Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 4/2013

01-04-2013 | Experimental Study

Single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) for evaluation of patients after anterior cruciate ligament reconstruction: a novel standardized algorithm combining mechanical and metabolic information

Authors: Michael T. Hirschmann, Dominic Mathis, Faik K. Afifi, Helmut Rasch, Johann Henckel, Felix Amsler, Christopher R. Wagner, Niklaus F. Friederich, Markus P. Arnold

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 4/2013

Login to get access

Abstract

Purpose

The purpose of this study was to introduce a novel standardized algorithm using SPECT/CT, which promises the potential combined assessment of the biology of the joint in particular the bone-graft-fixation complex and the 3D tunnel placement in patients after ACL reconstruction. Its clinical application and inter- and intra-observer reliability should be critically evaluated.

Methods

A novel SPECT/CT localization scheme consisting of 13 tibial, 9 femoral and 4 patellar regions on standardized axial, coronal and sagittal slices is proposed. The tracer activity on SPECT/CT was localized and recorded in 25 consecutive patients using a 3D volumetric and quantitative analysis software. The inter- and intra-observer reliability was assessed for localization and tracer activity. The tunnel position was assessed in 3D-CT using standardized frames of reference. The inter- and intra-observer reliability (OR) of the measured distances were calculated (ICC).

Results

The localization scheme for tracer uptake analysis was useful and easily applicable in all 25 knees. It showed very high inter-OR and intra-ORs for all regions (ICC > 0.80). Tibial and femoral tunnel position measurements showed strong agreement between the readings of the two observers; the ICCs for the position, angulation, length and entry point of the femoral tunnel were >0.88 (intra-OR) and >0.86 (inter-OR). The ICC for the position of the tibial tunnel (angulation, length and entry point) was >0.79 (intra-OR) and >0.74 (inter-OR).

Conclusions

The SPECT/CT algorithm presented is highly reliable and clinically feasible. Combining the 3D-mechanical information on tunnel placement and attachment areas and the 3D metabolic data will be helpful in evaluating patients with pain after ACL reconstruction.
Literature
1.
go back to reference Basdekis G, Christel P, Anne F (2009) Validation of the position of the femoral tunnels in anatomic double-bundle ACL reconstruction with 3-D CT scan. Knee Surg Sports Traumatol Arthrosc 17:1089–1094PubMedCrossRef Basdekis G, Christel P, Anne F (2009) Validation of the position of the femoral tunnels in anatomic double-bundle ACL reconstruction with 3-D CT scan. Knee Surg Sports Traumatol Arthrosc 17:1089–1094PubMedCrossRef
2.
go back to reference Bencardino JT, Beltran J, Feldman MI, Rose DJ (2009) MR imaging of complications of anterior cruciate ligament graft reconstruction. Radiographics 29:2115–2126PubMedCrossRef Bencardino JT, Beltran J, Feldman MI, Rose DJ (2009) MR imaging of complications of anterior cruciate ligament graft reconstruction. Radiographics 29:2115–2126PubMedCrossRef
3.
go back to reference Breunung N, Barwick T, Fernando R, Gnanasegaran G, Vijayanathan S, Hosahalli M, Fogelman I (2008) Additional benefit of SPECT-CT in investigating heel pain. Clin Nucl Med 33:705–706PubMedCrossRef Breunung N, Barwick T, Fernando R, Gnanasegaran G, Vijayanathan S, Hosahalli M, Fogelman I (2008) Additional benefit of SPECT-CT in investigating heel pain. Clin Nucl Med 33:705–706PubMedCrossRef
4.
go back to reference Foldager C, Jakobsen BW, Lund B, Christiansen SE, Kashi L, Mikkelsen LR, Lind M (2010) Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 18:79–84PubMedCrossRef Foldager C, Jakobsen BW, Lund B, Christiansen SE, Kashi L, Mikkelsen LR, Lind M (2010) Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 18:79–84PubMedCrossRef
5.
go back to reference Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR, Cobb JP (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Jt Surg Br 88:1513–1518CrossRef Henckel J, Richards R, Lozhkin K, Harris S, Baena FM, Barrett AR, Cobb JP (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Jt Surg Br 88:1513–1518CrossRef
6.
go back to reference Hirschmann MT, Adler T, Rasch H, Hugli RW, Friederich NF, Arnold MP (2010) Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report. Sports Med Arthrosc Rehabil Ther Technol 2:24PubMedCrossRef Hirschmann MT, Adler T, Rasch H, Hugli RW, Friederich NF, Arnold MP (2010) Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report. Sports Med Arthrosc Rehabil Ther Technol 2:24PubMedCrossRef
7.
go back to reference Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF (2011) Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop 35 675–680 Hirschmann MT, Davda K, Iranpour F, Rasch H, Friederich NF (2011) Combined single photon emission computerised tomography and conventional computerised tomography (SPECT/CT) in patellofemoral disorders: a clinical review. Int Orthop 35 675–680
8.
go back to reference Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF (2009) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc 18:341–345PubMedCrossRef Hirschmann MT, Iranpour F, Davda K, Rasch H, Hugli R, Friederich NF (2009) Combined single-photon emission computerized tomography and conventional computerized tomography (SPECT/CT): clinical value for the knee surgeons? Knee Surg Sports Traumatol Arthrosc 18:341–345PubMedCrossRef
9.
go back to reference Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944PubMedCrossRef Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944PubMedCrossRef
10.
go back to reference Hirschmann MTWR, Rasch H, Henckel J (2012) Standardized volumetric 3D analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis. BMC Med Imaging 12:5PubMedCrossRef Hirschmann MTWR, Rasch H, Henckel J (2012) Standardized volumetric 3D analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis. BMC Med Imaging 12:5PubMedCrossRef
11.
go back to reference Horger M, Eschmann SM, Pfannenberg C, Storek D, Vonthein R, Claussen CD, Bares R (2007) Added value of SPECT/CT in patients suspected of having bone infection: preliminary results. Arch Orthop Trauma Surg 127:211–221PubMedCrossRef Horger M, Eschmann SM, Pfannenberg C, Storek D, Vonthein R, Claussen CD, Bares R (2007) Added value of SPECT/CT in patients suspected of having bone infection: preliminary results. Arch Orthop Trauma Surg 127:211–221PubMedCrossRef
12.
go back to reference Inoue M, Tokuyasu S, Kuwahara S, Yasojima N, Kasahara Y, Kondo E, Onodere S, Yasuda K (2010) Tunnel location in transparent 3-dimensional CT in anatomic double-bundle anterior cruciate ligament reconstruction with the trans-tibial tunnel technique. Knee Surg Sports Traumatol Arthrosc 18:1176–1183PubMedCrossRef Inoue M, Tokuyasu S, Kuwahara S, Yasojima N, Kasahara Y, Kondo E, Onodere S, Yasuda K (2010) Tunnel location in transparent 3-dimensional CT in anatomic double-bundle anterior cruciate ligament reconstruction with the trans-tibial tunnel technique. Knee Surg Sports Traumatol Arthrosc 18:1176–1183PubMedCrossRef
13.
go back to reference Iriuchishima T, Tajima G, Ingham SJ, Shen W, Horaguchi T, Saito A, Smolinski P, Fu FH (2009) Intercondylar roof impingement pressure after anterior cruciate ligament reconstruction in a porcine model. Knee Surg Sports Traumatol Arthrosc 17:590–594PubMedCrossRef Iriuchishima T, Tajima G, Ingham SJ, Shen W, Horaguchi T, Saito A, Smolinski P, Fu FH (2009) Intercondylar roof impingement pressure after anterior cruciate ligament reconstruction in a porcine model. Knee Surg Sports Traumatol Arthrosc 17:590–594PubMedCrossRef
14.
go back to reference Kamath GV, Redfern JC, Greis PE, Burks RT (2011) Revision anterior cruciate ligament reconstruction. Am J Sports Med 39:199–217PubMedCrossRef Kamath GV, Redfern JC, Greis PE, Burks RT (2011) Revision anterior cruciate ligament reconstruction. Am J Sports Med 39:199–217PubMedCrossRef
15.
go back to reference Knupp M, Pagenstert GI, Barg A, Bolliger L, Easley ME, Hintermann B (2009) SPECT-CT compared with conventional imaging modalities for the assessment of the varus and valgus malaligned hindfoot. J Orthop Res 27:1461–1466PubMedCrossRef Knupp M, Pagenstert GI, Barg A, Bolliger L, Easley ME, Hintermann B (2009) SPECT-CT compared with conventional imaging modalities for the assessment of the varus and valgus malaligned hindfoot. J Orthop Res 27:1461–1466PubMedCrossRef
16.
go back to reference Lee A, Emmett L, Van der Wall H, Kannangara S, Mansberg R, Fogelman I (2008) SPECT/CT of femeroacetabular impingement. Clin Nucl Med 33:757–762PubMedCrossRef Lee A, Emmett L, Van der Wall H, Kannangara S, Mansberg R, Fogelman I (2008) SPECT/CT of femeroacetabular impingement. Clin Nucl Med 33:757–762PubMedCrossRef
17.
go back to reference Nomayr A, Romer W, Strobel D, Bautz W, Kuwert T (2006) Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun 27:521–528PubMedCrossRef Nomayr A, Romer W, Strobel D, Bautz W, Kuwert T (2006) Anatomical accuracy of hybrid SPECT/spiral CT in the lower spine. Nucl Med Commun 27:521–528PubMedCrossRef
18.
go back to reference Purnell ML, Larson AI, Clancy W (2008) Anterior cruciate ligament insertions on the tibia and femur and their relationships to critical bony landmarks using high-resolution volume-rendering computed tomography. Am J Sports Med 36:2083–2090PubMedCrossRef Purnell ML, Larson AI, Clancy W (2008) Anterior cruciate ligament insertions on the tibia and femur and their relationships to critical bony landmarks using high-resolution volume-rendering computed tomography. Am J Sports Med 36:2083–2090PubMedCrossRef
19.
20.
go back to reference Trojani C, Sbihi A, Djian P, Potel JF, Hulet C, Jouve F, Bussiere C, Ehkirch FP, Burdin G, Dubrana F, Beaufils P, Franceschi JP, Chassaing V, Colombet P, Neyret P (2011) Causes for failure of ACL reconstruction and influence of meniscectomies after revision. Knee Surg Sports Traumatol Arthrosc 19:196–201PubMedCrossRef Trojani C, Sbihi A, Djian P, Potel JF, Hulet C, Jouve F, Bussiere C, Ehkirch FP, Burdin G, Dubrana F, Beaufils P, Franceschi JP, Chassaing V, Colombet P, Neyret P (2011) Causes for failure of ACL reconstruction and influence of meniscectomies after revision. Knee Surg Sports Traumatol Arthrosc 19:196–201PubMedCrossRef
21.
go back to reference van Eck CF, Kropf EJ, Romanowski JR, Lesniak BP, Tranovich MJ, van Dijk CN, Fu FH (2011) ACL graft re-rupture after double-bundle reconstruction: factors that influence the intra-articular pattern of injury. Knee Surg Sports Traumatol Arthrosc 19:340–346PubMedCrossRef van Eck CF, Kropf EJ, Romanowski JR, Lesniak BP, Tranovich MJ, van Dijk CN, Fu FH (2011) ACL graft re-rupture after double-bundle reconstruction: factors that influence the intra-articular pattern of injury. Knee Surg Sports Traumatol Arthrosc 19:340–346PubMedCrossRef
22.
go back to reference Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110PubMedCrossRef Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110PubMedCrossRef
Metadata
Title
Single photon emission computerized tomography and conventional computerized tomography (SPECT/CT) for evaluation of patients after anterior cruciate ligament reconstruction: a novel standardized algorithm combining mechanical and metabolic information
Authors
Michael T. Hirschmann
Dominic Mathis
Faik K. Afifi
Helmut Rasch
Johann Henckel
Felix Amsler
Christopher R. Wagner
Niklaus F. Friederich
Markus P. Arnold
Publication date
01-04-2013
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 4/2013
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2083-6

Other articles of this Issue 4/2013

Knee Surgery, Sports Traumatology, Arthroscopy 4/2013 Go to the issue