Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 9/2016

01-09-2016 | Knee

Preparation techniques for all-inside ACL cortical button grafts: a biomechanical study

Authors: Raul Mayr, Christian Heinz Heinrichs, Martin Eichinger, Vinzenz Smekal, Werner Schmoelz, René Attal

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 9/2016

Login to get access

Abstract

Purpose

Performing all-inside anterior cruciate ligament reconstruction using cortical button fixation, the tendon graft has to be secured in a closed loop with sutures. In the present study, the graft secured with four sutures was compared with two reduced-suture material graft preparation techniques.

Methods

A bovine tendon graft folded over two adjustable-length loop cortical button devices was secured using the following techniques: 1, four buried-knot sutures; 2, two sutures on the tibial end only; and 3, two sutures on the tibial graft end with additional suspension on the tibial cortical button. Each group consisted of eight specimens and underwent cyclic loading followed by a load-to-failure test.

Results

The least graft elongation after cyclic loading was observed for the graft with four sutures (6.1 ± 0.6 mm), followed by the graft with two sutures and additional suspension (6.3 ± 0.8 mm) and the graft with two sutures (7.0 ± 0.7 mm). The difference in graft elongation between four sutures and only two sutures was significant (P < 0.05). The ultimate failure loads were highest for the graft with two sutures and additional suspension (801 ± 107 N), followed by the graft with four sutures (766 ± 70 N), and the graft with two sutures (699 ± 87 N). No significant (n.s.) differences were observed between the ultimate failure loads in the three groups.

Conclusions

For the reduction in suture material to two sutures, additional suspension can be used in order to reduce the graft lengthening. Performing a suture-reducing graft can save operating time and costs. However, each of the three all-inside button graft techniques showed considerable graft elongation indicating a risk of graft lengthening in the early postoperative period.
Literature
1.
go back to reference Aga C, Rasmussen MT, Smith SD, Jansson KS, LaPrade RF, Engebretsen L, Wijdicks CA (2013) Biomechanical comparison of interference screws and combination screw and sheath devices for soft tissue anterior cruciate ligament reconstruction on the tibial side. Am J Sports Med 41:841–848CrossRefPubMed Aga C, Rasmussen MT, Smith SD, Jansson KS, LaPrade RF, Engebretsen L, Wijdicks CA (2013) Biomechanical comparison of interference screws and combination screw and sheath devices for soft tissue anterior cruciate ligament reconstruction on the tibial side. Am J Sports Med 41:841–848CrossRefPubMed
2.
go back to reference Barrow AE, Pilia M, Guda T, Kadrmas WR, Burns TC (2014) Femoral suspension devices for anterior cruciate ligament reconstruction: do adjustable loops lengthen? Am J Sports Med 42:343–349CrossRefPubMed Barrow AE, Pilia M, Guda T, Kadrmas WR, Burns TC (2014) Femoral suspension devices for anterior cruciate ligament reconstruction: do adjustable loops lengthen? Am J Sports Med 42:343–349CrossRefPubMed
3.
go back to reference Benea H, d’Astorg H, Klouche S, Bauer T, Tomoaia G, Hardy P (2014) Pain evaluation after all-inside anterior cruciate ligament reconstruction and short term functional results of a prospective randomized study. Knee 21:102–106CrossRefPubMed Benea H, d’Astorg H, Klouche S, Bauer T, Tomoaia G, Hardy P (2014) Pain evaluation after all-inside anterior cruciate ligament reconstruction and short term functional results of a prospective randomized study. Knee 21:102–106CrossRefPubMed
4.
go back to reference Beynnon BD, Johnson RJ, Fleming BC, Kannus P, Kaplan M, Samani J, Renstrom P (2002) Anterior cruciate ligament replacement: comparison of bone-patellar tendon-bone grafts with two-strand hamstring grafts. A prospective, randomized study. J Bone Joint Surg Am 84-A:1503–1513PubMed Beynnon BD, Johnson RJ, Fleming BC, Kannus P, Kaplan M, Samani J, Renstrom P (2002) Anterior cruciate ligament replacement: comparison of bone-patellar tendon-bone grafts with two-strand hamstring grafts. A prospective, randomized study. J Bone Joint Surg Am 84-A:1503–1513PubMed
5.
go back to reference Brown CH Jr, Wilson DR, Hecker AT, Ferragamo M (2004) Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading. Arthroscopy 20:922–935CrossRefPubMed Brown CH Jr, Wilson DR, Hecker AT, Ferragamo M (2004) Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading. Arthroscopy 20:922–935CrossRefPubMed
6.
go back to reference Caborn DN, Brand JC Jr, Nyland J, Kocabey Y (2004) A biomechanical comparison of initial soft tissue tibial fixation devices: the Intrafix versus a tapered 35-mm bioabsorbable interference screw. Am J Sports Med 32:956–961CrossRefPubMed Caborn DN, Brand JC Jr, Nyland J, Kocabey Y (2004) A biomechanical comparison of initial soft tissue tibial fixation devices: the Intrafix versus a tapered 35-mm bioabsorbable interference screw. Am J Sports Med 32:956–961CrossRefPubMed
7.
go back to reference Camarda L, Pitarresi G, Moscadini S, Marannano G, Sanfilippo A, D’Arienzo M (2014) Effect of suturing the femoral portion of a four-strand graft during an ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 22:1040–1046CrossRefPubMed Camarda L, Pitarresi G, Moscadini S, Marannano G, Sanfilippo A, D’Arienzo M (2014) Effect of suturing the femoral portion of a four-strand graft during an ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 22:1040–1046CrossRefPubMed
8.
go back to reference Cerulli G, Zamarra G, Vercillo F, Pelosi F (2011) ACL reconstruction with “the original all-inside technique”. Knee Surg Sports Traumatol Arthrosc 19:829–831CrossRefPubMed Cerulli G, Zamarra G, Vercillo F, Pelosi F (2011) ACL reconstruction with “the original all-inside technique”. Knee Surg Sports Traumatol Arthrosc 19:829–831CrossRefPubMed
9.
go back to reference Donahue TL, Gregersen C, Hull ML, Howell SM (2001) Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons. J Biomech Eng 123:162–169CrossRefPubMed Donahue TL, Gregersen C, Hull ML, Howell SM (2001) Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons. J Biomech Eng 123:162–169CrossRefPubMed
10.
go back to reference Greis PE, Burks RT, Bachus K, Luker MG (2001) The influence of tendon length and fit on the strength of a tendon-bone tunnel complex. A biomechanical and histologic study in the dog. Am J Sports Med 29:493–497PubMed Greis PE, Burks RT, Bachus K, Luker MG (2001) The influence of tendon length and fit on the strength of a tendon-bone tunnel complex. A biomechanical and histologic study in the dog. Am J Sports Med 29:493–497PubMed
11.
go back to reference Hoher J, Scheffler SU, Withrow JD, Livesay GA, Debski RE, Fu FH, Woo SL (2000) Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 18:456–461CrossRefPubMed Hoher J, Scheffler SU, Withrow JD, Livesay GA, Debski RE, Fu FH, Woo SL (2000) Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 18:456–461CrossRefPubMed
13.
go back to reference Micucci CJ, Frank DA, Kompel J, Muffly M, Demeo PJ, Altman GT (2010) The effect of interference screw diameter on fixation of soft-tissue grafts in anterior cruciate ligament reconstruction. Arthroscopy 26:1105–1110CrossRefPubMed Micucci CJ, Frank DA, Kompel J, Muffly M, Demeo PJ, Altman GT (2010) The effect of interference screw diameter on fixation of soft-tissue grafts in anterior cruciate ligament reconstruction. Arthroscopy 26:1105–1110CrossRefPubMed
14.
go back to reference Nurmi JT, Kannus P, Sievanen H, Jarvela T, Jarvinen M, Jarvinen TL (2004) Interference screw fixation of soft tissue grafts in anterior cruciate ligament reconstruction: part 1: effect of tunnel compaction by serial dilators versus extraction drilling on the initial fixation strength. Am J Sports Med 32:411–417CrossRefPubMed Nurmi JT, Kannus P, Sievanen H, Jarvela T, Jarvinen M, Jarvinen TL (2004) Interference screw fixation of soft tissue grafts in anterior cruciate ligament reconstruction: part 1: effect of tunnel compaction by serial dilators versus extraction drilling on the initial fixation strength. Am J Sports Med 32:411–417CrossRefPubMed
15.
go back to reference O’Neill DB (2004) Revision arthroscopically assisted anterior cruciate ligament reconstruction with previously unharvested ipsilateral autografts. Am J Sports Med 32:1833–1841CrossRefPubMed O’Neill DB (2004) Revision arthroscopically assisted anterior cruciate ligament reconstruction with previously unharvested ipsilateral autografts. Am J Sports Med 32:1833–1841CrossRefPubMed
16.
go back to reference Petre BM, Smith SD, Jansson KS, de Meijer PP, Hackett TR, LaPrade RF, Wijdicks CA (2013) Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study. Am J Sports Med 41:416–422CrossRefPubMed Petre BM, Smith SD, Jansson KS, de Meijer PP, Hackett TR, LaPrade RF, Wijdicks CA (2013) Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study. Am J Sports Med 41:416–422CrossRefPubMed
17.
go back to reference Walsh MP, Wijdicks CA, Parker JB, Hapa O, LaPrade RF (2009) A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model. Am J Sports Med 37:160–167CrossRefPubMed Walsh MP, Wijdicks CA, Parker JB, Hapa O, LaPrade RF (2009) A comparison between a retrograde interference screw, suture button, and combined fixation on the tibial side in an all-inside anterior cruciate ligament reconstruction: a biomechanical study in a porcine model. Am J Sports Med 37:160–167CrossRefPubMed
18.
go back to reference Weiler A, Schmeling A, Stohr I, Kaab MJ, Wagner M (2007) Primary versus single-stage revision anterior cruciate ligament reconstruction using autologous hamstring tendon grafts: a prospective matched-group analysis. Am J Sports Med 35:1643–1652CrossRefPubMed Weiler A, Schmeling A, Stohr I, Kaab MJ, Wagner M (2007) Primary versus single-stage revision anterior cruciate ligament reconstruction using autologous hamstring tendon grafts: a prospective matched-group analysis. Am J Sports Med 35:1643–1652CrossRefPubMed
19.
go back to reference Zamarra G, Fisher MB, Woo SL, Cerulli G (2010) Biomechanical evaluation of using one hamstrings tendon for ACL reconstruction: a human cadaveric study. Knee Surg Sports Traumatol Arthrosc 18:11–19CrossRefPubMed Zamarra G, Fisher MB, Woo SL, Cerulli G (2010) Biomechanical evaluation of using one hamstrings tendon for ACL reconstruction: a human cadaveric study. Knee Surg Sports Traumatol Arthrosc 18:11–19CrossRefPubMed
Metadata
Title
Preparation techniques for all-inside ACL cortical button grafts: a biomechanical study
Authors
Raul Mayr
Christian Heinz Heinrichs
Martin Eichinger
Vinzenz Smekal
Werner Schmoelz
René Attal
Publication date
01-09-2016
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 9/2016
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-015-3605-9

Other articles of this Issue 9/2016

Knee Surgery, Sports Traumatology, Arthroscopy 9/2016 Go to the issue