Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 2/2022

01-02-2022 | KNEE

Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial

Authors: Narendra V. Vaidya, Ajinkya N. Deshpande, Taufiq Panjwani, Rakesh Patil, Tanmay Jaysingani, Pratik Patil

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 2/2022

Login to get access

Abstract

Purpose

Correct positioning and alignment of the prosthesis is a very important factor for durability of prosthesis and implant survival which is improved with the use of technology in total knee arthroplasty. However, the long-term functional outcomes and survivorship are unclear. For this study, it was hypothesized that mechanical axis alignment of lower limb, post-operative joint line restoration, femoral and tibial component alignment is more accurate with the new handheld semi-active robotic-assisted TKA.

Method

From April-2019 to March-2020, 60 patients with unilateral knee osteoarthritis who underwent total knee arthroplasties were included in this prospective randomised controlled study. Computer generated randomization was used. Study included 48 female patients and 12 male patients. Pre-operative and post-operative radiographic measurements were done and compared between the two groups.

Results

There was a significant difference between two groups with respect to mechanical axis deviation, joint line deviation and coronal alignment of femoral and tibial prosthesis. Mechanical axis deviation > 3° was seen in eight cases (28.5%) in C-TKA group compared to one case (3.1%) in RA-TKA (p 0.019). Joint line deviation of 3.5 mm was noted in C-TKA group as compared to 0.9 mm in RA-TKA group (p < 0.001) which was statistically significant. However, whether this difference of 2.6 mm of joint line elevation between C-TKA and RA-TKA leads to any difference in clinical outcome in terms of knee kinematics and knee flexion needs to be investigated with further studies. Clinically restoring normal joint line is important for improved knee function after primary TKA. No significant difference was noted in femoral component rotation on post-operative computed tomography (CT) scan.

Conclusion

The novel imageless, handheld semi-autonomous robotic system for TKA is highly accurate with respect to component positioning in coronal plane and mechanical alignment as compared to conventional TKA. Joint line is elevated in conventional TKA but is accurately restored using the robotic-assisted TKA which may lead to better patellofemoral kinematics.

Level of evidence

I.
Literature
1.
go back to reference Antonios JK, Korber S, Sivasundaram L, Mayfield C, Kang HP, Oakes DA et al (2019) Trends in computer navigation and robotic assistance for total knee arthroplasty in the United States: an analysis of patient and hospital factors. Arthroplast Today 5:88–95CrossRef Antonios JK, Korber S, Sivasundaram L, Mayfield C, Kang HP, Oakes DA et al (2019) Trends in computer navigation and robotic assistance for total knee arthroplasty in the United States: an analysis of patient and hospital factors. Arthroplast Today 5:88–95CrossRef
2.
go back to reference Babazadeh S, Dowsey MM, Swan JD, Stoney JD, Choong PF (2011) Joint line position correlates with function after primary total knee replacement: a randomised controlled trial comparing conventional and computer-assisted surgery. J Bone Joint Surg Br 93:1223–1231CrossRef Babazadeh S, Dowsey MM, Swan JD, Stoney JD, Choong PF (2011) Joint line position correlates with function after primary total knee replacement: a randomised controlled trial comparing conventional and computer-assisted surgery. J Bone Joint Surg Br 93:1223–1231CrossRef
3.
go back to reference Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183CrossRef Bargren JH, Blaha JD, Freeman MA (1983) Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. Clin Orthop Relat Res 173:178–183CrossRef
4.
go back to reference Bellemans J, Vandenneucker H, Vanlauwe J (2007) Robot-assisted total knee arthroplasty. Clin Orthop Relat Res 464:111–116CrossRef Bellemans J, Vandenneucker H, Vanlauwe J (2007) Robot-assisted total knee arthroplasty. Clin Orthop Relat Res 464:111–116CrossRef
6.
go back to reference Bonner TJ, Eardley WG, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br 93:1217–1222CrossRef Bonner TJ, Eardley WG, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br 93:1217–1222CrossRef
7.
go back to reference Boylan M, Suchman K, Vigdorchik J, Slover J, Bosco J (2018) Technology-assisted hip and knee arthroplasties: an analysis of utilization trends. J Arthroplasty 33:1019–1023CrossRef Boylan M, Suchman K, Vigdorchik J, Slover J, Bosco J (2018) Technology-assisted hip and knee arthroplasties: an analysis of utilization trends. J Arthroplasty 33:1019–1023CrossRef
8.
go back to reference Casper M, Mitra R, Khare R, Jaramaz B, Hamlin B, McGinley B et al (2018) Accuracy assessment of a novel image-free handheld robot for total knee arthroplasty in a cadaveric study. Comput Assist Surg (Abingdon) 23:14–20CrossRef Casper M, Mitra R, Khare R, Jaramaz B, Hamlin B, McGinley B et al (2018) Accuracy assessment of a novel image-free handheld robot for total knee arthroplasty in a cadaveric study. Comput Assist Surg (Abingdon) 23:14–20CrossRef
9.
go back to reference Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569CrossRef Choong PF, Dowsey MM, Stoney JD (2009) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplasty 24:560–569CrossRef
10.
go back to reference Decking J, Theis C, Achenbach T, Roth E, Nafe B, Eckardt A (2004) Robotic total knee arthroplasty: the accuracy of CT-based component placement. Acta Orthop Scand 75:573–579CrossRef Decking J, Theis C, Achenbach T, Roth E, Nafe B, Eckardt A (2004) Robotic total knee arthroplasty: the accuracy of CT-based component placement. Acta Orthop Scand 75:573–579CrossRef
11.
go back to reference Song EK, Seon JK, Kang KD, Park CH, Yim JH (2012) The effect of joint line elevation on mid-flexion stability in cruciate retaining TKA. Orthopaedic Proc 94:41 Song EK, Seon JK, Kang KD, Park CH, Yim JH (2012) The effect of joint line elevation on mid-flexion stability in cruciate retaining TKA. Orthopaedic Proc 94:41
12.
go back to reference Fornalski S, McGarry MH, Bui CN, Kim WC, Lee TQ (2012) Biomechanical effects of joint line elevation in total knee arthroplasty. Clin Biomech (Bristol, Avon) 27:824–829CrossRef Fornalski S, McGarry MH, Bui CN, Kim WC, Lee TQ (2012) Biomechanical effects of joint line elevation in total knee arthroplasty. Clin Biomech (Bristol, Avon) 27:824–829CrossRef
13.
go back to reference Goodfellow JW, O’Connor J (1986) Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. Clin Orthop Relat Res 205:21–42CrossRef Goodfellow JW, O’Connor J (1986) Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. Clin Orthop Relat Res 205:21–42CrossRef
14.
go back to reference Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22CrossRef Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22CrossRef
15.
go back to reference Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am 58:754–765CrossRef Insall JN, Ranawat CS, Aglietti P, Shine J (1976) A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg Am 58:754–765CrossRef
16.
go back to reference Jawhar A, Shah V, Sohoni S, Scharf HP (2013) Joint line changes after primary total knee arthroplasty: navigated versus non-navigated. Knee Surg Sports Traumatol Arthrosc 21:2355–2362CrossRef Jawhar A, Shah V, Sohoni S, Scharf HP (2013) Joint line changes after primary total knee arthroplasty: navigated versus non-navigated. Knee Surg Sports Traumatol Arthrosc 21:2355–2362CrossRef
17.
go back to reference Kawamura H, Bourne RB (2001) Factors affecting range of flexion after total knee arthroplasty. J Orthop Sci 6:248–252CrossRef Kawamura H, Bourne RB (2001) Factors affecting range of flexion after total knee arthroplasty. J Orthop Sci 6:248–252CrossRef
18.
go back to reference Kayani B, Haddad FS (2019) Robotic total knee arthroplasty. Bone Jt Res 8:438–442CrossRef Kayani B, Haddad FS (2019) Robotic total knee arthroplasty. Bone Jt Res 8:438–442CrossRef
19.
go back to reference Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38:379–385CrossRef Kim YH, Park JW, Kim JS, Park SD (2014) The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop 38:379–385CrossRef
20.
go back to reference Kumar N, Mukhopadhaya J, Yadav C, Anand S, Singh S (2017) Joint line restoration in total knee arthroplasty. J Orthop Allied Sci 5:10–14 Kumar N, Mukhopadhaya J, Yadav C, Anand S, Singh S (2017) Joint line restoration in total knee arthroplasty. J Orthop Allied Sci 5:10–14
21.
go back to reference Li PH, Wong YC, Wai YL (2007) Knee flexion after total knee arthroplasty. J Orthop Surg (Hong Kong) 15:149–153CrossRef Li PH, Wong YC, Wai YL (2007) Knee flexion after total knee arthroplasty. J Orthop Surg (Hong Kong) 15:149–153CrossRef
22.
go back to reference Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29:2373–2377CrossRef Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29:2373–2377CrossRef
23.
go back to reference Liu HX, Shang P, Ying XZ, Zhang Y (2016) Shorter survival rate in varus-aligned knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:2663–2671CrossRef Liu HX, Shang P, Ying XZ, Zhang Y (2016) Shorter survival rate in varus-aligned knees after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:2663–2671CrossRef
24.
go back to reference Mancino F, Cacciola G, Malahias MA, De Filippis R, De Marco D, Di Matteo V et al (2020) What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies. Orthop Rev (Pavia) 12:8657 Mancino F, Cacciola G, Malahias MA, De Filippis R, De Marco D, Di Matteo V et al (2020) What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies. Orthop Rev (Pavia) 12:8657
25.
go back to reference Moon YW, Ha CW, Do KH, Kim CY, Han JH, Na SE et al (2012) Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Comput Aided Surg 17:86–95CrossRef Moon YW, Ha CW, Do KH, Kim CY, Han JH, Na SE et al (2012) Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment. Comput Aided Surg 17:86–95CrossRef
26.
go back to reference Moreland JR (1988) Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 226:49–64CrossRef Moreland JR (1988) Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 226:49–64CrossRef
27.
go back to reference Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426CrossRef Oswald MH, Jakob RP, Schneider E, Hoogewoud HM (1993) Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty 8:419–426CrossRef
28.
go back to reference Ranawat CS, Boachie-Adjei O (1988) Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period. Clin Orthop Relat Res 226:6–13CrossRef Ranawat CS, Boachie-Adjei O (1988) Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period. Clin Orthop Relat Res 226:6–13CrossRef
29.
go back to reference Ren Y, Cao S, Wu J, Weng X, Feng B (2019) Efficacy and reliability of active robotic-assisted total knee arthroplasty compared with conventional total knee arthroplasty: a systematic review and meta-analysis. Postgrad Med J 95:125–133CrossRef Ren Y, Cao S, Wu J, Weng X, Feng B (2019) Efficacy and reliability of active robotic-assisted total knee arthroplasty compared with conventional total knee arthroplasty: a systematic review and meta-analysis. Postgrad Med J 95:125–133CrossRef
30.
go back to reference Song EK, Seon JK, Park SJ, Jung WB, Park HW, Lee GW (2011) Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 19:1069–1076CrossRef Song EK, Seon JK, Park SJ, Jung WB, Park HW, Lee GW (2011) Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 19:1069–1076CrossRef
31.
go back to reference Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL (2013) Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 471:118–126CrossRef Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL (2013) Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 471:118–126CrossRef
32.
go back to reference Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Jt Surg Br 67:551–556CrossRef Tew M, Waugh W (1985) Tibiofemoral alignment and the results of knee replacement. J Bone Jt Surg Br 67:551–556CrossRef
33.
go back to reference van Lieshout WAM, Valkering KP, Koenraadt KLM, van Etten-Jamaludin FS, Kerkhoffs G, van Geenen RCI (2019) The negative effect of joint line elevation after total knee arthroplasty on outcome. Knee Surg Sports Traumatol Arthrosc 27:1477–1486CrossRef van Lieshout WAM, Valkering KP, Koenraadt KLM, van Etten-Jamaludin FS, Kerkhoffs G, van Geenen RCI (2019) The negative effect of joint line elevation after total knee arthroplasty on outcome. Knee Surg Sports Traumatol Arthrosc 27:1477–1486CrossRef
34.
go back to reference Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ (2005) The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 38:349–355CrossRef Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ (2005) The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 38:349–355CrossRef
35.
go back to reference Wyss TF, Schuster AJ, Munger P, Pfluger D, Wehrli U (2006) Does total knee joint replacement with the soft tissue balancing surgical technique maintain the natural joint line? Arch Orthop Trauma Surg 126:480–486CrossRef Wyss TF, Schuster AJ, Munger P, Pfluger D, Wehrli U (2006) Does total knee joint replacement with the soft tissue balancing surgical technique maintain the natural joint line? Arch Orthop Trauma Surg 126:480–486CrossRef
36.
go back to reference Xie K, Han X, Jiang X, Ai S, Dai K, Yu Z et al (2019) The effect of varus knee deformities on the ankle alignment in patients with knee osteoarthritis. J Orthop Surg Res 14:134CrossRef Xie K, Han X, Jiang X, Ai S, Dai K, Yu Z et al (2019) The effect of varus knee deformities on the ankle alignment in patients with knee osteoarthritis. J Orthop Surg Res 14:134CrossRef
Metadata
Title
Robotic-assisted TKA leads to a better prosthesis alignment and a better joint line restoration as compared to conventional TKA: a prospective randomized controlled trial
Authors
Narendra V. Vaidya
Ajinkya N. Deshpande
Taufiq Panjwani
Rakesh Patil
Tanmay Jaysingani
Pratik Patil
Publication date
01-02-2022
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 2/2022
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-020-06353-2

Other articles of this Issue 2/2022

Knee Surgery, Sports Traumatology, Arthroscopy 2/2022 Go to the issue