Skip to main content
Top
Published in: European Journal of Trauma and Emergency Surgery 1/2013

01-02-2013 | Review Article

Whole body imaging in the diagnosis of blunt trauma, ionizing radiation hazards and residual risk

Published in: European Journal of Trauma and Emergency Surgery | Issue 1/2013

Login to get access

Abstract

Ever since the introduction of radiographic imaging, its utility in identifying injuries has been well documented and was incorporated in the workup of injured patients during advanced trauma life support algorithms [American College of Surgeons, 8th ed. Chicago, 2008]. More recently, computerized tomography (CT) has been shown to be more sensitive than radiography in the diagnosis of injury. Due to the increased use of CT scanning, concerns were raised regarding the associated exposure to ionizing radiation [N Engl J Med 357:2277–2284, 2007]. During the last several years, a significant amount of research has been published on this topic, most of it being incorporated in the BEIR VII Phase 2 report, published by the National Research Council of the National Academies [National Academy of Sciences, Washington DC, 2006]. The current review will analyze the scientific basis for the concerns over the ionizing radiation associated with the use of CT scanning and will examine the accuracy of the typical advanced trauma life support work-up for diagnosis of injuries.
Literature
1.
go back to reference Korley FK, Pham JC, Kirsch TD. Use of advanced radiology during visits to US emergency departments for injury-related conditions, 1998–2007. JAMA. 2010;304:1465–71.PubMedCrossRef Korley FK, Pham JC, Kirsch TD. Use of advanced radiology during visits to US emergency departments for injury-related conditions, 1998–2007. JAMA. 2010;304:1465–71.PubMedCrossRef
2.
go back to reference Brenner DJ, Hall EJ. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–84.PubMedCrossRef Brenner DJ, Hall EJ. Computed tomography—an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–84.PubMedCrossRef
3.
go back to reference National Academy of Sciences. Health risks from exposure to low levels of ionizing radiation: BEIR VII-Phase 2. Washington DC: National Academies Press; 2006. National Academy of Sciences. Health risks from exposure to low levels of ionizing radiation: BEIR VII-Phase 2. Washington DC: National Academies Press; 2006.
4.
go back to reference Zankl M, Eckerman KF, Bolch WE. Voxel-based models representing the male and female ICRP reference adult—the skeleton. Radiat Prot Dosimetry. 2007;127:174–86.PubMedCrossRef Zankl M, Eckerman KF, Bolch WE. Voxel-based models representing the male and female ICRP reference adult—the skeleton. Radiat Prot Dosimetry. 2007;127:174–86.PubMedCrossRef
5.
go back to reference Brenner DJ, Doll R, Goodhead DT, Hall EJ, Land CE, Little JB, Lubin JH, Preston DL, Preston RJ, Puskin JS, Ron E, Sachs RK, Samet JM, Setlow RB, Zaider M. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci USA. 2003;100:13761–6.PubMedCrossRef Brenner DJ, Doll R, Goodhead DT, Hall EJ, Land CE, Little JB, Lubin JH, Preston DL, Preston RJ, Puskin JS, Ron E, Sachs RK, Samet JM, Setlow RB, Zaider M. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci USA. 2003;100:13761–6.PubMedCrossRef
6.
go back to reference National Academcy of Sciences. Health effects of radiation: findings of the radiation effects research foundation. Washington DC: National Academies Press; 2006. National Academcy of Sciences. Health effects of radiation: findings of the radiation effects research foundation. Washington DC: National Academies Press; 2006.
7.
go back to reference Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology. 2008;248:254–63.PubMedCrossRef Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology. 2008;248:254–63.PubMedCrossRef
8.
go back to reference Parry RA, Glaze SA, Archer BR. The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology. Radiographics. 1999;19:1289–302.PubMed Parry RA, Glaze SA, Archer BR. The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology. Radiographics. 1999;19:1289–302.PubMed
9.
go back to reference Preston DL, Ron E, Tokuoka S, Funamoto S, Nishi N, Soda M, Mabuchi K, Kodama K. Solid cancer incidence in atomic bomb survivors: 1958–1998. Radiat Res. 2007;168:1–64.PubMedCrossRef Preston DL, Ron E, Tokuoka S, Funamoto S, Nishi N, Soda M, Mabuchi K, Kodama K. Solid cancer incidence in atomic bomb survivors: 1958–1998. Radiat Res. 2007;168:1–64.PubMedCrossRef
10.
go back to reference Jacob P, Meckbach R, Sokolnikov M, Khokhryakov VV, Vasilenko E. Lung cancer risk of Mayak workers: modelling of carcinogenesis and bystander effect. Radiat Environ Biophys. 2007;46:383–94.PubMedCrossRef Jacob P, Meckbach R, Sokolnikov M, Khokhryakov VV, Vasilenko E. Lung cancer risk of Mayak workers: modelling of carcinogenesis and bystander effect. Radiat Environ Biophys. 2007;46:383–94.PubMedCrossRef
11.
go back to reference Krestinina LY, Davis F, Ostroumova E, Epifanova S, Degteva M, Preston D, Akleyev A. Solid cancer incidence and low-dose-rate radiation exposures in the Techa River cohort: 1956–2002. Int J Epidemiol. 2007;36:1038–46.PubMedCrossRef Krestinina LY, Davis F, Ostroumova E, Epifanova S, Degteva M, Preston D, Akleyev A. Solid cancer incidence and low-dose-rate radiation exposures in the Techa River cohort: 1956–2002. Int J Epidemiol. 2007;36:1038–46.PubMedCrossRef
12.
go back to reference Storer JB, Mitchell TJ, Fry RJ. Extrapolation of the relative risk of radiogenic neoplasms across mouse strains and to man. Radiat Res. 1988;114:331–53.PubMedCrossRef Storer JB, Mitchell TJ, Fry RJ. Extrapolation of the relative risk of radiogenic neoplasms across mouse strains and to man. Radiat Res. 1988;114:331–53.PubMedCrossRef
13.
go back to reference Carnes BA, Grahn D, Thomson JF. Dose-response modeling of life shortening in a retrospective analysis of the combined data from the JANUS program at Argonne National Laboratory. Radiat Res. 1989;119:39–56.PubMedCrossRef Carnes BA, Grahn D, Thomson JF. Dose-response modeling of life shortening in a retrospective analysis of the combined data from the JANUS program at Argonne National Laboratory. Radiat Res. 1989;119:39–56.PubMedCrossRef
14.
go back to reference Covelli V, Di Majo V, Coppola M, Rebessi S. The dose-response relationships for myeloid leukemia and malignant lymphoma in BC3F1 mice. Radiat Res. 1989;119:553–61.PubMedCrossRef Covelli V, Di Majo V, Coppola M, Rebessi S. The dose-response relationships for myeloid leukemia and malignant lymphoma in BC3F1 mice. Radiat Res. 1989;119:553–61.PubMedCrossRef
15.
go back to reference U.S. Government Accountability Office (USGAO). Radiation standards: scientific basis inconclusive and EPA and NRA disagreement continues. In: Office USGA. editor. Washington DC: USGAO; 2000. U.S. Government Accountability Office (USGAO). Radiation standards: scientific basis inconclusive and EPA and NRA disagreement continues. In: Office USGA. editor. Washington DC: USGAO; 2000.
16.
go back to reference Leonard BE. Common sense about the linear no-threshold controversy-give the general public a break. Radiat Res. 2008;169:245–6. [author reply 246–247].PubMedCrossRef Leonard BE. Common sense about the linear no-threshold controversy-give the general public a break. Radiat Res. 2008;169:245–6. [author reply 246–247].PubMedCrossRef
17.
go back to reference Breckow J. Linear-no-threshold is a radiation-protection standard rather than a mechanistic effect model. Radiat Environ Biophys. 2006;44:257–60.PubMedCrossRef Breckow J. Linear-no-threshold is a radiation-protection standard rather than a mechanistic effect model. Radiat Environ Biophys. 2006;44:257–60.PubMedCrossRef
18.
go back to reference Tubiana M, Aurengo A, Averbeck D, Masse R. The debate on the use of linear no threshold for assessing the effects of low doses. J Radiol Prot. 2006;26:317–24.PubMedCrossRef Tubiana M, Aurengo A, Averbeck D, Masse R. The debate on the use of linear no threshold for assessing the effects of low doses. J Radiol Prot. 2006;26:317–24.PubMedCrossRef
19.
go back to reference Tubiana M, Feinendegen LE, Yang C, Kaminski JM. The linear no-threshold relationship is inconsistent with radiation biologic and experimental data. Radiology. 2009;251:13–22.PubMedCrossRef Tubiana M, Feinendegen LE, Yang C, Kaminski JM. The linear no-threshold relationship is inconsistent with radiation biologic and experimental data. Radiology. 2009;251:13–22.PubMedCrossRef
20.
go back to reference Brenner DJ, Elliston CD. Estimated radiation risks potentially associated with full-body CT screening. Radiology. 2004;232:735–8.PubMedCrossRef Brenner DJ, Elliston CD. Estimated radiation risks potentially associated with full-body CT screening. Radiology. 2004;232:735–8.PubMedCrossRef
21.
go back to reference Laack TA, Thompson KM, Kofler JM, Bellolio MF, Sawyer MD, Laack NN. Comparison of trauma mortality and estimated cancer mortality from computed tomography during initial evaluation of intermediate-risk trauma patients. J Trauma. 2011;70:1362–5.PubMedCrossRef Laack TA, Thompson KM, Kofler JM, Bellolio MF, Sawyer MD, Laack NN. Comparison of trauma mortality and estimated cancer mortality from computed tomography during initial evaluation of intermediate-risk trauma patients. J Trauma. 2011;70:1362–5.PubMedCrossRef
22.
go back to reference Moores BM, Regulla D. A review of the scientific basis for radiation protection of the patient. Radiat Prot Dosimetry. 2011;147:22–9.PubMedCrossRef Moores BM, Regulla D. A review of the scientific basis for radiation protection of the patient. Radiat Prot Dosimetry. 2011;147:22–9.PubMedCrossRef
23.
go back to reference Azzam EI, de Toledo SM, Raaphorst GP, Mitchel RE. Low-dose ionizing radiation decreases the frequency of neoplastic transformation to a level below the spontaneous rate in C3H 10T1/2 cells. Radiat Res. 1996;146:369–73.PubMedCrossRef Azzam EI, de Toledo SM, Raaphorst GP, Mitchel RE. Low-dose ionizing radiation decreases the frequency of neoplastic transformation to a level below the spontaneous rate in C3H 10T1/2 cells. Radiat Res. 1996;146:369–73.PubMedCrossRef
24.
25.
go back to reference Wei LX, Zha YR, Tao ZF, He WH, Chen DQ, Yuan YL. Epidemiological investigation of radiological effects in high background radiation areas of Yangjiang. China. J Radiat Res (Tokyo). 1990;31:119–36.CrossRef Wei LX, Zha YR, Tao ZF, He WH, Chen DQ, Yuan YL. Epidemiological investigation of radiological effects in high background radiation areas of Yangjiang. China. J Radiat Res (Tokyo). 1990;31:119–36.CrossRef
26.
go back to reference Frigerio NA, Stowe RS. Carcinogenic and genetic hazard from background radiation; biological and environmental effects of low-level radiation. Vol II. Vienna: IAEA; 1976. Frigerio NA, Stowe RS. Carcinogenic and genetic hazard from background radiation; biological and environmental effects of low-level radiation. Vol II. Vienna: IAEA; 1976.
27.
go back to reference Abbat JD, Hamilton TR, Weeks JL. Epidemiological studiesin three corporations covering the Canadian nuclear fuel cycle; biological effects of low level radiation. Vienna: IAEA; 1983. pp 351. Abbat JD, Hamilton TR, Weeks JL. Epidemiological studiesin three corporations covering the Canadian nuclear fuel cycle; biological effects of low level radiation. Vienna: IAEA; 1983. pp 351.
28.
go back to reference Kendal GM, Muirhead CR, Macgibbon BH, Oagan JA. First analysis of the national registry for radiation workers: occupational exposure to ionizing radiation and mortality. NRPB, RPB-R251. Chilton, Didcot, UK: NRPB; 1992. Kendal GM, Muirhead CR, Macgibbon BH, Oagan JA. First analysis of the national registry for radiation workers: occupational exposure to ionizing radiation and mortality. NRPB, RPB-R251. Chilton, Didcot, UK: NRPB; 1992.
29.
go back to reference Sponsler S, Cameron JR. Nuclear shipyard worker study (1980–1988): a large cohort exposed to low-dose-rate gamma radiation. Int J Low Radiat. 2005;1:463–78.CrossRef Sponsler S, Cameron JR. Nuclear shipyard worker study (1980–1988): a large cohort exposed to low-dose-rate gamma radiation. Int J Low Radiat. 2005;1:463–78.CrossRef
30.
31.
go back to reference Salim A, Sangthong B, Martin M, Brown C, Plurad D, Demetriades D. Whole body imaging in blunt multisystem trauma patients without obvious signs of injury: results of a prospective study. Arch Surg. 2006;141:468–73. (discussion 473–475).PubMedCrossRef Salim A, Sangthong B, Martin M, Brown C, Plurad D, Demetriades D. Whole body imaging in blunt multisystem trauma patients without obvious signs of injury: results of a prospective study. Arch Surg. 2006;141:468–73. (discussion 473–475).PubMedCrossRef
32.
go back to reference Compoginis JM, Akopian G. CT imaging in motorcycle collision victims: routine or selective? Am Surg. 2009;75:892–6.PubMed Compoginis JM, Akopian G. CT imaging in motorcycle collision victims: routine or selective? Am Surg. 2009;75:892–6.PubMed
33.
go back to reference Duane TM, Mayglothling J, Wilson SP, Wolfe LG, Aboutanos MB, Whelan JF, Malhotra AK, Ivatury RR. National Emergency X-Radiography Utilization Study criteria is inadequate to rule out fracture after significant blunt trauma compared with computed tomography. J Trauma. 2011;70:829–31.PubMedCrossRef Duane TM, Mayglothling J, Wilson SP, Wolfe LG, Aboutanos MB, Whelan JF, Malhotra AK, Ivatury RR. National Emergency X-Radiography Utilization Study criteria is inadequate to rule out fracture after significant blunt trauma compared with computed tomography. J Trauma. 2011;70:829–31.PubMedCrossRef
34.
go back to reference Parmley LF, Mattingly TW, Manion WC, Jahnke EJ Jr. Nonpenetrating traumatic injury of the aorta. Circulation. 1958;17:1086–101.PubMedCrossRef Parmley LF, Mattingly TW, Manion WC, Jahnke EJ Jr. Nonpenetrating traumatic injury of the aorta. Circulation. 1958;17:1086–101.PubMedCrossRef
35.
go back to reference Ferrera PC, Verdile VP, Bartfield JM, Snyder HS, Salluzzo RF. Injuries distracting from intraabdominal injuries after blunt trauma. Am J Emerg Med. 1998;16:145–9.PubMedCrossRef Ferrera PC, Verdile VP, Bartfield JM, Snyder HS, Salluzzo RF. Injuries distracting from intraabdominal injuries after blunt trauma. Am J Emerg Med. 1998;16:145–9.PubMedCrossRef
36.
go back to reference Deunk J, Brink M, Dekker HM, Kool DR, van Kuijk C, Blickman JG, van Vugt AB, Edwards MJ. Routine versus selective computed tomography of the abdomen, pelvis, and lumbar spine in blunt trauma: a prospective evaluation. J Trauma. 2009;66:1108–17.PubMedCrossRef Deunk J, Brink M, Dekker HM, Kool DR, van Kuijk C, Blickman JG, van Vugt AB, Edwards MJ. Routine versus selective computed tomography of the abdomen, pelvis, and lumbar spine in blunt trauma: a prospective evaluation. J Trauma. 2009;66:1108–17.PubMedCrossRef
37.
go back to reference Halley MK, Silva PD, Foley J, Rodarte A. Loss of consciousness: when to perform computed tomography? Pediatr Crit Care Med. 2004;5:230–3.PubMedCrossRef Halley MK, Silva PD, Foley J, Rodarte A. Loss of consciousness: when to perform computed tomography? Pediatr Crit Care Med. 2004;5:230–3.PubMedCrossRef
38.
go back to reference Bivins BA, Zona JZ, Belin RP. Diagnostic peritoneal lavage in pediatric trauma. J Trauma. 1976;16:739–42.PubMedCrossRef Bivins BA, Zona JZ, Belin RP. Diagnostic peritoneal lavage in pediatric trauma. J Trauma. 1976;16:739–42.PubMedCrossRef
40.
go back to reference American College of Surgeons. ATLS: advanced trauma life support for doctors (student course manual). 8th ed. Chicago: American College of Surgeons; 2008. American College of Surgeons. ATLS: advanced trauma life support for doctors (student course manual). 8th ed. Chicago: American College of Surgeons; 2008.
41.
go back to reference Diaz JJ Jr, Gillman C, Morris JA Jr, May AK, Carrillo YM, Guy J. Are five-view plain films of the cervical spine unreliable? A prospective evaluation in blunt trauma patients with altered mental status. J Trauma. 2003;55:658–63. (discussion 663–664).PubMedCrossRef Diaz JJ Jr, Gillman C, Morris JA Jr, May AK, Carrillo YM, Guy J. Are five-view plain films of the cervical spine unreliable? A prospective evaluation in blunt trauma patients with altered mental status. J Trauma. 2003;55:658–63. (discussion 663–664).PubMedCrossRef
42.
go back to reference Duane TM, Dechert T, Brown H, Wolfe LG, Malhotra AK, Aboutanos MB, Ivatury RR. Is the lateral cervical spine plain film obsolete? J Surg Res. 2008;147:267–9.PubMedCrossRef Duane TM, Dechert T, Brown H, Wolfe LG, Malhotra AK, Aboutanos MB, Ivatury RR. Is the lateral cervical spine plain film obsolete? J Surg Res. 2008;147:267–9.PubMedCrossRef
43.
go back to reference Demetriades D, Gomez H, Velmahos GC, Asensio JA, Murray J, Cornwell EE 3rd, Alo K, Berne TV. Routine helical computed tomographic evaluation of the mediastinum in high-risk blunt trauma patients. Arch Surg. 1998;133:1084–8.PubMedCrossRef Demetriades D, Gomez H, Velmahos GC, Asensio JA, Murray J, Cornwell EE 3rd, Alo K, Berne TV. Routine helical computed tomographic evaluation of the mediastinum in high-risk blunt trauma patients. Arch Surg. 1998;133:1084–8.PubMedCrossRef
44.
go back to reference Exadaktylos AK, Sclabas G, Schmid SW, Schaller B, Zimmermann H. Do we really need routine computed tomographic scanning in the primary evaluation of blunt chest trauma in patients with “normal” chest radiograph? J Trauma. 2001;51:1173–6.PubMedCrossRef Exadaktylos AK, Sclabas G, Schmid SW, Schaller B, Zimmermann H. Do we really need routine computed tomographic scanning in the primary evaluation of blunt chest trauma in patients with “normal” chest radiograph? J Trauma. 2001;51:1173–6.PubMedCrossRef
45.
go back to reference Guillamondegui OD, Pryor JP, Gracias VH, Gupta R, Reilly PM, Schwab CW. Pelvic radiography in blunt trauma resuscitation: a diminishing role. J Trauma. 2002;53:1043–7.PubMedCrossRef Guillamondegui OD, Pryor JP, Gracias VH, Gupta R, Reilly PM, Schwab CW. Pelvic radiography in blunt trauma resuscitation: a diminishing role. J Trauma. 2002;53:1043–7.PubMedCrossRef
46.
go back to reference Asimos AW, Gibbs MA, Marx JA, Jacobs DG, Erwin RJ, Norton HJ, Thomason M. Value of point-of-care blood testing in emergent trauma management. J Trauma. 2000;48:1101–8.PubMedCrossRef Asimos AW, Gibbs MA, Marx JA, Jacobs DG, Erwin RJ, Norton HJ, Thomason M. Value of point-of-care blood testing in emergent trauma management. J Trauma. 2000;48:1101–8.PubMedCrossRef
47.
go back to reference Madsen T, Dawson M, Bledsoe J, Bossart P. Serial hematocrit testing does not identify major injuries in trauma patients in an observation unit. Am J Emerg Med. 2010;28:472–6.PubMedCrossRef Madsen T, Dawson M, Bledsoe J, Bossart P. Serial hematocrit testing does not identify major injuries in trauma patients in an observation unit. Am J Emerg Med. 2010;28:472–6.PubMedCrossRef
48.
go back to reference Opreanu RC, Arrangoiz R, Stevens P, Morrison CA, Mosher BD, Kepros JP. Hematocrit, systolic blood pressure and heart rate are not accurate predictors for surgery to control hemorrhage in injured patients. Am Surg. 2010;76:296–301.PubMed Opreanu RC, Arrangoiz R, Stevens P, Morrison CA, Mosher BD, Kepros JP. Hematocrit, systolic blood pressure and heart rate are not accurate predictors for surgery to control hemorrhage in injured patients. Am Surg. 2010;76:296–301.PubMed
49.
go back to reference Natarajan B, Gupta PK, Cemaj S, Sorensen M, Hatzoudis GI, Forse RA. FAST scan: is it worth doing in hemodynamically stable blunt trauma patients? Surgery. 2010;148:695–700. (discussion 700–701).PubMedCrossRef Natarajan B, Gupta PK, Cemaj S, Sorensen M, Hatzoudis GI, Forse RA. FAST scan: is it worth doing in hemodynamically stable blunt trauma patients? Surgery. 2010;148:695–700. (discussion 700–701).PubMedCrossRef
50.
go back to reference Becker A, Lin G, McKenney MG, Marttos A, Schulman CI. Is the FAST exam reliable in severely injured patients? Injury. 2010;41:479–83.PubMedCrossRef Becker A, Lin G, McKenney MG, Marttos A, Schulman CI. Is the FAST exam reliable in severely injured patients? Injury. 2010;41:479–83.PubMedCrossRef
52.
go back to reference Nichols JS, Elger C, Hemminger L, Prall JA, Shaver K, Brennan R, Whitaker JB. Magnetic resonance imaging: utilization in the management of central nervous system trauma. J Trauma. 1997;42:520–3. (discussion 523–24).PubMedCrossRef Nichols JS, Elger C, Hemminger L, Prall JA, Shaver K, Brennan R, Whitaker JB. Magnetic resonance imaging: utilization in the management of central nervous system trauma. J Trauma. 1997;42:520–3. (discussion 523–24).PubMedCrossRef
53.
go back to reference Stephan PJ, McCarley MC, O’Keefe GE, Minei JP. 23-Hour observation solely for identification of missed injuries after trauma: is it justified? J Trauma. 2002;53:895–900.PubMedCrossRef Stephan PJ, McCarley MC, O’Keefe GE, Minei JP. 23-Hour observation solely for identification of missed injuries after trauma: is it justified? J Trauma. 2002;53:895–900.PubMedCrossRef
54.
go back to reference Giannakopoulos GF, Saltzherr TP, Beenen LF, Reitsma JB, Bloemers FW, Goslings JC, Bakker FC. Missed injuries during the initial assessment in a cohort of 1124 level-1 trauma patients. Injury; 2011. [Epub ahead of print]. Giannakopoulos GF, Saltzherr TP, Beenen LF, Reitsma JB, Bloemers FW, Goslings JC, Bakker FC. Missed injuries during the initial assessment in a cohort of 1124 level-1 trauma patients. Injury; 2011. [Epub ahead of print].
55.
go back to reference Biffl WL, Harrington DT, Cioffi WG. Implementation of a tertiary trauma survey decreases missed injuries. J Trauma. 2003;54:38–43. (discussion 43–44).PubMedCrossRef Biffl WL, Harrington DT, Cioffi WG. Implementation of a tertiary trauma survey decreases missed injuries. J Trauma. 2003;54:38–43. (discussion 43–44).PubMedCrossRef
56.
go back to reference Poletti PA, Mirvis SE, Shanmuganathan K, Takada T, Killeen KL, Perlmutter D, Hahn J, Mermillod B. Blunt abdominal trauma patients: can organ injury be excluded without performing computed tomography? J Trauma. 2004;57:1072–81.PubMedCrossRef Poletti PA, Mirvis SE, Shanmuganathan K, Takada T, Killeen KL, Perlmutter D, Hahn J, Mermillod B. Blunt abdominal trauma patients: can organ injury be excluded without performing computed tomography? J Trauma. 2004;57:1072–81.PubMedCrossRef
57.
go back to reference Teixeira PG, Inaba K, Salim A, Rhee P, Brown C, Browder T, DuBose J, Nomoto S, Demetriades D. Preventable morbidity at a mature trauma center. Arch Surg. 2009;144:536–41. (discussion 541–542).PubMedCrossRef Teixeira PG, Inaba K, Salim A, Rhee P, Brown C, Browder T, DuBose J, Nomoto S, Demetriades D. Preventable morbidity at a mature trauma center. Arch Surg. 2009;144:536–41. (discussion 541–542).PubMedCrossRef
58.
go back to reference Steinwall D, Befrits F, Naidoo SR, Hardcastle T, Eriksson A, Muckart DJ. Deaths at a level 1 trauma unit: a clinical finding and post-mortem correlation study. Injury. 2012;43(1):91–5. Steinwall D, Befrits F, Naidoo SR, Hardcastle T, Eriksson A, Muckart DJ. Deaths at a level 1 trauma unit: a clinical finding and post-mortem correlation study. Injury. 2012;43(1):91–5.
60.
go back to reference Pfeifer R, Pape HC. Missed injuries in trauma patients: a literature review. Patient Saf Surg. 2008;2:20.PubMedCrossRef Pfeifer R, Pape HC. Missed injuries in trauma patients: a literature review. Patient Saf Surg. 2008;2:20.PubMedCrossRef
61.
go back to reference Robertson R, Mattox R, Collins T, Parks-Miller C, Eidt J, Cone J. Missed injuries in a rural area trauma center. Am J Surg. 1996;172:564–7. (discussion 567–8).PubMedCrossRef Robertson R, Mattox R, Collins T, Parks-Miller C, Eidt J, Cone J. Missed injuries in a rural area trauma center. Am J Surg. 1996;172:564–7. (discussion 567–8).PubMedCrossRef
62.
go back to reference Buduhan G, McRitchie DI. Missed injuries in patients with multiple trauma. J Trauma. 2000;49:600–5.PubMedCrossRef Buduhan G, McRitchie DI. Missed injuries in patients with multiple trauma. J Trauma. 2000;49:600–5.PubMedCrossRef
63.
go back to reference Amalberti R, Auroy Y, Berwick D, Barach P. Five system barriers to achieving ultrasafe health care. Ann Intern Med. 2005;142:756–64.PubMed Amalberti R, Auroy Y, Berwick D, Barach P. Five system barriers to achieving ultrasafe health care. Ann Intern Med. 2005;142:756–64.PubMed
64.
go back to reference Rieger M, Czermak B, El Attal R, Sumann G, Jaschke W, Freund M. Initial clinical experience with a 64-MDCT whole-body scanner in an emergency department: better time management and diagnostic quality? J Trauma. 2009;66:648–57.PubMedCrossRef Rieger M, Czermak B, El Attal R, Sumann G, Jaschke W, Freund M. Initial clinical experience with a 64-MDCT whole-body scanner in an emergency department: better time management and diagnostic quality? J Trauma. 2009;66:648–57.PubMedCrossRef
65.
go back to reference Wurmb TE, Fruhwald P, Hopfner W, Keil T, Kredel M, Brederlau J, Roewer N, Kuhnigk H. Whole-body multislice computed tomography as the first line diagnostic tool in patients with multiple injuries: the focus on time. J Trauma. 2009;66:658–65.PubMedCrossRef Wurmb TE, Fruhwald P, Hopfner W, Keil T, Kredel M, Brederlau J, Roewer N, Kuhnigk H. Whole-body multislice computed tomography as the first line diagnostic tool in patients with multiple injuries: the focus on time. J Trauma. 2009;66:658–65.PubMedCrossRef
66.
go back to reference Philipp MO, Kubin K, Hormann M, Metz VM. Radiological emergency room management with emphasis on multidetector-row CT. Eur J Radiol. 2003;48:2–4.PubMedCrossRef Philipp MO, Kubin K, Hormann M, Metz VM. Radiological emergency room management with emphasis on multidetector-row CT. Eur J Radiol. 2003;48:2–4.PubMedCrossRef
67.
go back to reference Lawson CM, Daley BJ, Ormsby CB, Enderson B. Missed injuries in the era of the trauma scan. J Trauma. 2011;70:452–6. (discussion 456–8).PubMedCrossRef Lawson CM, Daley BJ, Ormsby CB, Enderson B. Missed injuries in the era of the trauma scan. J Trauma. 2011;70:452–6. (discussion 456–8).PubMedCrossRef
68.
go back to reference Huber-Wagner S, Lefering R, Qvick LM, Korner M, Kay MV, Pfeifer KJ, Reiser M, Mutschler W, Kanz KG. Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373:1455–61.PubMedCrossRef Huber-Wagner S, Lefering R, Qvick LM, Korner M, Kay MV, Pfeifer KJ, Reiser M, Mutschler W, Kanz KG. Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373:1455–61.PubMedCrossRef
69.
go back to reference Deunk J, Brink M, Dekker HM, Kool DR, Blickman JG, van Vugt AB, Edwards MJ. Routine versus selective multidetector-row computed tomography (MDCT) in blunt trauma patients: level of agreement on the influence of additional findings on management. J Trauma. 2009;67:1080–6.PubMedCrossRef Deunk J, Brink M, Dekker HM, Kool DR, Blickman JG, van Vugt AB, Edwards MJ. Routine versus selective multidetector-row computed tomography (MDCT) in blunt trauma patients: level of agreement on the influence of additional findings on management. J Trauma. 2009;67:1080–6.PubMedCrossRef
70.
go back to reference Linsenmaier U, Krotz M, Hauser H, Rock C, Rieger J, Bohndorf K, Pfeifer KJ, Reiser M. Whole-body computed tomography in polytrauma: techniques and management. Eur Radiol. 2002;12:1728–40.PubMedCrossRef Linsenmaier U, Krotz M, Hauser H, Rock C, Rieger J, Bohndorf K, Pfeifer KJ, Reiser M. Whole-body computed tomography in polytrauma: techniques and management. Eur Radiol. 2002;12:1728–40.PubMedCrossRef
71.
go back to reference Agostini C, Durieux M, Milot L, Kamaoui I, Floccard B, Allaouchiche B, Pilleul F. Value of double reading of whole body CT in polytrauma patients. J Radiol. 2008;89:325–30.PubMedCrossRef Agostini C, Durieux M, Milot L, Kamaoui I, Floccard B, Allaouchiche B, Pilleul F. Value of double reading of whole body CT in polytrauma patients. J Radiol. 2008;89:325–30.PubMedCrossRef
72.
go back to reference Eurin M, Haddad N, Zappa M, Lenoir T, Dauzac C, Vilgrain V, Mantz J, Paugam-Burtz C. Incidence and predictors of missed injuries in trauma patients in the initial hot report of whole-body CT scan. Injury. 2012;43(1):73–7. Eurin M, Haddad N, Zappa M, Lenoir T, Dauzac C, Vilgrain V, Mantz J, Paugam-Burtz C. Incidence and predictors of missed injuries in trauma patients in the initial hot report of whole-body CT scan. Injury. 2012;43(1):73–7.
74.
go back to reference Stein SC, Burnett MG, Glick HA. Indications for CT scanning in mild traumatic brain injury: a cost-effectiveness study. J Trauma. 2006;61:558–66.PubMedCrossRef Stein SC, Burnett MG, Glick HA. Indications for CT scanning in mild traumatic brain injury: a cost-effectiveness study. J Trauma. 2006;61:558–66.PubMedCrossRef
75.
go back to reference Blackmore CC, Mann FA, Wilson AJ. Helical CT in the primary trauma evaluation of the cervical spine: an evidence-based approach. Skeletal Radiol. 2000;29:632–9.PubMedCrossRef Blackmore CC, Mann FA, Wilson AJ. Helical CT in the primary trauma evaluation of the cervical spine: an evidence-based approach. Skeletal Radiol. 2000;29:632–9.PubMedCrossRef
76.
go back to reference Grogan EL, Morris JA Jr, Dittus RS, Moore DE, Poulose BK, Diaz JJ, Speroff T. Cervical spine evaluation in urban trauma centers: lowering institutional costs and complications through helical CT scan. J Am Coll Surg. 2005;200:160–5.PubMedCrossRef Grogan EL, Morris JA Jr, Dittus RS, Moore DE, Poulose BK, Diaz JJ, Speroff T. Cervical spine evaluation in urban trauma centers: lowering institutional costs and complications through helical CT scan. J Am Coll Surg. 2005;200:160–5.PubMedCrossRef
77.
go back to reference Ratnapalan S, Bona N, Chandra K, Koren G. Physicians’ perceptions of teratogenic risk associated with radiography and CT during early pregnancy. AJR Am J Roentgenol. 2004;182:1107–9.PubMed Ratnapalan S, Bona N, Chandra K, Koren G. Physicians’ perceptions of teratogenic risk associated with radiography and CT during early pregnancy. AJR Am J Roentgenol. 2004;182:1107–9.PubMed
78.
go back to reference Lavine MA. Cultural history of radiation and radioactivity in the United States, 1895–1945. Madison: University of Wisconsin-Madison; 2008. Lavine MA. Cultural history of radiation and radioactivity in the United States, 1895–1945. Madison: University of Wisconsin-Madison; 2008.
79.
go back to reference Favus MJ, Schneider AB, Stachura ME, Arnold JE, Ryo UY, Pinsky SM, Colman M, Arnold MJ, Frohman LA. Thyroid cancer occurring as a late consequence of head-and-neck irradiation. Evaluation of, 1056 patients. N Engl J Med. 1976;294:1019–25.PubMedCrossRef Favus MJ, Schneider AB, Stachura ME, Arnold JE, Ryo UY, Pinsky SM, Colman M, Arnold MJ, Frohman LA. Thyroid cancer occurring as a late consequence of head-and-neck irradiation. Evaluation of, 1056 patients. N Engl J Med. 1976;294:1019–25.PubMedCrossRef
80.
go back to reference Adams MJ, Shore RE, Dozier A, Lipshultz SE, Schwartz RG, Constine LS, Pearson TA, Stovall M, Thevenet-Morrison K, Fisher SG. Thyroid cancer risk 40+ years after irradiation for an enlarged thymus: an update of the Hempelmann cohort. Radiat Res. 2010;174:753–62.PubMedCrossRef Adams MJ, Shore RE, Dozier A, Lipshultz SE, Schwartz RG, Constine LS, Pearson TA, Stovall M, Thevenet-Morrison K, Fisher SG. Thyroid cancer risk 40+ years after irradiation for an enlarged thymus: an update of the Hempelmann cohort. Radiat Res. 2010;174:753–62.PubMedCrossRef
81.
82.
go back to reference Bisconti AS. Communicating with stakeholders about nuclear power plant radiation. Health Phys. 2011;100:97–102.PubMedCrossRef Bisconti AS. Communicating with stakeholders about nuclear power plant radiation. Health Phys. 2011;100:97–102.PubMedCrossRef
83.
84.
go back to reference Jablon S, Hrubec Z, Boice JD Jr. Cancer in populations living near nuclear facilities. A survey of mortality nationwide and incidence in two states. JAMA. 1991;265:1403–8.PubMedCrossRef Jablon S, Hrubec Z, Boice JD Jr. Cancer in populations living near nuclear facilities. A survey of mortality nationwide and incidence in two states. JAMA. 1991;265:1403–8.PubMedCrossRef
85.
go back to reference Aydin D, Feychting M, Schuz J, Tynes T, Andersen TV, Schmidt LS, Poulsen AH, Johansen C, Prochazka M, Lannering B, Klaeboe L, Eggen T, Jenni D, Grotzer M, Von der Weid N, Kuehni CE, Roosli M. Mobile phone use and brain tumors in children and adolescents: a multicenter case-control study. J Natl Cancer Inst. 2011;103:1264–76.PubMedCrossRef Aydin D, Feychting M, Schuz J, Tynes T, Andersen TV, Schmidt LS, Poulsen AH, Johansen C, Prochazka M, Lannering B, Klaeboe L, Eggen T, Jenni D, Grotzer M, Von der Weid N, Kuehni CE, Roosli M. Mobile phone use and brain tumors in children and adolescents: a multicenter case-control study. J Natl Cancer Inst. 2011;103:1264–76.PubMedCrossRef
86.
go back to reference Huss A, Spoerri A, Egger M, Roosli M. Residence near power lines and mortality from neurodegenerative diseases: longitudinal study of the Swiss population. Am J Epidemiol. 2009;169:167–75.PubMedCrossRef Huss A, Spoerri A, Egger M, Roosli M. Residence near power lines and mortality from neurodegenerative diseases: longitudinal study of the Swiss population. Am J Epidemiol. 2009;169:167–75.PubMedCrossRef
87.
go back to reference Jenkins-Smith HC, Silva CL, Murray C. Beliefs about radiation: scientists, the public and public policy. Health Phys. 2009;97:519–27.PubMedCrossRef Jenkins-Smith HC, Silva CL, Murray C. Beliefs about radiation: scientists, the public and public policy. Health Phys. 2009;97:519–27.PubMedCrossRef
88.
go back to reference Mihai LT, Milu C, Voicu B, Enachescu D. Ionizing radiation—understanding and acceptance. Health Phys. 2005;89:375–82.PubMedCrossRef Mihai LT, Milu C, Voicu B, Enachescu D. Ionizing radiation—understanding and acceptance. Health Phys. 2005;89:375–82.PubMedCrossRef
89.
go back to reference Mandelblatt JS, Cronin KA, Berry DA, Chang Y, de Koning HJ, Lee SJ, Plevritis SK, Schechter CB, Stout NK, van Ravesteyn NT, Zelen M, Feuer EJ. Modeling the impact of population screening on breast cancer mortality in the United States. Breast. 2011;20[Suppl 3]:S75–81.PubMedCrossRef Mandelblatt JS, Cronin KA, Berry DA, Chang Y, de Koning HJ, Lee SJ, Plevritis SK, Schechter CB, Stout NK, van Ravesteyn NT, Zelen M, Feuer EJ. Modeling the impact of population screening on breast cancer mortality in the United States. Breast. 2011;20[Suppl 3]:S75–81.PubMedCrossRef
90.
go back to reference Linton OW, Mettler FA Jr. National conference on dose reduction in CT, with an emphasis on pediatric patients. AJR Am J Roentgenol. 2003;181:321–9.PubMed Linton OW, Mettler FA Jr. National conference on dose reduction in CT, with an emphasis on pediatric patients. AJR Am J Roentgenol. 2003;181:321–9.PubMed
91.
go back to reference Huda W, He W. Estimating cancer risks to adults undergoing body CT examinations. Radiat Prot Dosimetry. 2012;150:168–79.PubMedCrossRef Huda W, He W. Estimating cancer risks to adults undergoing body CT examinations. Radiat Prot Dosimetry. 2012;150:168–79.PubMedCrossRef
93.
go back to reference Jaffe TA, Yoshizumi TT, Toncheva G, Anderson-Evans C, Lowry C, Miller CM, Nelson RC, Ravin CE. Radiation dose for body CT protocols: variability of scanners at one institution. AJR Am J Roentgenol. 2009;193:1141–7.PubMedCrossRef Jaffe TA, Yoshizumi TT, Toncheva G, Anderson-Evans C, Lowry C, Miller CM, Nelson RC, Ravin CE. Radiation dose for body CT protocols: variability of scanners at one institution. AJR Am J Roentgenol. 2009;193:1141–7.PubMedCrossRef
94.
go back to reference Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de Gonzalez A, Miglioretti DL. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009;169:2078–86.PubMedCrossRef Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de Gonzalez A, Miglioretti DL. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med. 2009;169:2078–86.PubMedCrossRef
95.
go back to reference Mayo JR, Whittall KP, Leung AN, Hartman TE, Park CS, Primack SL, Chambers GK, Limkeman MK, Toth TL, Fox SH. Simulated dose reduction in conventional chest CT: validation study. Radiology. 1997;202:453–7.PubMed Mayo JR, Whittall KP, Leung AN, Hartman TE, Park CS, Primack SL, Chambers GK, Limkeman MK, Toth TL, Fox SH. Simulated dose reduction in conventional chest CT: validation study. Radiology. 1997;202:453–7.PubMed
96.
go back to reference Mulkens TH, Marchal P, Daineffe S, Salgado R, Bellinck P, te Rijdt B, Kegelaers B, Termote JL. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28:1444–50.PubMedCrossRef Mulkens TH, Marchal P, Daineffe S, Salgado R, Bellinck P, te Rijdt B, Kegelaers B, Termote JL. Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma. AJNR Am J Neuroradiol. 2007;28:1444–50.PubMedCrossRef
97.
go back to reference Cook SH, Fielding JR, Phillips JD. Repeat abdominal computed tomography scans after pediatric blunt abdominal trauma: missed injuries, extra costs, and unnecessary radiation exposure. J Pediatr Surg. 2010;45:2019–24.PubMedCrossRef Cook SH, Fielding JR, Phillips JD. Repeat abdominal computed tomography scans after pediatric blunt abdominal trauma: missed injuries, extra costs, and unnecessary radiation exposure. J Pediatr Surg. 2010;45:2019–24.PubMedCrossRef
98.
go back to reference Hashem R, Evans CC, Farrokhyar F, Kahnamoui K. Plain radiography does not add any clinically significant advantage to multidetector row computed tomography in diagnosing cervical spine injuries in blunt trauma patients. J Trauma. 2009;66:423–8.PubMedCrossRef Hashem R, Evans CC, Farrokhyar F, Kahnamoui K. Plain radiography does not add any clinically significant advantage to multidetector row computed tomography in diagnosing cervical spine injuries in blunt trauma patients. J Trauma. 2009;66:423–8.PubMedCrossRef
99.
go back to reference Ptak T, Rhea JT, Novelline RA. Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience. Radiology. 2003;229:902–5.PubMedCrossRef Ptak T, Rhea JT, Novelline RA. Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience. Radiology. 2003;229:902–5.PubMedCrossRef
100.
go back to reference Fanucci E, Fiaschetti V, Rotili A, Floris R, Simonetti G. Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure. Emerg Radiol. 2007;13:251–7.PubMedCrossRef Fanucci E, Fiaschetti V, Rotili A, Floris R, Simonetti G. Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure. Emerg Radiol. 2007;13:251–7.PubMedCrossRef
101.
go back to reference Langner S, Fleck S, Kirsch M, Petrik M, Hosten N. Whole-body CT trauma imaging with adapted and optimized CT angiography of the craniocervical vessels: do we need an extra screening examination? AJNR Am J Neuroradiol. 2008;29:1902–7.PubMedCrossRef Langner S, Fleck S, Kirsch M, Petrik M, Hosten N. Whole-body CT trauma imaging with adapted and optimized CT angiography of the craniocervical vessels: do we need an extra screening examination? AJNR Am J Neuroradiol. 2008;29:1902–7.PubMedCrossRef
102.
go back to reference de Gonzalez AB, Brenner A, Hartge P, Lee C, Morton L, Rajaraman P. Evolving strategies in epidemiologic research on radiation and cancer. Radiat Res. 2011;176:527–32.PubMedCrossRef de Gonzalez AB, Brenner A, Hartge P, Lee C, Morton L, Rajaraman P. Evolving strategies in epidemiologic research on radiation and cancer. Radiat Res. 2011;176:527–32.PubMedCrossRef
Metadata
Title
Whole body imaging in the diagnosis of blunt trauma, ionizing radiation hazards and residual risk
Publication date
01-02-2013
Published in
European Journal of Trauma and Emergency Surgery / Issue 1/2013
Print ISSN: 1863-9933
Electronic ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-012-0201-2

Other articles of this Issue 1/2013

European Journal of Trauma and Emergency Surgery 1/2013 Go to the issue