Skip to main content
Top
Published in: Pediatric Radiology 11/2016

01-10-2016 | Original Article

Variables decreasing tip movement of peripherally inserted central catheters in pediatric patients

Authors: Ralph Gnannt, Bairbre L. Connolly, Dimitri A. Parra, Joao Amaral, Rahim Moineddin, Avnesh S. Thakor

Published in: Pediatric Radiology | Issue 11/2016

Login to get access

Abstract

Background

The position of the tip of a peripherally inserted central catheter (PICC) is crucial; malposition can lead to malfunction of the line or life-threatening events (e.g., arrhythmias, perforation).

Objective

To determine what factors other than arm position and accessed vein might influence the tip position of a PICC.

Materials and methods

Inclusion criteria were upper limb PICC placement, body weight <20 kg, intraoperative imaging with the arm in 0°, 45° and 90° abduction and an arm view marking the skin entry site relative to the shoulder. Evaluated variables included patient demographics, and PICC and insertion site characteristics. We measured central tip movement in rib units.

Results

We included 112 children who received a PICC (42 girls/70 boys, mean age 31±13 months, mean weight 6.5±4.9 kg). The overall range of central tip movement was -1 to +4 rib units (mean +0.8±0.7 rib units). Silicone PICCs moved significantly less than polyurethane PICCs (P<0.05). PICCs placed in the cephalic vein moved significantly less than those placed in other veins (P<0.05). Patient demographics and PICC characteristics (size, number of lumens, left or right arm accessed, length of the line) did not influence the range of central tip movement of a PICC (P>0.05).

Conclusion

Silicone PICCs and PICCs inserted into the cephalic vein move less than PICCs made of polyurethane and PICCs inserted into the brachial and basilic veins. These findings might assist operators in deciding which PICC to place in children in a given clinical context.
Literature
1.
go back to reference Connolly B, Mawson JB, MacDonald CE et al (2000) Fluoroscopic landmark for SVC-RA junction for central venous catheter placement in children. Pediatr Radiol 30:692–695CrossRefPubMed Connolly B, Mawson JB, MacDonald CE et al (2000) Fluoroscopic landmark for SVC-RA junction for central venous catheter placement in children. Pediatr Radiol 30:692–695CrossRefPubMed
2.
go back to reference NAoVA Networks (1998) NAVAN position statement. J Vasc Access Devices 3:8–10 NAoVA Networks (1998) NAVAN position statement. J Vasc Access Devices 3:8–10
3.
go back to reference Baskin KM, Jimenez RM, Cahill AM et al (2008) Cavoatrial junction and central venous anatomy: implications for central venous access tip position. J Vasc Interv Radiol 19:359–365CrossRefPubMed Baskin KM, Jimenez RM, Cahill AM et al (2008) Cavoatrial junction and central venous anatomy: implications for central venous access tip position. J Vasc Interv Radiol 19:359–365CrossRefPubMed
4.
go back to reference Darling JC, Newell SJ, Mohamdee O et al (2001) Central venous catheter tip in the right atrium: a risk factor for neonatal cardiac tamponade. J Perinatol 21:461–464CrossRefPubMed Darling JC, Newell SJ, Mohamdee O et al (2001) Central venous catheter tip in the right atrium: a risk factor for neonatal cardiac tamponade. J Perinatol 21:461–464CrossRefPubMed
5.
go back to reference Murray BH, Cohle SD, Davison P (1996) Pericardial tamponade and death from Hickman catheter perforation. Am Surg 62:994–997PubMed Murray BH, Cohle SD, Davison P (1996) Pericardial tamponade and death from Hickman catheter perforation. Am Surg 62:994–997PubMed
6.
go back to reference Puel V, Caudry M, Le Métayer P et al (1993) Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through implanted ports. Cancer 72:2248–2252CrossRefPubMed Puel V, Caudry M, Le Métayer P et al (1993) Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through implanted ports. Cancer 72:2248–2252CrossRefPubMed
7.
go back to reference Racadio JM, Doellman DA, Johnson ND et al (2001) Pediatric peripherally inserted central catheters: complication rates related to catheter tip location. Pediatrics 107:E28CrossRefPubMed Racadio JM, Doellman DA, Johnson ND et al (2001) Pediatric peripherally inserted central catheters: complication rates related to catheter tip location. Pediatrics 107:E28CrossRefPubMed
8.
go back to reference Nadroo AM, Glass RB, Lin J et al (2002) Changes in upper extremity position cause migration of peripherally inserted central catheters in neonates. Pediatrics 110:131–136CrossRefPubMed Nadroo AM, Glass RB, Lin J et al (2002) Changes in upper extremity position cause migration of peripherally inserted central catheters in neonates. Pediatrics 110:131–136CrossRefPubMed
9.
go back to reference Connolly B, Amaral J, Walsh S et al (2006) Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs). Pediatr Radiol 36:845–850CrossRefPubMed Connolly B, Amaral J, Walsh S et al (2006) Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs). Pediatr Radiol 36:845–850CrossRefPubMed
10.
go back to reference Crnich CJ, Halfmann JA, Crone WC et al (2005) The effects of prolonged ethanol exposure on the mechanical properties of polyurethane and silicone catheters used for intravascular access. Infect Control Hosp Epidemiol 26:708–714CrossRefPubMed Crnich CJ, Halfmann JA, Crone WC et al (2005) The effects of prolonged ethanol exposure on the mechanical properties of polyurethane and silicone catheters used for intravascular access. Infect Control Hosp Epidemiol 26:708–714CrossRefPubMed
12.
go back to reference Moran BJ, Sutton GL, Karran SJ (1992) Clinical evaluation of percutaneous insertion and long-term usage of a new cuffed polyurethane catheter for central venous access. Ann R Coll Surg Engl 74:426–429PubMedPubMedCentral Moran BJ, Sutton GL, Karran SJ (1992) Clinical evaluation of percutaneous insertion and long-term usage of a new cuffed polyurethane catheter for central venous access. Ann R Coll Surg Engl 74:426–429PubMedPubMedCentral
13.
14.
go back to reference Dubois J, Rypens F, Garel L et al (2007) Incidence of deep vein thrombosis related to peripherally inserted central catheters in children and adolescents. CMAJ 177:1185–1190CrossRefPubMedPubMedCentral Dubois J, Rypens F, Garel L et al (2007) Incidence of deep vein thrombosis related to peripherally inserted central catheters in children and adolescents. CMAJ 177:1185–1190CrossRefPubMedPubMedCentral
15.
go back to reference Collins JL, Lutz RJ (1991) In vitro study of simultaneous infusion of incompatible drugs in multilumen catheters. Heart Lung 20:271–277PubMed Collins JL, Lutz RJ (1991) In vitro study of simultaneous infusion of incompatible drugs in multilumen catheters. Heart Lung 20:271–277PubMed
16.
go back to reference Gravenstein N, Blackshear RH (1991) In vitro evaluation of relative perforating potential of central venous catheters: comparison of materials, selected models, number of lumens, and angles of incidence to simulated membrane. J Clin Monit 7:1–6CrossRefPubMed Gravenstein N, Blackshear RH (1991) In vitro evaluation of relative perforating potential of central venous catheters: comparison of materials, selected models, number of lumens, and angles of incidence to simulated membrane. J Clin Monit 7:1–6CrossRefPubMed
17.
go back to reference Forauer AR, Alonzo M (2000) Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity. J Vasc Interv Radiol 11:1315–1318CrossRefPubMed Forauer AR, Alonzo M (2000) Change in peripherally inserted central catheter tip position with abduction and adduction of the upper extremity. J Vasc Interv Radiol 11:1315–1318CrossRefPubMed
Metadata
Title
Variables decreasing tip movement of peripherally inserted central catheters in pediatric patients
Authors
Ralph Gnannt
Bairbre L. Connolly
Dimitri A. Parra
Joao Amaral
Rahim Moineddin
Avnesh S. Thakor
Publication date
01-10-2016
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 11/2016
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-016-3648-1

Other articles of this Issue 11/2016

Pediatric Radiology 11/2016 Go to the issue

Hermes

Hermes