Skip to main content
Top
Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 5/2021

01-05-2021 | Fentanyl | Reports of Original Investigations

Programmed intermittent epidural bolus for labour analgesia during first stage of labour: a sequential allocation trial to determine the effective interval time between boluses of a fixed volume of 2.5 mL of bupivacaine 0.25% plus fentanyl 8 µg·mL−1

Authors: Daniel Shatalin, MD, Cristian Arzola, MD, MSc, Kristi Downey, MSc, Xiang Y. Ye, MSc, Jose C. A. Carvalho, MD, PhD

Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Issue 5/2021

Login to get access

Abstract

Purpose

We studied the programmed intermittent epidural bolus (PIEB) time interval between boluses of 2.5 mL of bupivacaine 0.25% with fentanyl 8 µg·mL−1 to produce effective analgesia in 90% of women (EI90) during the first stage of labour.

Methods

In a double-blind sequential allocation trial using a biased coin up-and-down design to determine the EI90, the PIEB boluses of 2.5 mL of 0.25% bupivacaine plus fentanyl 8 µg·mL−1 were delivered at varying intervals—60, 50, 40, and 30 min. The primary outcome was the adequate response of the patient to the PIEB regimen, defined as no use of supplemental analgesia for six hours or until the first stage of labour was completed, whichever came first. The secondary outcomes were the upper sensory block level to ice, motor block and hypotension. The isotonic regression with extrapolation approach was used to estimate the EI90.

Results

In the 20 women studied, the estimated EI90 was 20 (95% CI, 5.9 to 28.8) min. For the secondary outcomes, we classified women into those assigned to 30 min (16 women) and those assigned to more than 30 min (four women). The median upper sensory block for women in the 30-min group and more than 30 min were T6 (or T5) and T7, respectively. No participants experienced motor block. Hypotension occurred in one patient in the 30-min group.

Conclusion

The estimated EI90 for boluses of 2.5 mL of bupivacaine 0.25% with fentanyl 8 µg·mL−1 was 20 (95% CI, 5.9 to 28.8) min. These results suggest that there is no advantage in using this regimen compared with those reported in the literature using the same dose of bupivacaine in concentrations of 0.0625% and 0.125%.

Trial registration

www.​clinicaltrials.​gov (NCT03735771); registered 7 November 2018.
Literature
1.
go back to reference Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg 2006; 102: 904-9.CrossRef Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg 2006; 102: 904-9.CrossRef
2.
go back to reference Fettes PD, Moore CS, Whiteside JB, McLeod GA, Wildsmith JA. Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour. Br J Anaesth 2006; 97: 359-64.CrossRef Fettes PD, Moore CS, Whiteside JB, McLeod GA, Wildsmith JA. Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour. Br J Anaesth 2006; 97: 359-64.CrossRef
3.
go back to reference Sia AT, Lim Y, Ocampo C. A comparison of a basal infusion with automated mandatory boluses in parturient-controlled epidural analgesia during labor. Anesth Analg 2007; 104: 673-8.CrossRef Sia AT, Lim Y, Ocampo C. A comparison of a basal infusion with automated mandatory boluses in parturient-controlled epidural analgesia during labor. Anesth Analg 2007; 104: 673-8.CrossRef
4.
go back to reference Leo S, Ocampo CE, Lim Y, Sia AT. A randomized comparison of automated intermittent mandatory boluses with a basal infusion in combination with patient-controlled epidural analgesia for labor and delivery. Int J Obstet Anesth 2010; 19: 357-64.CrossRef Leo S, Ocampo CE, Lim Y, Sia AT. A randomized comparison of automated intermittent mandatory boluses with a basal infusion in combination with patient-controlled epidural analgesia for labor and delivery. Int J Obstet Anesth 2010; 19: 357-64.CrossRef
5.
go back to reference Capogna G, Camorcia M, Stirparo S, Farcomeni A. Programmed intermittent epidural bolus versus continuous epidural infusion for labor analgesia: the effects on maternal motor function and labor outcome. A randomized double-blind study in nulliparous women. Anesth Analg 2011; 113: 826-31.CrossRef Capogna G, Camorcia M, Stirparo S, Farcomeni A. Programmed intermittent epidural bolus versus continuous epidural infusion for labor analgesia: the effects on maternal motor function and labor outcome. A randomized double-blind study in nulliparous women. Anesth Analg 2011; 113: 826-31.CrossRef
6.
go back to reference Wong CA, McCarthy RJ, Hewlett B. The effect of manipulation of the programmed intermittent bolus time interval and injection volume on total drug use for labor epidural analgesia: a randomized controlled trial. Anesth Analg 2011; 112: 904-11.CrossRef Wong CA, McCarthy RJ, Hewlett B. The effect of manipulation of the programmed intermittent bolus time interval and injection volume on total drug use for labor epidural analgesia: a randomized controlled trial. Anesth Analg 2011; 112: 904-11.CrossRef
7.
go back to reference Chua SM, Sia AT. Automated intermittent epidural boluses improve analgesia induced by intrathecal fentanyl during labour. Can J Anaesth 2004; 51: 581-5.CrossRef Chua SM, Sia AT. Automated intermittent epidural boluses improve analgesia induced by intrathecal fentanyl during labour. Can J Anaesth 2004; 51: 581-5.CrossRef
8.
go back to reference Lim Y, Sia AT, Ocampo C. Automated regular boluses for epidural analgesia: a comparison with continuous infusion. Int J Obstet Anesth 2005; 14: 305-9.CrossRef Lim Y, Sia AT, Ocampo C. Automated regular boluses for epidural analgesia: a comparison with continuous infusion. Int J Obstet Anesth 2005; 14: 305-9.CrossRef
9.
go back to reference George RB, Allen TK, Habib AS. Intermittent epidural bolus compared with continuous epidural infusions for labor analgesia: a systematic review and meta-analysis. Anesth Analg 2013; 116: 133-44.CrossRef George RB, Allen TK, Habib AS. Intermittent epidural bolus compared with continuous epidural infusions for labor analgesia: a systematic review and meta-analysis. Anesth Analg 2013; 116: 133-44.CrossRef
11.
go back to reference Carvalho B, George RB, Cobb B, McKenzie C, Riley ET. Implementation of programmed intermittent epidural bolus for the maintenance of labor analgesia. Anesth Analg 2016; 123: 965-71.CrossRef Carvalho B, George RB, Cobb B, McKenzie C, Riley ET. Implementation of programmed intermittent epidural bolus for the maintenance of labor analgesia. Anesth Analg 2016; 123: 965-71.CrossRef
12.
go back to reference Epsztein Kanczuk M, Barrett NM, Arzola C, Downey K, Ye XY, Carvalho JC. Programmed intermittent epidural bolus for labor analgesia during first stage of labor: a biased-coin up-and-down sequential allocation trial to determine the optimum interval time between boluses of a fixed volume of 10 mL of bupivacaine 0.0625% with fentanyl 2 μg/mL. Anesth Analg 2017; 124: 537-41.CrossRef Epsztein Kanczuk M, Barrett NM, Arzola C, Downey K, Ye XY, Carvalho JC. Programmed intermittent epidural bolus for labor analgesia during first stage of labor: a biased-coin up-and-down sequential allocation trial to determine the optimum interval time between boluses of a fixed volume of 10 mL of bupivacaine 0.0625% with fentanyl 2 μg/mL. Anesth Analg 2017; 124: 537-41.CrossRef
13.
go back to reference Zakus P, Arzola C, Bittencourt R, Downey K, Ye XY, Carvalho JC. Determination of the optimal programmed intermittent epidural bolus volume of bupivacaine 0.0625% with fentanyl 2 μg.ml-1 at a fixed interval of forty minutes: a biased coin up-and-down sequential allocation trial. Anaesthesia 2018; 73: 459-65.CrossRef Zakus P, Arzola C, Bittencourt R, Downey K, Ye XY, Carvalho JC. Determination of the optimal programmed intermittent epidural bolus volume of bupivacaine 0.0625% with fentanyl 2 μg.ml-1 at a fixed interval of forty minutes: a biased coin up-and-down sequential allocation trial. Anaesthesia 2018; 73: 459-65.CrossRef
14.
go back to reference Bittencourt R, Arzola C, Zakus P, Downey K, Ye XY, Carvalho JC. A biased coin up-and-down sequential allocation trial to determine the optimum programmed intermittent epidural bolus time interval between 5 mL boluses of bupivacaine 0.125% with fentanyl 2 µg·mL-1. Can J Anesth 2019; 66: 1075-81.CrossRef Bittencourt R, Arzola C, Zakus P, Downey K, Ye XY, Carvalho JC. A biased coin up-and-down sequential allocation trial to determine the optimum programmed intermittent epidural bolus time interval between 5 mL boluses of bupivacaine 0.125% with fentanyl 2 µg·mL-1. Can J Anesth 2019; 66: 1075-81.CrossRef
15.
go back to reference Hoyle J, Yentis SM. Assessing the height of block for caesarean section over the past three decades: trends from the literature. Anaesthesia 2015; 70: 421-8.CrossRef Hoyle J, Yentis SM. Assessing the height of block for caesarean section over the past three decades: trends from the literature. Anaesthesia 2015; 70: 421-8.CrossRef
16.
go back to reference Stylianou M, Flournoy N. Dose finding using bias the biased coin up-and-down design and isotonic regression. Biometrics 2002; 58: 171-7.CrossRef Stylianou M, Flournoy N. Dose finding using bias the biased coin up-and-down design and isotonic regression. Biometrics 2002; 58: 171-7.CrossRef
17.
go back to reference Armstrong JS. Forecasting by extrapolation: conclusions from twenty-five years of research. Interfaces 1984; 14: 52-66.CrossRef Armstrong JS. Forecasting by extrapolation: conclusions from twenty-five years of research. Interfaces 1984; 14: 52-66.CrossRef
18.
go back to reference Brezinski C, Redivo Zaglia M. Extrapolation Methods: Theory and Practice. North-Holland; 1991. Brezinski C, Redivo Zaglia M. Extrapolation Methods: Theory and Practice. North-Holland; 1991.
19.
go back to reference Pace NL, Stylianou MP. Advances in and limitations of up-and-down methodology: a précis of clinical use, study design, and dose estimation in anesthesia research. Anesthesiology 2007; 107: 144-52.CrossRef Pace NL, Stylianou MP. Advances in and limitations of up-and-down methodology: a précis of clinical use, study design, and dose estimation in anesthesia research. Anesthesiology 2007; 107: 144-52.CrossRef
20.
go back to reference Carvalho B, Riley ET. Programmed intermittent epidural boluses (PIEB) for maintenance of labor analgesia: an incremental step before the next paradigm shift? Turk J Anaesthesiol Reanim 2017; 45: 73-5.CrossRef Carvalho B, Riley ET. Programmed intermittent epidural boluses (PIEB) for maintenance of labor analgesia: an incremental step before the next paradigm shift? Turk J Anaesthesiol Reanim 2017; 45: 73-5.CrossRef
21.
go back to reference Ginosar Y, Davidson EM, Firman N, Meroz Y, Lemmens H, Weiniger CF. A randomized controlled trial using patient-controlled epidural analgesia with 0.25% versus 0.0625% bupivacaine in nulliparous labor: effect on analgesia requirement and maternal satisfaction. Int J Obstet Anesth 2010; 19: 171-8.CrossRef Ginosar Y, Davidson EM, Firman N, Meroz Y, Lemmens H, Weiniger CF. A randomized controlled trial using patient-controlled epidural analgesia with 0.25% versus 0.0625% bupivacaine in nulliparous labor: effect on analgesia requirement and maternal satisfaction. Int J Obstet Anesth 2010; 19: 171-8.CrossRef
22.
go back to reference Sultan P, Murphy C, Halpern S, Carvalho B. The effect of low concentrations versus high concentrations of local anesthetics for labour analgesia on obstetric and anesthetic outcomes: a meta-analysis. Can J Anesth 2013; 60: 840-54.CrossRef Sultan P, Murphy C, Halpern S, Carvalho B. The effect of low concentrations versus high concentrations of local anesthetics for labour analgesia on obstetric and anesthetic outcomes: a meta-analysis. Can J Anesth 2013; 60: 840-54.CrossRef
24.
go back to reference Hogan Q. Distribution of solution in the epidural space: examination by cryomicrotome section. Reg Anesth Pain Med 2002; 27: 150-6.PubMed Hogan Q. Distribution of solution in the epidural space: examination by cryomicrotome section. Reg Anesth Pain Med 2002; 27: 150-6.PubMed
26.
go back to reference Lange EM, Wong CA, Fitzgerald PC, et al. Effect of epidural infusion bolus delivery rate on the duration of labor analgesia: a randomized clinical trial. Anesthesiology 2018; 128: 745-53.CrossRef Lange EM, Wong CA, Fitzgerald PC, et al. Effect of epidural infusion bolus delivery rate on the duration of labor analgesia: a randomized clinical trial. Anesthesiology 2018; 128: 745-53.CrossRef
Metadata
Title
Programmed intermittent epidural bolus for labour analgesia during first stage of labour: a sequential allocation trial to determine the effective interval time between boluses of a fixed volume of 2.5 mL of bupivacaine 0.25% plus fentanyl 8 µg·mL−1
Authors
Daniel Shatalin, MD
Cristian Arzola, MD, MSc
Kristi Downey, MSc
Xiang Y. Ye, MSc
Jose C. A. Carvalho, MD, PhD
Publication date
01-05-2021
Publisher
Springer International Publishing
Keyword
Fentanyl
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Issue 5/2021
Print ISSN: 0832-610X
Electronic ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-021-01922-6

Other articles of this Issue 5/2021

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 5/2021 Go to the issue