Skip to main content
Top
Published in: Skeletal Radiology 4/2010

01-04-2010 | Scientific Article

Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults

Authors: Arun Mullaji, Gautam M. Shetty, Raj Kanna, Amit Sharma

Published in: Skeletal Radiology | Issue 4/2010

Login to get access

Abstract

Purpose

The anterior superior iliac spine (ASIS) is commonly used to estimate the centre of the femoral head and assess limb alignment during surgical procedures. This study aimed to determine the range of inter-anterior superior iliac spine distances (IADs) and inter-femoral head centre distances (IFDs) among individuals and ascertain whether there is correlation between the IFD and the IAD. We also sought to determine whether gender, height and body mass index (BMI) had any influence on IAD and IFD.

Materials and methods

We prospectively measured IAD and IFD in 200 adults, using transverse computed tomography (CT) scans done for medical causes. We also calculated the distance between the pelvic midline and the centre of the femoral head (XY distance) from the measured IFD. The influence of gender, height and body-mass index on IAD and IFD, and the correlation of IAD with IFD, were also studied.

Results

The overall mean IAD, IFD and XY distances were 22.7 ± 1.6 cm, 16.0 ± 0.8 cm and 8.0 ± 0.4 cm, respectively. There was wide variation within the IAD range with 50% (100/200) of the subjects having their IAD within ±10 mm of the mean compared to 75.5% (151/200) of the subjects with IFD within ±10 mm of the mean. The probability that the mean XY distance would fall within 10 mm of the true femoral head centre in all subjects was 100%. The gender difference in IAD and IFD was statistically significant (P = 0.03 and P < 0.001, respectively), height and BMI had no influence, and the correlation of IAD with IFD was weak (0.35).

Conclusion

Although the range of IADs showed wide variation among subjects, this study clearly demonstrated the narrow range of the XY distance and IFD in the study population and provides a useful and accurate basis for a new method to determine the femoral head centre clinically and intraoperatively.
Literature
1.
go back to reference Hooper G, Leslie H, Burn J, Schouten R, Beci I. Oblique upper tibial opening wedge osteotomy for genu varum. Oper Orthop Traumatol. 2005;17:662–73.CrossRefPubMed Hooper G, Leslie H, Burn J, Schouten R, Beci I. Oblique upper tibial opening wedge osteotomy for genu varum. Oper Orthop Traumatol. 2005;17:662–73.CrossRefPubMed
2.
go back to reference Seidel GK, Marchinda DM, Dijkers M, Soutas-Little RW. Hip joint centre location from palpable bony landmarks: a cadaver study. J Biomech. 1995;28:995–8.CrossRefPubMed Seidel GK, Marchinda DM, Dijkers M, Soutas-Little RW. Hip joint centre location from palpable bony landmarks: a cadaver study. J Biomech. 1995;28:995–8.CrossRefPubMed
3.
go back to reference Purkait R, Chandra H. A study of sexual variation in Indian femur. Forensic Sci Int. 2004;146:25–33.CrossRefPubMed Purkait R, Chandra H. A study of sexual variation in Indian femur. Forensic Sci Int. 2004;146:25–33.CrossRefPubMed
4.
go back to reference Sawant MR, Murty A, Ireland J. A clinical method for locating the femoral head centre during total knee arthroplasty. Knee. 2004;11:209–12.CrossRefPubMed Sawant MR, Murty A, Ireland J. A clinical method for locating the femoral head centre during total knee arthroplasty. Knee. 2004;11:209–12.CrossRefPubMed
5.
go back to reference Ritter MA, Campbell ED. A model for easy location of the centre of the femoral head during total knee arthroplasty. J Arthroplasty. 1988;3(Suppl):S59–61.CrossRefPubMed Ritter MA, Campbell ED. A model for easy location of the centre of the femoral head during total knee arthroplasty. J Arthroplasty. 1988;3(Suppl):S59–61.CrossRefPubMed
6.
go back to reference Horton GA, Reckling FW. Femoral pulse as a guide to the mechanical axis in total knee arthroplasty. J Arthroplasty. 1995;10:780–4.CrossRefPubMed Horton GA, Reckling FW. Femoral pulse as a guide to the mechanical axis in total knee arthroplasty. J Arthroplasty. 1995;10:780–4.CrossRefPubMed
7.
go back to reference Matsuda Y, Ishii Y, Ichimura K. Identifying the centre of the femoral head using ultrasonography to assess the higher accuracy of femoral extramedullary guides in TKA. J Orthop Sci. 2004;9:6–9.CrossRefPubMed Matsuda Y, Ishii Y, Ichimura K. Identifying the centre of the femoral head using ultrasonography to assess the higher accuracy of femoral extramedullary guides in TKA. J Orthop Sci. 2004;9:6–9.CrossRefPubMed
8.
go back to reference Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop. 1983;173:178–83.PubMed Bargren JH, Blaha JD, Freeman MA. Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop. 1983;173:178–83.PubMed
9.
go back to reference Denham RA, Bishop RE. Mechanics of the knee and problems in reconstructive surgery. J Bone Joint Surg Br. 1978;60:345–52.PubMed Denham RA, Bishop RE. Mechanics of the knee and problems in reconstructive surgery. J Bone Joint Surg Br. 1978;60:345–52.PubMed
Metadata
Title
Variability in the range of inter-anterior superior iliac spine distance and its correlation with femoral head centre. A prospective computed tomography study of 200 adults
Authors
Arun Mullaji
Gautam M. Shetty
Raj Kanna
Amit Sharma
Publication date
01-04-2010
Publisher
Springer-Verlag
Published in
Skeletal Radiology / Issue 4/2010
Print ISSN: 0364-2348
Electronic ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-009-0791-x

Other articles of this Issue 4/2010

Skeletal Radiology 4/2010 Go to the issue