Purpose

Operative treatment for middle-third clavicle fractures has been increasing as recent data has demonstrated growing patient dissatisfaction and functional deficits after non-operative management. A controlled biomechanical comparison of the characteristics of locked intramedullary (IM) fixation versus superior pre-contoured plating for fracture repair and hardware removal is warranted. Therefore, the purpose of the present study was to investigate potential differences between these devices in a biomechanical model.

Methods

Thirty fourth-generation composite clavicles were randomized to one of five groups with 6 specimens each and tested in a random order. The groups tested were intact, repair with plate, repair with IM device, plate removal, and IM device removal. The lateral end of the clavicles was loaded to failure at a rate of 60 mm/min in a cantilever bending setup. Failure mechanism, energy (J), and torque (Nm) at the site of failure were recorded.

Results

Failure torque of the intact clavicle (mean ± standard deviation) was 36.5 ± 7.3 Nm. Failure torques of the IM repair (21.5 ± 9.0 Nm) and plate repair (18.2 ± 1.6 Nm) were not significantly different (n.s.) but were significantly less than the intact group (P < 0.05). Failure torque following IM device removal (30.2 ± 6.5 Nm) was significantly greater than plate removal (12.9 ± 2.0 Nm) (P < 0.05). No significant differences were observed between the intact and IM device removal groups (n.s.).

Conclusion

The results of the current study demonstrate that IM and plate devices provide similar repair strength for middle-third clavicle fractures. However, testing of the hardware removal groups found the IM device removal group to be significantly stronger than the plate removal group.
Literature
1.
go back to reference Altamimi SA, McKee MD (2008) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. Surgical technique. J Bone Joint Surg Am 90(Suppl 2 Pt 1):1–8PubMed Altamimi SA, McKee MD (2008) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. Surgical technique. J Bone Joint Surg Am 90(Suppl 2 Pt 1):1–8PubMed
2.
go back to reference Althausen PL, Shannon S, Lu M, O’Mara TJ, Bray TJ (2012) Clinical and financial comparison of operative and nonoperative treatment of displaced clavicle fractures. J Shoulder Elbow Surg. doi:10.1016/j.jse.2012.06.006 Althausen PL, Shannon S, Lu M, O’Mara TJ, Bray TJ (2012) Clinical and financial comparison of operative and nonoperative treatment of displaced clavicle fractures. J Shoulder Elbow Surg. doi:10.​1016/​j.​jse.​2012.​06.​006
3.
go back to reference Boehme D, Curtis RJ Jr, DeHaan JT, Kay SP, Young DC, Rockwood CA Jr (1993) The treatment of nonunion fractures of the midshaft of the clavicle with an intramedullary Hagie pin and autogenous bone graft. Instr Course Lect 42:283–290PubMed Boehme D, Curtis RJ Jr, DeHaan JT, Kay SP, Young DC, Rockwood CA Jr (1993) The treatment of nonunion fractures of the midshaft of the clavicle with an intramedullary Hagie pin and autogenous bone graft. Instr Course Lect 42:283–290PubMed
4.
go back to reference Bostman O, Manninen M, Pihlajamaki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma 43(5):778–783PubMedCrossRef Bostman O, Manninen M, Pihlajamaki H (1997) Complications of plate fixation in fresh displaced midclavicular fractures. J Trauma 43(5):778–783PubMedCrossRef
5.
go back to reference Canadian Orthopaedic Trauma Society (2007) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89(1):1–10CrossRef Canadian Orthopaedic Trauma Society (2007) Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am 89(1):1–10CrossRef
6.
go back to reference Drosdowech DS, Manwell SE, Ferreira LM, Goel DP, Faber KJ, Johnson JA (2011) Biomechanical analysis of fixation of middle third fractures of the clavicle. J Orthop Trauma 25(1):39–43PubMedCrossRef Drosdowech DS, Manwell SE, Ferreira LM, Goel DP, Faber KJ, Johnson JA (2011) Biomechanical analysis of fixation of middle third fractures of the clavicle. J Orthop Trauma 25(1):39–43PubMedCrossRef
7.
go back to reference Duan X, Zhong G, Cen S, Huang F, Xiang Z (2011) Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials. J Shoulder Elbow Surg 20(6):1008–1015PubMedCrossRef Duan X, Zhong G, Cen S, Huang F, Xiang Z (2011) Plating versus intramedullary pin or conservative treatment for midshaft fracture of clavicle: a meta-analysis of randomized controlled trials. J Shoulder Elbow Surg 20(6):1008–1015PubMedCrossRef
8.
go back to reference Gardner MP, Chong AC, Pollock AG, Wooley PH (2010) Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng 38(3):613–620PubMedCrossRef Gardner MP, Chong AC, Pollock AG, Wooley PH (2010) Mechanical evaluation of large-size fourth-generation composite femur and tibia models. Ann Biomed Eng 38(3):613–620PubMedCrossRef
9.
go back to reference Golish SR, Oliviero JA, Francke EI, Miller MD (2008) A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 3:28PubMedCentralPubMedCrossRef Golish SR, Oliviero JA, Francke EI, Miller MD (2008) A biomechanical study of plate versus intramedullary devices for midshaft clavicle fixation. J Orthop Surg Res 3:28PubMedCentralPubMedCrossRef
10.
go back to reference Heiner AD (2008) Structural properties of fourth-generation composite femurs and tibias. J Biomech 41(15):3282–3284PubMedCrossRef Heiner AD (2008) Structural properties of fourth-generation composite femurs and tibias. J Biomech 41(15):3282–3284PubMedCrossRef
11.
go back to reference Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79(4):537–539PubMedCrossRef Hill JM, McGuire MH, Crosby LA (1997) Closed treatment of displaced middle-third fractures of the clavicle gives poor results. J Bone Joint Surg Br 79(4):537–539PubMedCrossRef
12.
go back to reference Ho KW, Gilbody J, Jameson T, Miles AW (2010) The effect of 4 mm bicortical drill hole defect on bone strength in a pig femur model. Arch Orthop Trauma Surg 130(6):797–802PubMedCrossRef Ho KW, Gilbody J, Jameson T, Miles AW (2010) The effect of 4 mm bicortical drill hole defect on bone strength in a pig femur model. Arch Orthop Trauma Surg 130(6):797–802PubMedCrossRef
13.
go back to reference Hsiao MS, Cameron KL, Huh J, Hsu JR, Benigni M, Whitener JC, Owens BD (2012) Clavicle fractures in the United States military: incidence and characteristics. Mil Med 177(8):970–974PubMedCrossRef Hsiao MS, Cameron KL, Huh J, Hsu JR, Benigni M, Whitener JC, Owens BD (2012) Clavicle fractures in the United States military: incidence and characteristics. Mil Med 177(8):970–974PubMedCrossRef
14.
go back to reference Johnson BA, Fallat LM (1997) The effect of screw holes on bone strength. J Foot Ankle Surg 36(6):446–451PubMedCrossRef Johnson BA, Fallat LM (1997) The effect of screw holes on bone strength. J Foot Ankle Surg 36(6):446–451PubMedCrossRef
15.
go back to reference Khan LA, Bradnock TJ, Scott C, Robinson CM (2009) Fractures of the clavicle. J Bone Joint Surg Am 91(2):447–460PubMedCrossRef Khan LA, Bradnock TJ, Scott C, Robinson CM (2009) Fractures of the clavicle. J Bone Joint Surg Am 91(2):447–460PubMedCrossRef
16.
go back to reference McKee MD, Wild LM, Schemitsch EH (2003) Midshaft malunions of the clavicle. J Bone Joint Surg Am 85-A(5):790–797PubMed McKee MD, Wild LM, Schemitsch EH (2003) Midshaft malunions of the clavicle. J Bone Joint Surg Am 85-A(5):790–797PubMed
17.
go back to reference McKee RC, Whelan DB, Schemitsch EH, McKee MD (2012) Operative versus nonoperative care of displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials. J Bone Joint Surg Am 94(8):675–684PubMedCrossRef McKee RC, Whelan DB, Schemitsch EH, McKee MD (2012) Operative versus nonoperative care of displaced midshaft clavicular fractures: a meta-analysis of randomized clinical trials. J Bone Joint Surg Am 94(8):675–684PubMedCrossRef
18.
go back to reference Millett PJ, Hurst JM, Horan MP, Hawkins RJ (2011) Complications of clavicle fractures treated with intramedullary fixation. J Shoulder Elbow Surg 20(1):86–91PubMedCrossRef Millett PJ, Hurst JM, Horan MP, Hawkins RJ (2011) Complications of clavicle fractures treated with intramedullary fixation. J Shoulder Elbow Surg 20(1):86–91PubMedCrossRef
19.
go back to reference Mueller M, Rangger C, Striepens N, Burger C (2008) Minimally invasive intramedullary nailing of midshaft clavicular fractures using titanium elastic nails. J Trauma 64(6):1528–1534PubMedCrossRef Mueller M, Rangger C, Striepens N, Burger C (2008) Minimally invasive intramedullary nailing of midshaft clavicular fractures using titanium elastic nails. J Trauma 64(6):1528–1534PubMedCrossRef
21.
go back to reference Nordqvist A, Petersson C (1994) The incidence of fractures of the clavicle. Clin Orthop Relat Res 300:127–132PubMed Nordqvist A, Petersson C (1994) The incidence of fractures of the clavicle. Clin Orthop Relat Res 300:127–132PubMed
22.
go back to reference Nowak J, Mallmin H, Larsson S (2000) The aetiology and epidemiology of clavicular fractures. A prospective study during a two-year period in Uppsala, Sweden. Injury 31(5):353–358PubMedCrossRef Nowak J, Mallmin H, Larsson S (2000) The aetiology and epidemiology of clavicular fractures. A prospective study during a two-year period in Uppsala, Sweden. Injury 31(5):353–358PubMedCrossRef
23.
go back to reference Nowak J, Holgersson M, Larsson S (2004) Can we predict long-term sequelae after fractures of the clavicle based on initial findings? A prospective study with nine to ten years of follow-up. J Shoulder Elbow Surg 13(5):479–486PubMedCrossRef Nowak J, Holgersson M, Larsson S (2004) Can we predict long-term sequelae after fractures of the clavicle based on initial findings? A prospective study with nine to ten years of follow-up. J Shoulder Elbow Surg 13(5):479–486PubMedCrossRef
24.
go back to reference Postacchini F, Gumina S, De Santis P, Albo F (2002) Epidemiology of clavicle fractures. J Shoulder Elbow Surg 11(5):452–456PubMedCrossRef Postacchini F, Gumina S, De Santis P, Albo F (2002) Epidemiology of clavicle fractures. J Shoulder Elbow Surg 11(5):452–456PubMedCrossRef
25.
go back to reference Postacchini R, Gumina S, Farsetti P, Postacchini F (2010) Long-term results of conservative management of midshaft clavicle fracture. Int Orthop 34(5):731–736PubMedCentralPubMedCrossRef Postacchini R, Gumina S, Farsetti P, Postacchini F (2010) Long-term results of conservative management of midshaft clavicle fracture. Int Orthop 34(5):731–736PubMedCentralPubMedCrossRef
26.
go back to reference Remiger AR, Miclau T, Lindsey RW (1997) The torsional strength of bones with residual screw holes from plates with unicortical and bicortical purchase. Clin Biomech 12(1):71–73CrossRef Remiger AR, Miclau T, Lindsey RW (1997) The torsional strength of bones with residual screw holes from plates with unicortical and bicortical purchase. Clin Biomech 12(1):71–73CrossRef
27.
go back to reference Renfree T, Conrad B, Wright T (2010) Biomechanical comparison of contemporary clavicle fixation devices. J Hand Surg Am 35(4):639–644PubMedCrossRef Renfree T, Conrad B, Wright T (2010) Biomechanical comparison of contemporary clavicle fixation devices. J Hand Surg Am 35(4):639–644PubMedCrossRef
28.
go back to reference Robinson CM, Cairns DA (2004) Primary nonoperative treatment of displaced lateral fractures of the clavicle. J Bone Joint Surg Am 86-A(4):778–782PubMed Robinson CM, Cairns DA (2004) Primary nonoperative treatment of displaced lateral fractures of the clavicle. J Bone Joint Surg Am 86-A(4):778–782PubMed
29.
go back to reference Rowe CR (1968) An atlas of anatomy and treatment of midclavicular fractures. Clin Orthop Relat Res 58:29–42PubMedCrossRef Rowe CR (1968) An atlas of anatomy and treatment of midclavicular fractures. Clin Orthop Relat Res 58:29–42PubMedCrossRef
30.
go back to reference Smekal V, Oberladstaetter J, Struve P, Krappinger D (2009) Shaft fractures of the clavicle: current concepts. Arch Orthop Trauma Surg 129(6):807–815PubMedCrossRef Smekal V, Oberladstaetter J, Struve P, Krappinger D (2009) Shaft fractures of the clavicle: current concepts. Arch Orthop Trauma Surg 129(6):807–815PubMedCrossRef
31.
go back to reference Strauss EJ, Egol KA, France MA, Koval KJ, Zuckerman JD (2007) Complications of intramedullary Hagie pin fixation for acute midshaft clavicle fractures. J Shoulder Elbow Surg 16(3):280–284PubMedCrossRef Strauss EJ, Egol KA, France MA, Koval KJ, Zuckerman JD (2007) Complications of intramedullary Hagie pin fixation for acute midshaft clavicle fractures. J Shoulder Elbow Surg 16(3):280–284PubMedCrossRef
32.
go back to reference van der Meijden OA, Gaskill TR, Millett PJ (2012) Treatment of clavicle fractures: current concepts review. J Shoulder Elbow Surg 21(3):423–429PubMedCrossRef van der Meijden OA, Gaskill TR, Millett PJ (2012) Treatment of clavicle fractures: current concepts review. J Shoulder Elbow Surg 21(3):423–429PubMedCrossRef
33.
go back to reference Vander Have KL, Perdue AM, Caird MS, Farley FA (2010) Operative versus nonoperative treatment of midshaft clavicle fractures in adolescents. J Pediatr Orthop 30(4):307–312PubMedCrossRef Vander Have KL, Perdue AM, Caird MS, Farley FA (2010) Operative versus nonoperative treatment of midshaft clavicle fractures in adolescents. J Pediatr Orthop 30(4):307–312PubMedCrossRef
34.
go back to reference Wijdicks FJ, Van der Meijden OA, Millett PJ, Verleisdonk EJ, Houwert RM (2012) Systematic review of the complications of plate fixation of clavicle fractures. Arch Orthop Trauma Surg 132(5):617–625PubMedCentralPubMedCrossRef Wijdicks FJ, Van der Meijden OA, Millett PJ, Verleisdonk EJ, Houwert RM (2012) Systematic review of the complications of plate fixation of clavicle fractures. Arch Orthop Trauma Surg 132(5):617–625PubMedCentralPubMedCrossRef
35.
go back to reference Zlowodzki M, Zelle BA, Cole PA, Jeray K, McKee MD (2005) Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma 19(7):504–507PubMedCrossRef Zlowodzki M, Zelle BA, Cole PA, Jeray K, McKee MD (2005) Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the Evidence-Based Orthopaedic Trauma Working Group. J Orthop Trauma 19(7):504–507PubMedCrossRef
Metadata
Title
Stability of mid-shaft clavicle fractures after plate fixation versus intramedullary repair and after hardware removal
Authors
Sean D. Smith
Coen A. Wijdicks
Kyle S. Jansson
Robert E. Boykin
Frank Martetschlaeger
Peter-Paul de Meijer
Peter J. Millett
Tom R. Hackett
Publication date
01-02-2014
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 2/2014
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-013-2411-5

Other articles of this Issue 2/2014

Knee Surgery, Sports Traumatology, Arthroscopy 2/2014 Go to the issue