Skip to main content
Top
Published in: Indian Journal of Surgery 2/2015

01-12-2015 | Original Article

Comparison of Clinical Outcomes of Phalangeal Fracture Treated with Dorsolateral Approach or Post-middle Approach Using AO Mini Titanium Plate

Authors: Guang Li, Shen Liu, Guoting Chen, Zengchun Li, Yangzhou Liu, Guixin Sun, Qingyou Lu, Xia Li, Jun Tan, Ming Guan

Published in: Indian Journal of Surgery | Special Issue 2/2015

Login to get access

Abstract

The aim of this study is to investigate the clinical outcomes of various fixation methods for proximal phalangeal fractures with Arbeitsgemeinschaft für Osteosynthesefragen (AO) mini titanium plate by dorsolateral approach or post-middle approach. Clinical results of 62 fingers of 53 patients with proximal phalangeal fracture were evaluated. For dorsolateral approach, the lateral bundle of the extensor tendon was drawn away to expose the fracture part of the bone. After reduction, the plate was located at the dorsolateral side of the bone. For post-middle approach, the extensor tendon was split to expose the fracture part of the bone. After reduction, the plate was fixed to the proximal phalangeal side of the bone, and the extensor tendon was repaired with 3-0 nonabsorbable silk sutures. We found low overall complication rates in both groups. The mean total active motion (TAM) for the dorsolateral group and post-middle group was 234.60° ± 22.63° and 221.08° ± 25.69°, respectively. There was a statistical significance between the two groups (P = 0.037 < 0.05), indicating that TAM was notably affected by various fixation methods. With AO mini titanium plate, movement in dorsolateral approach group was significantly higher than in post-middle approach group. Dorsolateral approach is an acceptable technique of incision for proximal phalangeal fractures.
Literature
1.
go back to reference Emmett JE, Breck LW (1958) A review and analysis of 11, 000 fractures seen in a private practice of orthopaedic surgery, 1937–1956. J Bone Joint Surg Am 40:1169–1175PubMed Emmett JE, Breck LW (1958) A review and analysis of 11, 000 fractures seen in a private practice of orthopaedic surgery, 1937–1956. J Bone Joint Surg Am 40:1169–1175PubMed
2.
go back to reference Drenth DJ, Klasen HJ (1998) External fixation for phalangeal and metacarpal fractures. J Bone Joint Surg Br 80:227–230PubMedCrossRef Drenth DJ, Klasen HJ (1998) External fixation for phalangeal and metacarpal fractures. J Bone Joint Surg Br 80:227–230PubMedCrossRef
3.
go back to reference Barton N (1989) Conservative treatment of articular fractures in the hand. J Hand Surg Am 14:386–390PubMedCrossRef Barton N (1989) Conservative treatment of articular fractures in the hand. J Hand Surg Am 14:386–390PubMedCrossRef
4.
go back to reference Wright TA (1968) Early mobilization in fractures of the metacarpals and phalanges. Can J Surg 11:491–498PubMed Wright TA (1968) Early mobilization in fractures of the metacarpals and phalanges. Can J Surg 11:491–498PubMed
5.
go back to reference Kawamura K, Chung KC (2006) Fixation choices for closed simple unstable oblique phalangeal and metacarpal fractures. Hand Clin 22:287–295PubMedCrossRef Kawamura K, Chung KC (2006) Fixation choices for closed simple unstable oblique phalangeal and metacarpal fractures. Hand Clin 22:287–295PubMedCrossRef
6.
go back to reference Margic K (2006) External fixation of closed metacarpal and phalangeal fractures of digits. A prospective study of one hundred consecutive patients. J Hand Surg Br 31:30–40PubMedCrossRef Margic K (2006) External fixation of closed metacarpal and phalangeal fractures of digits. A prospective study of one hundred consecutive patients. J Hand Surg Br 31:30–40PubMedCrossRef
7.
go back to reference Safoury Y (2001) Treatment of phalangeal fractures by tension band wiring. J Hand Surg Br 26:50–52PubMedCrossRef Safoury Y (2001) Treatment of phalangeal fractures by tension band wiring. J Hand Surg Br 26:50–52PubMedCrossRef
8.
go back to reference Meunier MJ, Hentzen E, Ryan M, Shin AY, Lieber RL (2004) Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg Am 29:689–693PubMedCrossRef Meunier MJ, Hentzen E, Ryan M, Shin AY, Lieber RL (2004) Predicted effects of metacarpal shortening on interosseous muscle function. J Hand Surg Am 29:689–693PubMedCrossRef
9.
go back to reference Freeland AE, Orbay JL (2006) Extraarticular hand fractures in adults: a review of new developments. Clin Orthop Relat Res 445:133–145PubMed Freeland AE, Orbay JL (2006) Extraarticular hand fractures in adults: a review of new developments. Clin Orthop Relat Res 445:133–145PubMed
10.
go back to reference Souer JS, Mudgal CS (2008) Plate fixation in closed ipsilateral multiple metacarpal fractures. J Hand Surg Eur 33:740–744CrossRef Souer JS, Mudgal CS (2008) Plate fixation in closed ipsilateral multiple metacarpal fractures. J Hand Surg Eur 33:740–744CrossRef
11.
go back to reference Agarwal AK, Pickford MA (2006) Experience with a new ultralow-profile osteosynthesis system for fractures of the metacarpals and phalanges. Ann Plast Surg 57:206–212PubMedCrossRef Agarwal AK, Pickford MA (2006) Experience with a new ultralow-profile osteosynthesis system for fractures of the metacarpals and phalanges. Ann Plast Surg 57:206–212PubMedCrossRef
12.
go back to reference Pun WK, Chow SP, So YC, Luk KD, Ngai WK, Ip FK et al (1991) Unstable phalangeal fractures: treatment by A.O. screw and plate fixation. J Hand Surg Am 16:113–117PubMedCrossRef Pun WK, Chow SP, So YC, Luk KD, Ngai WK, Ip FK et al (1991) Unstable phalangeal fractures: treatment by A.O. screw and plate fixation. J Hand Surg Am 16:113–117PubMedCrossRef
13.
go back to reference Omokawa S, Fujitani R, Dohi Y, Okawa T, Yajima H (2008) Prospective outcomes of comminuted periarticular metacarpal and phalangeal fractures treated using a titanium plate system. J Hand Surg Am 33:857–863PubMedCrossRef Omokawa S, Fujitani R, Dohi Y, Okawa T, Yajima H (2008) Prospective outcomes of comminuted periarticular metacarpal and phalangeal fractures treated using a titanium plate system. J Hand Surg Am 33:857–863PubMedCrossRef
14.
go back to reference Wilson-Jones N, Laing H (2006) Acute injuries to the flexor and extensor tendons of the hand. Orthopaedic III: injuries to the upper limb. Surgery 24:441–445 Wilson-Jones N, Laing H (2006) Acute injuries to the flexor and extensor tendons of the hand. Orthopaedic III: injuries to the upper limb. Surgery 24:441–445
15.
go back to reference Soni A, Gulati A, Bassi JL, Singh D, Saini UC (2012) Outcome of closed ipsilateral metacarpal fractures treated with mini fragment plates and screws: a prospective study. J Orthop Traumatol 13:29–33PubMedPubMedCentralCrossRef Soni A, Gulati A, Bassi JL, Singh D, Saini UC (2012) Outcome of closed ipsilateral metacarpal fractures treated with mini fragment plates and screws: a prospective study. J Orthop Traumatol 13:29–33PubMedPubMedCentralCrossRef
16.
go back to reference Barton NJ (1984) Fractures of the hand. J Bone Joint Surg Br 66:159–167PubMed Barton NJ (1984) Fractures of the hand. J Bone Joint Surg Br 66:159–167PubMed
17.
go back to reference James JIP (1962) Fractures of the proximal and middle phalanges of the fingers. Acta Orthop Scand 32:401–412PubMedCrossRef James JIP (1962) Fractures of the proximal and middle phalanges of the fingers. Acta Orthop Scand 32:401–412PubMedCrossRef
18.
go back to reference Horton TC, Hatton M, Davis TR (2003) A prospective randomized controlled study of fixation of long oblique and spiral shaft fractures of the proximal phalanx: closed reduction and percutaneous Kirschen wiring versus open reduction and lag screw fixation. J Hand Surg Br 28:5–9PubMedCrossRef Horton TC, Hatton M, Davis TR (2003) A prospective randomized controlled study of fixation of long oblique and spiral shaft fractures of the proximal phalanx: closed reduction and percutaneous Kirschen wiring versus open reduction and lag screw fixation. J Hand Surg Br 28:5–9PubMedCrossRef
19.
go back to reference Greene TL, Noellert RC, Belsole RJ, Simpson LA (1989) Composite wiring of metacarpal and phalangeal fractures. J Hand Surg Am 14:665–669PubMedCrossRef Greene TL, Noellert RC, Belsole RJ, Simpson LA (1989) Composite wiring of metacarpal and phalangeal fractures. J Hand Surg Am 14:665–669PubMedCrossRef
20.
go back to reference Chen SH, Wei FC, Chen HC, Chuang CC, Noordhoff S (1994) Miniature plates and screws in acute complex hand injury. J Trauma 37:237–242PubMedCrossRef Chen SH, Wei FC, Chen HC, Chuang CC, Noordhoff S (1994) Miniature plates and screws in acute complex hand injury. J Trauma 37:237–242PubMedCrossRef
21.
go back to reference Trevisan C, Morganti A, Casiraghi A, Marinoni EC (2004) Low-severity metacarpal and phalangeal fractures treated with miniature plates and screws. Arch Orthop Trauma Surg 124:675–680PubMedCrossRef Trevisan C, Morganti A, Casiraghi A, Marinoni EC (2004) Low-severity metacarpal and phalangeal fractures treated with miniature plates and screws. Arch Orthop Trauma Surg 124:675–680PubMedCrossRef
22.
go back to reference Gupta R, Singh R, Siwach R, Sangwan S, Magu NK, Diwan R (2007) Evaluation of surgical stabilization of metacarpal and phalangeal fractures of hand. Indian J Orthop 41:224–229PubMedPubMedCentralCrossRef Gupta R, Singh R, Siwach R, Sangwan S, Magu NK, Diwan R (2007) Evaluation of surgical stabilization of metacarpal and phalangeal fractures of hand. Indian J Orthop 41:224–229PubMedPubMedCentralCrossRef
23.
go back to reference Zyluk A, Budzynski T (2006) Treatment of metacarpal and phalangeal fractures—a review. Chir Narzadow Ruchu Ortop Pol 71:299–308PubMed Zyluk A, Budzynski T (2006) Treatment of metacarpal and phalangeal fractures—a review. Chir Narzadow Ruchu Ortop Pol 71:299–308PubMed
24.
go back to reference Lu WW, Furumachi K, Ip WY, Chow SP (1996) Fixation for comminuted phalangeal fractures. A biomechanical study of five methods. J Hand Surg Br 21:765–767PubMedCrossRef Lu WW, Furumachi K, Ip WY, Chow SP (1996) Fixation for comminuted phalangeal fractures. A biomechanical study of five methods. J Hand Surg Br 21:765–767PubMedCrossRef
25.
go back to reference Galuppo LD, Stover SM, Willits NH (2000) A biomechanical comparison of double-plate and Y-plate fixation for comminuted equine second phalangeal fracture. Vet Surg 29:152–162PubMedCrossRef Galuppo LD, Stover SM, Willits NH (2000) A biomechanical comparison of double-plate and Y-plate fixation for comminuted equine second phalangeal fracture. Vet Surg 29:152–162PubMedCrossRef
Metadata
Title
Comparison of Clinical Outcomes of Phalangeal Fracture Treated with Dorsolateral Approach or Post-middle Approach Using AO Mini Titanium Plate
Authors
Guang Li
Shen Liu
Guoting Chen
Zengchun Li
Yangzhou Liu
Guixin Sun
Qingyou Lu
Xia Li
Jun Tan
Ming Guan
Publication date
01-12-2015
Publisher
Springer India
Published in
Indian Journal of Surgery / Issue Special Issue 2/2015
Print ISSN: 0972-2068
Electronic ISSN: 0973-9793
DOI
https://doi.org/10.1007/s12262-013-0968-3

Other articles of this Special Issue 2/2015

Indian Journal of Surgery 2/2015 Go to the issue