Abstract

Objective

Investigating the anatomical characteristics of supra-acetabular screw corridor as well as comparing the biomechanical stability between semi- and full-length screw external fixations for Tile C1 pelvic fractures.

Methods

50 male and 50 female uninjured pelvic CT data were converted into three-dimensional models and the supra-acetabular corridors were reconstructed by the Mimics software. The horizontal slice was redefined passing through the bilateral anterior inferior iliac spine and bilateral posterior superior iliac spine at the same time. On every horizontal slices, a 5 mm diameter virtual screw was placed along with the unilateral anterior narrowing to posterior narrowing of the supra-acetabular corridor, and the relevant parameters of the semi- and full-length screw fixations were measured from inferior to superior at an interval height of 2.5 mm until the width of the corridor was less than 5 mm. Thus, the insertion position was located, as well as the inclination angle ranges were measured. The same procedure was done on a bilateral supra-acetabular corridor for each patient. Last, a Tile C1 pelvic finite element model was simulated and fixed with either semi- or a full-length anterior supra-acetabular external fixator. A 500 N loading was tested on the model with three directions (cranial–caudal, anterior–posterior and lateral–medial) and the stiffness was determined by the max displacements.

Results

The insertion points of supra-acetabular screw for 66% (66/100) of men and 78% (78/100) of women were located at the outer lower part of the anterior inferior iliac spine (AIIS) (p < 0.001). The medial inclination angles of the screw were 29.50 ± 4.05° for men and 28.00 ± 3.78° for women (p = 0.007). The cranial inclination angles of the screw were 29.40 ± 5.38° for men and 28.57 ± 6.01° for women (p = 0.306). The safe inclination angle ranges of the semi-length screw were 3°–6° bigger than the full-length screw. For semi-length corridor, the widths were 14.07 ± 2.39 mm for men and 11.29 ± 1.81 mm for women (p < 0.001) and the depths were 71.77 ± 5.96 mm for men and 69.26 ± 5.21 mm for women (p < 0.001). For full-length corridor, the widths were 10.61 ± 2.10 mm for men and 8.44 ± 2.03 mm for women (p < 0.001) and the depths were 133.37 ± 7.60 mm for men and 129.01 ± 8.12 mm for women (p < 0.001). In the finite element analysis, the max displacements of the pelvis under three loading modes (cranial–caudal, anterior–posterior and lateral–medial) for semi-length fixation were 0.772 mm, 0.409 mm and 0.331 mm and for full-length fixation were 0.727 mm, 0.385 mm and 0.262 mm.

Conclusion

The outer lower part of AIIS is recommended as an insertion point of the supra-acetabular screw with about 30° medial and cranial inclination angles, and the semi-length screw is safer for placing and has satisfactory biomechanical stability by compared with a full-length screw.
Literature
1.
go back to reference Tscherne H, et al. Crush injuries of the pelvis. Eur J Surg. 2000;166(4):276–82.CrossRef Tscherne H, et al. Crush injuries of the pelvis. Eur J Surg. 2000;166(4):276–82.CrossRef
2.
go back to reference Haidukewych GJ, Kumar S, Prpa B. Placement of half-pins for supra-acetabular external fixation: an anatomic study. Clin Orthop Relat Res. 2003;411(6):269–73.CrossRef Haidukewych GJ, Kumar S, Prpa B. Placement of half-pins for supra-acetabular external fixation: an anatomic study. Clin Orthop Relat Res. 2003;411(6):269–73.CrossRef
3.
go back to reference Calafi LA, Routt ML. Anterior pelvic external fixation: is there an optimal placement for the supra-acetabular pin? Am J Orthop (Belle Mead NJ). 2013;43(12):E125–E127127. Calafi LA, Routt ML. Anterior pelvic external fixation: is there an optimal placement for the supra-acetabular pin? Am J Orthop (Belle Mead NJ). 2013;43(12):E125–E127127.
4.
go back to reference Vigdorchik JM, et al. Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone. Int Orthop. 2013;37(7):1341–6.CrossRef Vigdorchik JM, et al. Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone. Int Orthop. 2013;37(7):1341–6.CrossRef
5.
go back to reference Gardner MJ, et al. Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone. J Orthop Trauma. 2007;21(7):435–41.CrossRef Gardner MJ, et al. Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone. J Orthop Trauma. 2007;21(7):435–41.CrossRef
6.
go back to reference Snell R. Clinical anatomy. 7th ed. Baltinore: Lippincott Williams & Wilkins; 2004. Snell R. Clinical anatomy. 7th ed. Baltinore: Lippincott Williams & Wilkins; 2004.
7.
go back to reference Schildhauer TA, et al. Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations. J Spinal Disord Tech. 2002;15(3):199–205.CrossRef Schildhauer TA, et al. Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations. J Spinal Disord Tech. 2002;15(3):199–205.CrossRef
8.
go back to reference Berry JL, Stahurski T, Asher MA. Morphometry of the supra sciatic notch intrailiac implant anchor passage. Spine (Phila Pa 1976). 2001;26(7):E143–E148148.CrossRef Berry JL, Stahurski T, Asher MA. Morphometry of the supra sciatic notch intrailiac implant anchor passage. Spine (Phila Pa 1976). 2001;26(7):E143–E148148.CrossRef
9.
go back to reference Bodzay T, Floris I, Varadi K. Comparison of stability in the operative treatment of pelvic injuries in a finite element model. Arch Orthop Trauma Surg. 2011;131(10):1427–33.CrossRef Bodzay T, Floris I, Varadi K. Comparison of stability in the operative treatment of pelvic injuries in a finite element model. Arch Orthop Trauma Surg. 2011;131(10):1427–33.CrossRef
10.
go back to reference Gardner MJ, Nork SE. Stabilization of unstable pelvic fractures with supraacetabular compression external fixation. J Orthop Trauma. 2007;21(4):269–73.CrossRef Gardner MJ, Nork SE. Stabilization of unstable pelvic fractures with supraacetabular compression external fixation. J Orthop Trauma. 2007;21(4):269–73.CrossRef
11.
go back to reference Wang F, et al. Supra-acetabular external fixation for pelvic fractures: a digital anatomical study. Clin Anat. 2012;25(4):503–8.CrossRef Wang F, et al. Supra-acetabular external fixation for pelvic fractures: a digital anatomical study. Clin Anat. 2012;25(4):503–8.CrossRef
12.
go back to reference Mears DC, Fu FH. Modern concepts of external skeletal fixation of the pelvis. Clin Orthop Relat Res. 1980;151:65–72. Mears DC, Fu FH. Modern concepts of external skeletal fixation of the pelvis. Clin Orthop Relat Res. 1980;151:65–72.
13.
go back to reference Bellabarba C, et al. Midline sagittal sacral fractures in anterior-posterior compression pelvic ring injuries. J Orthop Trauma. 2003;17(1):32–7.CrossRef Bellabarba C, et al. Midline sagittal sacral fractures in anterior-posterior compression pelvic ring injuries. J Orthop Trauma. 2003;17(1):32–7.CrossRef
14.
go back to reference Pennal CF, Sutherland GO. Fractures of the pelvis (motion picture). Park Ridge: American Academy of Orthopadeic Surgeons Film Library; 1961. Pennal CF, Sutherland GO. Fractures of the pelvis (motion picture). Park Ridge: American Academy of Orthopadeic Surgeons Film Library; 1961.
Metadata
Title
Anterior supra-acetabular external fixation for tile C1 pelvic fractures: a digital anatomical study and a finite element analysis
Authors
Tan Shan
Liang Anlin
Yang Mingming
Yang Haitao
Zhang Anwei
Gao Shichang
Publication date
01-12-2021
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Trauma and Emergency Surgery / Issue 6/2021
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-020-01517-8

Other articles of this Issue 6/2021

European Journal of Trauma and Emergency Surgery 6/2021 Go to the issue