Skip to main content
Top
Published in: Pediatric Radiology 12/2023

29-09-2023 | Arthrography | Original Article

Frequency of technical success of ultrasound-guided arthrogram injections in children

Authors: Joseph O’Sullivan, Helen H. R. Kim, Jeffrey P. Otjen, Anh-Vu Ngo, Ezekiel Maloney, Sarah J. Menashe, Ramesh S. Iyer, Mahesh Thapa

Published in: Pediatric Radiology | Issue 12/2023

Login to get access

Abstract

Background

MR arthrography is an essential diagnostic tool to assess and guide management of labral, ligamentous, fibrocartilaginous, and capsular abnormalities in children. While fluoroscopy is traditionally used for intra-articular contrast administration, ultrasound offers advantages of portability and lack of ionizing radiation exposure for both the patient and proceduralist.

Objective

The purpose of this retrospective study is to quantify technical success and frequency of complications of ultrasound-guided arthrogram injections at our institution.

Materials and methods

This retrospective analysis investigates the results of 217 ultrasound-guided arthrograms of the shoulder, elbow, and hip in patients aged 5–18 years. Successful injection of contrast into the target joint, clinical indication for MR arthrography, and complications were reviewed.

Results

Accurate ultrasound-guided intra-articular administration of contrast into the target joint was successful for 100% of shoulder cases (90/90), 97% of elbow cases (77/79), and 98% of hip cases (47/48). Leak of contrast outside the target joint occurred in 1.4% (3/217) of cases. No major side effects including excessive bleeding, paresthesia, allergic reactions, or infection occurred during or after the procedure. Additionally, no major vessel, nerve, or tendon complications were observed on MR images.

Conclusion

Ultrasound guidance is a reliable, effective, and safe approach to arthrography in children.

Graphical Abstract

Appendix
Available only for authorised users
Literature
1.
go back to reference Magee T (2009) 3-T MRI of the shoulder: is MR arthrography necessary? Am J Roentgenol 192:86–92CrossRef Magee T (2009) 3-T MRI of the shoulder: is MR arthrography necessary? Am J Roentgenol 192:86–92CrossRef
2.
3.
go back to reference Choudur HN, Lou EM (2011) Ultrasound-guided gadolinium joint injections for magnetic resonance arthrography. J Clin Ultrasound 39:6–11CrossRefPubMed Choudur HN, Lou EM (2011) Ultrasound-guided gadolinium joint injections for magnetic resonance arthrography. J Clin Ultrasound 39:6–11CrossRefPubMed
5.
go back to reference Otjen J, Parnell SE, Menashe S, Thapa MM (2015) Ultrasound-guided joint injections for MR arthrography in pediatric patients: how we do it. Pediatr Radiol 45:308–316CrossRefPubMed Otjen J, Parnell SE, Menashe S, Thapa MM (2015) Ultrasound-guided joint injections for MR arthrography in pediatric patients: how we do it. Pediatr Radiol 45:308–316CrossRefPubMed
7.
go back to reference Schulte-Altedorneburg G, Gebhard M, Wohlgemuth WA et al (2003) MR arthrography: pharmacology, efficacy and safety in clinical trials. Skeletal Radiol 32:1–12CrossRefPubMed Schulte-Altedorneburg G, Gebhard M, Wohlgemuth WA et al (2003) MR arthrography: pharmacology, efficacy and safety in clinical trials. Skeletal Radiol 32:1–12CrossRefPubMed
8.
go back to reference Shortt CP, Morrison WB, Roberts CC et al (2009) Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America. Skeletal Radiol 38:377–385CrossRefPubMed Shortt CP, Morrison WB, Roberts CC et al (2009) Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America. Skeletal Radiol 38:377–385CrossRefPubMed
9.
go back to reference Kuratani K, Tanaka M, Hanai H, Hayashida K (2022) Accuracy of shoulder joint injections with ultrasound guidance: confirmed by magnetic resonance arthrography. World J Orthop 13:259–266CrossRefPubMedPubMedCentral Kuratani K, Tanaka M, Hanai H, Hayashida K (2022) Accuracy of shoulder joint injections with ultrasound guidance: confirmed by magnetic resonance arthrography. World J Orthop 13:259–266CrossRefPubMedPubMedCentral
10.
go back to reference Ali AH, Said HG, Abo elhamd E et al (2021) Shoulder MR arthrography: comparative evaluation of three different contrast injection techniques using an anterior approach. J Magn Reson Imaging 53:481–490CrossRefPubMed Ali AH, Said HG, Abo elhamd E et al (2021) Shoulder MR arthrography: comparative evaluation of three different contrast injection techniques using an anterior approach. J Magn Reson Imaging 53:481–490CrossRefPubMed
11.
go back to reference Martínez-Martínez A, García-Espinosa J, Ruiz-Santiago F et al (2016) Comparison of ultrasound and fluoroscopic guidance for injection in CT arthrography and MR arthrography of the hip. Radiología (English Edition) 58:454–459CrossRef Martínez-Martínez A, García-Espinosa J, Ruiz-Santiago F et al (2016) Comparison of ultrasound and fluoroscopic guidance for injection in CT arthrography and MR arthrography of the hip. Radiología (English Edition) 58:454–459CrossRef
12.
go back to reference Rutten MJCM, Collins JMP, Maresch BJ et al (2009) Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography. Eur Radiol 19:722–730CrossRefPubMed Rutten MJCM, Collins JMP, Maresch BJ et al (2009) Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography. Eur Radiol 19:722–730CrossRefPubMed
13.
go back to reference Ng AWH, Hung EHY, Griffith JF et al (2013) Comparison of ultrasound versus fluorcoscopic guided rotator cuff interval approach for MR arthrography. Clin Imaging 37:548–553CrossRefPubMed Ng AWH, Hung EHY, Griffith JF et al (2013) Comparison of ultrasound versus fluorcoscopic guided rotator cuff interval approach for MR arthrography. Clin Imaging 37:548–553CrossRefPubMed
14.
go back to reference Perdikakis E, Drakonaki E, Maris T, Karantanas A (2013) MR arthrography of the shoulder: tolerance evaluation of four different injection techniques. Skeletal Radiol 42:99–105CrossRefPubMed Perdikakis E, Drakonaki E, Maris T, Karantanas A (2013) MR arthrography of the shoulder: tolerance evaluation of four different injection techniques. Skeletal Radiol 42:99–105CrossRefPubMed
15.
go back to reference Byrd JWT, Potts EA, Allison RK, Jones KS (2014) Ultrasound-guided hip injections: a comparative study with fluoroscopy-guided injections. Arthroscopy - J Arthrosc Related Surg 30:42–46CrossRef Byrd JWT, Potts EA, Allison RK, Jones KS (2014) Ultrasound-guided hip injections: a comparative study with fluoroscopy-guided injections. Arthroscopy - J Arthrosc Related Surg 30:42–46CrossRef
16.
go back to reference Chopra A, Grainger AJ, Dube B et al (2018) Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip. Eur Radiol 28:963–971CrossRefPubMed Chopra A, Grainger AJ, Dube B et al (2018) Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip. Eur Radiol 28:963–971CrossRefPubMed
17.
go back to reference Crespo-Rodríguez AM, De Lucas-Villarrubia JC, Pastrana-Ledesma M et al (2017) The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement. Eur J Radiol 88:109–116CrossRefPubMed Crespo-Rodríguez AM, De Lucas-Villarrubia JC, Pastrana-Ledesma M et al (2017) The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement. Eur J Radiol 88:109–116CrossRefPubMed
18.
go back to reference Zhang P, Li C, Wang W, Zhang B, Miao W, Liu Y (2022) 3.0 T MRI is more recommended to detect acetabular labral tears than MR Arthrography: an updated meta-analysis of diagnostic accuracy. J Orthop Surg Res 17(1):126 Zhang P, Li C, Wang W, Zhang B, Miao W, Liu Y (2022) 3.0 T MRI is more recommended to detect acetabular labral tears than MR Arthrography: an updated meta-analysis of diagnostic accuracy. J Orthop Surg Res 17(1):126
19.
go back to reference Magee T (2015) Accuracy of 3-T MR arthrography versus conventional 3-T MRI of elbow tendons and ligaments compared with surgery. AJR Am J Roentgenol 204:W70–W75CrossRefPubMed Magee T (2015) Accuracy of 3-T MR arthrography versus conventional 3-T MRI of elbow tendons and ligaments compared with surgery. AJR Am J Roentgenol 204:W70–W75CrossRefPubMed
20.
go back to reference Major NM, Browne J, Domzalski T et al (2011) Evaluation of the glenoid labrum with 3-T MRI: Is intraarticular contrast necessary? Am J Roentgenol 196:1139–1144CrossRef Major NM, Browne J, Domzalski T et al (2011) Evaluation of the glenoid labrum with 3-T MRI: Is intraarticular contrast necessary? Am J Roentgenol 196:1139–1144CrossRef
23.
go back to reference Patel DN, Nayyar S, Hasan S et al (2012) Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study. J Shoulder Elbow Surg 21:1664–1668CrossRefPubMed Patel DN, Nayyar S, Hasan S et al (2012) Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study. J Shoulder Elbow Surg 21:1664–1668CrossRefPubMed
24.
go back to reference Furtado RNV, Pereira DF, da Luz KR et al (2013) Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound. Revista Brasileira de Reumatologia (English Edition) 53:476–482CrossRef Furtado RNV, Pereira DF, da Luz KR et al (2013) Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound. Revista Brasileira de Reumatologia (English Edition) 53:476–482CrossRef
Metadata
Title
Frequency of technical success of ultrasound-guided arthrogram injections in children
Authors
Joseph O’Sullivan
Helen H. R. Kim
Jeffrey P. Otjen
Anh-Vu Ngo
Ezekiel Maloney
Sarah J. Menashe
Ramesh S. Iyer
Mahesh Thapa
Publication date
29-09-2023
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 12/2023
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-023-05777-5

Other articles of this Issue 12/2023

Pediatric Radiology 12/2023 Go to the issue

Hermes

Hermes