MR evaluation of fetal demise

Authors: Teresa Victoria, Elena Capilla, Nancy Anne Chauvin, Ann M. Johnson, Sandra Sue Kramer, Monica Epelman

Published in: Pediatric Radiology | Issue 7/2011

Login to get access

Abstract

Background

Fetal demise is an uncommon event encountered at MR imaging. When it occurs, recognition by the interpreting radiologist is important to initiate appropriate patient management.

Objective

To identify MR findings of fetal demise.

Materials and methods

Following IRB approval, a retrospective search of the radiology fetal MR database was conducted searching the words “fetal demise” and “fetal death.” Fetuses with obvious maceration or no sonographic confirmation of death were excluded. Eleven cases formed the study group. These were matched randomly to live fetuses of similar gestational age. Images were reviewed independently by three pediatric radiologists.

Results

The deceased fetus demonstrates decreased MR soft-tissue contrast and definition of tissue planes, including loss of gray-white matter differentiation in the brain. The signal within the cardiac chambers, when visible, is bright on HASTE sequences from the stagnant blood; the heart is small. Pleural effusions and decreased lung volumes may be seen. Interestingly, the fetal orbits lose their anatomical round shape and become smaller and more elliptical; a dark, irregular rim resembling a mask may be seen.

Conclusion

Although fetal demise is uncommonly encountered at MR imaging, radiologists should be aware of such imaging findings so prompt management can be instituted.
Literature
1.
go back to reference Kubik-Huch RA, Huisman TA, Wisser J et al (2000) Ultrafast MR imaging of the fetus. AJR 174:1599–1606PubMed Kubik-Huch RA, Huisman TA, Wisser J et al (2000) Ultrafast MR imaging of the fetus. AJR 174:1599–1606PubMed
2.
go back to reference Kern MJ (1976) The use of ultrasound in the assessment of intrauterine fetal death: a review. Mt Sinai J Med 43:281–290PubMed Kern MJ (1976) The use of ultrasound in the assessment of intrauterine fetal death: a review. Mt Sinai J Med 43:281–290PubMed
3.
go back to reference McLeary RD (1982) An early sign of fetal demise. Ultrasonic demonstration of clotted blood within the fetal heart. Radiology 142:712PubMed McLeary RD (1982) An early sign of fetal demise. Ultrasonic demonstration of clotted blood within the fetal heart. Radiology 142:712PubMed
4.
go back to reference Platt LD, Manning FA, Murata Y et al (1980) Diagnosis of fetal death in utero by real-time ultrasound. Obstet Gynecol 55:191–193PubMed Platt LD, Manning FA, Murata Y et al (1980) Diagnosis of fetal death in utero by real-time ultrasound. Obstet Gynecol 55:191–193PubMed
5.
go back to reference Ferris FD, von Gunten CF, Emanuel LL (2003) Competency in end-of-life care: last hours of life. J Palliat Med 6:605–613PubMedCrossRef Ferris FD, von Gunten CF, Emanuel LL (2003) Competency in end-of-life care: last hours of life. J Palliat Med 6:605–613PubMedCrossRef
6.
go back to reference von Gunten CF, Ferris FD, Emanuel LL (2000) The patient-physician relationship. Ensuring competency in end-of-life care: communication and relational skills. JAMA 284:3051–3057CrossRef von Gunten CF, Ferris FD, Emanuel LL (2000) The patient-physician relationship. Ensuring competency in end-of-life care: communication and relational skills. JAMA 284:3051–3057CrossRef
Metadata
Title
MR evaluation of fetal demise
Authors
Teresa Victoria
Elena Capilla
Nancy Anne Chauvin
Ann M. Johnson
Sandra Sue Kramer
Monica Epelman
Publication date
01-07-2011
Publisher
Springer-Verlag
Published in
Pediatric Radiology / Issue 7/2011
Print ISSN: 0301-0449
Electronic ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-011-1995-5

Other articles of this Issue 7/2011

Pediatric Radiology 7/2011 Go to the issue

Hermes

Hermes