Skip to main content
Top
Published in: Pediatric Radiology 9/2015

01-08-2015 | Technical Innovation

Comparison of accelerated 3-D spiral chemical shift imaging and single-voxel spectroscopy at 3T in the pediatric age group

Authors: Sandrine Yazbek, Sanjay P. Prabhu, Pauline Connaughton, Patricia E. Grant, Borjan Gagoski

Published in: Pediatric Radiology | Issue 9/2015

Login to get access

Abstract

Single-voxel spectroscopy (SVS) is usually used in the pediatric population when a short acquisition time is crucial. To overcome the long acquisition time of 3-D phase-encoded chemical shift imaging (CSI) and lack of spatial coverage of single-voxel spectroscopy, efficient encoding schemes using spiral k-space trajectories have been successfully deployed, enabling acquisition of volumetric CSI in <5 min. We assessed feasibility of using 3-D spiral CSI sequence routinely in pediatric clinical settings by comparing its reconstructed spectra against SVS spectra. Volumetric spiral CSI obtained spectra from 2-cc isotropic voxels over a 16×16×10-cm region. SVS acquisition encoded a 3.4-cc (1.5-mm) isotropic voxel. Acquisition time was 3 min for every technique. Data were gathered prospectively from 11 random pediatric patients. Spectra from left basal ganglia were obtained using both techniques and were processed with post-processing software. The following metabolite ratios were calculated: N-acetylaspartate/creatine (NAA/Cr), choline/creatine (Cho/Cr), lactate/creatine (Lac/Cr) and N-acetylapartate/choline (NAA/Cho). We collected data on 11 children ages 4 days to 10 years. In 10/11 cases, spectral quality of both methods was acceptable. Considering 10/11 cases, we found a statistically significant difference between SVS and 3-D spiral CSI for all three ratios. However, this difference was fixed and was probably caused by a fixed bias. This means that 3-D spiral CSI can be used instead of SVS by removing the mean difference between the methods for each ratio. Accelerated 3-D CSI is feasible in pediatric patients and can potentially substitute for SVS.
Literature
1.
go back to reference Barkovich AJ, Baranski K, Vigneron D et al (1999) Proton MR spectroscopy for the evaluation of brain injury in asphyxiated, term neonates. AJNR Am J Neuroradiol 20:1399–1405PubMed Barkovich AJ, Baranski K, Vigneron D et al (1999) Proton MR spectroscopy for the evaluation of brain injury in asphyxiated, term neonates. AJNR Am J Neuroradiol 20:1399–1405PubMed
2.
go back to reference Vigneron DB, Barkovitch AJ, Noworolski SM et al (2001) Three-dimensional proton MR spectroscopic imaging of premature and term neonates. AJNR Am J Neuroradiol 22:1424–1433PubMed Vigneron DB, Barkovitch AJ, Noworolski SM et al (2001) Three-dimensional proton MR spectroscopic imaging of premature and term neonates. AJNR Am J Neuroradiol 22:1424–1433PubMed
3.
go back to reference Blüml S, Wisnowski JL, Nelson MD Jr et al (2013) Metabolic maturation of the human brain from birth through adolescence: insights from in vivo magnetic resonance spectroscopy. Cereb Cortex 23:2944–2955PubMedCentralPubMedCrossRef Blüml S, Wisnowski JL, Nelson MD Jr et al (2013) Metabolic maturation of the human brain from birth through adolescence: insights from in vivo magnetic resonance spectroscopy. Cereb Cortex 23:2944–2955PubMedCentralPubMedCrossRef
4.
go back to reference Andronesi OC, Gagoski BA, Sorensen AG (2012) Neurologic 3D MR spectroscopic imaging with low-power adiabatic pulses and fast spiral acquisition. Radiology 262:647–661PubMedCentralPubMedCrossRef Andronesi OC, Gagoski BA, Sorensen AG (2012) Neurologic 3D MR spectroscopic imaging with low-power adiabatic pulses and fast spiral acquisition. Radiology 262:647–661PubMedCentralPubMedCrossRef
5.
go back to reference Adalsteinsson E, Irarrazabal P, Topp S et al (1998) Volumetric spectroscopic imaging with spiral-based k-space trajectories. Magn Reson Med 39:889–898PubMedCrossRef Adalsteinsson E, Irarrazabal P, Topp S et al (1998) Volumetric spectroscopic imaging with spiral-based k-space trajectories. Magn Reson Med 39:889–898PubMedCrossRef
6.
go back to reference Kreis R, Hofmann L, Kuhlmann B et al (2002) Brain metabolite composition during early human brain development as measured by quantitative in vivo 1H magnetic resonance spectroscopy. Magn Reson Med 48:949–958PubMedCrossRef Kreis R, Hofmann L, Kuhlmann B et al (2002) Brain metabolite composition during early human brain development as measured by quantitative in vivo 1H magnetic resonance spectroscopy. Magn Reson Med 48:949–958PubMedCrossRef
7.
go back to reference Huppi PS, Posse S, Lazeyras F et al (1991) Developmental changes in 1H-spectroscopy in human brain. Pediatr Res 30:574–578PubMedCrossRef Huppi PS, Posse S, Lazeyras F et al (1991) Developmental changes in 1H-spectroscopy in human brain. Pediatr Res 30:574–578PubMedCrossRef
8.
go back to reference Bartha AI, Yap KRL, Miller SP et al (2007) The normal neonatal brain: MR imaging, diffusion tensor imaging, and 3D MR spectroscopy in healthy term neonates. AJNR Am J Neuroradiol 28:1015–1021PubMedCrossRef Bartha AI, Yap KRL, Miller SP et al (2007) The normal neonatal brain: MR imaging, diffusion tensor imaging, and 3D MR spectroscopy in healthy term neonates. AJNR Am J Neuroradiol 28:1015–1021PubMedCrossRef
Metadata
Title
Comparison of accelerated 3-D spiral chemical shift imaging and single-voxel spectroscopy at 3T in the pediatric age group
Authors
Sandrine Yazbek
Sanjay P. Prabhu
Pauline Connaughton
Patricia E. Grant
Borjan Gagoski
Publication date
01-08-2015
Publisher
Springer Berlin Heidelberg
Published in
Pediatric Radiology / Issue 9/2015
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-015-3311-2

Other articles of this Issue 9/2015

Pediatric Radiology 9/2015 Go to the issue