Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2018

01-06-2018 | Knee

Gait analysis following medial opening-wedge high tibial osteotomy

Authors: Vincent Morin, Régis Pailhé, Brice Rubens Duval, Roch Mader, Jérémy Cognault, René-Christopher Rouchy, Dominique Saragaglia

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 6/2018

Login to get access

Abstract

Purpose

High tibial osteotomy (HTO) is used to treat young and active patients with knee osteoarthritis (OA) and varus deformity. The medial compartment OA alters the patients’ gait.

Methods

A prospective study was carried out in 21 consecutive patients operated for HTO due to knee OA with varus deformity. There were 14 men and 7 women, with a median age of 51.9 years (38–64). Their gait was analyzed preoperatively and at 1 year postoperatively, and compared to a healthy control group. Clinical assessment (KOOS, WOMAC, Lysholm, and SF-36 scores) was also performed preoperatively and postoperatively.

Results

Patients with medial compartment OA had altered gait relative to the control population. Their walking speed was slower, step length was shorter, and single-leg stance time was shorter, while the double-leg stance time was longer (P < 0.001). Step width was not different between the two groups preoperatively (n.s.), but it was wider in the patient group postoperatively (P = 0.003). There were no differences in the patients’ gait parameters before and after the osteotomy (n.s.). However, there was an improved perception of walking so that it is no longer different from controls (n.s.). The KOOS, WOMAC, Lysholm and SF-36 scores improved after HTO. The preoperative median of 7° varus (1–11) was corrected to 3° valgus (0–6).

Conclusion

Medial compartment OA with varus deformity leads to gait modifications. HTO does not alter the time–distance parameters of gait; however, patients have improved perception of their walking ability. HTO leads to excellent results for knee function, and improves quality of life without modifying the gait pattern.

Level of evidence

II.
Literature
1.
go back to reference Aglietti P, Buzzi R, Vena LM, Baldini A, Mondaini A (2003) High tibial valgus osteotomy for medial gonarthrosis: a 10- to 21-year study. J Knee Surg 16:21–26PubMed Aglietti P, Buzzi R, Vena LM, Baldini A, Mondaini A (2003) High tibial valgus osteotomy for medial gonarthrosis: a 10- to 21-year study. J Knee Surg 16:21–26PubMed
2.
go back to reference Agneskirchner JD, Hurschler C, Wrann CD, Lobenhoffer P (2007) The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee: a biomechanical study. Arthroscopy 23:852–861CrossRefPubMed Agneskirchner JD, Hurschler C, Wrann CD, Lobenhoffer P (2007) The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee: a biomechanical study. Arthroscopy 23:852–861CrossRefPubMed
3.
go back to reference Andriacchi TP (1994) Dynamics of knee malalignment. Orthop Clin North Am 25:395–403PubMed Andriacchi TP (1994) Dynamics of knee malalignment. Orthop Clin North Am 25:395–403PubMed
4.
go back to reference Birmingham TB, Giffin JR, Chesworth BM, Bryant DM, Litchfield RB, Willits K, Jenkyn TR, Fowler PJ (2009) Medial opening wedge high tibial osteotomy: a prospective cohort study of gait, radiographic, and patient-reported outcomes. Arthritis Rheum 61:648–657CrossRefPubMed Birmingham TB, Giffin JR, Chesworth BM, Bryant DM, Litchfield RB, Willits K, Jenkyn TR, Fowler PJ (2009) Medial opening wedge high tibial osteotomy: a prospective cohort study of gait, radiographic, and patient-reported outcomes. Arthritis Rheum 61:648–657CrossRefPubMed
5.
go back to reference Birmingham TB, Hunt MA, Jones IC, Jenkyn TR, Giffin JR (2007) Test–retest reliability of the peak knee adduction moment during walking in patients with medial compartment knee osteoarthritis. Arthritis Rheum 57:1012–1017CrossRefPubMed Birmingham TB, Hunt MA, Jones IC, Jenkyn TR, Giffin JR (2007) Test–retest reliability of the peak knee adduction moment during walking in patients with medial compartment knee osteoarthritis. Arthritis Rheum 57:1012–1017CrossRefPubMed
6.
go back to reference Blaha JD (2004) The rationale for a total knee implant that confers anteroposterior stability throughout range of motion. J Arthroplasty 19:22–26CrossRefPubMed Blaha JD (2004) The rationale for a total knee implant that confers anteroposterior stability throughout range of motion. J Arthroplasty 19:22–26CrossRefPubMed
7.
go back to reference Börjesson M, Weidenhielm L, Mattsson E, Olsson E (2005) Gait and clinical measurements in patients with knee osteoarthritis after surgery: a prospective 5-year follow-up study. Knee 12:121–127CrossRefPubMed Börjesson M, Weidenhielm L, Mattsson E, Olsson E (2005) Gait and clinical measurements in patients with knee osteoarthritis after surgery: a prospective 5-year follow-up study. Knee 12:121–127CrossRefPubMed
8.
go back to reference Briem K, Ramsey DK, Newcomb W, Rudolph KS, Snyder-Mackler L (2007) Effects of the amount of valgus correction for medial compartment knee osteoarthritis on clinical outcome, knee kinetics and muscle co-contraction after opening wedge high tibial osteotomy. J Orthop Res 25:311–318CrossRefPubMedPubMedCentral Briem K, Ramsey DK, Newcomb W, Rudolph KS, Snyder-Mackler L (2007) Effects of the amount of valgus correction for medial compartment knee osteoarthritis on clinical outcome, knee kinetics and muscle co-contraction after opening wedge high tibial osteotomy. J Orthop Res 25:311–318CrossRefPubMedPubMedCentral
9.
go back to reference Brinkman J-M, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ (2008) Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg Br 90:1548–1557CrossRefPubMed Brinkman J-M, Lobenhoffer P, Agneskirchner JD, Staubli AE, Wymenga AB, van Heerwaarden RJ (2008) Osteotomies around the knee: patient selection, stability of fixation and bone healing in high tibial osteotomies. J Bone Joint Surg Br 90:1548–1557CrossRefPubMed
10.
go back to reference Collins NJ, Misra D, Felson DT, Crossley KM, Roos EM (2011) Measures of knee function: International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form, Knee Injury and Osteoarthritis Outcome Score (KOOS), Knee Injury and Osteoarthritis Outcome Score Physical Function Short Form (KOOS-PS), Knee Outcome Survey Activities of Daily Living Scale (KOS-ADL), Lysholm Knee Scoring Scale, Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Activity Rating Scale (ARS), and Tegner Activity Score (TAS). Arthritis Care Res 11:S208–S228CrossRef Collins NJ, Misra D, Felson DT, Crossley KM, Roos EM (2011) Measures of knee function: International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form, Knee Injury and Osteoarthritis Outcome Score (KOOS), Knee Injury and Osteoarthritis Outcome Score Physical Function Short Form (KOOS-PS), Knee Outcome Survey Activities of Daily Living Scale (KOS-ADL), Lysholm Knee Scoring Scale, Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Activity Rating Scale (ARS), and Tegner Activity Score (TAS). Arthritis Care Res 11:S208–S228CrossRef
11.
go back to reference Coventry MB (1965) Osteotomy of the upper portion of the tibia for degenerative arthritis of the knee. A preliminary report. J Bone Joint Surg Am 47:984–990CrossRefPubMed Coventry MB (1965) Osteotomy of the upper portion of the tibia for degenerative arthritis of the knee. A preliminary report. J Bone Joint Surg Am 47:984–990CrossRefPubMed
12.
go back to reference Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75:196–201CrossRefPubMed Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75:196–201CrossRefPubMed
13.
go back to reference DeMeo PJ, Johnson EM, Chiang PP, Flamm AM, Miller MC (2010) Midterm Follow-up of Opening-Wedge High Tibial Osteotomy. Am J Sports Med 38:2077–2084CrossRefPubMed DeMeo PJ, Johnson EM, Chiang PP, Flamm AM, Miller MC (2010) Midterm Follow-up of Opening-Wedge High Tibial Osteotomy. Am J Sports Med 38:2077–2084CrossRefPubMed
14.
go back to reference Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 274:248–264 Dugdale TW, Noyes FR, Styer D (1992) Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length. Clin Orthop Relat Res 274:248–264
15.
go back to reference Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10:585–608PubMed
16.
go back to reference Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354CrossRefPubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69:332–354CrossRefPubMed
17.
go back to reference Lee MM, Song CH, Lee KJ, Jung SW, Shin DC, Shin SH (2014) Concurrent validity and test-retest reliability of the OPTOGait photoelectric cell system for the assessment of spatio-temporal parameters of the gait of young adults. J Phys Ther Sci 26:81–85CrossRefPubMedPubMedCentral Lee MM, Song CH, Lee KJ, Jung SW, Shin DC, Shin SH (2014) Concurrent validity and test-retest reliability of the OPTOGait photoelectric cell system for the assessment of spatio-temporal parameters of the gait of young adults. J Phys Ther Sci 26:81–85CrossRefPubMedPubMedCentral
18.
go back to reference Leitch KM, Birmingham TB, Dunning CE, Giffin JR (2015) Medial opening wedge high tibial osteotomy alters knee moments in multiple planes during walking and stair ascent. Gait Posture 42:165–171CrossRefPubMed Leitch KM, Birmingham TB, Dunning CE, Giffin JR (2015) Medial opening wedge high tibial osteotomy alters knee moments in multiple planes during walking and stair ascent. Gait Posture 42:165–171CrossRefPubMed
19.
go back to reference Lind M, McClelland J, Wittwer JE, Whitehead TS, Feller JA, Webster KE (2011) Gait analysis of walking before and after medial opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:74–81CrossRefPubMed Lind M, McClelland J, Wittwer JE, Whitehead TS, Feller JA, Webster KE (2011) Gait analysis of walking before and after medial opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21:74–81CrossRefPubMed
20.
go back to reference Lootvoet L, Massinon A, Rossillon R, Himmer O, Lambert K, Ghosez JP (1993) Upper tibial osteotomy for gonarthrosis in genu varum. Apropos of a series of 193 cases reviewed 6 to 10 years later. Rev Chir Orthop 79:375–384PubMed Lootvoet L, Massinon A, Rossillon R, Himmer O, Lambert K, Ghosez JP (1993) Upper tibial osteotomy for gonarthrosis in genu varum. Apropos of a series of 193 cases reviewed 6 to 10 years later. Rev Chir Orthop 79:375–384PubMed
21.
go back to reference Majima T, Yasuda K, Katsuragi R, Kaneda K (2000) Progression of joint arthrosis 10 to 15 years after high tibial osteotomy. Clin Orthop Relat Res 381:177–184CrossRef Majima T, Yasuda K, Katsuragi R, Kaneda K (2000) Progression of joint arthrosis 10 to 15 years after high tibial osteotomy. Clin Orthop Relat Res 381:177–184CrossRef
22.
go back to reference Mündermann A, Dyrby CO, Hurwitz DE, Sharma L, Andriacchi TP (2004) Potential strategies to reduce medial compartment loading in patients with knee osteoarthritis of varying severity: reduced walking speed. Arthritis Rheum 50:1172–1178CrossRefPubMed Mündermann A, Dyrby CO, Hurwitz DE, Sharma L, Andriacchi TP (2004) Potential strategies to reduce medial compartment loading in patients with knee osteoarthritis of varying severity: reduced walking speed. Arthritis Rheum 50:1172–1178CrossRefPubMed
23.
go back to reference Ornetti P, Maillefert J-F, Laroche D, Morisset C, Dougados M, Gossec L (2010) Gait analysis as a quantifiable outcome measure in hip or knee osteoarthritis: a systematic review. Joint Bone Spine 77:421–425CrossRefPubMed Ornetti P, Maillefert J-F, Laroche D, Morisset C, Dougados M, Gossec L (2010) Gait analysis as a quantifiable outcome measure in hip or knee osteoarthritis: a systematic review. Joint Bone Spine 77:421–425CrossRefPubMed
24.
go back to reference Prodromos CC, Andriacchi TP, Galante JO (1985) A relationship between gait and clinical changes following high tibial osteotomy. J Bone Joint Surg Am 67:1188–1194CrossRefPubMed Prodromos CC, Andriacchi TP, Galante JO (1985) A relationship between gait and clinical changes following high tibial osteotomy. J Bone Joint Surg Am 67:1188–1194CrossRefPubMed
25.
go back to reference Ramsey DK, Snyder-Mackler L, Lewek M, Newcomb W, Rudolph KS (2007) Effect of anatomic realignment on muscle function during gait in patients with medial compartment knee osteoarthritis. Arthritis Rheum 57:389–397CrossRefPubMedPubMedCentral Ramsey DK, Snyder-Mackler L, Lewek M, Newcomb W, Rudolph KS (2007) Effect of anatomic realignment on muscle function during gait in patients with medial compartment knee osteoarthritis. Arthritis Rheum 57:389–397CrossRefPubMedPubMedCentral
26.
go back to reference Saragaglia D, Blaysat M, Inman D, Mercier N (2011) Outcome of opening wedge high tibial osteotomy augmented with a Biosorb® wedge and fixed with a plate and screws in 124 patients with a mean of ten years follow-up. Int Orthop 35:1151–1156CrossRefPubMed Saragaglia D, Blaysat M, Inman D, Mercier N (2011) Outcome of opening wedge high tibial osteotomy augmented with a Biosorb® wedge and fixed with a plate and screws in 124 patients with a mean of ten years follow-up. Int Orthop 35:1151–1156CrossRefPubMed
27.
go back to reference Saragaglia D, Chedal-Bornu B, Rouchy RC, Rubens-Duval B, Mader R, Pailhé R (2016) Role of computer-assisted surgery in osteotomies around the knee. Knee Surg Sports Traumatol Arthrosc 24:3387–3395CrossRefPubMed Saragaglia D, Chedal-Bornu B, Rouchy RC, Rubens-Duval B, Mader R, Pailhé R (2016) Role of computer-assisted surgery in osteotomies around the knee. Knee Surg Sports Traumatol Arthrosc 24:3387–3395CrossRefPubMed
28.
go back to reference Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–74PubMed Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopedics 28:s1269–74PubMed
29.
go back to reference Saragaglia D, Rouchy R-C, Krayan A, Refaie R (2014) Return to sports after valgus osteotomy of the knee joint in patients with medial unicompartmental osteoarthritis. Int Orthop 38:2109–2114CrossRefPubMed Saragaglia D, Rouchy R-C, Krayan A, Refaie R (2014) Return to sports after valgus osteotomy of the knee joint in patients with medial unicompartmental osteoarthritis. Int Orthop 38:2109–2114CrossRefPubMed
30.
go back to reference Schröter S, Mueller J, van Heerwaarden R, Lobenhoffer P, Stöckle U, Albrecht D (2013) Return to work and clinical outcome after open wedge HTO. Knee Surg Sports Traumatol Arthrosc 21:213–219CrossRefPubMed Schröter S, Mueller J, van Heerwaarden R, Lobenhoffer P, Stöckle U, Albrecht D (2013) Return to work and clinical outcome after open wedge HTO. Knee Surg Sports Traumatol Arthrosc 21:213–219CrossRefPubMed
31.
go back to reference Sharma L (2007) The role of varus and valgus alignment in knee osteoarthritis. Arthritis Rheum 56:1044–1047CrossRefPubMed Sharma L (2007) The role of varus and valgus alignment in knee osteoarthritis. Arthritis Rheum 56:1044–1047CrossRefPubMed
32.
go back to reference Sischek EL, Birmingham TB, Leitch KM, Martin R, Willits K, Giffin JR (2014) Staged medial opening wedge high tibial osteotomy for bilateral varus gonarthrosis: biomechanical and clinical outcomes. Knee Surg Sports Traumatol Arthrosc 22:2672–2681CrossRefPubMed Sischek EL, Birmingham TB, Leitch KM, Martin R, Willits K, Giffin JR (2014) Staged medial opening wedge high tibial osteotomy for bilateral varus gonarthrosis: biomechanical and clinical outcomes. Knee Surg Sports Traumatol Arthrosc 22:2672–2681CrossRefPubMed
33.
go back to reference Turcot K, Armand S, Lübbeke A, Fritschy D, Hoffmeyer P, Suvà D (2013) Does knee alignment influence gait in patients with severe knee osteoarthritis? Clin Biomech 28:34–39CrossRef Turcot K, Armand S, Lübbeke A, Fritschy D, Hoffmeyer P, Suvà D (2013) Does knee alignment influence gait in patients with severe knee osteoarthritis? Clin Biomech 28:34–39CrossRef
34.
go back to reference Van Egmond N, Van Grinsven S, Van Loon CJ, Gaasbeek RD, Van Kampen A (2016) Better clinical results after closd- compared to open-wedge high tibial osteotomy in patients with medial knee osteoarthritis and varus leg alignment. Knee Surg Sports Traumatol Arthros 24:34–41CrossRef Van Egmond N, Van Grinsven S, Van Loon CJ, Gaasbeek RD, Van Kampen A (2016) Better clinical results after closd- compared to open-wedge high tibial osteotomy in patients with medial knee osteoarthritis and varus leg alignment. Knee Surg Sports Traumatol Arthros 24:34–41CrossRef
35.
go back to reference Wada M, Imura S, Nagatani K, Baba H, Shimada S, Sasaki S (1998) Relationship between gait and clinical results after high tibial osteotomy. Clin Orthop Relat Res 354:180–188CrossRef Wada M, Imura S, Nagatani K, Baba H, Shimada S, Sasaki S (1998) Relationship between gait and clinical results after high tibial osteotomy. Clin Orthop Relat Res 354:180–188CrossRef
36.
go back to reference Warme BA, Aalderink K, Amendola A (2011) Is There a Role for High Tibial Osteotomies in the Athlete? Sports. Health (London) 3:59–69 Warme BA, Aalderink K, Amendola A (2011) Is There a Role for High Tibial Osteotomies in the Athlete? Sports. Health (London) 3:59–69
37.
go back to reference Weidow J, Tranberg R, Saari T, Kärrholm J (2006) Hip and knee joint rotations differ between patients with medial and lateral knee osteoarthritis: gait analysis of 30 patients and 15 controls. J Orthop Res 24:1890–1899CrossRefPubMed Weidow J, Tranberg R, Saari T, Kärrholm J (2006) Hip and knee joint rotations differ between patients with medial and lateral knee osteoarthritis: gait analysis of 30 patients and 15 controls. J Orthop Res 24:1890–1899CrossRefPubMed
38.
go back to reference Wright JM, Crockett HC, Slawski DP, Madsen MW, Windsor RE (2005) High tibial osteotomy. J Am Acad Orthop Surg 13:279–289CrossRefPubMed Wright JM, Crockett HC, Slawski DP, Madsen MW, Windsor RE (2005) High tibial osteotomy. J Am Acad Orthop Surg 13:279–289CrossRefPubMed
Metadata
Title
Gait analysis following medial opening-wedge high tibial osteotomy
Authors
Vincent Morin
Régis Pailhé
Brice Rubens Duval
Roch Mader
Jérémy Cognault
René-Christopher Rouchy
Dominique Saragaglia
Publication date
01-06-2018
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 6/2018
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-017-4421-1

Other articles of this Issue 6/2018

Knee Surgery, Sports Traumatology, Arthroscopy 6/2018 Go to the issue