Skip to main content
Top
Published in: Pediatric Radiology 12/2017

Open Access 01-11-2017 | Letter to the Editor

Lack of evidence of a relationship between magnetic resonance signal intensity changes in the globus pallidus and dentate nucleus, and repeated administrations of gadoterate meglumine in children

Authors: Eric Lancelot, Jean-Sébastien Raynaud, Pierre Desché

Published in: Pediatric Radiology | Issue 12/2017

Login to get access

Excerpt

Dear Editors, …
Literature
1.
go back to reference Rossi Espagnet CA, Bernardi B, Pasquini L et al (2017) Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children. Pediatr Radiol. doi:10.1007/s00247-017-3874-1 Rossi Espagnet CA, Bernardi B, Pasquini L et al (2017) Signal intensity at unenhanced T1-weighted magnetic resonance in the globus pallidus and dentate nucleus after serial administrations of a macrocyclic gadolinium-based contrast agent in children. Pediatr Radiol. doi:10.​1007/​s00247-017-3874-1
2.
go back to reference Hu HH, Pokorney A, Towbin RB et al (2016) Increased signal intensities in the dentate nucleus and globus pallidus on unenhanced T1-weighted images: evidence in children undergoing multiple gadolinium MRI exams. Pediatr Radiol 46:1590–1598CrossRefPubMed Hu HH, Pokorney A, Towbin RB et al (2016) Increased signal intensities in the dentate nucleus and globus pallidus on unenhanced T1-weighted images: evidence in children undergoing multiple gadolinium MRI exams. Pediatr Radiol 46:1590–1598CrossRefPubMed
3.
go back to reference Flood TF, Stence NV, Maloney JA et al (2017) Pediatric brain: repeated exposure to linear gadolinium-based contrast material is associated with increased signal intensity at unenhanced T1-weighted MR imaging. Radiology 282:222–228CrossRefPubMed Flood TF, Stence NV, Maloney JA et al (2017) Pediatric brain: repeated exposure to linear gadolinium-based contrast material is associated with increased signal intensity at unenhanced T1-weighted MR imaging. Radiology 282:222–228CrossRefPubMed
Metadata
Title
Lack of evidence of a relationship between magnetic resonance signal intensity changes in the globus pallidus and dentate nucleus, and repeated administrations of gadoterate meglumine in children
Authors
Eric Lancelot
Jean-Sébastien Raynaud
Pierre Desché
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 12/2017
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-017-3947-1

Other articles of this Issue 12/2017

Pediatric Radiology 12/2017 Go to the issue