Skip to main content
Top
Published in: Skeletal Radiology 3/2011

01-03-2011 | Scientific Article

Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system

Authors: Helen Anderson, Andoni Paul Toms, John G. Cahir, Richard W. Goodwin, James Wimhurst, John F. Nolan

Published in: Skeletal Radiology | Issue 3/2011

Login to get access

Abstract

Introduction

Metal-on-metal (MoM) soft tissue reactions or aseptic lymphocytic vasculitis-associated lesions (ALVAL) are being recognised using metal artefact reduction (MAR) MR with increasing frequency following the advent of second generation metal-on-metal bearings, but there is no standardised technique for reporting of MR appearances in this disease. The aim of this study was to measure the reliability of a grading system designed for scoring the severity of MoM disease on MRI.

Materials and methods

MRI examinations of 73 hips in 59 patients were retrospectively selected and then anonymised, randomised and reviewed by three independent observers (musculoskeletal radiologists). Each MR examination was scored as either A: normal, B: infection, C1: mild MoM disease, C2: moderate MoM disease or C3: severe MoM disease according to pre-defined criteria. Kappa correlation statistics were used to compare the observations.

Results

There was substantial agreement among all three observers; the correlation coefficient between the two most experienced observers was κ = 0.78 [95% confidence intervals (CI): 0.68–0.88] and when compared with the least experienced observer coefficients were κ = 0.69 (95% CI: 0.57–0.80) and κ = 0.66 (95% CI: 0.54–0.78). The strongest correlation occurred for grades A, C2 and C3. The weakest correlations occurred for grades B and C1.

Conclusion

The grading system described in this study is reliable for evaluating ALVAL in MoM prostheses using MR but is limited in differentiating mild disease from infection.
Literature
1.
go back to reference Park Y, Moon Y, Lim S, Yang J, Ahn G, Choi Y. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am. 2005;87(7):1515–21.CrossRefPubMed Park Y, Moon Y, Lim S, Yang J, Ahn G, Choi Y. Early osteolysis following second-generation metal-on-metal hip replacement. J Bone Joint Surg Am. 2005;87(7):1515–21.CrossRefPubMed
2.
go back to reference McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br. 1966;48(2):245–59.PubMed McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg Br. 1966;48(2):245–59.PubMed
3.
go back to reference August AC, Aldam CH, Pynsent PB. The McKee-Farrar hip arthroplasty. A long-term study. J Bone Joint Surg Br. 1986;68(4):520–7.PubMed August AC, Aldam CH, Pynsent PB. The McKee-Farrar hip arthroplasty. A long-term study. J Bone Joint Surg Br. 1986;68(4):520–7.PubMed
4.
go back to reference Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 1972;54(1):61–76.PubMed Charnley J. The long-term results of low-friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg Br. 1972;54(1):61–76.PubMed
5.
go back to reference Schmalzried TP, Peters PC, Maurer BT, Bragdon CR, Harris WH. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. J Arthroplasty. 1996;11(3):322–31.CrossRefPubMed Schmalzried TP, Peters PC, Maurer BT, Bragdon CR, Harris WH. Long-duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces. J Arthroplasty. 1996;11(3):322–31.CrossRefPubMed
6.
go back to reference Saito S, Ryu J, Watanabe M, Ishii T, Saigo K. Midterm results of Metasul metal-on-metal total hip arthroplasty. J Arthroplasty. 2006;21(8):1105–10.CrossRefPubMed Saito S, Ryu J, Watanabe M, Ishii T, Saigo K. Midterm results of Metasul metal-on-metal total hip arthroplasty. J Arthroplasty. 2006;21(8):1105–10.CrossRefPubMed
7.
go back to reference Müller ME. The benefits of metal-on-metal total hip replacements. Clin Orthop Relat Res. 1995;(311):54-59. Müller ME. The benefits of metal-on-metal total hip replacements. Clin Orthop Relat Res. 1995;(311):54-59.
8.
go back to reference Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty. 2004;19(8 Suppl 3):78–83.CrossRefPubMed Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP. Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty. 2004;19(8 Suppl 3):78–83.CrossRefPubMed
9.
go back to reference Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am. 2005;87(1):18–27.CrossRefPubMed Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am. 2005;87(1):18–27.CrossRefPubMed
10.
go back to reference Willert H, Buchhorn GH, Fayyazi A, Flury R, Windler M, Köster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Jt Surg Am. 2005;87(1):28–36.CrossRef Willert H, Buchhorn GH, Fayyazi A, Flury R, Windler M, Köster G, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Jt Surg Am. 2005;87(1):28–36.CrossRef
11.
go back to reference Cahir JG, Toms AP, Marshall TJ, Wimhurst J, Nolan J. CT and MRI of hip arthroplasty. Clin Radiol. 2007;62(12):1163–71. discussion 1172-1173.CrossRefPubMed Cahir JG, Toms AP, Marshall TJ, Wimhurst J, Nolan J. CT and MRI of hip arthroplasty. Clin Radiol. 2007;62(12):1163–71. discussion 1172-1173.CrossRefPubMed
12.
go back to reference Lee MJ, Janzen DL, Munk PL, MacKay A, Xiang QS, McGowen A. Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom. Skeletal Radiol. 2001;30(7):398–401.CrossRefPubMed Lee MJ, Janzen DL, Munk PL, MacKay A, Xiang QS, McGowen A. Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom. Skeletal Radiol. 2001;30(7):398–401.CrossRefPubMed
13.
go back to reference Chang SD, Lee MJ, Munk PL, Janzen DL, MacKay A, Xiang QS. MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence. Skeletal Radiol. 2001;30(4):213–8.CrossRefPubMed Chang SD, Lee MJ, Munk PL, Janzen DL, MacKay A, Xiang QS. MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence. Skeletal Radiol. 2001;30(4):213–8.CrossRefPubMed
14.
go back to reference Gruber FW, Böck A, Trattnig S, Lintner F, Ritschl P. Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J Arthroplasty. 2007;22(6):923–7.CrossRefPubMed Gruber FW, Böck A, Trattnig S, Lintner F, Ritschl P. Cystic lesion of the groin due to metallosis: a rare long-term complication of metal-on-metal total hip arthroplasty. J Arthroplasty. 2007;22(6):923–7.CrossRefPubMed
15.
go back to reference Toms AP, Nolan J, Barker T, Darrah C, Malcolm P. Early failure of a Birmingham resurfacing hip replacement with lymphoreticular spread of metal debris: pre-operative diagnosis with MR. Br J Radiol. 2009;82(977):e87–91.CrossRefPubMed Toms AP, Nolan J, Barker T, Darrah C, Malcolm P. Early failure of a Birmingham resurfacing hip replacement with lymphoreticular spread of metal debris: pre-operative diagnosis with MR. Br J Radiol. 2009;82(977):e87–91.CrossRefPubMed
16.
go back to reference Toms AP, Marshall TJ, Cahir J, Darrah C, Nolan J, Donell ST, et al. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips. Clin Radiol. 2008;63(1):49–58.CrossRefPubMed Toms AP, Marshall TJ, Cahir J, Darrah C, Nolan J, Donell ST, et al. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips. Clin Radiol. 2008;63(1):49–58.CrossRefPubMed
17.
go back to reference Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CLM, et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008;90(7):847–51.CrossRefPubMed Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gibbons CLM, et al. Pseudotumours associated with metal-on-metal hip resurfacings. J Bone Joint Surg Br. 2008;90(7):847–51.CrossRefPubMed
18.
go back to reference Hart AJ, Sabah S, Henckel J, Lewis A, Cobb J, Sampson B, et al. The painful metal-on-metal hip resurfacing. J Bone Joint Surg Br. 2009;91(6):738–44.CrossRefPubMed Hart AJ, Sabah S, Henckel J, Lewis A, Cobb J, Sampson B, et al. The painful metal-on-metal hip resurfacing. J Bone Joint Surg Br. 2009;91(6):738–44.CrossRefPubMed
19.
go back to reference Toms AP, Kasmai B, Williams S, Wilson P. Building an anonymized catalogued radiology museum in PACS: a feasibility study. Br J Radiol. 2006;79(944):666–71.CrossRefPubMed Toms AP, Kasmai B, Williams S, Wilson P. Building an anonymized catalogued radiology museum in PACS: a feasibility study. Br J Radiol. 2006;79(944):666–71.CrossRefPubMed
21.
go back to reference Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17(3):205–16.CrossRefPubMed Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging. 2004;17(3):205–16.CrossRefPubMed
22.
go back to reference Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159–74.CrossRefPubMed Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159–74.CrossRefPubMed
Metadata
Title
Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system
Authors
Helen Anderson
Andoni Paul Toms
John G. Cahir
Richard W. Goodwin
James Wimhurst
John F. Nolan
Publication date
01-03-2011
Publisher
Springer-Verlag
Published in
Skeletal Radiology / Issue 3/2011
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-010-1000-7

Other articles of this Issue 3/2011

Skeletal Radiology 3/2011 Go to the issue