Dose verification of IMRT by use of a COMPASS transmission detector

Authors: Yuji Nakaguchi, Fujio Araki, Masato Maruyama, Shunji Saiga

Published in: Radiological Physics and Technology | Issue 1/2012

Login to get access

Abstract

Our purpose in this study was to evaluate the fundamental accuracy of reconstructed dose distributions from the COMPASS system using specific MLC test patterns and complicated IMRT neck plans. The COMPASS-reconstructed dose distributions were compared with those measured with EPID, MapCHECK, and EDR2 film and as well as Monte Carlo-calculated dose profiles with use of square-wave chart patterns of 20-, 10-, and 5-mm gaps and step and pyramid patterns. Additionally, the COMPASS dose distributions for clinical IMRT neck plans were tested. The COMPASS dose profiles were almost in agreement with the Monte Carlo-calculated dose profiles and point doses measured with MapCHECK for 20- and 10-mm gap patterns. The dose profile for a 5-mm gap pattern showed a narrow width due to the detector size in the penumbra region. For step and pyramid patterns, COMPASS agreed with MapCHECK and Monte Carlo calculation, except for EDR2 film. The COMPASS and MapCHECK dose distributions agreed with that of a treatment planning system by gamma analysis (criteria; 3 mm/3%). In comparisons of clinical IMRT neck dose distributions, COMPASS was measured with almost the same accuracy as MapCHECK, but slight deviations were found for large IMRT fields. These deviations could be minimized by improvement of the beam model of the COMPASS system. The COMPASS system can be expected to be used for traditional QA methods in clinical routine with the same accuracy as a MapCHECK diode detector.
Literature
1.
go back to reference Tsai JS, Wazer DE, Ling MN, Wu JK, Fagundes M, DiPetrillo T, Kramer B, Koistinen M, Engler MJ. Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. Int J Radiat Oncol Biol Phys. 1998;40:1213–30.PubMedCrossRef Tsai JS, Wazer DE, Ling MN, Wu JK, Fagundes M, DiPetrillo T, Kramer B, Koistinen M, Engler MJ. Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients. Int J Radiat Oncol Biol Phys. 1998;40:1213–30.PubMedCrossRef
2.
go back to reference Xing L, Curran B, Hill R, Holmes T, Ma L, Forster KM, Boyer AL. Dosimetric verification of a commercial inverse treatment planning system. Phys Med Biol. 1999;44:463–78.PubMedCrossRef Xing L, Curran B, Hill R, Holmes T, Ma L, Forster KM, Boyer AL. Dosimetric verification of a commercial inverse treatment planning system. Phys Med Biol. 1999;44:463–78.PubMedCrossRef
3.
go back to reference Zhu XR, Jursinic PA, Grimm DF, Lopez F, Rownd JJ, Gillin MT. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys. 2002;29:1687–92.PubMedCrossRef Zhu XR, Jursinic PA, Grimm DF, Lopez F, Rownd JJ, Gillin MT. Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator. Med Phys. 2002;29:1687–92.PubMedCrossRef
4.
go back to reference LoSasso T, Chui CS, Ling CC. Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Med Phys. 2001;28:2209–18.PubMedCrossRef LoSasso T, Chui CS, Ling CC. Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Med Phys. 2001;28:2209–18.PubMedCrossRef
5.
go back to reference Létourneau D, Gulam M, Yan D, Oldham M, Wong JW. Evaluation of a 2D diode array for IMRT quality assurance. Radiother Oncol. 2004;70:199–206.PubMedCrossRef Létourneau D, Gulam M, Yan D, Oldham M, Wong JW. Evaluation of a 2D diode array for IMRT quality assurance. Radiother Oncol. 2004;70:199–206.PubMedCrossRef
6.
go back to reference Jursinic PA, Nelms BE. A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med Phys. 2003;30:870–90.PubMedCrossRef Jursinic PA, Nelms BE. A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery. Med Phys. 2003;30:870–90.PubMedCrossRef
7.
go back to reference Greer PB, Vial P, Oliver L, Baldock C. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams. Med Phys. 2007;34:4389–98.PubMedCrossRef Greer PB, Vial P, Oliver L, Baldock C. Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams. Med Phys. 2007;34:4389–98.PubMedCrossRef
8.
go back to reference Arjomandy B, Sahoo N, Ding X, Gillin M. Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance. Med Phys. 2008;35:3889–94.PubMedCrossRef Arjomandy B, Sahoo N, Ding X, Gillin M. Use of a two-dimensional ionization chamber array for proton therapy beam quality assurance. Med Phys. 2008;35:3889–94.PubMedCrossRef
9.
go back to reference Masi L, Casamassima F, Doro R, Francescon P. Quality assurance of volumetric modulated arc therapy: evaluation and comparison of different dosimetric systems. Med Phys. 2011;38:612–21.PubMedCrossRef Masi L, Casamassima F, Doro R, Francescon P. Quality assurance of volumetric modulated arc therapy: evaluation and comparison of different dosimetric systems. Med Phys. 2011;38:612–21.PubMedCrossRef
10.
go back to reference Venkataraman S, Malkoske KE, Jensen M, Nakonechny KD, Asuni G, McCurdy BM. The influence of a novel transmission detector on 6 MV x-ray beam characteristics. Phys Med Biol. 2009;54:3173–83.PubMedCrossRef Venkataraman S, Malkoske KE, Jensen M, Nakonechny KD, Asuni G, McCurdy BM. The influence of a novel transmission detector on 6 MV x-ray beam characteristics. Phys Med Biol. 2009;54:3173–83.PubMedCrossRef
11.
go back to reference Boggula R, Lorenz F, Mueller L, Birkner M, Wertz H, Stieler F, Steil V, Lohr F, Wenz F. Experimental validation of a commercial 3D dose verification system for intensity-modulated arc therapies. Phys Med Biol. 2010;55:5619–33.PubMedCrossRef Boggula R, Lorenz F, Mueller L, Birkner M, Wertz H, Stieler F, Steil V, Lohr F, Wenz F. Experimental validation of a commercial 3D dose verification system for intensity-modulated arc therapies. Phys Med Biol. 2010;55:5619–33.PubMedCrossRef
12.
go back to reference Boggula R, Jahnke L, Wertz H, Lohr F, Wenz F. Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans. Int J Radiat Oncol Biol Phys (in press). Boggula R, Jahnke L, Wertz H, Lohr F, Wenz F. Patient-specific 3D pretreatment and potential 3D online dose verification of Monte Carlo-calculated IMRT prostate treatment plans. Int J Radiat Oncol Biol Phys (in press).
13.
go back to reference Kawrakow I, Rogers DWO. The EGSnrc code system: Monte Carlo simulation of electron and photon transport. National Research Council of Canada Report PIRS-701; 2009. Kawrakow I, Rogers DWO. The EGSnrc code system: Monte Carlo simulation of electron and photon transport. National Research Council of Canada Report PIRS-701; 2009.
14.
go back to reference Rogers DWO, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR. BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys. 1995;22:503–24.PubMedCrossRef Rogers DWO, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR. BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys. 1995;22:503–24.PubMedCrossRef
15.
go back to reference Roger DWO, Walters B, Kawrakow I. “BEAMnrc user’s manual,” National Research Council of Canada Report PIRS-0509 (a) Rev K; 2009. Roger DWO, Walters B, Kawrakow I. “BEAMnrc user’s manual,” National Research Council of Canada Report PIRS-0509 (a) Rev K; 2009.
16.
go back to reference Walters B, Kawrakow I, Rogers DW. DOSXYZnrc user’s manual. National Research Council of Canada Report PIRS-794revB; 2005. Walters B, Kawrakow I, Rogers DW. DOSXYZnrc user’s manual. National Research Council of Canada Report PIRS-794revB; 2005.
17.
go back to reference Palm A, Kirov AS, LoSasso T. Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose. Med Phys. 2004;31:3168–78.PubMedCrossRef Palm A, Kirov AS, LoSasso T. Predicting energy response of radiographic film in a 6 MV x-ray beam using Monte Carlo calculated fluence spectra and absorbed dose. Med Phys. 2004;31:3168–78.PubMedCrossRef
Metadata
Title
Dose verification of IMRT by use of a COMPASS transmission detector
Authors
Yuji Nakaguchi
Fujio Araki
Masato Maruyama
Shunji Saiga
Publication date
01-01-2012
Publisher
Springer Japan
Published in
Radiological Physics and Technology / Issue 1/2012
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-011-0137-y

Other articles of this Issue 1/2012

Radiological Physics and Technology 1/2012 Go to the issue