Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 9/2012

Open Access 01-09-2012 | Reports of Original Investigations

Artifacts in research data obtained from an anesthesia information and management system

Authors: Nathalie P. Kool, MD, Judith A. R. van Waes, MD, Jilles B. Bijker, MD, Linda M. Peelen, PhD, Leo van Wolfswinkel, MD, PhD, Jurgen C. de Graaff, MD, PhD, Wilton A. van Klei, MD, PhD

Published in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Issue 9/2012

Login to get access

Abstract

Purpose

Artifacts in anesthesia information management system (AIMS) databases may influence research results. Filtering during data capturing can prevent artifacts from being stored. In this prospective study, we assessed the reliability of AIMS data by determining the incidence of artifactual values stored in the AIMS.

Methods

Vital parameter values regarding 86 surgical patients were collected in the AIMS both manually and automatically after filtering using the median value per minute. The percentage of artifactual values with a 95% confidence interval (CI) was calculated for each parameter. Secondary outcomes included the number of values that deviated from a predefined baseline, the percentage of these deviations that were caused by artifacts, the number of episodes across which these artifacts were distributed, and the most common causes of artifacts.

Results

Altogether, 9,534 min of anesthesia time were recorded. The overall percentages of artifacts were: 0.0 for heart rate (95% CI: 0.0 to 0.1), 0.3 for oxygen saturation (95% CI: 0.2 to 0.4), 4.7 for ST-segment (95% CI: 4.3 to 5.2), 2.3 for noninvasive blood pressure values (95% CI: 1.8 to 2.9), and 14 for invasive blood pressure values (95% CI: 12 to 15). Artifacts as a percentage of deviations from baseline were: 1.6 for heart rate (95% CI: 0.4 to 5.7), 24 for saturation (95% CI: 18 to 32), 83 for ST-segment (95% CI: 76 to 87), 3.3 for noninvasive blood pressure values (95% CI: 2.5 to 87), and 27 for invasive blood pressure values (95% CI: 24 to 31).

Conclusions

Storing a median value per minute to filter capturing of vital parameter values in an AIMS database provides reliable data for heart rate and oxygen saturation and acceptable reliability for noninvasive blood pressure data. Knowledge about the method of artifact filtering is essential in studies using AIMS data.
Literature
1.
go back to reference Allard J, Dzwonczyk R, Yablok D, Block FE Jr, McDonald JS. Effect of automatic record keeping on vigilance and record keeping time. Br J Anaesth 1995; 74: 619-26.PubMedCrossRef Allard J, Dzwonczyk R, Yablok D, Block FE Jr, McDonald JS. Effect of automatic record keeping on vigilance and record keeping time. Br J Anaesth 1995; 74: 619-26.PubMedCrossRef
2.
go back to reference Benson M, Junger A, Quinzio L, et al. Influence of the method of data collection on the documentation of blood-pressure readings with an anesthesia information management system (AIMS). Methods Inf Med 2001; 40: 190-5.PubMed Benson M, Junger A, Quinzio L, et al. Influence of the method of data collection on the documentation of blood-pressure readings with an anesthesia information management system (AIMS). Methods Inf Med 2001; 40: 190-5.PubMed
3.
go back to reference Eden A, Grach M, Goldik Z, et al. The implementation of an anaesthesia information management system. Eur J Anaesthesiol 2006; 23: 882-9.PubMedCrossRef Eden A, Grach M, Goldik Z, et al. The implementation of an anaesthesia information management system. Eur J Anaesthesiol 2006; 23: 882-9.PubMedCrossRef
4.
go back to reference Edsall DW, Deshane P, Giles C, Dick D, Sloan B, Farrow J. Computerized patient anesthesia records: less time and better quality than manually produced anesthesia records. J Clin Anesth 1993; 5: 275-83.PubMedCrossRef Edsall DW, Deshane P, Giles C, Dick D, Sloan B, Farrow J. Computerized patient anesthesia records: less time and better quality than manually produced anesthesia records. J Clin Anesth 1993; 5: 275-83.PubMedCrossRef
5.
go back to reference Reich DL, Wood RK Jr, Mattar R, et al. Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records. Anesth Analg 2000; 91: 612-6.PubMedCrossRef Reich DL, Wood RK Jr, Mattar R, et al. Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records. Anesth Analg 2000; 91: 612-6.PubMedCrossRef
6.
go back to reference Brenck F, Hartmann B, Katzer C, et al. Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system. J Clin Monit Comput 2009; 23: 85-92.PubMedCrossRef Brenck F, Hartmann B, Katzer C, et al. Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system. J Clin Monit Comput 2009; 23: 85-92.PubMedCrossRef
7.
go back to reference Lanier WL. Using database research to affect the science and art of medicine. Anesthesiology 2010; 113: 268-70.PubMedCrossRef Lanier WL. Using database research to affect the science and art of medicine. Anesthesiology 2010; 113: 268-70.PubMedCrossRef
8.
go back to reference Bijker JB, van Klei WA, Vergouwe Y, et al. Intraoperative hypotension and 1-year mortality after noncardiac surgery. Anesthesiology 2009; 111: 1217-26.PubMedCrossRef Bijker JB, van Klei WA, Vergouwe Y, et al. Intraoperative hypotension and 1-year mortality after noncardiac surgery. Anesthesiology 2009; 111: 1217-26.PubMedCrossRef
9.
go back to reference Broussard DM, Couch MC. Anesthesia preparation time is not affected by the experience level of the resident involved during his/her first month of adult cardiac surgery. J Cardiothorac Vasc Anesth 2011; 25: 766-9.PubMedCrossRef Broussard DM, Couch MC. Anesthesia preparation time is not affected by the experience level of the resident involved during his/her first month of adult cardiac surgery. J Cardiothorac Vasc Anesth 2011; 25: 766-9.PubMedCrossRef
10.
go back to reference Dexter F, Maguire D, Epstein RH. Observation study of anaesthetists’ fresh gas flow rates during anaesthesia with desflurane, isoflurane and sevoflurane. Anaesth Intensive Care 2011; 39: 460-4.PubMed Dexter F, Maguire D, Epstein RH. Observation study of anaesthetists’ fresh gas flow rates during anaesthesia with desflurane, isoflurane and sevoflurane. Anaesth Intensive Care 2011; 39: 460-4.PubMed
11.
go back to reference Ehrenfeld JM, Walsh JL, Sandberg WS. Right- and left-sided Mallinckrodt double-lumen tubes have identical clinical performance. Anesth Analg 2008; 106: 1847-52.PubMedCrossRef Ehrenfeld JM, Walsh JL, Sandberg WS. Right- and left-sided Mallinckrodt double-lumen tubes have identical clinical performance. Anesth Analg 2008; 106: 1847-52.PubMedCrossRef
12.
go back to reference Ehrenfeld JM, Epstein RH, Bader S, Kheterpal S, Sandberg WS. Automatic notifications mediated by anesthesia information management systems reduce the frequency of prolonged gaps in blood pressure documentation. Anesth Analg 2011; 113: 356-63.PubMedCrossRef Ehrenfeld JM, Epstein RH, Bader S, Kheterpal S, Sandberg WS. Automatic notifications mediated by anesthesia information management systems reduce the frequency of prolonged gaps in blood pressure documentation. Anesth Analg 2011; 113: 356-63.PubMedCrossRef
13.
go back to reference Bijker JB, van Klei WA, Kappen TH, van Wolfswinkel L, Moons KG, Kalkman CJ. Incidence of intraoperative hypotension as a function of the chosen definition: literature definitions applied to a retrospective cohort using automated data collection. Anesthesiology 2007; 107: 213-20.PubMedCrossRef Bijker JB, van Klei WA, Kappen TH, van Wolfswinkel L, Moons KG, Kalkman CJ. Incidence of intraoperative hypotension as a function of the chosen definition: literature definitions applied to a retrospective cohort using automated data collection. Anesthesiology 2007; 107: 213-20.PubMedCrossRef
14.
go back to reference Gostt RK, Rathbone GD, Tucker AP. Real-time pulse oximetry artifact annotation on computerized anaesthetic records. J Clin Monit Comput 2002; 17: 249-57.PubMedCrossRef Gostt RK, Rathbone GD, Tucker AP. Real-time pulse oximetry artifact annotation on computerized anaesthetic records. J Clin Monit Comput 2002; 17: 249-57.PubMedCrossRef
15.
go back to reference Takla G, Petre JH, Doyle DJ, Horibe M, Gopakumaran B. The problem of artifacts in patient monitor data during surgery: a clinical and methodological review. Anesth Analg 2006; 103: 1196-204.PubMedCrossRef Takla G, Petre JH, Doyle DJ, Horibe M, Gopakumaran B. The problem of artifacts in patient monitor data during surgery: a clinical and methodological review. Anesth Analg 2006; 103: 1196-204.PubMedCrossRef
16.
go back to reference Gorges M, Markewitz BA, Westenskow DR. Improving alarm performance in the medical intensive care unit using delays and clinical context. Anesth Analg 2009; 108: 1546-52.PubMedCrossRef Gorges M, Markewitz BA, Westenskow DR. Improving alarm performance in the medical intensive care unit using delays and clinical context. Anesth Analg 2009; 108: 1546-52.PubMedCrossRef
Metadata
Title
Artifacts in research data obtained from an anesthesia information and management system
Authors
Nathalie P. Kool, MD
Judith A. R. van Waes, MD
Jilles B. Bijker, MD
Linda M. Peelen, PhD
Leo van Wolfswinkel, MD, PhD
Jurgen C. de Graaff, MD, PhD
Wilton A. van Klei, MD, PhD
Publication date
01-09-2012
Publisher
Springer-Verlag
Published in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Issue 9/2012
Print ISSN: 0832-610X
Electronic ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-012-9754-0

Other articles of this Issue 9/2012

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 9/2012 Go to the issue