Abstract

Purpose

Previous experience has revealed excellent outcomes when using the Meniscus Arrow (Conmed Linvatec Ltd., Tampere, Finland) bioabsorable meniscal repair system for the fixation of small fracture fragments. This study describes the results of the fixation of Mason type 2 radial head fractures with these Arrows in a prospective series of 21 patients.

Methods

Between 2006 and 2010, a total of 21 patients were treated with Meniscus Arrows for the fixation of Mason type 2 fractures of the radial head during an open procedure. Twenty-one, twenty and seventeen patients were followed up at 2 and 6 post-operative weeks, 18 weeks and 24 months, respectively. Radiographs were obtained during follow-up visits, and range of motion was classified according to the Weseley classification.

Results

At 24 post-operative months, 88 % of patients showed ‘excellent’ and 12 % showed ‘good’ results in terms of extension. All patients (100 %) showed ‘excellent’ results for flexion, supination and pronation. Uneventful healing of the fracture was observed in all patients. No complications were noted.

Conclusion

This study shows promising outcomes for the use of Meniscus Arrows as fixation devices in the treatment for Mason type 2 fractures of the radial head.

Level of evidence

Prospective therapeutic study, Level IV.
Literature
1.
go back to reference Ertürer E, Seçkin F, Akman Ş, Toker S, Sari S, Öztürk İ (2010) The results of open reduction and screw or K-wire fixation for isolated type II radial head fractures. Acta Orthop Traumatol Turc 44:20–26PubMed Ertürer E, Seçkin F, Akman Ş, Toker S, Sari S, Öztürk İ (2010) The results of open reduction and screw or K-wire fixation for isolated type II radial head fractures. Acta Orthop Traumatol Turc 44:20–26PubMed
2.
go back to reference Helling HJ, Prokop H, Schmid HU et al (2006) Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study. J Should Elbow Surg 15:479–485CrossRef Helling HJ, Prokop H, Schmid HU et al (2006) Biodegradable implants versus standard metal fixation for displaced radial head fractures. A prospective, randomized, multicenter study. J Should Elbow Surg 15:479–485CrossRef
3.
go back to reference Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2006) Communited fractures of the radial head: comparison of resection and internal fixation. Surgical technique. J Bone Jt Surg Am 88:11–23CrossRef Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2006) Communited fractures of the radial head: comparison of resection and internal fixation. Surgical technique. J Bone Jt Surg Am 88:11–23CrossRef
4.
go back to reference Khalfayan EE, Culp RW, Alexander AH (1992) Mason type II radial head fractures: operative versus nonoperative treatment. J Orthop Trauma 6:283–289PubMedCrossRef Khalfayan EE, Culp RW, Alexander AH (1992) Mason type II radial head fractures: operative versus nonoperative treatment. J Orthop Trauma 6:283–289PubMedCrossRef
5.
go back to reference Koslowsky TC, Mader K, Dargel J et al (2007) Reconstruction of a Mason type-III fracture of the radial head using four different fixation techniques. J Bone Jt Surg Br 89:1545–1550CrossRef Koslowsky TC, Mader K, Dargel J et al (2007) Reconstruction of a Mason type-III fracture of the radial head using four different fixation techniques. J Bone Jt Surg Br 89:1545–1550CrossRef
6.
go back to reference Lindenhovius A, Felsch Q, Ring D, Kloen P (2009) The long-term outcome of open reduction and internal fixation of stable displaced isolated partial articular fractures of the radial head. J Trauma 67:143–146PubMedCrossRef Lindenhovius A, Felsch Q, Ring D, Kloen P (2009) The long-term outcome of open reduction and internal fixation of stable displaced isolated partial articular fractures of the radial head. J Trauma 67:143–146PubMedCrossRef
7.
go back to reference Morrey BF, Chao EY, Hui FC (1979) Biomechanical study of the elbow following excision of the radial head. J Bone Jt Surg Am 61:63–68 Morrey BF, Chao EY, Hui FC (1979) Biomechanical study of the elbow following excision of the radial head. J Bone Jt Surg Am 61:63–68
8.
go back to reference Nelis R, Wouters DB (2008) Is the use of biodegradable devices in the operative treatment of avulsion fractures of fingers, the so-called mallet finger advantageous? A feasibility study with Meniscus Arrows®. Open Orthop J 2:151–154PubMedCentralPubMedCrossRef Nelis R, Wouters DB (2008) Is the use of biodegradable devices in the operative treatment of avulsion fractures of fingers, the so-called mallet finger advantageous? A feasibility study with Meniscus Arrows®. Open Orthop J 2:151–154PubMedCentralPubMedCrossRef
9.
go back to reference Givissis PK, Symeonidis PD, Ditsios KT, Dionellis PS, Christodoulou AG (2008) Late results of absorbable pin fixation in the treatment of radial head fractures. Clin Orthop Relat Res 466:1217–1224PubMedCrossRef Givissis PK, Symeonidis PD, Ditsios KT, Dionellis PS, Christodoulou AG (2008) Late results of absorbable pin fixation in the treatment of radial head fractures. Clin Orthop Relat Res 466:1217–1224PubMedCrossRef
10.
go back to reference Ring DJ (2011) Radial head fracture: open reduction-internal fixation or prosthetic replacement. J Should Elbow Surg 20:107–112CrossRef Ring DJ (2011) Radial head fracture: open reduction-internal fixation or prosthetic replacement. J Should Elbow Surg 20:107–112CrossRef
11.
go back to reference van Riet RP, Morrey BF (2008) Documentation of associated injuries occurring with radial head fracture. Clin Orthop Relat Res 466:130–134PubMedCrossRef van Riet RP, Morrey BF (2008) Documentation of associated injuries occurring with radial head fracture. Clin Orthop Relat Res 466:130–134PubMedCrossRef
12.
go back to reference Struijs PA, Smit G, Steller EP (2007) Radial head fractures: effectiveness of conservative treatment versus surgical intervention. A systemic review. Arch Orthop Trauma Surg 127:125–130PubMedCrossRef Struijs PA, Smit G, Steller EP (2007) Radial head fractures: effectiveness of conservative treatment versus surgical intervention. A systemic review. Arch Orthop Trauma Surg 127:125–130PubMedCrossRef
13.
go back to reference Weseley MS, Barenfeld PA, Eisenstein AL (1983) Closed treatment of isolated radial head fractures. J Trauma 23:36–39PubMedCrossRef Weseley MS, Barenfeld PA, Eisenstein AL (1983) Closed treatment of isolated radial head fractures. J Trauma 23:36–39PubMedCrossRef
14.
go back to reference Wouters DB, Burgerhof JG, de Hosson JT, Bos RRM (2011) Fixation of osteochondral fragments in the human knee using Meniscus Arrows®. Knee Surg Sports Traumatol Arthrosc 19:183–188PubMedCentralPubMedCrossRef Wouters DB, Burgerhof JG, de Hosson JT, Bos RRM (2011) Fixation of osteochondral fragments in the human knee using Meniscus Arrows®. Knee Surg Sports Traumatol Arthrosc 19:183–188PubMedCentralPubMedCrossRef
15.
go back to reference Wouters DB, de Graaf JS, Hemmer PH, Burgerhof JG, Kramer WL (2011) The arthroscopic treatment of displaced tibial spine fractures in children and adolescents using Meniscus Arrows®. Knee Surg Sports Traumatol Arthrosc 19:736–739PubMedCentralPubMedCrossRef Wouters DB, de Graaf JS, Hemmer PH, Burgerhof JG, Kramer WL (2011) The arthroscopic treatment of displaced tibial spine fractures in children and adolescents using Meniscus Arrows®. Knee Surg Sports Traumatol Arthrosc 19:736–739PubMedCentralPubMedCrossRef
Metadata
Title
Successful fixation of Mason type 2 radial head fractures using Meniscus Arrows
Authors
Dirk A. Ottink
Stefan W. A. M. van Zutphen
Ron van Doorn
Diederick B. Wouters
Publication date
01-01-2014
Publisher
Springer Berlin Heidelberg
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 1/2014
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2193-1

Other articles of this Issue 1/2014

Knee Surgery, Sports Traumatology, Arthroscopy 1/2014 Go to the issue