Abstract

One of the feared complications during detachable coil embolization of cerebral aneurysms is herniation of a coil loop into the parent artery. Although coil protrusion of one or two loops into the parent vessel may not cause adverse events and in some instances can be ignored, the authors believe that coil retrieval is indicated if a free end is seen pulsating along the blood flow stream to prevent migration of the entire coil mass. In one patient, a microballoon was inflated across the neck of the aneurysm during retrieval of a herniated coil to prevent further coil herniation from the aneurysm sac. We present two cases in which prolapsed coils were successfully retrieved either using a microsnare and balloon combination or a microsnare alone. This report focuses on the efficacy of the Amplatz microsnare for such retrievals and the circumstances in which a herniated coil needs to be retrieved. We report two cases in which embolization coils partially migrated into the parent artery during endovascular treatment of cerebral aneurysm and were retrieved using the Amplatz Nitinol microsnare.
Literature
1.
go back to reference Phatouros CC, McConachie NS, Jaspan T (1999) Post-procedure migration of Guglielmi detachable coils and mechanical detachable spirals. Neuroradiology 41:324–327CrossRefPubMed Phatouros CC, McConachie NS, Jaspan T (1999) Post-procedure migration of Guglielmi detachable coils and mechanical detachable spirals. Neuroradiology 41:324–327CrossRefPubMed
2.
go back to reference Standard SC, Chavis TD, Wakhloo AK, Ahuja A, Guterman LR, Hopkins LN (1994) Retrieval of a Guglielmi detachable coil after unravelling and fracture: case report and experimental results. Neurosurgery 35:994–999PubMedCrossRef Standard SC, Chavis TD, Wakhloo AK, Ahuja A, Guterman LR, Hopkins LN (1994) Retrieval of a Guglielmi detachable coil after unravelling and fracture: case report and experimental results. Neurosurgery 35:994–999PubMedCrossRef
3.
go back to reference Doerfler A, Wanke I, Egelhof T, et al (2001) Aneurysmal rupture during embolization with Guglielmi detachable coils: cause, management, and outcome. AJNR Am J Neuroradiol 22:1825–1832PubMed Doerfler A, Wanke I, Egelhof T, et al (2001) Aneurysmal rupture during embolization with Guglielmi detachable coils: cause, management, and outcome. AJNR Am J Neuroradiol 22:1825–1832PubMed
4.
go back to reference Fressler RD, Ringer AJ, Qureshi AI, Guterman LR, Hopkins LN (2000) Intracranial stent placement to trap an extruded coil during endovascular aneurysm treatment: technical note. Neurosurgery 46:248–253CrossRefPubMed Fressler RD, Ringer AJ, Qureshi AI, Guterman LR, Hopkins LN (2000) Intracranial stent placement to trap an extruded coil during endovascular aneurysm treatment: technical note. Neurosurgery 46:248–253CrossRefPubMed
5.
go back to reference Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms: long-term angiographic and clinical results – apropos of 56 cases. J Neuroradiol 24:30–44PubMed Moret J, Cognard C, Weill A, Castaings L, Rey A (1997) Reconstruction technique in the treatment of wide-neck intracranial aneurysms: long-term angiographic and clinical results – apropos of 56 cases. J Neuroradiol 24:30–44PubMed
6.
go back to reference Malek AM, Higashida RT, Phatouros CC, Dowd CF, Halbach VV (1999) Treatment of an intracranial aneurysm using a new three-dimensional-shape Guglielmi detachable coil: technical case report. Neurosurgery 44:1142–1145CrossRefPubMed Malek AM, Higashida RT, Phatouros CC, Dowd CF, Halbach VV (1999) Treatment of an intracranial aneurysm using a new three-dimensional-shape Guglielmi detachable coil: technical case report. Neurosurgery 44:1142–1145CrossRefPubMed
7.
go back to reference Lavine SD, Larsen DW, Giannotta SL, Teitelbaum GP (2000) Parent vessel Guglielmi detachable coil herniation during wide-necked aneurysm embolization: treatment with intracranial stent placement: two technical case reports. Neurosurgery 46:1013–1017CrossRefPubMed Lavine SD, Larsen DW, Giannotta SL, Teitelbaum GP (2000) Parent vessel Guglielmi detachable coil herniation during wide-necked aneurysm embolization: treatment with intracranial stent placement: two technical case reports. Neurosurgery 46:1013–1017CrossRefPubMed
8.
go back to reference Sugiu K, Martin JB, Jean B, Rüfenacht DA (2002) Rescue balloon procedure for an emergency situation during coil embolization for cerebral aneurysms. J Neurosurg 96:373–376PubMedCrossRef Sugiu K, Martin JB, Jean B, Rüfenacht DA (2002) Rescue balloon procedure for an emergency situation during coil embolization for cerebral aneurysms. J Neurosurg 96:373–376PubMedCrossRef
9.
go back to reference Smith TP, Graves VB, Halbach VV, et al (1993) Microcatheter retrieval device for intravascular foreign body removal. AJNR Am J Neuroradiol 14:809–811PubMed Smith TP, Graves VB, Halbach VV, et al (1993) Microcatheter retrieval device for intravascular foreign body removal. AJNR Am J Neuroradiol 14:809–811PubMed
10.
go back to reference Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN (1998) Stents for intracranial aneurysms: the beginning of a new endovascular era? Neurosurgery 43:377–379CrossRefPubMed Wakhloo AK, Lanzino G, Lieber BB, Hopkins LN (1998) Stents for intracranial aneurysms: the beginning of a new endovascular era? Neurosurgery 43:377–379CrossRefPubMed
11.
go back to reference Cognard C, Weill A, Spelle L, Piotin M, Castaings L, Rey A, Moret J (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212:348–356PubMed Cognard C, Weill A, Spelle L, Piotin M, Castaings L, Rey A, Moret J (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212:348–356PubMed
Metadata
Title
Retrieval of prolapsed coils during endovascular treatment of cerebral aneurysms
Authors
Hasan Dinc
Kayhan Kuzeyli
Polat Kosucu
Ahmet Sari
Saruhan Cekirge
Publication date
01-04-2006
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 4/2006
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-006-0051-x

Other articles of this Issue 4/2006

Neuroradiology 4/2006 Go to the issue