Skip to main content
Top
Published in: Intensive Care Medicine 10/2003

01-10-2003 | Editorial

What's in a beat?

Author: Mervyn Singer

Published in: Intensive Care Medicine | Issue 10/2003

Login to get access

Excerpt

I remember being much taken by Ray Raper and Bill Sibbald's [3] classic exposé of the folly of equating end-diastolic pressure to end-diastolic volume without regard to ventricular compliance, or changes therein. Yet to this day I see and hear the same misunderstandings repeated time and again in both daily practice and at meetings, even by 'experts' who perhaps ought to know better! Accordingly, many hypovolaemic patients remain under-resuscitated with fluid on the basis of a high pulmonary artery wedge (or central venous) pressure and may thus be exposed to premature and/or unnecessary inotropic stimulation. Likewise, the inaccuracy of thermodilution as a measure of cardiac output with concurrent tricuspid regurgitation [4, 5] or low output states [6] is far from universally recognized. Yet even the aware may remain blissfully unaware that pulmonary hypertension, a common finding in the critically ill patient with respiratory failure, is measured echocardiographically by assessing the degree of tricuspid regurgitation [7]. I do not exclude myself from wallowing unknowingly in my own particular pits of ignorance, yet at least I recognize its high likelihood! …
Literature
1.
go back to reference Connors AF Jr, McCaffree DR, Gray BA (1983) Evaluation of right-heart catheterization in the critically ill patient without acute myocardial infarction. N Engl J Med 308:263–267 Connors AF Jr, McCaffree DR, Gray BA (1983) Evaluation of right-heart catheterization in the critically ill patient without acute myocardial infarction. N Engl J Med 308:263–267
2.
go back to reference Eisenberg PR, Jaffe AS, Schuster DP (1984) Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients. Crit Care Med 12:549–553 Eisenberg PR, Jaffe AS, Schuster DP (1984) Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patients. Crit Care Med 12:549–553
3.
go back to reference Raper R, Sibbald WJ (1986) Misled by the wedge? Chest 89:427–434 Raper R, Sibbald WJ (1986) Misled by the wedge? Chest 89:427–434
4.
go back to reference Cigarroa RG, Lange RA, Williams RH, Bedotto JB, Hillis LD (1989) Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 86:417–420 Cigarroa RG, Lange RA, Williams RH, Bedotto JB, Hillis LD (1989) Underestimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 86:417–420
5.
go back to reference Konishi T, Nakamura Y, Morii I, Himura Y, Kumada T, Kawai C (1992) Comparison of thermodilution and Fick methods for measurement of cardiac output in tricuspid regurgitation. Am J Cardiol 70:538–539 Konishi T, Nakamura Y, Morii I, Himura Y, Kumada T, Kawai C (1992) Comparison of thermodilution and Fick methods for measurement of cardiac output in tricuspid regurgitation. Am J Cardiol 70:538–539
6.
go back to reference Grondelle A van, Ditchey RV, Groves BM, Wagner WW, Reeves JT (1983) Thermodilution method overestimates low cardiac output in humans. Am J Physiol 245:H690–H692 Grondelle A van, Ditchey RV, Groves BM, Wagner WW, Reeves JT (1983) Thermodilution method overestimates low cardiac output in humans. Am J Physiol 245:H690–H692
7.
go back to reference Yock PG, Popp RL (1984) Noninvasive estimation of right ventricular systolic pressure by Doppler ultrasound in patients with tricuspid regurgitation. Circulation 70:657–662 Yock PG, Popp RL (1984) Noninvasive estimation of right ventricular systolic pressure by Doppler ultrasound in patients with tricuspid regurgitation. Circulation 70:657–662
8.
go back to reference Ganz W, Donoso R, Marcus HS, Forrester JS, Swan HJ (1971) A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 27:392–396 Ganz W, Donoso R, Marcus HS, Forrester JS, Swan HJ (1971) A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 27:392–396
9.
go back to reference Iberti TJ, Fischer EP, Leibowitz AB, Panacek EA, Silverstein JH, Albertson TE (1990) A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA 264:2928–2932 Iberti TJ, Fischer EP, Leibowitz AB, Panacek EA, Silverstein JH, Albertson TE (1990) A multicenter study of physicians' knowledge of the pulmonary artery catheter. Pulmonary Artery Catheter Study Group. JAMA 264:2928–2932
10.
go back to reference Iberti TJ, Daily EK, Leibowitz AB, Schecter CB, Fischer EP, Silverstein JH (1994) Assessment of critical care nurses' knowledge of the pulmonary artery catheter. The Pulmonary Artery Catheter Study Group. Crit Care Med 22:1674–1678 Iberti TJ, Daily EK, Leibowitz AB, Schecter CB, Fischer EP, Silverstein JH (1994) Assessment of critical care nurses' knowledge of the pulmonary artery catheter. The Pulmonary Artery Catheter Study Group. Crit Care Med 22:1674–1678
11.
go back to reference Gnaegi A, Feihl F, Perret C (1997) Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: time to act? Crit Care Med 25:213–220 Gnaegi A, Feihl F, Perret C (1997) Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: time to act? Crit Care Med 25:213–220
12.
go back to reference Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA (1996) The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 276:889–897 Connors AF Jr, Speroff T, Dawson NV, Thomas C, Harrell FE Jr, Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson WJ Jr, Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA (1996) The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 276:889–897
13.
go back to reference Chaney JC, Derdak S (2002) Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med 30:2338–2345 Chaney JC, Derdak S (2002) Minimally invasive hemodynamic monitoring for the intensivist: current and emerging technology. Crit Care Med 30:2338–2345
15.
go back to reference Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, de La Coussaye JE, Eledjam JJ (1998) Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24:347–352 Lefrant JY, Bruelle P, Aya AG, Saissi G, Dauzat M, de La Coussaye JE, Eledjam JJ (1998) Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med 24:347–352
16.
go back to reference Singer M, Clarke J, Bennett ED (1989) Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med 17:447–452 Singer M, Clarke J, Bennett ED (1989) Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med 17:447–452
17.
go back to reference Hanashiro PK, Weil MH (1972) Reliability of central venous pressure as a measure of changes in left sided intracardiac pressures. Chest 62:479–483 Hanashiro PK, Weil MH (1972) Reliability of central venous pressure as a measure of changes in left sided intracardiac pressures. Chest 62:479–483
18.
go back to reference Axler O, Tousignant C, Thompson CR, Dall'ava-Santucci J, Phang PT, Russell JA, Walley KR (1996) Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients. J Crit Care 11:109–116 Axler O, Tousignant C, Thompson CR, Dall'ava-Santucci J, Phang PT, Russell JA, Walley KR (1996) Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients. J Crit Care 11:109–116
19.
go back to reference Sherman MS, Kosinski R, Paz HL, Campbell D (1997) Measuring cardiac output in critically ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods. Cardiology 88:19–25 Sherman MS, Kosinski R, Paz HL, Campbell D (1997) Measuring cardiac output in critically ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods. Cardiology 88:19–25
20.
go back to reference Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ (2002) Lack of agreement between thermodilution and Fick cardiac output in critically ill patients. Chest 122:990–997 Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ (2002) Lack of agreement between thermodilution and Fick cardiac output in critically ill patients. Chest 122:990–997
21.
go back to reference Schmid ER, Schmidlin D, Tornic M, Seifert B (1999) Continuous thermodilution cardiac output: clinical validation against a reference technique of known accuracy. Intensive Care Med 25:166–712 Schmid ER, Schmidlin D, Tornic M, Seifert B (1999) Continuous thermodilution cardiac output: clinical validation against a reference technique of known accuracy. Intensive Care Med 25:166–712
22.
go back to reference Hensel M, Kox WJ (1999) Increased intrapulmonary oxygen consumption in mechanically ventilated patients with pneumonia. Am J Respir Crit Care Med 160:137–143 Hensel M, Kox WJ (1999) Increased intrapulmonary oxygen consumption in mechanically ventilated patients with pneumonia. Am J Respir Crit Care Med 160:137–143
23.
go back to reference Stock MC, Ryan ME (1996) Oxygen consumption calculated from the Fick equation has limited utility. Crit Care Med 24:86–90 Stock MC, Ryan ME (1996) Oxygen consumption calculated from the Fick equation has limited utility. Crit Care Med 24:86–90
24.
go back to reference Klotz K-F, Klingsiek S, Singer M, Wenk H, Eleftheriadis E, Kuppe H, Schmucker P (1995) Continuous measurement of cardiac output during aortic cross-clamping by the oesophageal Doppler monitor ODM 1 Br J Anaesth 74:655–660 Klotz K-F, Klingsiek S, Singer M, Wenk H, Eleftheriadis E, Kuppe H, Schmucker P (1995) Continuous measurement of cardiac output during aortic cross-clamping by the oesophageal Doppler monitor ODM 1 Br J Anaesth 74:655–660
25.
go back to reference Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thebert D, Brunet F, Dhainaut JF (1998) Noninvasive cardiac output monitoring by aortic blood flow determinations: evaluation of the Sometec Dynemo-3000 system. Crit Care Med 26:2066–2072 Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thebert D, Brunet F, Dhainaut JF (1998) Noninvasive cardiac output monitoring by aortic blood flow determinations: evaluation of the Sometec Dynemo-3000 system. Crit Care Med 26:2066–2072
26.
go back to reference Mythen MG, Webb AR (1995) Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg 130:423–429 Mythen MG, Webb AR (1995) Perioperative plasma volume expansion reduces the incidence of gut mucosal hypoperfusion during cardiac surgery. Arch Surg 130:423–429
27.
go back to reference Sinclair S, James S, Singer M (1997) Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 315:909–912 Sinclair S, James S, Singer M (1997) Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BMJ 315:909–912
28.
go back to reference Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P (2002) Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 88:65–71 Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P (2002) Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth 88:65–71
29.
go back to reference Gan TJ, Soppitt A, Maroof M, El-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS (2002) Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 97:820–826 Gan TJ, Soppitt A, Maroof M, El-Moalem H, Robertson KM, Moretti E, Dwane P, Glass PS (2002) Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 97:820–826
Metadata
Title
What's in a beat?
Author
Mervyn Singer
Publication date
01-10-2003
Publisher
Springer-Verlag
Published in
Intensive Care Medicine / Issue 10/2003
Print ISSN: 0342-4642
Electronic ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-003-1766-3

Other articles of this Issue 10/2003

Intensive Care Medicine 10/2003 Go to the issue