The impact of the Harmonic FOCUS™ on complications in thyroid surgery: a prospective multicenter study

Authors: Gabriele Materazzi, Giuseppe Caravaglios, Valeria Matteucci, Aleksandr Aghababyan, Mario Miccoli, Paolo Miccoli

Published in: Updates in Surgery | Issue 4/2013

Login to get access

Abstract

In recent years, newer tools have been developed and used in thyroid surgery. This study compared patients with multinodular goiter undergoing thyroidectomy using the Harmonic FOCUS™ with patients undergoing the clamp-and-tie technique. Medical records of 268 patients with multinodular goiter undergoing thyroidectomy from December 2006 to July 2011 in two centers in Italy, the Department of Surgery of Pisa and the General Surgery Unit of Grosseto, were prospectively evaluated. Patients were divided into group A (Harmonic FOCUS™ Shear), and group B (clamp-and-tie technique). Patient demographics and specific end points analyzed included age, sex, diagnosis, thyroid gland volume, operative time, complications, need for clips and hemostatic agents, need for suction balloon, postoperative blood loss, and postoperative hospital length of stay. 141 patients were included in group A, and 127 patients were included in group B. The two groups were similar in age, sex ratio, indication for surgery, and thyroid volume. Mean operative time was significantly shorter with the Harmonic FOCUS™ Shear (51.8 min) than with the clamp-and-tie technique (70.9 min). The mean postoperative amount obtained from the suction balloon was similar. Vascular clips were needed significantly more frequently in group A (26.2 %) than in group B (12.5 %), whereas the need for hemostatic agents was significantly reduced in group A (4.2 %) compared with group B (14.9 %). The decision to leave a suction drain at the end of the operation occurred significantly more frequently in group B (96 %) than in group A (78 %). Mean postoperative hospital length of stay was 2.02 days in group A compared with 3.1 days in group B, which was significant. No definitive postoperative complications were documented in either group, except a higher rate, but not statistically significant, of permanent hypoparathyroidism in group B versus Group A. Transient laryngeal nerve injury was similar in both groups, whereas transient hypoparathyroidism occurred more frequently in Group B (4.7 %) than in Group A (2.4 %). Harmonic FOCUS device was significantly associated with lower rate of postoperative transient hypocalcemia, decreased operative time, shorter hospitalization, and lesser need for hemostatic agents and postoperative drain balloon. These results might be considered “indirect” money-saving factors, despite the cost of the device, especially in countries where the cost of thyroidectomy is influenced also by the hospital length of stay.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years. World J Surg 28(3):271–276PubMedCrossRef Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years. World J Surg 28(3):271–276PubMedCrossRef
3.
go back to reference Linos D (2011) Minimally invasive thyroidectomy: a comprehensive appraisal of existing techniques. Surgery 150(1):17–24. Epub 2011 May 18. Review Linos D (2011) Minimally invasive thyroidectomy: a comprehensive appraisal of existing techniques. Surgery 150(1):17–24. Epub 2011 May 18. Review
4.
go back to reference Lee J, Kang SW, Jung JJ, Choi UJ, Yun JH, Nam KH, Soh EY, Chung WY (2011) Multicenter study of robotic thyroidectomy: short-term postoperative outcomes and surgeon ergonomic considerations. Ann Surg Oncol 18(9):2538–2547PubMedCrossRef Lee J, Kang SW, Jung JJ, Choi UJ, Yun JH, Nam KH, Soh EY, Chung WY (2011) Multicenter study of robotic thyroidectomy: short-term postoperative outcomes and surgeon ergonomic considerations. Ann Surg Oncol 18(9):2538–2547PubMedCrossRef
5.
go back to reference Muenscher A, Dalchow C, Kutta H, Knecht R (2011) The endoscopic approach to the neck: a review of the literature, and overview of the various techniques. Surg Endosc 25(5):1358–63. Epub 2010 Dec 7. Review Muenscher A, Dalchow C, Kutta H, Knecht R (2011) The endoscopic approach to the neck: a review of the literature, and overview of the various techniques. Surg Endosc 25(5):1358–63. Epub 2010 Dec 7. Review
6.
go back to reference Miccoli P, Materazzi G. Minimally invasive, video-assisted thyroidectomy (MIVAT) Surg Clin North Am. 2004 Jun;84(3):735-41 Miccoli P, Materazzi G. Minimally invasive, video-assisted thyroidectomy (MIVAT) Surg Clin North Am. 2004 Jun;84(3):735-41
7.
go back to reference Dionigi G, Boni L, Rausei S, Frattini F, Ferrari CC, Mangano A, Leotta A, Franchin M (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS. Langenbecks Arch Surg. (Epub ahead of print) Dionigi G, Boni L, Rausei S, Frattini F, Ferrari CC, Mangano A, Leotta A, Franchin M (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS. Langenbecks Arch Surg. (Epub ahead of print)
8.
go back to reference Manouras A, Markogiannakis H, Koutras AS et al (2008) Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 195(1):48–52PubMed Manouras A, Markogiannakis H, Koutras AS et al (2008) Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 195(1):48–52PubMed
9.
go back to reference Shen WT, Baumbusch MA, Kebebew E, Duh QY (2005) Use of the electrothermal vessel sealing system versus standard vessel ligation in thyroidectomy. Asian J Surg 28(2):86–89PubMedCrossRef Shen WT, Baumbusch MA, Kebebew E, Duh QY (2005) Use of the electrothermal vessel sealing system versus standard vessel ligation in thyroidectomy. Asian J Surg 28(2):86–89PubMedCrossRef
10.
go back to reference Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740PubMedCrossRef Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740PubMedCrossRef
11.
go back to reference Kilic M, Keskek M, Ertan T, Yoldas O, Bilgin A, Koc M (2007) A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 24(3):632–638PubMedCrossRef Kilic M, Keskek M, Ertan T, Yoldas O, Bilgin A, Koc M (2007) A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 24(3):632–638PubMedCrossRef
12.
go back to reference Prgomet D, Janjanin S, Bilić M et al (2009) A prospective observational study of 363 cases operated with three different harmonic scalpels. Eur Arch Otorhinolaryngol 266(12):1965–1970PubMedCrossRef Prgomet D, Janjanin S, Bilić M et al (2009) A prospective observational study of 363 cases operated with three different harmonic scalpels. Eur Arch Otorhinolaryngol 266(12):1965–1970PubMedCrossRef
13.
go back to reference Mourad M, Rulli F, Robert A, Scholtes JL, De Meyer M, De Pauw L (2011) Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy. Am J Surg 202(2):168–174PubMedCrossRef Mourad M, Rulli F, Robert A, Scholtes JL, De Meyer M, De Pauw L (2011) Randomized clinical trial on Harmonic Focus shears versus clamp-and-tie technique for total thyroidectomy. Am J Surg 202(2):168–174PubMedCrossRef
14.
go back to reference Ferri E, Armato E, Spinato G, Spinato R (2011) Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial. Int J Otolaryngol 2011:357195. (Epub 2011 Sep 29) Ferri E, Armato E, Spinato G, Spinato R (2011) Focus harmonic scalpel compared to conventional haemostasis in open total thyroidectomy: a prospective randomized trial. Int J Otolaryngol 2011:357195. (Epub 2011 Sep 29)
15.
go back to reference Sebag F, Fortanier C et al (2009) Harmonic scalpel in multinodular goiter surgery: impact on surgery and cost analysis. J Laparoendosc Adv Surg Tech A 19(2):171–174PubMed Sebag F, Fortanier C et al (2009) Harmonic scalpel in multinodular goiter surgery: impact on surgery and cost analysis. J Laparoendosc Adv Surg Tech A 19(2):171–174PubMed
16.
go back to reference Lombardi CP, Raffaelli M et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393(5):627–631PubMedCrossRef Lombardi CP, Raffaelli M et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393(5):627–631PubMedCrossRef
17.
go back to reference Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the Ultracision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14(1):9–12PubMed Ortega J, Sala C, Flor B, Lledo S (2004) Efficacy and cost-effectiveness of the Ultracision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14(1):9–12PubMed
18.
go back to reference Fujita T, Doihara H, Ogasawara Y, Shimizu N (2006) Utility of vessel-sealing systems in thyroid surgery. Acta Med Okayama 60:93–98PubMed Fujita T, Doihara H, Ogasawara Y, Shimizu N (2006) Utility of vessel-sealing systems in thyroid surgery. Acta Med Okayama 60:93–98PubMed
19.
go back to reference Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29:771–774PubMedCrossRef Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29:771–774PubMedCrossRef
20.
go back to reference Kiriakopoulos A, Dimitrios T, Dimitrios L (2004) Use of a diathermy system in thyroid surgery. Arch Surg 139:997–1000PubMedCrossRef Kiriakopoulos A, Dimitrios T, Dimitrios L (2004) Use of a diathermy system in thyroid surgery. Arch Surg 139:997–1000PubMedCrossRef
21.
go back to reference Lachanas VA, Prokopakis EP, Mpenakis AA et al (2005) The use of ligasure vessel sealing system in thyroid surgery. Otolaryngol Head Neck Surg 132:487–489PubMedCrossRef Lachanas VA, Prokopakis EP, Mpenakis AA et al (2005) The use of ligasure vessel sealing system in thyroid surgery. Otolaryngol Head Neck Surg 132:487–489PubMedCrossRef
22.
go back to reference Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231:322–328PubMedCrossRef Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231:322–328PubMedCrossRef
23.
go back to reference Pardal-Refoyo JL (2011) Hemostatic systems in thyroid surgery and complications Acta Otorhinolaringol Esp 62(5):339–46. (Epub 2011 May 6) Pardal-Refoyo JL (2011) Hemostatic systems in thyroid surgery and complications Acta Otorhinolaringol Esp 62(5):339–46. (Epub 2011 May 6)
24.
go back to reference Defechereux T, Rinken F, Maweja S, Hamoir E, Meurisse M (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277PubMed Defechereux T, Rinken F, Maweja S, Hamoir E, Meurisse M (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277PubMed
25.
go back to reference Miccoli P, Berti P, Dionigi GL, D’Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073PubMedCrossRef Miccoli P, Berti P, Dionigi GL, D’Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073PubMedCrossRef
26.
go back to reference Cordón C, Fajardo R, Ramírez J, Herrera MF (2005) A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy. Surgery 137(3):337–341PubMedCrossRef Cordón C, Fajardo R, Ramírez J, Herrera MF (2005) A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy. Surgery 137(3):337–341PubMedCrossRef
27.
go back to reference He Q, Zhuang D, Zheng L, Zhou P, Chai J, Lv Z (2011) Harmonic focus in total thyroidectomy plus level III–IV and VI dissection: a prospective randomized study. World J Surg Oncol 31(9):141CrossRef He Q, Zhuang D, Zheng L, Zhou P, Chai J, Lv Z (2011) Harmonic focus in total thyroidectomy plus level III–IV and VI dissection: a prospective randomized study. World J Surg Oncol 31(9):141CrossRef
28.
go back to reference Markogiannakis H, Kekis PB, Memos N, Alevizos L, Tsamis D, Michalopoulos NV (2011) Thyroid surgery with the new harmonic scalpel: a prospective randomized study. Surgery 149:411–415PubMedCrossRef Markogiannakis H, Kekis PB, Memos N, Alevizos L, Tsamis D, Michalopoulos NV (2011) Thyroid surgery with the new harmonic scalpel: a prospective randomized study. Surgery 149:411–415PubMedCrossRef
Metadata
Title
The impact of the Harmonic FOCUS™ on complications in thyroid surgery: a prospective multicenter study
Authors
Gabriele Materazzi
Giuseppe Caravaglios
Valeria Matteucci
Aleksandr Aghababyan
Mario Miccoli
Paolo Miccoli
Publication date
01-12-2013
Publisher
Springer Milan
Published in
Updates in Surgery / Issue 4/2013
Print ISSN: 2038-131X
Electronic ISSN: 2038-3312
DOI
https://doi.org/10.1007/s13304-013-0223-2

Other articles of this Issue 4/2013

Updates in Surgery 4/2013 Go to the issue