Abstract

The Hydro Jet is a new surgical dissection instrument. Applying water to tissues under variable pressure makes selective tissue dissection possible. Larger vessels are less sensitive to water pressure and can be easily coagulated to minimize blood loss. However, the impact of the water pressure on the small blood vessels/microvasculature is not well known. These microvascular changes may be important in the future when using the Hydro Jet as a surgical tool in perforator flap surgery. The abdominal perforator arteries near the umbilicus were dissected with the Hydro Jet in five women who underwent an abdominoplasty for skin/fat excess. The inferior epigastric artery was dissected in one patient who underwent a transverse rectus abdominal musculocutaneous flap procedure for breast reconstruction. Pressure of dissection varied between 30 and 60 bar. Blood vessel specimens were taken and examined using light and electron microscopy. Eighteen samples were taken from six patients. Thirteen samples were dissected with the Hydro Jet; five samples served as controls. No vascular damage was observed microscopically from 30 to 40 bar. Clear signs of vascular damage were observed after dissection with 45 bar with swelling of the (sub)endothelium. At 50 bar dissections the edema of the surrounding stroma increased with loosening of the endothelium. At 60 bar dissections there was obvious damage to all vessel layers. Control samples showed no damage. Dissection of small vessels with the Hydro Jet up to 40 bar does not damage the structural layers histologically. Above this pressure serious damage occurs.
Literature
1.
go back to reference Baer HU, Stain SC, Gaustella T, Maddern GJ, Blumgart LH (1993) Hepatic resection using a water jet dissector. HPB Surgery 6:189–198PubMed Baer HU, Stain SC, Gaustella T, Maddern GJ, Blumgart LH (1993) Hepatic resection using a water jet dissector. HPB Surgery 6:189–198PubMed
2.
go back to reference Bashkar SN, Cutright DE, Frisch J (1969) Effect of high pressure water jet on oral mucosa of varied density. J Peridontol 40:35–40 Bashkar SN, Cutright DE, Frisch J (1969) Effect of high pressure water jet on oral mucosa of varied density. J Peridontol 40:35–40
3.
go back to reference Basting RF, Djakovic N, Widmann P (2000) Use of water jet resection in organ-sparing kidney surgery. J Endourol 14:501–505PubMed Basting RF, Djakovic N, Widmann P (2000) Use of water jet resection in organ-sparing kidney surgery. J Endourol 14:501–505PubMed
4.
go back to reference Hata Y, Sasaki F, Takahashi H, et al (1994) Liver resection in children, using a water-jet. J Pediatr Surg 29:648–650CrossRefPubMed Hata Y, Sasaki F, Takahashi H, et al (1994) Liver resection in children, using a water-jet. J Pediatr Surg 29:648–650CrossRefPubMed
5.
go back to reference Honl M, Dierk O, Kuster JR, et al (2001) Water jet discotomy with microinvasive approach—in vitro testing and initial clinical aspects of a new procedure. Z Orthop Ihre Grenzgeb 139:45–51CrossRefPubMed Honl M, Dierk O, Kuster JR, et al (2001) Water jet discotomy with microinvasive approach—in vitro testing and initial clinical aspects of a new procedure. Z Orthop Ihre Grenzgeb 139:45–51CrossRefPubMed
6.
go back to reference Jurk V, Magritz R, Koch DA, Reusche E, Siegert R (1999) Wasserstrahldissektion in der Zungenchirurgie: eine tierexperimentelle Untersuchung. In: Siegert R et al (eds) Wasserstrahldissektion in der Medizin. Books on Demand, Norderstedt, pp 151–165 Jurk V, Magritz R, Koch DA, Reusche E, Siegert R (1999) Wasserstrahldissektion in der Zungenchirurgie: eine tierexperimentelle Untersuchung. In: Siegert R et al (eds) Wasserstrahldissektion in der Medizin. Books on Demand, Norderstedt, pp 151–165
7.
go back to reference Metelmann HR (1999) Hydrojet-assistierte ästhetische Oberlidplastik—klinische Erfahrungen. In: Siegert R et al (eds) Wasserstrahldissektion in der Medizin. Books on Demand, Norderstedt, pp 113–117 Metelmann HR (1999) Hydrojet-assistierte ästhetische Oberlidplastik—klinische Erfahrungen. In: Siegert R et al (eds) Wasserstrahldissektion in der Medizin. Books on Demand, Norderstedt, pp 113–117
8.
go back to reference Oertel J, Gaab MR, Knapp A, et al (2003) Water jet dissection in neurosurgery: experimental results in the porcine cadaveric brain. Neurosurgery 52:153–159PubMed Oertel J, Gaab MR, Knapp A, et al (2003) Water jet dissection in neurosurgery: experimental results in the porcine cadaveric brain. Neurosurgery 52:153–159PubMed
9.
go back to reference Papachristou DN, Barters R (1982) Resection of the liver with a water jet. Br J Surg 69:93–94PubMed Papachristou DN, Barters R (1982) Resection of the liver with a water jet. Br J Surg 69:93–94PubMed
10.
go back to reference Penchev RD, Kjossev KT, Losanoff JE (1997) Application of a new water jet apparatus in open hepatobiliary surgery: hepatic resection, cholecystectomy, common bile duct lavage. Int Surg 82:182–186PubMed Penchev RD, Kjossev KT, Losanoff JE (1997) Application of a new water jet apparatus in open hepatobiliary surgery: hepatic resection, cholecystectomy, common bile duct lavage. Int Surg 82:182–186PubMed
11.
go back to reference Piek J, Wille C, Warzok R, Gaab MR (1998) Waterjet dissection of the brain: experimental and first clinical results. J Neurosurg 89:861–864PubMed Piek J, Wille C, Warzok R, Gaab MR (1998) Waterjet dissection of the brain: experimental and first clinical results. J Neurosurg 89:861–864PubMed
12.
go back to reference Rau HG, Wichmann MW, Schinkel S, et al (2001) Wasserstrahldissektion bei Leberresektion; Ultraschallaspirator versus Jet-cutter. Zentralbl Chir 126:586–590CrossRefPubMed Rau HG, Wichmann MW, Schinkel S, et al (2001) Wasserstrahldissektion bei Leberresektion; Ultraschallaspirator versus Jet-cutter. Zentralbl Chir 126:586–590CrossRefPubMed
13.
go back to reference Sagar PM, Meaghar A, Sobczak S, Wolff BG (1996) Chemical composition and potential hazards of electrocautery smoke. Br J Surg 83:1792PubMed Sagar PM, Meaghar A, Sobczak S, Wolff BG (1996) Chemical composition and potential hazards of electrocautery smoke. Br J Surg 83:1792PubMed
14.
go back to reference Schrögendorfer KF, Rab M, Kamolz LP, Gruber H, Frey M (1999) Hebung von Perforatorlappen mit dem Hydro-jet Dissektor. In: Siegert R et al (eds) Wasserstrahldissektion in der Medizin. Books on Demand, Norderstedt, pp107–112 Schrögendorfer KF, Rab M, Kamolz LP, Gruber H, Frey M (1999) Hebung von Perforatorlappen mit dem Hydro-jet Dissektor. In: Siegert R et al (eds) Wasserstrahldissektion in der Medizin. Books on Demand, Norderstedt, pp107–112
15.
go back to reference Schurr MO, Wehrmann M, Kunert W, et al (1994) Histologic effects of different technologies for dissection in endoscopic surgery: Nd:Yag laser, high frequency and water-jet. Endosc Surg 2:195–201 Schurr MO, Wehrmann M, Kunert W, et al (1994) Histologic effects of different technologies for dissection in endoscopic surgery: Nd:Yag laser, high frequency and water-jet. Endosc Surg 2:195–201
16.
go back to reference Shekarriz H, Shekarriz B, Kujath P, et al (2003) Hydro Jet assisted laparoscopic cholecystectomy: a prospective randomized clinical study. Surgery 133:635–640CrossRefPubMed Shekarriz H, Shekarriz B, Kujath P, et al (2003) Hydro Jet assisted laparoscopic cholecystectomy: a prospective randomized clinical study. Surgery 133:635–640CrossRefPubMed
17.
go back to reference Siegert R, Danter J, Jurk V, Eggers R, Krüger S (1998) Dermal microvasculature and tissue selective thinning techniques (ultrasound and water-jet) of short-time expanded skin in dogs. Eur Arch Otorhinolaryngol 255:325–330CrossRefPubMed Siegert R, Danter J, Jurk V, Eggers R, Krüger S (1998) Dermal microvasculature and tissue selective thinning techniques (ultrasound and water-jet) of short-time expanded skin in dogs. Eur Arch Otorhinolaryngol 255:325–330CrossRefPubMed
18.
go back to reference Siegert R, Magritz R, Jurk V (2000) Wasserstrahl-dissektion in der Parotischirurgie—erste klinische Resultate. Laryngorhinootologie 79:780–784CrossRefPubMed Siegert R, Magritz R, Jurk V (2000) Wasserstrahl-dissektion in der Parotischirurgie—erste klinische Resultate. Laryngorhinootologie 79:780–784CrossRefPubMed
19.
go back to reference Wilhelm F, Holtkamp A, Duncker GI, Darman J Jr, Knorrn M (2002) Phacoemulsification of human lens nucleus with a water jet. Ophthalmologe 99:286–288CrossRefPubMed Wilhelm F, Holtkamp A, Duncker GI, Darman J Jr, Knorrn M (2002) Phacoemulsification of human lens nucleus with a water jet. Ophthalmologe 99:286–288CrossRefPubMed
Metadata
Title
Hydro Jet dissection of abdominal wall perforator arteries: a pilot study
Authors
X. R. Bakker
P. Nooijen
M. R. Fechner
P. H. M. Spauwen
Publication date
01-10-2004
Publisher
Springer-Verlag
Published in
European Journal of Plastic Surgery / Issue 5/2004
Print ISSN: 0930-343X
Electronic ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-004-0648-4

Other articles of this Issue 5/2004

European Journal of Plastic Surgery 5/2004 Go to the issue