Mobile-bearing prosthesis and intraoperative gap balancing are not predictors of superior knee flexion: a prospective randomized study

Authors: Yukihide Minoda, Hiroyoshi Iwaki, Mitsuhiko Ikebuchi, Taku Yoshida, Shigekazu Mizokawa, Maki Itokazu, Hiroaki Nakamura

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 7/2015

Login to get access

Abstract

Purpose

Range of motion is a crucial measure of the outcome of total knee arthroplasty. Gap balancing technique and mobile-bearing prosthesis can improve postoperative range of motion. The purpose of this study was to determine the factors that are predictive of the postoperative range of motion.

Methods

A total of 94 knees with varus osteoarthritis were prospectively randomized to receive either a posterior-stabilized mobile-bearing or a posterior-stabilized fixed-bearing prosthesis. All preoperative and postoperative protocols and operative techniques were identical in the two groups. Extension and flexion joint gaps were measured using a tensor device during the operation. Multiple regression analysis was conducted to determine the best predictors of the knee flexion angle 2 years after the operation. The independent variables were type of prosthesis (mobile-bearing or fixed-bearing), difference between flexion and extension joint gaps (mm), age, gender, body mass index (BMI), preoperative and intraoperative knee flexion angles, change in posterior condylar offset, and posterior tilt of the tibial plateau.

Results

The mean difference between flexion and extension joint gaps was 0.8 ± 1.3 (mean ± SD) mm for mobile-bearing and 0.8 ± 1.9 mm for fixed-bearing prosthesis. The mean flexion angle for mobile-bearing and fixed-bearing groups was 120 ± 16° and 116 ± 20° preoperatively (n.s.), 142 ± 9° and 141 ± 12° intraoperatively (n.s.), and 129 ± 10° and 128 ± 13° at 2 years postoperatively (p = 0.773), respectively. Predictors were identified in the following three categories: (1) preoperative flexion angle, (2) intraoperative radiographic flexion angle, and (3) BMI (R = 0.603, p < 0.001).

Conclusions

Mobile-bearing prosthesis and optimal gap balancing did not result in superior postoperative flexion angle. Better preoperative and intraoperative flexion angles and lower BMI were the significant predictors for better postoperative flexion angle.

Level of evidence

Therapeutic study, Level I.
Literature
1.
go back to reference Acker SM, Cockburn RA, Krevolin J et al (2011) Knee kinematics of high-flexion activities of daily living performed by male Muslims in the Middle East. J Arthroplasty 26:319–327PubMedCrossRef Acker SM, Cockburn RA, Krevolin J et al (2011) Knee kinematics of high-flexion activities of daily living performed by male Muslims in the Middle East. J Arthroplasty 26:319–327PubMedCrossRef
2.
go back to reference Asano H, Hoshino A, Wilton TJ (2004) Soft-tissue tension total knee arthroplasty. J Arthroplasty 19:558–561PubMedCrossRef Asano H, Hoshino A, Wilton TJ (2004) Soft-tissue tension total knee arthroplasty. J Arthroplasty 19:558–561PubMedCrossRef
3.
go back to reference Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Jt Surg 84-B:50–53CrossRef Bellemans J, Banks S, Victor J, Vandenneucker H, Moemans A (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Jt Surg 84-B:50–53CrossRef
4.
go back to reference Bistolfi A, Massazza G, Lee GC, Deledda D, Berchialla P, Crova M (2013) Comparison of fixed and mobile-bearing total knee arthroplasty at a mean follow-up of 116 months. J Bone Jt Surg 95-A:e83. doi:10.2106/JBJS.L.00327 Bistolfi A, Massazza G, Lee GC, Deledda D, Berchialla P, Crova M (2013) Comparison of fixed and mobile-bearing total knee arthroplasty at a mean follow-up of 116 months. J Bone Jt Surg 95-A:e83. doi:10.​2106/​JBJS.​L.​00327
5.
go back to reference Callaghan JJ, Insall JN, Greenwald AS et al (2001) Mobile bearing knee replacement: concepts and results. Instr Course Lect 50:431–449PubMed Callaghan JJ, Insall JN, Greenwald AS et al (2001) Mobile bearing knee replacement: concepts and results. Instr Course Lect 50:431–449PubMed
6.
go back to reference Chen LB, Tan Y, Al-Aidaros M, Wang H, Wang X, Cai SH (2013) Comparison of functional performance after total knee arthroplasty using rotating platform and fixed-bearing prostheses with or without patellar resurfacing. Orthop Surg 5:112–117PubMedCrossRef Chen LB, Tan Y, Al-Aidaros M, Wang H, Wang X, Cai SH (2013) Comparison of functional performance after total knee arthroplasty using rotating platform and fixed-bearing prostheses with or without patellar resurfacing. Orthop Surg 5:112–117PubMedCrossRef
7.
go back to reference Delport HP, Banks SA, De Schepper J et al (2006) A kinematic comparison of fixed-and mobile-bearing knee replacements. J Bone Jt Surg 88-B:1016–1021CrossRef Delport HP, Banks SA, De Schepper J et al (2006) A kinematic comparison of fixed-and mobile-bearing knee replacements. J Bone Jt Surg 88-B:1016–1021CrossRef
8.
go back to reference Dennis DA, Komistek RD, Scuderi GR, Zingde S (2007) Factors affecting flexion after total knee arthroplasty. Clin Orthop Relat Res 464:53–60PubMed Dennis DA, Komistek RD, Scuderi GR, Zingde S (2007) Factors affecting flexion after total knee arthroplasty. Clin Orthop Relat Res 464:53–60PubMed
9.
go back to reference Dennis DA, Komistek RD, Kim RH, Sharma A (2010) Gap balancing versus measured resection technique for total knee arthroplasty. Clin Orthop Relat Res 468:102–107PubMedCentralPubMedCrossRef Dennis DA, Komistek RD, Kim RH, Sharma A (2010) Gap balancing versus measured resection technique for total knee arthroplasty. Clin Orthop Relat Res 468:102–107PubMedCentralPubMedCrossRef
10.
go back to reference Ewald FC (1989) The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed Ewald FC (1989) The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12PubMed
11.
go back to reference Harvey IA, Barry K, Kirby SP, Johnson R, Elloy MA (1993) Factors affecting the range of movement of total knee arthroplasty. J Bone Jt Surg 75-B:950–955 Harvey IA, Barry K, Kirby SP, Johnson R, Elloy MA (1993) Factors affecting the range of movement of total knee arthroplasty. J Bone Jt Surg 75-B:950–955
12.
go back to reference Higuchi H, Hatayama K, Shimizu M et al (2009) Relationship between joint gap difference and range of motion in total knee arthroplasty: a prospective randomised study between different platforms. Int Orthop 33:997–1000PubMedCentralPubMedCrossRef Higuchi H, Hatayama K, Shimizu M et al (2009) Relationship between joint gap difference and range of motion in total knee arthroplasty: a prospective randomised study between different platforms. Int Orthop 33:997–1000PubMedCentralPubMedCrossRef
13.
go back to reference Insall J, Dorr L, Scott R, Scott W (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall J, Dorr L, Scott R, Scott W (1989) Rationale of the knee society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
14.
go back to reference Ishii Y, Noguchi H, Takeda M, Sato J, Toyabe S (2011) Prediction of range of motion 2 years after mobile-bearing total knee arthroplasty: PCL-retaining versus PCL-sacrificing. Knee Surg Sports Traumatol Arthrosc 19:2002–2008PubMedCrossRef Ishii Y, Noguchi H, Takeda M, Sato J, Toyabe S (2011) Prediction of range of motion 2 years after mobile-bearing total knee arthroplasty: PCL-retaining versus PCL-sacrificing. Knee Surg Sports Traumatol Arthrosc 19:2002–2008PubMedCrossRef
15.
go back to reference Jennings LM, Bell CI, Ingham E et al (2007) The influence of femoral condylar lift-off on the wear of artificial knee joints. Proc Inst Mech Eng H 221:305–314PubMedCrossRef Jennings LM, Bell CI, Ingham E et al (2007) The influence of femoral condylar lift-off on the wear of artificial knee joints. Proc Inst Mech Eng H 221:305–314PubMedCrossRef
17.
go back to reference Koshino T, Tsuchiya K (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. Clinical and histological observations. Int Orthop 3:37–451PubMedCrossRef Koshino T, Tsuchiya K (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. Clinical and histological observations. Int Orthop 3:37–451PubMedCrossRef
18.
go back to reference Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25:458–464PubMedCrossRef Kim TK, Kwon SK, Kang YG, Chang CB, Seong SC (2010) Functional disabilities and satisfaction after total knee arthroplasty in female Asian patients. J Arthroplasty 25:458–464PubMedCrossRef
19.
go back to reference Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Jt Surg 87-A:1470–1475CrossRef Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Jt Surg 87-A:1470–1475CrossRef
20.
go back to reference Kurita M, Tomita T, Yamazaki T et al (2012) In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion. Int Orthop 36:2465–2471PubMedCentralPubMedCrossRef Kurita M, Tomita T, Yamazaki T et al (2012) In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion. Int Orthop 36:2465–2471PubMedCentralPubMedCrossRef
21.
go back to reference Lee DH, Lee DK, Shin YS, Han SB (2013) Influence of gap balance on the sagittal movement of a specific mobile bearing floating platform design in total knee arthroplasty. J Arthroplasty. doi:10.1016/j.arth.2013.04.019 Lee DH, Lee DK, Shin YS, Han SB (2013) Influence of gap balance on the sagittal movement of a specific mobile bearing floating platform design in total knee arthroplasty. J Arthroplasty. doi:10.​1016/​j.​arth.​2013.​04.​019
22.
go back to reference Matsuda S, Kawahara S, Okazaki K, Tashiro Y, Iwamoto Y (2013) Postoperative alignment and ROM affect patient satisfaction after TKA. Clin Orthop Relat Res 471:127–133PubMedCentralPubMedCrossRef Matsuda S, Kawahara S, Okazaki K, Tashiro Y, Iwamoto Y (2013) Postoperative alignment and ROM affect patient satisfaction after TKA. Clin Orthop Relat Res 471:127–133PubMedCentralPubMedCrossRef
23.
go back to reference Matsumoto T, Kuroda R, Kubo S et al (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Jt Surg 91-B:475–480CrossRef Matsumoto T, Kuroda R, Kubo S et al (2009) The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement. J Bone Jt Surg 91-B:475–480CrossRef
24.
go back to reference Matsumoto T, Muratsu H, Kubo S et al (2011) Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:880–886PubMedCrossRef Matsumoto T, Muratsu H, Kubo S et al (2011) Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:880–886PubMedCrossRef
25.
go back to reference Matziolis G, Pfiel S, Wassilew G, Boenicke H, Perka C (2011) Kinematic analysis of the flexion axis for correct femoral component placement. Knee Surg Sports Traumatol Arthrosc 19:1504–1509PubMedCrossRef Matziolis G, Pfiel S, Wassilew G, Boenicke H, Perka C (2011) Kinematic analysis of the flexion axis for correct femoral component placement. Knee Surg Sports Traumatol Arthrosc 19:1504–1509PubMedCrossRef
26.
go back to reference Minoda Y, Iwaki H, Ikebuchi M, Yoshida T, Nakamura H (2012) The flexion gap preparation does not disturb the modified gap technique in posterior stabilized total knee arthroplasty. Knee 19:832–835PubMedCrossRef Minoda Y, Iwaki H, Ikebuchi M, Yoshida T, Nakamura H (2012) The flexion gap preparation does not disturb the modified gap technique in posterior stabilized total knee arthroplasty. Knee 19:832–835PubMedCrossRef
27.
go back to reference Pang HN, Yeo SJ, Chong HC et al (2011) Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc 19:1496–1503PubMedCrossRef Pang HN, Yeo SJ, Chong HC et al (2011) Computer-assisted gap balancing technique improves outcome in total knee arthroplasty, compared with conventional measured resection technique. Knee Surg Sports Traumatol Arthrosc 19:1496–1503PubMedCrossRef
28.
go back to reference Parsley BS, Engh GA, Dwyer KA (1992) Preoperative flexion. Does it influence postoperative flexion after posterior-cruciate-retaining total knee arthroplasty? Clin Orthop Relat Res 275:204–210PubMed Parsley BS, Engh GA, Dwyer KA (1992) Preoperative flexion. Does it influence postoperative flexion after posterior-cruciate-retaining total knee arthroplasty? Clin Orthop Relat Res 275:204–210PubMed
29.
go back to reference Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME (2003) Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Jt Surg 85-A:1278–1285 Ritter MA, Harty LD, Davis KE, Meding JB, Berend ME (2003) Predicting range of motion after total knee arthroplasty. Clustering, log-linear regression, and regression tree analysis. J Bone Jt Surg 85-A:1278–1285
30.
go back to reference Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 2:95–97PubMedCrossRef Ritter MA, Campbell ED (1987) Effect of range of motion on the success of a total knee arthroplasty. J Arthroplasty 2:95–97PubMedCrossRef
31.
go back to reference Ritter MA, Stringer EA (1979) Predictive range of motion after total knee replacement. Clin Orthop Relat Res 143:115–119PubMed Ritter MA, Stringer EA (1979) Predictive range of motion after total knee replacement. Clin Orthop Relat Res 143:115–119PubMed
32.
go back to reference Russell RD, Huo MH, de Jong L, Jones RE (2013) Preoperative flexion does not influence postoperative flexion after rotating-platform total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-013-2378-2 Russell RD, Huo MH, de Jong L, Jones RE (2013) Preoperative flexion does not influence postoperative flexion after rotating-platform total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-013-2378-2
33.
go back to reference Sansone V, de Gama Malchèr M (2004) Mobile-bearing total knee prosthesis: a 5- to 9-year follow-up of the first 110 consecutive arthroplasties. J Arthroplasty 219:678–685CrossRef Sansone V, de Gama Malchèr M (2004) Mobile-bearing total knee prosthesis: a 5- to 9-year follow-up of the first 110 consecutive arthroplasties. J Arthroplasty 219:678–685CrossRef
34.
go back to reference Smith H, Jan M, Mahomed NN, Davey JR, Gandhi R (2011) Meta-analysis and systematic review of clinical outcomes comparing mobile bearing and fixed bearing total knee arthroplasty. J Arthroplasty 26:1205–1213PubMedCrossRef Smith H, Jan M, Mahomed NN, Davey JR, Gandhi R (2011) Meta-analysis and systematic review of clinical outcomes comparing mobile bearing and fixed bearing total knee arthroplasty. J Arthroplasty 26:1205–1213PubMedCrossRef
35.
go back to reference Smith TO, Ejtehadi F, Nichols R et al (2010) Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 18:325–340PubMedCrossRef Smith TO, Ejtehadi F, Nichols R et al (2010) Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc 18:325–340PubMedCrossRef
36.
go back to reference Tibesku CO, Daniilidis K, Vieth V et al (2011) Sagittal plane kinematics of fixed- and mobile-bearing total knee replacements. Knee Surg Sports Traumatol Arthrosc 19:1488–1495PubMedCrossRef Tibesku CO, Daniilidis K, Vieth V et al (2011) Sagittal plane kinematics of fixed- and mobile-bearing total knee replacements. Knee Surg Sports Traumatol Arthrosc 19:1488–1495PubMedCrossRef
37.
go back to reference Wen Y, Liu D, Huang Y, Li B (2011) A meta-analysis of the fixed-bearing and mobile-bearing prostheses in total knee arthroplasty. Arch Orthop Trauma Surg 131:1341–1350PubMedCrossRef Wen Y, Liu D, Huang Y, Li B (2011) A meta-analysis of the fixed-bearing and mobile-bearing prostheses in total knee arthroplasty. Arch Orthop Trauma Surg 131:1341–1350PubMedCrossRef
Metadata
Title
Mobile-bearing prosthesis and intraoperative gap balancing are not predictors of superior knee flexion: a prospective randomized study
Authors
Yukihide Minoda
Hiroyoshi Iwaki
Mitsuhiko Ikebuchi
Taku Yoshida
Shigekazu Mizokawa
Maki Itokazu
Hiroaki Nakamura
Publication date
01-07-2015
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 7/2015
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-014-2838-3

Other articles of this Issue 7/2015

Knee Surgery, Sports Traumatology, Arthroscopy 7/2015 Go to the issue