Skip to main content
Top
Published in: Neuroradiology 6/2013

01-06-2013 | Interventional Neuroradiology

Flow diverter effect on cerebral aneurysm hemodynamics: an in vitro comparison of telescoping stents and the Pipeline

Authors: Breigh N. Roszelle, L. Fernando Gonzalez, M. Haithem Babiker, Justin Ryan, Felipe C. Albuquerque, David H. Frakes

Published in: Neuroradiology | Issue 6/2013

Login to get access

Abstract

Introduction

Flow diverting devices and stents can be used to treat cerebral aneurysms too difficult to treat with coiling or craniotomy and clipping. However, the hemodynamic effects of these devices have not been studied in depth. The objective of this study was to quantify and understand the fluid dynamic changes that occur within bifurcating aneurysms when treated with different devices and configurations.

Methods

Two physical models of bifurcating cerebral aneurysms were constructed: an idealized model and a patient-specific model. The models were treated with four device configurations: a single low-porosity Pipeline embolization device (PED) and one, two, and three high-porosity Enterprise stents deployed in a telescoping fashion. Particle image velocimetry was used to measure the fluid dynamics within the aneurysms; pressure was measured within the patient-specific model.

Results

The PED resulted in the greatest reductions in fluid dynamic activity within the aneurysm for both models. However, a configuration of three telescoping stents reduced the fluid dynamic activity within the aneurysm similarly to the PED treatment. Pressure within the patient-specific aneurysm did not show significant changes among the treatment configurations; however, the pressure difference across the untreated vessel side of the model was greatest with the PED.

Conclusion

Treatment with stents and a flow diverter led to reductions in aneurysmal fluid dynamic activity for both idealized and patient-specific models. While the PED resulted in the greatest flow reductions, telescoping high-porosity stents performed similarly and may represent a viable treatment alternative in situations where the use of a PED is not an option.
Literature
1.
go back to reference Higashida RT, Lahue BJ, Torbey MT, Hopkins LN, Leip E, Hanley DF (2007) Treatment of unruptured intracranial aneurysms: a nationwide assessment of effectiveness. Am J Neuroradiol 28:146–151PubMed Higashida RT, Lahue BJ, Torbey MT, Hopkins LN, Leip E, Hanley DF (2007) Treatment of unruptured intracranial aneurysms: a nationwide assessment of effectiveness. Am J Neuroradiol 28:146–151PubMed
2.
go back to reference International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 360:1267–1274CrossRef International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized trial. Lancet 360:1267–1274CrossRef
3.
go back to reference Molyneux AJ, Kerr RSC, Birks J, Ramzi N, Yarnold J, Sneade M, Rischmiller J (2005) International Subarachnoid Aneurysm Trial (ISAT) of neurological clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysms occlusion. Lancet 366:809–817CrossRefPubMed Molyneux AJ, Kerr RSC, Birks J, Ramzi N, Yarnold J, Sneade M, Rischmiller J (2005) International Subarachnoid Aneurysm Trial (ISAT) of neurological clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomized comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysms occlusion. Lancet 366:809–817CrossRefPubMed
4.
go back to reference Murayama Y, Nien Y, Duckwiler G, Gobin YP, Jahan R, Frazee J, Martin N, Vineula F (2003) Guglielmi detachable coil embolization of cerebral aneurysms: 11 years’ experience. J Neurosurg 98:959–966CrossRefPubMed Murayama Y, Nien Y, Duckwiler G, Gobin YP, Jahan R, Frazee J, Martin N, Vineula F (2003) Guglielmi detachable coil embolization of cerebral aneurysms: 11 years’ experience. J Neurosurg 98:959–966CrossRefPubMed
5.
go back to reference Gaughen JR, Hasan D, Dumont AS, Jensen ME, Mckenzie J, Evans AJ (2010) The efficacy of endovascular stenting in the treatment of supraclinoid internal carotid artery blister aneurysms using a stent-in-stent technique. AJNR 31:1132–1138CrossRefPubMed Gaughen JR, Hasan D, Dumont AS, Jensen ME, Mckenzie J, Evans AJ (2010) The efficacy of endovascular stenting in the treatment of supraclinoid internal carotid artery blister aneurysms using a stent-in-stent technique. AJNR 31:1132–1138CrossRefPubMed
6.
go back to reference Fiorella D, Albuquerque FC, Deshmukh VR, Woo HH, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59(2):291–300CrossRefPubMed Fiorella D, Albuquerque FC, Deshmukh VR, Woo HH, Rasmussen PA, Masaryk TJ, McDougall CG (2006) Endovascular reconstruction with the Neuroform stent as monotherapy for the treatment of uncoilable intradural pseudoaneurysms. Neurosurgery 59(2):291–300CrossRefPubMed
7.
go back to reference Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–17CrossRefPubMed Fiorella D, Albuquerque FC, Han P, McDougall CG (2004) Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms. Neurosurgery 54:6–17CrossRefPubMed
8.
go back to reference Fiorella D, Albuquerque FC, Deshmukh VR, McDougall CG (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1202CrossRefPubMed Fiorella D, Albuquerque FC, Deshmukh VR, McDougall CG (2005) Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3–6-mo) follow-up. Neurosurgery 56:1191–1202CrossRefPubMed
9.
go back to reference Pumar JM, Lete I, Pardo MI, Vazquez-Herrero F, Blanco M (2008) LEO stent monotherapy for the endovascular reconstruction of fusiform aneurysms of the middle cerebral artery. AJNR 29:1775–1776CrossRefPubMed Pumar JM, Lete I, Pardo MI, Vazquez-Herrero F, Blanco M (2008) LEO stent monotherapy for the endovascular reconstruction of fusiform aneurysms of the middle cerebral artery. AJNR 29:1775–1776CrossRefPubMed
10.
go back to reference Levy DI, Ku A (1997) Balloon-assisted coil placement in wide-necked aneurysms: technical note. J Neurosurg 86:724–727CrossRefPubMed Levy DI, Ku A (1997) Balloon-assisted coil placement in wide-necked aneurysms: technical note. J Neurosurg 86:724–727CrossRefPubMed
11.
go back to reference Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR, Berez AL, Tran Q, Nelson PK, Fiorella D (2009) Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 64:632–642CrossRefPubMed Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR, Berez AL, Tran Q, Nelson PK, Fiorella D (2009) Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience. Neurosurgery 64:632–642CrossRefPubMed
12.
go back to reference Wong G, Kwan M, Ng R, Yu S, Poon W (2011) Flow diverters for treatment of intracranial aneurysms: current status and ongoing clinical trials. J Clin Neurosci 18:737–740CrossRefPubMed Wong G, Kwan M, Ng R, Yu S, Poon W (2011) Flow diverters for treatment of intracranial aneurysms: current status and ongoing clinical trials. J Clin Neurosci 18:737–740CrossRefPubMed
13.
go back to reference Canton G, Levy DI, Lasheras JC, Nelson PK (2005) Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms. J Neurosurg 103:891–902CrossRefPubMed Canton G, Levy DI, Lasheras JC, Nelson PK (2005) Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms. J Neurosurg 103:891–902CrossRefPubMed
14.
go back to reference Roszelle BN, Babiker MH, Hafner W, Gonzalez F, Albuquerque F, Frakes DH (2012) In vitro and in silico study of intracranial stent treatments for cerebral aneurysms: effects of perforating vessel flows. J NeuroIntervent Surg. doi:10.1136/neurintsurg-2012-010322 Roszelle BN, Babiker MH, Hafner W, Gonzalez F, Albuquerque F, Frakes DH (2012) In vitro and in silico study of intracranial stent treatments for cerebral aneurysms: effects of perforating vessel flows. J NeuroIntervent Surg. doi:10.​1136/​neurintsurg-2012-010322
15.
go back to reference Tremmel M, Xiang J, Natarajan SK, Hopkins LN, Siddiqui AH, Levy EI, Meng H (2010) Alteration of intraaneurysmal hemodynamics for flow diversion using enterprise and vision stents. World Neurosurg 74(2/3):306–315CrossRefPubMed Tremmel M, Xiang J, Natarajan SK, Hopkins LN, Siddiqui AH, Levy EI, Meng H (2010) Alteration of intraaneurysmal hemodynamics for flow diversion using enterprise and vision stents. World Neurosurg 74(2/3):306–315CrossRefPubMed
16.
go back to reference Frakes D, Pekkan K, Dasi L, Kitajima H, Zelicourt D, Leo HL, Carberry J, Sundereswaran K, Simon H, Yoganathan A (2008) Modified control grid interpolation for the volumetric reconstruction of fluid flows. Exp Fluids 45:987–997CrossRefPubMed Frakes D, Pekkan K, Dasi L, Kitajima H, Zelicourt D, Leo HL, Carberry J, Sundereswaran K, Simon H, Yoganathan A (2008) Modified control grid interpolation for the volumetric reconstruction of fluid flows. Exp Fluids 45:987–997CrossRefPubMed
17.
go back to reference Frakes DH, Conrad CP, Healy TM, Monaco JW, Fogel M, Sharma S, Smith MJT, Yoganathan AP (2003) Application of an adaptive control grid interpolation technique to morphological vascular reconstruction. IEEE Trans Biomed Eng 50(2):197–206CrossRefPubMed Frakes DH, Conrad CP, Healy TM, Monaco JW, Fogel M, Sharma S, Smith MJT, Yoganathan AP (2003) Application of an adaptive control grid interpolation technique to morphological vascular reconstruction. IEEE Trans Biomed Eng 50(2):197–206CrossRefPubMed
18.
go back to reference Ford MD, Alperin N, Lee SH, Holdsworth DW, Steinman DA (2005) Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas 26:477–488CrossRefPubMed Ford MD, Alperin N, Lee SH, Holdsworth DW, Steinman DA (2005) Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas 26:477–488CrossRefPubMed
19.
go back to reference Babiker H, Gonzalez LF, Albuquerque F, Collins D, Elvikis A, Frakes D (2010) Quantitative effects of coil packing density on cerebral aneurysm fluid dynamics: an in vitro steady flow study. Ann Biomed Eng 38(7):2293–2301CrossRefPubMed Babiker H, Gonzalez LF, Albuquerque F, Collins D, Elvikis A, Frakes D (2010) Quantitative effects of coil packing density on cerebral aneurysm fluid dynamics: an in vitro steady flow study. Ann Biomed Eng 38(7):2293–2301CrossRefPubMed
20.
go back to reference Darsaut TE, Bing F, Salazkin I, Gevry G, Raymond J (2012) Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: an in vivo study in canines. J Neurosurg 117:37–44CrossRefPubMed Darsaut TE, Bing F, Salazkin I, Gevry G, Raymond J (2012) Flow diverters failing to occlude experimental bifurcation or curved sidewall aneurysms: an in vivo study in canines. J Neurosurg 117:37–44CrossRefPubMed
21.
go back to reference Shobayashi Y, Tanoue T, Tateshima S, Tanishita K (2010) Mechanical design of an intracranial stent for treating cerebral aneurysms. Med Eng Phys 32:1015–1024CrossRefPubMed Shobayashi Y, Tanoue T, Tateshima S, Tanishita K (2010) Mechanical design of an intracranial stent for treating cerebral aneurysms. Med Eng Phys 32:1015–1024CrossRefPubMed
22.
go back to reference Fiorella D, Lylyk P, Szikora I, Kelly ME, Albuquerque FC, McDougall CG, Nelson PK (2009) Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms. J NeuroInterv Surg 1:56–65CrossRefPubMed Fiorella D, Lylyk P, Szikora I, Kelly ME, Albuquerque FC, McDougall CG, Nelson PK (2009) Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms. J NeuroInterv Surg 1:56–65CrossRefPubMed
23.
go back to reference Lieber B, Gounis M (2002) The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms. Neuro Res 24:33–42CrossRef Lieber B, Gounis M (2002) The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms. Neuro Res 24:33–42CrossRef
24.
go back to reference Conrad W (1969) Pressure flow relationships in collapsible tubes. IEEE Trans Biomed Eng 16:284–295CrossRefPubMed Conrad W (1969) Pressure flow relationships in collapsible tubes. IEEE Trans Biomed Eng 16:284–295CrossRefPubMed
25.
go back to reference Dorn F, Niedermeyer F, Balasso A, Liepsch D, Liebeg T (2011) The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry. Neuroradiology 53:267–272CrossRefPubMed Dorn F, Niedermeyer F, Balasso A, Liepsch D, Liebeg T (2011) The effect of stents on intra-aneurysmal hemodynamics: in vitro evaluation of a pulsatile sidewall aneurysm using laser Doppler anemometry. Neuroradiology 53:267–272CrossRefPubMed
Metadata
Title
Flow diverter effect on cerebral aneurysm hemodynamics: an in vitro comparison of telescoping stents and the Pipeline
Authors
Breigh N. Roszelle
L. Fernando Gonzalez
M. Haithem Babiker
Justin Ryan
Felipe C. Albuquerque
David H. Frakes
Publication date
01-06-2013
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 6/2013
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-013-1169-2

Other articles of this Issue 6/2013