. 2012;17:29.PubMedCentralCrossRefPubMed
6.
go back to reference Skrzynski MC, Biermann JS, Montag A, Simon MA. Diagnostic accuracy and charge-savings of outpatient core needle biopsy compared with open biopsy of musculoskeletal tumors. J Bone Joint Surg Am. 1996;78:644–9.PubMed Skrzynski MC, Biermann JS, Montag A, Simon MA. Diagnostic accuracy and charge-savings of outpatient core needle biopsy compared with open biopsy of musculoskeletal tumors. J Bone Joint Surg Am. 1996;78:644–9.PubMed
7.
go back to reference Springfield DS, Rosenberg A. Biopsy: complicated and risky. J Bone Joint Surg Am. 1996;78:639–43.PubMed Springfield DS, Rosenberg A. Biopsy: complicated and risky. J Bone Joint Surg Am. 1996;78:639–43.PubMed
8.
go back to reference Yao L, Nelson SD, Seeger LL, Eckardt JJ, Eilber FR. Primary musculoskeletal neoplasms: effectiveness of core-needle biopsy. Radiology. 1999;212:682–6.CrossRefPubMed Yao L, Nelson SD, Seeger LL, Eckardt JJ, Eilber FR. Primary musculoskeletal neoplasms: effectiveness of core-needle biopsy. Radiology. 1999;212:682–6.CrossRefPubMed
9.
go back to reference Roh J-L, Lee Y-W, Kim J-M. Clinical utility of fine-needle aspiration for diagnosis of head and neck lymphoma. Eur J Surg Oncol. 2008;34:817–21.CrossRefPubMed Roh J-L, Lee Y-W, Kim J-M. Clinical utility of fine-needle aspiration for diagnosis of head and neck lymphoma. Eur J Surg Oncol. 2008;34:817–21.CrossRefPubMed
10.
go back to reference Didolkar MM, Anderson ME, Hochman MG, Rissmiller JG, Goldsmith JD, Gebhardt MG, et al. Image guided core needle biopsy of musculoskeletal lesions: are nondiagnostic results clinically useful? Clin Orthop Relat Res. 2013;471:3601–9.PubMedCentralCrossRefPubMed Didolkar MM, Anderson ME, Hochman MG, Rissmiller JG, Goldsmith JD, Gebhardt MG, et al. Image guided core needle biopsy of musculoskeletal lesions: are nondiagnostic results clinically useful? Clin Orthop Relat Res. 2013;471:3601–9.PubMedCentralCrossRefPubMed
11.
go back to reference Ogilvie CM, Torbert JT, Finstein JL, Fox EJ, Lackman RD. Clinical utility of percutaneous biopsies of musculoskeletal tumors. Clin Orthop Relat Res. 2006;450:95–100.CrossRefPubMed Ogilvie CM, Torbert JT, Finstein JL, Fox EJ, Lackman RD. Clinical utility of percutaneous biopsies of musculoskeletal tumors. Clin Orthop Relat Res. 2006;450:95–100.CrossRefPubMed
12.
go back to reference Potter BK. CORR Insights®: image guided core needle biopsy of musculoskeletal lesions—are nondiagnostic results clinically useful? Clin Orthop Relat Res. 2013;471:3610–1.PubMedCentralCrossRefPubMed Potter BK. CORR Insights®: image guided core needle biopsy of musculoskeletal lesions—are nondiagnostic results clinically useful? Clin Orthop Relat Res. 2013;471:3610–1.PubMedCentralCrossRefPubMed
13.
go back to reference Wu JS, Goldsmith JD, Horwich PJ, Shetty SK, Hochman MG. Bone and soft-tissue lesions: what factors affect diagnostic yield of image-guided core-needle biopsy? Radiology. 2008;248:962–70.CrossRefPubMed Wu JS, Goldsmith JD, Horwich PJ, Shetty SK, Hochman MG. Bone and soft-tissue lesions: what factors affect diagnostic yield of image-guided core-needle biopsy? Radiology. 2008;248:962–70.CrossRefPubMed
14.
go back to reference Yang J, Frassica FJ, Fayad L, Clark DP, Weber KL. Analysis of nondiagnostic results after image-guided needle biopsies of musculoskeletal lesions. Clin Orthop Relat Res. 2010;468:3103–11.PubMedCentralCrossRefPubMed Yang J, Frassica FJ, Fayad L, Clark DP, Weber KL. Analysis of nondiagnostic results after image-guided needle biopsies of musculoskeletal lesions. Clin Orthop Relat Res. 2010;468:3103–11.PubMedCentralCrossRefPubMed
15.
go back to reference Gustafson P, Dreinhöfer KE, Rydholm A. Soft tissue sarcoma should be treated at a tumor center: a comparison of quality of surgery in 375 patients. Acta Orthop Scand. 1994;65:47–50.CrossRefPubMed Gustafson P, Dreinhöfer KE, Rydholm A. Soft tissue sarcoma should be treated at a tumor center: a comparison of quality of surgery in 375 patients. Acta Orthop Scand. 1994;65:47–50.CrossRefPubMed
16.
go back to reference Barman I, Dingari NC, Saha A, McGee S, Galindo LH, Liu W, et al. Application of Raman spectroscopy to identify microcalcifications and underlying breast lesions at stereotactic core needle biopsy. Cancer Res. 2013;73:3206–15.PubMedCentralCrossRefPubMed Barman I, Dingari NC, Saha A, McGee S, Galindo LH, Liu W, et al. Application of Raman spectroscopy to identify microcalcifications and underlying breast lesions at stereotactic core needle biopsy. Cancer Res. 2013;73:3206–15.PubMedCentralCrossRefPubMed
17.
go back to reference Choi SH, Chae EJ, Kim J-E, Kim EY, Oh SY, Hwang HJ, et al. Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1 cm: analysis of outcomes of 305 procedures from a tertiary referral center. AJR Am J Roentgenol. 2013;201:964–70.CrossRefPubMed Choi SH, Chae EJ, Kim J-E, Kim EY, Oh SY, Hwang HJ, et al. Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1 cm: analysis of outcomes of 305 procedures from a tertiary referral center. AJR Am J Roentgenol. 2013;201:964–70.CrossRefPubMed
19.
go back to reference Adams J, Wu HH. The utility of fine-needle aspiration in the diagnosis of primary and metastatic tumors to the lung: a retrospective examination of 1,032 cases. Acta Cytol. 2012;56:590–5.CrossRefPubMed Adams J, Wu HH. The utility of fine-needle aspiration in the diagnosis of primary and metastatic tumors to the lung: a retrospective examination of 1,032 cases. Acta Cytol. 2012;56:590–5.CrossRefPubMed
20.
go back to reference Londoño DC, Wuerstle MC, Thomas AA, Salazar LE, Hsu J-WY, Danial T, et al. Accuracy and implications of percutaneous renal biopsy in the management of renal masses. Perm J. 2013;17:4–7.PubMedCentralCrossRefPubMed Londoño DC, Wuerstle MC, Thomas AA, Salazar LE, Hsu J-WY, Danial T, et al. Accuracy and implications of percutaneous renal biopsy in the management of renal masses. Perm J. 2013;17:4–7.PubMedCentralCrossRefPubMed
21.
go back to reference Park SY, Park BK, Kim CK, Kwon GY. Ultrasound-guided core biopsy of small renal masses: diagnostic rate and limitations. J Vasc Interv Radiol. 2013;24:90–6.CrossRefPubMed Park SY, Park BK, Kim CK, Kwon GY. Ultrasound-guided core biopsy of small renal masses: diagnostic rate and limitations. J Vasc Interv Radiol. 2013;24:90–6.CrossRefPubMed
22.
go back to reference Dedhia PH, Rubio GA, Cohen MS, Miller BS, Gauger PG, Hughes DT. Potential effects of molecular testing of indeterminate thyroid nodule fine needle aspiration biopsy on thyroidectomy volume. World J Surg. 2014 Dedhia PH, Rubio GA, Cohen MS, Miller BS, Gauger PG, Hughes DT. Potential effects of molecular testing of indeterminate thyroid nodule fine needle aspiration biopsy on thyroidectomy volume. World J Surg. 2014
23.
go back to reference Tatomirovic Z, Skuletic V, Bokun R, Trimcev J, Radic O, Cerovic S, et al. Fine needle aspiration cytology in the diagnosis of head and neck masses: accuracy and diagnostic problems. J BUON. 2009;14:653–9.PubMed Tatomirovic Z, Skuletic V, Bokun R, Trimcev J, Radic O, Cerovic S, et al. Fine needle aspiration cytology in the diagnosis of head and neck masses: accuracy and diagnostic problems. J BUON. 2009;14:653–9.PubMed
24.
go back to reference Fung AD, Collins JA, Campassi C, Ioffe OB, Staats PN. Performance characteristics of ultrasound-guided fine-needle aspiration of axillary lymph nodes for metastatic breast cancer employing rapid on-site evaluation of adequacy: analysis of 136 cases and review of the literature. Cancer Cytopathol. 2013 Fung AD, Collins JA, Campassi C, Ioffe OB, Staats PN. Performance characteristics of ultrasound-guided fine-needle aspiration of axillary lymph nodes for metastatic breast cancer employing rapid on-site evaluation of adequacy: analysis of 136 cases and review of the literature. Cancer Cytopathol. 2013
25.
go back to reference Mahony GT, Mahony BS. Low nondiagnostic rate for fine-needle capillary sampling biopsy of thyroid nodules: a singular experience. J Ultrasound Med. 2013;32:2155–61.CrossRefPubMed Mahony GT, Mahony BS. Low nondiagnostic rate for fine-needle capillary sampling biopsy of thyroid nodules: a singular experience. J Ultrasound Med. 2013;32:2155–61.CrossRefPubMed
26.
go back to reference Zhao H, Xie Z, Zhou Z-L, Sui X-Z, Wang J. Diagnostic value of endobronchial ultrasound-guided transbronchial needle aspiration in intrapulmonary lesions. Chin Med J. 2013;126:4312–5.PubMed Zhao H, Xie Z, Zhou Z-L, Sui X-Z, Wang J. Diagnostic value of endobronchial ultrasound-guided transbronchial needle aspiration in intrapulmonary lesions. Chin Med J. 2013;126:4312–5.PubMed
27.
go back to reference Odejide OO, Cronin AM, DeAngelo DJ, Bernazzoli ZA, Jacobson JO, Rodig SJ, et al. Improving the quality of bone marrow assessment: impact of operator techniques and use of a specimen preparation checklist. Cancer. 2013;119:3472–8.PubMed Odejide OO, Cronin AM, DeAngelo DJ, Bernazzoli ZA, Jacobson JO, Rodig SJ, et al. Improving the quality of bone marrow assessment: impact of operator techniques and use of a specimen preparation checklist. Cancer. 2013;119:3472–8.PubMed
28.
go back to reference Hunter S, Samir A, Eisner B, Gervais D, Maher M, Hahn P, et al. Diagnosis of renal lymphoma by percutaneous image guided biopsy: experience with 11 cases. J Urol. 2006;176:1952–6. discussion 1956.CrossRefPubMed Hunter S, Samir A, Eisner B, Gervais D, Maher M, Hahn P, et al. Diagnosis of renal lymphoma by percutaneous image guided biopsy: experience with 11 cases. J Urol. 2006;176:1952–6. discussion 1956.CrossRefPubMed
29.
go back to reference Na DG, Kim J, Sung JY, Baek JH, Jung KC, Lee H, et al. Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid. 2012;22:468–75.CrossRefPubMed Na DG, Kim J, Sung JY, Baek JH, Jung KC, Lee H, et al. Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid. 2012;22:468–75.CrossRefPubMed
30.
go back to reference Simsek GG, Ertuğrul DT, Guresci S, Şimşek H. Is there a role for on-site evaluation of thyroid fine needle aspiration to reduce the nondiagnostic rate? Endocr Pathol. 2013;24:57–61.CrossRefPubMed Simsek GG, Ertuğrul DT, Guresci S, Şimşek H. Is there a role for on-site evaluation of thyroid fine needle aspiration to reduce the nondiagnostic rate? Endocr Pathol. 2013;24:57–61.CrossRefPubMed
31.
go back to reference Cermak TS, Wang B, DeBrito P, Carroll J, Haddad N, Sidawy MK. Does on-site adequacy evaluation reduce the nondiagnostic rate in endoscopic ultrasound-guided fine-needle aspiration of pancreatic lesions? Cancer Cytopathol. 2012;120:319–25.CrossRefPubMed Cermak TS, Wang B, DeBrito P, Carroll J, Haddad N, Sidawy MK. Does on-site adequacy evaluation reduce the nondiagnostic rate in endoscopic ultrasound-guided fine-needle aspiration of pancreatic lesions? Cancer Cytopathol. 2012;120:319–25.CrossRefPubMed
32.
go back to reference Virayavanich W, Ringler MD, Chin CT, Baum T, Giaconi JC, O’Donnell RJ, et al. CT-guided biopsy of bone and soft-tissue lesions: role of on-site immediate cytologic evaluation. J Vasc Interv Radiol. 2011;22:1024–30.CrossRefPubMed Virayavanich W, Ringler MD, Chin CT, Baum T, Giaconi JC, O’Donnell RJ, et al. CT-guided biopsy of bone and soft-tissue lesions: role of on-site immediate cytologic evaluation. J Vasc Interv Radiol. 2011;22:1024–30.CrossRefPubMed
33.
go back to reference Salomao M, Remotti H, Allendorf JD, Poneros JM, Sethi A, Gonda TA, et al. Fine-needle aspirations of pancreatic serous cystadenomas: improving diagnostic yield with cell blocks and α-inhibin immunohistochemistry. Cancer Cytopathol. 2014;122:33–9.CrossRefPubMed Salomao M, Remotti H, Allendorf JD, Poneros JM, Sethi A, Gonda TA, et al. Fine-needle aspirations of pancreatic serous cystadenomas: improving diagnostic yield with cell blocks and α-inhibin immunohistochemistry. Cancer Cytopathol. 2014;122:33–9.CrossRefPubMed
34.
go back to reference Deonizio JMD, Guitart J. The role of molecular analysis in cutaneous lymphomas. Semin Cutan Med Surg. 2012;31:234–40.CrossRefPubMed Deonizio JMD, Guitart J. The role of molecular analysis in cutaneous lymphomas. Semin Cutan Med Surg. 2012;31:234–40.CrossRefPubMed
35.
go back to reference Anderson MD, Abel TW, Moots PL. Re-evaluation of nondiagnostic biopsies of suspected low-grade glioma using isocitrate dehydrogenase 1 mutation immunohistochemistry. Neuro-Oncology. 2013;15:811–3.PubMedCentralCrossRefPubMed Anderson MD, Abel TW, Moots PL. Re-evaluation of nondiagnostic biopsies of suspected low-grade glioma using isocitrate dehydrogenase 1 mutation immunohistochemistry. Neuro-Oncology. 2013;15:811–3.PubMedCentralCrossRefPubMed
36.
go back to reference Nielsen JA, Lager DJ, Lewin M, Weber JJ, Roberts CA. Incidence of diagnostic change in colorectal polyp specimens after deeper sectioning at 2 different laboratories staffed by the same pathologists. Am J Clin Pathol. 2013;140:231–7.CrossRefPubMed Nielsen JA, Lager DJ, Lewin M, Weber JJ, Roberts CA. Incidence of diagnostic change in colorectal polyp specimens after deeper sectioning at 2 different laboratories staffed by the same pathologists. Am J Clin Pathol. 2013;140:231–7.CrossRefPubMed
37.
go back to reference Li QK, Nugent SL, Straseski J, Cooper D, Riedel S, Askin FB, et al. Thyroglobulin measurements in fine-needle aspiration cytology of lymph nodes for the detection of metastatic papillary thyroid carcinoma. Cancer Cytopathol. 2013;121:440–8.CrossRefPubMed Li QK, Nugent SL, Straseski J, Cooper D, Riedel S, Askin FB, et al. Thyroglobulin measurements in fine-needle aspiration cytology of lymph nodes for the detection of metastatic papillary thyroid carcinoma. Cancer Cytopathol. 2013;121:440–8.CrossRefPubMed
38.
go back to reference Brenner RJ, Fajardo L, Fisher PR, Dershaw DD, Evans WP, Bassett L, et al. Percutaneous core biopsy of the breast: effect of operator experience and number of samples on diagnostic accuracy. AJR Am J Roentgenol. 1996;166:341–6.CrossRefPubMed Brenner RJ, Fajardo L, Fisher PR, Dershaw DD, Evans WP, Bassett L, et al. Percutaneous core biopsy of the breast: effect of operator experience and number of samples on diagnostic accuracy. AJR Am J Roentgenol. 1996;166:341–6.CrossRefPubMed
Metadata
Title
Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies
Authors
Connie Y. Chang
Ambrose J. Huang
Miriam A. Bredella
Martin Torriani
Elkan F. Halpern
Daniel I. Rosenthal
Dempsey S. Springfield
Publication date
01-12-2015
Publisher
Springer Berlin Heidelberg
Published in
Skeletal Radiology / Issue 12/2015
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-015-2235-0

Other articles of this Issue 12/2015

Skeletal Radiology 12/2015 Go to the issue