Skip to main content
Top
Published in: Updates in Surgery 4/2011

01-12-2011 | Original Article

Harmonic Focus™ versus “knot tying” during total thyroidectomy: a randomized trial

Authors: Paolo Gentileschi, Stefano D’Ugo, Edoardo Iaculli, Achille Lucio Gaspari

Published in: Updates in Surgery | Issue 4/2011

Login to get access

Abstract

The objective of the study is to compare the outcome of total thyroidectomy (TT) using the Harmonic Focus™ (HF) versus conventional “knot tying” (KT) in terms of operative time, parathyroid function and post-operative complications. This prospective study was designed with a random allocation of subjects using a drawing technique. Eighty-one consecutive patients were submitted to TT in 2010 and randomly divided into two groups: 43 patients operated using HF (HF group) and 38 patients operated using KT (KT group). Parathyroid function was evaluated by parathyroid hormone (PTH) level at 1 h postoperatively and calcium level at first post-operative day. Indications for medical therapy were PTH < 15 pg/ml and/or calcium < 8.0 mg/dl and/or clinical signs or symptoms of hypocalcemia. Main outcomes were operative time, PTH and calcium levels, need for medical therapy and post-operative complications. Mean operative time was significantly lower in HF group compared with KT group (100 ± 34 vs. 119 ± 30 min). There were no significant differences concerning transient hypoparathyroidism requiring calcium and/or vitamin D therapy: 17 patients (39.5%) in HF group versus 21 (55.3%) in KT group. Five patients (11.6%) in HF group experienced symptomatic hypocalcemia versus 6 (15.8%) in KT group, without statistically significant difference. No patients experienced recurrent nerve injury. HF is a new ergonomic, reliable device developed for thyroid surgery. According to our results, HF is a safe, time-saving alternative to “knot tying” thyroidectomy, with no influence on parathyroid function, medical therapy and nerve injury.
Literature
1.
go back to reference Kocher T (1883) Uber kropfextirpation und ihre Folgen. Arciv fur Klinische Chirurgie 29:254–337 Kocher T (1883) Uber kropfextirpation und ihre Folgen. Arciv fur Klinische Chirurgie 29:254–337
2.
go back to reference Delbridge L (2003) Total thyroidectomy: the evolution of surgical technique. ANZ J Surg 73:761–768PubMedCrossRef Delbridge L (2003) Total thyroidectomy: the evolution of surgical technique. ANZ J Surg 73:761–768PubMedCrossRef
3.
go back to reference Koyuncu A, Dokmetas HS, Turan M et al (2003) Comparison of different thyroidectomy techniques for benign thyroid disease. Endocr J 50:723–727PubMedCrossRef Koyuncu A, Dokmetas HS, Turan M et al (2003) Comparison of different thyroidectomy techniques for benign thyroid disease. Endocr J 50:723–727PubMedCrossRef
4.
go back to reference Bliss RD, Gauger PG, Delbridge LW (2000) Surgeon’s approach to the thyroid gland: surgical anatomy and the importance of technique. World J Surg 24(8):891–897PubMedCrossRef Bliss RD, Gauger PG, Delbridge LW (2000) Surgeon’s approach to the thyroid gland: surgical anatomy and the importance of technique. World J Surg 24(8):891–897PubMedCrossRef
5.
go back to reference Kekis PB, Smith SGT, Lynn JA et al (2007) Complications in endocrine surgery. In: Hakim NS, Papalois VE (eds) Surgical complications. Diagnosis and treatment. Imperial College Press, London, pp 505–566CrossRef Kekis PB, Smith SGT, Lynn JA et al (2007) Complications in endocrine surgery. In: Hakim NS, Papalois VE (eds) Surgical complications. Diagnosis and treatment. Imperial College Press, London, pp 505–566CrossRef
6.
go back to reference Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231:322–328PubMedCrossRef Voutilainen PE, Haglund CH (2000) Ultrasonically activated shears in thyroidectomies: a randomized trial. Ann Surg 231:322–328PubMedCrossRef
7.
go back to reference Ortega J, Sala C, Flor B et al (2004) Efficacy and cost-effectiveness of the Ultracision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14:9–12PubMedCrossRef Ortega J, Sala C, Flor B et al (2004) Efficacy and cost-effectiveness of the Ultracision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14:9–12PubMedCrossRef
8.
go back to reference Manouras A, Markogiannakis H, Koutras AS et al (2008) Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 195(1):382–384CrossRef Manouras A, Markogiannakis H, Koutras AS et al (2008) Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 195(1):382–384CrossRef
9.
go back to reference Sartori PV, De Fina S, Colombo G et al (2008) Ligasure versus Ultracision in thyroid surgery: a prospective randomized study. Langenbecks Arch Surg 393:655–658PubMedCrossRef Sartori PV, De Fina S, Colombo G et al (2008) Ligasure versus Ultracision in thyroid surgery: a prospective randomized study. Langenbecks Arch Surg 393:655–658PubMedCrossRef
10.
go back to reference Hallgrimsson P, Lovén L, Westerdahl J et al (2008) Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial. Langenbecks Arch Surg 393:675–680PubMedCrossRef Hallgrimsson P, Lovén L, Westerdahl J et al (2008) Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial. Langenbecks Arch Surg 393:675–680PubMedCrossRef
11.
go back to reference Miccoli P, Berti P, Dionigi GL et al (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073PubMedCrossRef Miccoli P, Berti P, Dionigi GL et al (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073PubMedCrossRef
12.
go back to reference Lombardi CP, Raffaelli M, Cicchetti A et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393:627–631PubMedCrossRef Lombardi CP, Raffaelli M, Cicchetti A et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393:627–631PubMedCrossRef
13.
go back to reference Maheswaran I, Isla A, Lynn J et al (2007) Haemostasis in endocrine surgery. In: Hakim NS, Canelo R (eds) Haemostasis in surgery. Imperial College Press, London, pp 189–211CrossRef Maheswaran I, Isla A, Lynn J et al (2007) Haemostasis in endocrine surgery. In: Hakim NS, Canelo R (eds) Haemostasis in surgery. Imperial College Press, London, pp 189–211CrossRef
14.
go back to reference Reeve T, Thompson NW (2000) Complications of thyroid surgery: how to avoid them, how to manage them, and observations on their possible effect on the whole patient. World J Surg 24(8):971–975PubMedCrossRef Reeve T, Thompson NW (2000) Complications of thyroid surgery: how to avoid them, how to manage them, and observations on their possible effect on the whole patient. World J Surg 24(8):971–975PubMedCrossRef
15.
go back to reference Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14, 934 patients operated on in Italy over 5 years. World J Surg 28:271–276PubMedCrossRef Rosato L, Avenia N, Bernante P et al (2004) Complications of thyroid surgery: analysis of a multicentric study on 14, 934 patients operated on in Italy over 5 years. World J Surg 28:271–276PubMedCrossRef
16.
go back to reference Kennedy JS, Stranahan PL, Taylor KD et al (1998) High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc 12(6):876–878PubMedCrossRef Kennedy JS, Stranahan PL, Taylor KD et al (1998) High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc 12(6):876–878PubMedCrossRef
17.
go back to reference Carlander J, Johansson K, Lindstrom S et al (2005) Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery. Br J Surg 92(6):772–777PubMedCrossRef Carlander J, Johansson K, Lindstrom S et al (2005) Comparison of experimental nerve injury caused by ultrasonically activated scalpel and electrosurgery. Br J Surg 92(6):772–777PubMedCrossRef
18.
go back to reference Diamantis T, Kontos M, Arvelakis A et al (2006) Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure. Surg Today 36(10):908–913PubMedCrossRef Diamantis T, Kontos M, Arvelakis A et al (2006) Comparison of monopolar electrocoagulation, bipolar electrocoagulation, Ultracision, and Ligasure. Surg Today 36(10):908–913PubMedCrossRef
19.
go back to reference Anonymous. Ultracision Harmonic Scalpel user’s manual. Ehticon Endosurgery, Cincinnati 2001 Anonymous. Ultracision Harmonic Scalpel user’s manual. Ehticon Endosurgery, Cincinnati 2001
20.
go back to reference McCarus SD (1996) Physiologic mechanism of the ultrasonically activated scalpel. J Am Assoc Gynecol Laparosc 3:601–608PubMedCrossRef McCarus SD (1996) Physiologic mechanism of the ultrasonically activated scalpel. J Am Assoc Gynecol Laparosc 3:601–608PubMedCrossRef
21.
go back to reference Gertsch P, Pelloni A, Guerra A, Krpo A (2000) Initial experience with the harmonic scalpel in liver surgery. Hepatogastroenterology 47:763–766PubMed Gertsch P, Pelloni A, Guerra A, Krpo A (2000) Initial experience with the harmonic scalpel in liver surgery. Hepatogastroenterology 47:763–766PubMed
22.
go back to reference Ohtsuka T, Wolf RK, Wurnig P et al (1998) Thoracoscopic limited pericardial resection with an ultrasonic scalpel. Ann Thorac Surg 65:855–856PubMedCrossRef Ohtsuka T, Wolf RK, Wurnig P et al (1998) Thoracoscopic limited pericardial resection with an ultrasonic scalpel. Ann Thorac Surg 65:855–856PubMedCrossRef
23.
go back to reference Aoki T, Kaseda S (1999) Thoracoscopic resection of the lung with the ultrasonic scalpel. Ann Thorac Surg 67:1181–1183PubMedCrossRef Aoki T, Kaseda S (1999) Thoracoscopic resection of the lung with the ultrasonic scalpel. Ann Thorac Surg 67:1181–1183PubMedCrossRef
24.
go back to reference Amaral JF (1994) The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Laparosc Endosc 4:92–99PubMed Amaral JF (1994) The experimental development of an ultrasonically activated scalpel for laparoscopic use. Surg Laparosc Endosc 4:92–99PubMed
25.
go back to reference Maruta F, Sugiyama A, Matsushita K et al (1999) Use of the Harmonic Scalpel in open abdominoperineal surgery for rectal carcinoma. Dis Colon Rectum 42:540–542PubMedCrossRef Maruta F, Sugiyama A, Matsushita K et al (1999) Use of the Harmonic Scalpel in open abdominoperineal surgery for rectal carcinoma. Dis Colon Rectum 42:540–542PubMedCrossRef
26.
go back to reference Karvounaris DC, Antonopolous V, Psarras K et al (2006) Efficacy and safety of ultrasonically activated shears in thyroid surgery. Head Neck 28:1028–1031PubMedCrossRef Karvounaris DC, Antonopolous V, Psarras K et al (2006) Efficacy and safety of ultrasonically activated shears in thyroid surgery. Head Neck 28:1028–1031PubMedCrossRef
27.
go back to reference Miccoli P, Materazzi G, Miccoli M et al (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199:736–740PubMedCrossRef Miccoli P, Materazzi G, Miccoli M et al (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199:736–740PubMedCrossRef
28.
go back to reference Prgomet D, Janjanin S, Bilić M et al (2009) A prospective observational study of 363 cases operated with three different harmonic scalpels. Eur Arch Otorhinolaryngol 266(12):1965–1970PubMedCrossRef Prgomet D, Janjanin S, Bilić M et al (2009) A prospective observational study of 363 cases operated with three different harmonic scalpels. Eur Arch Otorhinolaryngol 266(12):1965–1970PubMedCrossRef
29.
go back to reference Marchesi M, Biffoni M, Cresti R et al (2003) Ultrasonic scalpel in thyroid surgery. Chir Ital 55(2):299–308PubMed Marchesi M, Biffoni M, Cresti R et al (2003) Ultrasonic scalpel in thyroid surgery. Chir Ital 55(2):299–308PubMed
30.
go back to reference Grodski S, Serpell J (2008) Evidence for the role of perioperative PTH measurement after total thyroidectomy as a predictor of hypocalcemia. World J Surg 32(7):1367–1373PubMedCrossRef Grodski S, Serpell J (2008) Evidence for the role of perioperative PTH measurement after total thyroidectomy as a predictor of hypocalcemia. World J Surg 32(7):1367–1373PubMedCrossRef
31.
go back to reference Gentileschi P, Gacek IA, Manzelli A et al (2008) Early (1 hour) post-operative parathyroid hormone (PTH) measurement predicts hypocalcaemia after thyroidectomy: a prospective case-control single-institution study. Chir Ital 60(4):519–528PubMed Gentileschi P, Gacek IA, Manzelli A et al (2008) Early (1 hour) post-operative parathyroid hormone (PTH) measurement predicts hypocalcaemia after thyroidectomy: a prospective case-control single-institution study. Chir Ital 60(4):519–528PubMed
32.
go back to reference Wong C, Price S, Scott-Coombes D (2006) Hypocalcaemia and parathyroid hormone assay following total thyroidectomy: predicting the future. World J Surg 30(5):825–832PubMedCrossRef Wong C, Price S, Scott-Coombes D (2006) Hypocalcaemia and parathyroid hormone assay following total thyroidectomy: predicting the future. World J Surg 30(5):825–832PubMedCrossRef
Metadata
Title
Harmonic Focus™ versus “knot tying” during total thyroidectomy: a randomized trial
Authors
Paolo Gentileschi
Stefano D’Ugo
Edoardo Iaculli
Achille Lucio Gaspari
Publication date
01-12-2011
Publisher
Springer Milan
Published in
Updates in Surgery / Issue 4/2011
Print ISSN: 2038-131X
Electronic ISSN: 2038-3312
DOI
https://doi.org/10.1007/s13304-011-0099-y

Other articles of this Issue 4/2011

Updates in Surgery 4/2011 Go to the issue