Skip to main content
Top
Published in: Neuroradiology 1/2018

01-01-2018 | Spinal Neuroradiology

Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study

Authors: Kunihiro Yoshioka, Ryoichi Tanaka, Hidenobu Takagi, Yuta Ueyama, Kei Kikuchi, Takuya Chiba, Kazumasa Arakita, Joanne D. Schuijf, Yasuo Saito

Published in: Neuroradiology | Issue 1/2018

Login to get access

Abstract

Purpose

Preoperative identification of the artery of Adamkiewicz can help prevent postoperative spinal cord injury following thoracic and thoracoabdominal aortic repair. Several studies have demonstrated the feasibility of evaluating the artery of Adamkiewicz using multi-detector row computed tomography (CT), but precise visualization remains a challenge. The present study was conducted to evaluate the usefulness of ultra-high-resolution CT for visualizing the artery of Adamkiewicz with a slice thickness of 0.25 versus 0.5 mm in patients with aortic aneurysms.

Methods

Our institutional review board approved this study. Twenty-four patients with thoracic and thoracoabdominal aneurysms were scanned with beam collimation of 0.25 mm × 128. Images were reconstructed with slice thicknesses of 0.25 and 0.5 mm. The signal-to-noise ratio (SNR) of the aorta and contrast-to-noise ratio (CNR) between the anterior spinal artery and spinal cord were measured. Two independent observers evaluated visualization of the artery of Adamkiewicz and its continuity between the anterior spinal artery and the aorta using a four-point scale.

Results

No significant differences in the SNR of the aorta or CNR of the anterior spinal artery were observed between 0.25- and 0.5-mm slices. The average visualization score was significantly higher for 0.25-mm slices (3.58 ± 0.78) than for 0.5-mm slices (3.13 ± 0.99) (p = 0.01). The percentage of patients with nondiagnostic image quality was significantly lower for 0.25-mm slices (8.3%) than for 0.5-mm slices (33.3%) (p = 0.03).

Conclusion

In patients with aortic aneurysms, ultra-high-resolution CT with 0.25-mm slices significantly improves visualization of the artery of Adamkiewicz compared to 0.5-mm slices.
Literature
1.
go back to reference Coselli JS, Bozinovski J, LeMaire SA (2007) Open surgical repair of 2286 thoracoabdominal aortic aneurysms. Ann Thorac Surg 83:S862–S864CrossRefPubMed Coselli JS, Bozinovski J, LeMaire SA (2007) Open surgical repair of 2286 thoracoabdominal aortic aneurysms. Ann Thorac Surg 83:S862–S864CrossRefPubMed
2.
go back to reference Schepens MA, Heijmen RH, Ranschaert W, Sonker U, Morshuis WJ (2009) Thoracoabdominal aortic aneurysm repair: results of conventional open surgery. Eur J Vasc Endovasc Surg 37:640–645CrossRefPubMed Schepens MA, Heijmen RH, Ranschaert W, Sonker U, Morshuis WJ (2009) Thoracoabdominal aortic aneurysm repair: results of conventional open surgery. Eur J Vasc Endovasc Surg 37:640–645CrossRefPubMed
3.
go back to reference Gialdini G, Parikh NS, Chatterjee A et al (2017) Rates of spinal cord infarction after repair of aortic aneurysm or dissection. Stroke 48:2073–2077CrossRefPubMed Gialdini G, Parikh NS, Chatterjee A et al (2017) Rates of spinal cord infarction after repair of aortic aneurysm or dissection. Stroke 48:2073–2077CrossRefPubMed
4.
go back to reference Kawaharada N, Morishita K, Fukada J et al (2002) Thoracoabdominal or descending aortic aneurysm repair after demonstration of the Adamkiewicz artery by magnetic resonance angiography. Eur J Cardiothorac Surg 21:970–974CrossRefPubMed Kawaharada N, Morishita K, Fukada J et al (2002) Thoracoabdominal or descending aortic aneurysm repair after demonstration of the Adamkiewicz artery by magnetic resonance angiography. Eur J Cardiothorac Surg 21:970–974CrossRefPubMed
5.
go back to reference Ogino H, Sasaki H, Minatoya K, Matsuda H, Yamada N, Kitamura S (2006) Combined use of Adamkiewicz artery demonstration and motor-evoked potentials in descending and thoracoabdominal repair. Ann Thorac Surg 82:592–596CrossRefPubMed Ogino H, Sasaki H, Minatoya K, Matsuda H, Yamada N, Kitamura S (2006) Combined use of Adamkiewicz artery demonstration and motor-evoked potentials in descending and thoracoabdominal repair. Ann Thorac Surg 82:592–596CrossRefPubMed
6.
go back to reference Tanaka H, Ogino H, Minatoya K et al (2016) The impact of preoperative identification of the Adamkiewicz artery on descending and thoracoabdominal aortic repair. J Thorac Cardiovasc Surg 151:122–128CrossRefPubMed Tanaka H, Ogino H, Minatoya K et al (2016) The impact of preoperative identification of the Adamkiewicz artery on descending and thoracoabdominal aortic repair. J Thorac Cardiovasc Surg 151:122–128CrossRefPubMed
7.
go back to reference Takase K, Sawamura Y, Igarashi K et al (2002) Demonstration of the artery of Adamkiewicz at multi-detector row helical CT. Radiology 223:39–45CrossRefPubMed Takase K, Sawamura Y, Igarashi K et al (2002) Demonstration of the artery of Adamkiewicz at multi-detector row helical CT. Radiology 223:39–45CrossRefPubMed
8.
go back to reference Yoshioka K, Niinuma H, Ohira A et al (2003) MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 23:1215–1225CrossRefPubMed Yoshioka K, Niinuma H, Ohira A et al (2003) MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 23:1215–1225CrossRefPubMed
9.
go back to reference Yoshioka K, Niinuma H, Ehara S, Nakajima T, Nakamura M, Kawazoe K (2006) MR angiography and CT angiography of the artery of Adamkiewicz: state of the art. Radiographics 26(Suppl 1):S63–S73CrossRefPubMed Yoshioka K, Niinuma H, Ehara S, Nakajima T, Nakamura M, Kawazoe K (2006) MR angiography and CT angiography of the artery of Adamkiewicz: state of the art. Radiographics 26(Suppl 1):S63–S73CrossRefPubMed
10.
go back to reference Utsunomiya D, Yamashita Y, Okumura S, Urata J (2008) Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: optimization of contrast medium application for 64-detector-row CT angiography. Eur Radiol 18:2684–2690CrossRefPubMed Utsunomiya D, Yamashita Y, Okumura S, Urata J (2008) Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: optimization of contrast medium application for 64-detector-row CT angiography. Eur Radiol 18:2684–2690CrossRefPubMed
11.
go back to reference Takagi H, Ota H, Natsuaki Y et al (2015) Identifying the Adamkiewicz artery using 3-T time-resolved magnetic resonance angiography: its role in addition to multidetector computed tomography angiography. Jpn J Radiol 33:749–756CrossRefPubMed Takagi H, Ota H, Natsuaki Y et al (2015) Identifying the Adamkiewicz artery using 3-T time-resolved magnetic resonance angiography: its role in addition to multidetector computed tomography angiography. Jpn J Radiol 33:749–756CrossRefPubMed
12.
go back to reference Kakinuma R, Moriyama N, Muramatsu Y et al (2015) Ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner. PLoS One 10:e0137165CrossRefPubMedPubMedCentral Kakinuma R, Moriyama N, Muramatsu Y et al (2015) Ultra-high-resolution computed tomography of the lung: image quality of a prototype scanner. PLoS One 10:e0137165CrossRefPubMedPubMedCentral
13.
go back to reference Nishida J, Kitagawa K, Nagata M, Yamazaki A, Nagasawa N, Sakuma H (2013) Model-based iterative reconstruction for multi-detector row CT assessment of the Adamkiewicz artery. Radiology 270:282–291CrossRefPubMed Nishida J, Kitagawa K, Nagata M, Yamazaki A, Nagasawa N, Sakuma H (2013) Model-based iterative reconstruction for multi-detector row CT assessment of the Adamkiewicz artery. Radiology 270:282–291CrossRefPubMed
14.
go back to reference Bley TA, Duffek CC, Francois CJ et al (2010) Presurgical localization of the artery of Adamkiewicz with time-resolved 3.0-T MR angiography. Radiology 255:873–881CrossRefPubMed Bley TA, Duffek CC, Francois CJ et al (2010) Presurgical localization of the artery of Adamkiewicz with time-resolved 3.0-T MR angiography. Radiology 255:873–881CrossRefPubMed
15.
go back to reference Machida H, Tanaka I, Fukui R et al (2013) Improved delineation of the anterior spinal artery with model-based iterative reconstruction in CT angiography: a clinical pilot study. AJR Am J Roentgenol 200:442–446CrossRefPubMed Machida H, Tanaka I, Fukui R et al (2013) Improved delineation of the anterior spinal artery with model-based iterative reconstruction in CT angiography: a clinical pilot study. AJR Am J Roentgenol 200:442–446CrossRefPubMed
16.
go back to reference Nishii T, Kono AK, Nishio M et al (2015) Bone-subtracted spinal CT angiography using nonrigid registration for better visualization of arterial feeders in spinal arteriovenous fistulas. AJNR Am J Neuroradiol 36:2400–2406CrossRefPubMed Nishii T, Kono AK, Nishio M et al (2015) Bone-subtracted spinal CT angiography using nonrigid registration for better visualization of arterial feeders in spinal arteriovenous fistulas. AJNR Am J Neuroradiol 36:2400–2406CrossRefPubMed
17.
go back to reference Kieffer E, Fukui S, Chiras J, Koskas F, Bahnini A, Cormier E (2002) Spinal cord arteriography: a safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy. J Vasc Surg 35:262–268CrossRefPubMed Kieffer E, Fukui S, Chiras J, Koskas F, Bahnini A, Cormier E (2002) Spinal cord arteriography: a safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy. J Vasc Surg 35:262–268CrossRefPubMed
Metadata
Title
Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study
Authors
Kunihiro Yoshioka
Ryoichi Tanaka
Hidenobu Takagi
Yuta Ueyama
Kei Kikuchi
Takuya Chiba
Kazumasa Arakita
Joanne D. Schuijf
Yasuo Saito
Publication date
01-01-2018
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 1/2018
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-017-1927-7

Other articles of this Issue 1/2018

Neuroradiology 1/2018 Go to the issue

Editorial

2017/2018