Skip to main content
Top
Published in: Radiological Physics and Technology 2/2008

01-07-2008

Evaluation of the spatial resolution of multiplanar reconstruction images

Authors: Shohei Kudomi, Katsuhiko Ueda, Yasuyuki Ueda, Masateru Kawakubo, Taizo Sanada

Published in: Radiological Physics and Technology | Issue 2/2008

Login to get access

Abstract

We present a simple method for evaluating the spatial resolution of multi-slice computed tomography (MSCT) multiplanar reconstruction images (MPRs). We scanned a bead phantom to obtain the three-dimensional point spread function (PSF), and bead-centric MPRs were generated. The modulation transfer function (MTF) was calculated from the MPRs via a two-dimensional Fourier transform (2DFFT) of the PSF. The results showed that, when MPRs were reconstructed using axial images less than or equal to a nominal 1.0-mm slice-width with a standard kernel for the abdomen, the MTF in the longitudinal direction (z-direction) was superior to that in the in-plane (x–y plane) direction. It was also found that the arbitrary-angle MTFs of MPRs were between the MTFs of the in-plane and longitudinal directions. It was confirmed that this method can be used to evaluate MPR spatial resolution.
Literature
1.
go back to reference Ferencik M, Ropers D, Abbara S, Cury RC, Hoffmann U, Nieman K, et al. Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using multidetector CT. Radiology. 2007;243:696–702.CrossRefPubMed Ferencik M, Ropers D, Abbara S, Cury RC, Hoffmann U, Nieman K, et al. Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using multidetector CT. Radiology. 2007;243:696–702.CrossRefPubMed
2.
go back to reference Karaman B, Koplay M, Ozturk E, Basekim CC, Ogul H, Mutlu H, et al. Retroaortic left renal vein: multidetector computed tomography angiography findings and its clinical importance. Acta Radiol. 2007;48:355–60.CrossRefPubMed Karaman B, Koplay M, Ozturk E, Basekim CC, Ogul H, Mutlu H, et al. Retroaortic left renal vein: multidetector computed tomography angiography findings and its clinical importance. Acta Radiol. 2007;48:355–60.CrossRefPubMed
3.
go back to reference Chen CY, Hsu JS, Wu DC, Kang WY, Hsieh JS, Jaw TS, et al. Gastric cancer: preoperative local staging with 3D multi-detector row CT-correlation with surgical and histopathologic results. Radiology. 2007;242:472–82.CrossRefPubMed Chen CY, Hsu JS, Wu DC, Kang WY, Hsieh JS, Jaw TS, et al. Gastric cancer: preoperative local staging with 3D multi-detector row CT-correlation with surgical and histopathologic results. Radiology. 2007;242:472–82.CrossRefPubMed
4.
go back to reference Goodsitt MM, Chan HP, Way TW, Larson SC, Christodoulou EG, Kim J. Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners. Med Phys. 2006;33:3006–17.CrossRefPubMedPubMedCentral Goodsitt MM, Chan HP, Way TW, Larson SC, Christodoulou EG, Kim J. Accuracy of the CT numbers of simulated lung nodules imaged with multi-detector CT scanners. Med Phys. 2006;33:3006–17.CrossRefPubMedPubMedCentral
5.
go back to reference Kirwin SL, Langmack KA. Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom. Phys Med Biol. 2005;50:N251–5.CrossRefPubMed Kirwin SL, Langmack KA. Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom. Phys Med Biol. 2005;50:N251–5.CrossRefPubMed
6.
go back to reference Ziegler A, Kohler T, Proksa R. Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. Med Phys. 2007;34:585–98.CrossRefPubMed Ziegler A, Kohler T, Proksa R. Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. Med Phys. 2007;34:585–98.CrossRefPubMed
7.
go back to reference Hara T, Kato H, Akiyama M, Murata K. Basic examination of in-plane spatial resolution in multi-slice CT (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zasshi. 2002;58:473–8. Hara T, Kato H, Akiyama M, Murata K. Basic examination of in-plane spatial resolution in multi-slice CT (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zasshi. 2002;58:473–8.
8.
go back to reference Yamamoto S, Jokoh T, Matsumoto T, Nakanishi S, Ogata Y, Naito H. Evaluation of physical characteristics in multi-slice CT (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zassi. 2008;56:1447–53. Yamamoto S, Jokoh T, Matsumoto T, Nakanishi S, Ogata Y, Naito H. Evaluation of physical characteristics in multi-slice CT (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zassi. 2008;56:1447–53.
9.
go back to reference Polacin A, Kalender WA, Brink J, Vannier MA. Measurement of slice sensitivity profiles in spiral CT. Med Phys. 1994;21:133–40.CrossRefPubMed Polacin A, Kalender WA, Brink J, Vannier MA. Measurement of slice sensitivity profiles in spiral CT. Med Phys. 1994;21:133–40.CrossRefPubMed
10.
go back to reference Hara T, Tsuzaka M, Sakurai N. Measurement of modulation transfer function in Z-axis for multi-slice spiral CT using the micro-disk method: comparison with the bead method and examination of geometric influence (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zasshi. 2003;59:1391–8. Hara T, Tsuzaka M, Sakurai N. Measurement of modulation transfer function in Z-axis for multi-slice spiral CT using the micro-disk method: comparison with the bead method and examination of geometric influence (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zasshi. 2003;59:1391–8.
11.
go back to reference Tukagoshi S, Ota T, Fujii M, Kazama M, Okumura M, Johkoh T. Improvement of spatial resolution in the longitudinal direction for isotropic imaging in herical CT. Phys Med Biol. 2007;52:791–801.CrossRef Tukagoshi S, Ota T, Fujii M, Kazama M, Okumura M, Johkoh T. Improvement of spatial resolution in the longitudinal direction for isotropic imaging in herical CT. Phys Med Biol. 2007;52:791–801.CrossRef
12.
go back to reference Kimura M, Usui J, Nozawa T. Evaluation of the power of different angles in MPR images of 16DAS-MDCT (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zassi. 2007;63:319–25. CrossRef Kimura M, Usui J, Nozawa T. Evaluation of the power of different angles in MPR images of 16DAS-MDCT (in Japanese). Nippon Hoshasen Gijutsu Gakkai Zassi. 2007;63:319–25. CrossRef
Metadata
Title
Evaluation of the spatial resolution of multiplanar reconstruction images
Authors
Shohei Kudomi
Katsuhiko Ueda
Yasuyuki Ueda
Masateru Kawakubo
Taizo Sanada
Publication date
01-07-2008
Publisher
Springer Japan
Published in
Radiological Physics and Technology / Issue 2/2008
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-008-0033-2

Other articles of this Issue 2/2008

Radiological Physics and Technology 2/2008 Go to the issue