Skip to main content
Top
Published in: Neuroradiology 1/2021

01-01-2021 | Intracranial Aneurysm | Interventional Neuroradiology

Visualization of flow diverter stent wall apposition during intracranial aneurysm treatment using a virtually diluted cone beam CT technique (Vessel ASSIST)

Authors: Ameer E. Hassan, Jim Wise, Elizabeth M. Burke, Wondwossen G. Tekle

Published in: Neuroradiology | Issue 1/2021

Login to get access

Abstract

Purpose

Flow diverters (FD) have poor radiopacity, challenging visualization of deployment and vessel wall apposition with conventional neuroimaging modalities. We evaluated a novel cone beam computed tomography (CT) imaging technique that allows virtual dilution (VD) of contrast media to facilitate workflow and ensure accurate assessment of FD wall apposition.

Methods

We retrospectively evaluated all patients treated for intracranial aneurysms with FD at our institution between November 2018 and November 2019. Undiluted injected dual cone beam CT acquisitions performed post-stenting were displayed with VD software (GE Healthcare). The resulting images were compared with conventional two-dimensional (2D) digital subtraction angiography (DSA) images. Two neurointerventionalists (Reader 1 and Reader 2, (R1, R2)) independently assessed FD deployment and wall apposition. Confidence in the diagnosis, inter-reader agreement, and X-ray exposure were assessed.

Results

A total of 27 cases were reviewed. FD deployment and wall apposition scores were 4.2 ± 1.0 (R1) and 4.0 ± 1.1 (R2) for DSA and 3.7 ± 1.2 (R1) and 4.1 ± 1.0 (R2) for VD. Confidence in the diagnosis was improved with VD, with scores of 3.7 ± 0.7 (R1) and 4.0 ± 0.7 (R2) using DSA and 4.9 ± 0.2 (R1) and 4.9 ± 0.2 (R2) using VD (P < 0.001). Inter-reader agreement using 2D DSA was improved from moderate (0.49324) to good (0.7272) (P < 0.0001). There were no significant differences in inter-reader agreement in the deployment assessment (P = 0.68) or dose-area product (P = 0.54) between techniques.

Conclusion

VD imaging with dual cone beam CT enables accurate assessment of FD wall apposition after deployment with greater confidence and improved inter-reader agreement versus conventional 2D DSA alone, with comparable X-ray exposure.
Literature
1.
go back to reference Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Turner R, Woodward BK, Brinjikji W, Lanzino G, Lylyk P (2015) International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. AJNR Am J Neuroradiol 36(1):108–115. https://doi.org/10.3174/ajnr.A4111CrossRefPubMed Kallmes DF, Hanel R, Lopes D, Boccardi E, Bonafe A, Cekirge S, Fiorella D, Jabbour P, Levy E, McDougall C, Siddiqui A, Szikora I, Woo H, Albuquerque F, Bozorgchami H, Dashti SR, Delgado Almandoz JE, Kelly ME, Turner R, Woodward BK, Brinjikji W, Lanzino G, Lylyk P (2015) International retrospective study of the pipeline embolization device: a multicenter aneurysm treatment study. AJNR Am J Neuroradiol 36(1):108–115. https://​doi.​org/​10.​3174/​ajnr.​A4111CrossRefPubMed
8.
go back to reference Yuki I, Kambayashi Y, Ikemura A, Abe Y, Kan I, Mohamed A, Dahmani C, Suzuki T, Ishibashi T, Takao H, Urashima M, Murayama Y (2016) High-resolution C-arm CT and metal artifact reduction software: a novel imaging modality for analyzing aneurysms treated with stent-assisted coil embolization. AJNR Am J Neuroradiol 37(2):317–323. https://doi.org/10.3174/ajnr.A4509CrossRefPubMed Yuki I, Kambayashi Y, Ikemura A, Abe Y, Kan I, Mohamed A, Dahmani C, Suzuki T, Ishibashi T, Takao H, Urashima M, Murayama Y (2016) High-resolution C-arm CT and metal artifact reduction software: a novel imaging modality for analyzing aneurysms treated with stent-assisted coil embolization. AJNR Am J Neuroradiol 37(2):317–323. https://​doi.​org/​10.​3174/​ajnr.​A4509CrossRefPubMed
11.
Metadata
Title
Visualization of flow diverter stent wall apposition during intracranial aneurysm treatment using a virtually diluted cone beam CT technique (Vessel ASSIST)
Authors
Ameer E. Hassan
Jim Wise
Elizabeth M. Burke
Wondwossen G. Tekle
Publication date
01-01-2021
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 1/2021
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-020-02507-8

Other articles of this Issue 1/2021

Neuroradiology 1/2021 Go to the issue