Skip to main content
Top
Published in: Intensive Care Medicine 9/2004

01-09-2004 | Correspondence

Predicting fluid responsiveness: should we adapt the scale to measure the central venous pressure swing?

Author: Karim Bendjelid

Published in: Intensive Care Medicine | Issue 9/2004

Login to get access

Excerpt

Sir: We read with great interest the study by Barbier and colleagues [1] proposing respiratory change in inferior vena cava diameter (RCIVCD) to assess fluid responsiveness in patients ventilated with positive pressure ventilation. Their data suggest that RCIVCD is an accurate predictor of fluid responsiveness in septic patients. Moreover, baseline central venous pressure (CVP) did not accurately predict fluid responsiveness. …
Literature
1.
go back to reference Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med Mar 18 (epub ahead of print) Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, Vieillard-Baron A (2004) Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med Mar 18 (epub ahead of print)
2.
go back to reference Vieillard-Baron A, Prin S, Chergui K, Dubourg O, Jardin F (2003) Hemodynamic instability in sepsis: bedside assessment by Doppler echocardiography. Am J Respir Crit Care Med 168:1270–1276CrossRefPubMed Vieillard-Baron A, Prin S, Chergui K, Dubourg O, Jardin F (2003) Hemodynamic instability in sepsis: bedside assessment by Doppler echocardiography. Am J Respir Crit Care Med 168:1270–1276CrossRefPubMed
3.
go back to reference Jullien T, Valtier B, Hongnat JM, Dubourg O, Bourdarias JP, Jardin F (1995) Incidence of tricuspid regurgitation and vena caval backward flow in mechanically ventilated patients. A color Doppler and contrast echocardiographic study. Chest 107:488–493PubMed Jullien T, Valtier B, Hongnat JM, Dubourg O, Bourdarias JP, Jardin F (1995) Incidence of tricuspid regurgitation and vena caval backward flow in mechanically ventilated patients. A color Doppler and contrast echocardiographic study. Chest 107:488–493PubMed
4.
go back to reference Bendjelid K, Romand JA, Walder B, Suter PM, Fournier G (2002) Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated. J Am Soc Echocardiogr 15:944–949CrossRefPubMed Bendjelid K, Romand JA, Walder B, Suter PM, Fournier G (2002) Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated. J Am Soc Echocardiogr 15:944–949CrossRefPubMed
5.
go back to reference Magder S, Lagonidis D (1999) Effectiveness of albumin versus normal saline as a test of volume responsiveness in post-cardiac surgery patients. J Crit Care 14:164–171CrossRefPubMed Magder S, Lagonidis D (1999) Effectiveness of albumin versus normal saline as a test of volume responsiveness in post-cardiac surgery patients. J Crit Care 14:164–171CrossRefPubMed
Metadata
Title
Predicting fluid responsiveness: should we adapt the scale to measure the central venous pressure swing?
Author
Karim Bendjelid
Publication date
01-09-2004
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 9/2004
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-004-2326-1

Other articles of this Issue 9/2004

Intensive Care Medicine 9/2004 Go to the issue

Announcements

September 2004