Skip to main content
Top
Published in: Neurocritical Care 3/2011

01-12-2011 | Take Notice Technology

Optic Nerve Ultrasound for the Detection of Raised Intracranial Pressure

Authors: Venkatakrishna Rajajee, Monique Vanaman, Jeffrey James Fletcher, Teresa Lee Jacobs

Published in: Neurocritical Care | Issue 3/2011

Login to get access

Abstract

Background

Optic nerve ultrasonography (ONUS) may help identify raised intracranial pressure (ICP). The optimal optic nerve sheath diameter (ONSD) cut-off for the identification of intracranial hypertension has not been established, with some clinical studies suggesting a higher cut-off than may be expected on the basis of prior laboratory investigation.

Objective

To validate ONUS performed by neurointensivists as a technique for the detection of intracranial hypertension and identify the optimal ONSD criterion for the detection of ICP > 20 mmHg.

Methods

Prospective blinded observational study. Patients in the ICU with either external ventricular drains or intraparenchymal ICP monitors at risk for intracranial hypertension were enrolled. The ONSD was measured by neurointensivists at the bedside with simultaneous invasive ICP measurement. An ROC curve was constructed to determine the optimal ONSD for the detection of ICP >  20 mmHg.

Measurements and Results

A total of 536 ONSD measurements were performed on 65 patients. Diagnoses included subarachnoid hemorrhage, traumatic brain injury, intracerebral hemorrhage, ischemic stroke and brain tumor. ROC curve analysis revealed area under the curve (AUC) = 0.98 (95% CI 0.96–0.99; P < 0.0001 for AUC = 0.5). Optimal ONSD for detection of ICP > 20 mmHg was ≥0.48 cm sensitivity 96% (95% CI 91–99%); specificity 94% (92–96%). Sensitivity of the higher cutoff of ≥0.52 cm proposed by some authors was only 67% (58–75%), with specificity 98% (97–99%).

Conclusions

Bedside ONSD measurement, performed by neurointensivists, is an accurate, non-invasive method to identify ICP > 20 mmHg in a heterogeneous group of patients with acute brain injury. ONSD ≥0.48 cm has the greatest accuracy, however, internal validation of ONSD criteria may be required.
Literature
1.
go back to reference Brain Trauma Foundation, American Association of Neurological Surgeons, Congress of Neurological Surgeons, Joint Section on Neurotrauma, Critical Care, AANS/CNS. Guidelines for the management of severe traumatic brain injury. VI. Indications for intracranial pressure monitoring. J Neurotrauma. 2007;24(Suppl 1):S37–44. Brain Trauma Foundation, American Association of Neurological Surgeons, Congress of Neurological Surgeons, Joint Section on Neurotrauma, Critical Care, AANS/CNS. Guidelines for the management of severe traumatic brain injury. VI. Indications for intracranial pressure monitoring. J Neurotrauma. 2007;24(Suppl 1):S37–44.
2.
go back to reference Morgenstern LB, Hemphill JC III, Anderson C, Becker K, Broderick JP, Connolly ES Jr, Greenberg SM, Huang JN, MacDonald RL, Messé SR, Mitchell PH, Selim M, Tamargo RJ, American Heart Association Stroke Council and Council on Cardiovascular Nursing. Guidelines for the management of spontaneous intracerebral hemorrhage: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke. 2010;41(9):2108–29.PubMedCrossRef Morgenstern LB, Hemphill JC III, Anderson C, Becker K, Broderick JP, Connolly ES Jr, Greenberg SM, Huang JN, MacDonald RL, Messé SR, Mitchell PH, Selim M, Tamargo RJ, American Heart Association Stroke Council and Council on Cardiovascular Nursing. Guidelines for the management of spontaneous intracerebral hemorrhage: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke. 2010;41(9):2108–29.PubMedCrossRef
3.
go back to reference Ngo QN, Ranger A, Singh RN, Kornecki A, Seabrook JA, Fraser DD. External ventricular drains in pediatric patients. Pediatr Crit Care Med. 2009;10(3):346–51.PubMedCrossRef Ngo QN, Ranger A, Singh RN, Kornecki A, Seabrook JA, Fraser DD. External ventricular drains in pediatric patients. Pediatr Crit Care Med. 2009;10(3):346–51.PubMedCrossRef
4.
go back to reference Ross IB, Dhillon GS. Ventriculostomy-related cerebral hemorrhages after endovascular aneurysm treatment. AJNR Am J Neuroradiol. 2003;24(8):1528–31.PubMed Ross IB, Dhillon GS. Ventriculostomy-related cerebral hemorrhages after endovascular aneurysm treatment. AJNR Am J Neuroradiol. 2003;24(8):1528–31.PubMed
5.
go back to reference Hayreh SS. Pathogenesis of oedema of the optic disk (papilloedema), a preliminary report. Br J Ophthal. 1964;48:522–43.CrossRef Hayreh SS. Pathogenesis of oedema of the optic disk (papilloedema), a preliminary report. Br J Ophthal. 1964;48:522–43.CrossRef
6.
go back to reference Hansen HC, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34–40.PubMedCrossRef Hansen HC, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34–40.PubMedCrossRef
7.
go back to reference Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol. 1996;26(10):701–5.PubMedCrossRef Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol. 1996;26(10):701–5.PubMedCrossRef
8.
go back to reference Geeraerts T, Launey Y, Martin L, Pottecher J, Vigué B, Duranteau J, Benhamou D. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med. 2007;33(10):1704–11.PubMedCrossRef Geeraerts T, Launey Y, Martin L, Pottecher J, Vigué B, Duranteau J, Benhamou D. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med. 2007;33(10):1704–11.PubMedCrossRef
9.
go back to reference Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008;15(2):201–4.PubMedCrossRef Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008;15(2):201–4.PubMedCrossRef
10.
go back to reference Soldatos T, Karakitsos D, Chatzimichail K, Papathanasiou M, Gouliamos A, Karabinis A. Optic nerve sonography in the diagnostic evaluation of adult brain injury. Crit Care. 2008;12(3):R67.PubMedCrossRef Soldatos T, Karakitsos D, Chatzimichail K, Papathanasiou M, Gouliamos A, Karabinis A. Optic nerve sonography in the diagnostic evaluation of adult brain injury. Crit Care. 2008;12(3):R67.PubMedCrossRef
11.
go back to reference Geeraerts T, Merceron S, Benhamou D, Vigué B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med. 2008;34(11):2062–7.PubMedCrossRef Geeraerts T, Merceron S, Benhamou D, Vigué B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med. 2008;34(11):2062–7.PubMedCrossRef
12.
go back to reference Moretti R, Pizzi B. Optic nerve ultrasound for detection of intracranial hypertension in intracranial hemorrhage patients: confirmation of previous findings in a different patient population. J Neurosurg Anesthesiol. 2009;21(1):16–20.PubMedCrossRef Moretti R, Pizzi B. Optic nerve ultrasound for detection of intracranial hypertension in intracranial hemorrhage patients: confirmation of previous findings in a different patient population. J Neurosurg Anesthesiol. 2009;21(1):16–20.PubMedCrossRef
13.
go back to reference Moretti R, Pizzi B, Cassini F, Vivaldi N. Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care. 2009;11:406–10.PubMedCrossRef Moretti R, Pizzi B, Cassini F, Vivaldi N. Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care. 2009;11:406–10.PubMedCrossRef
14.
go back to reference Eisenberg HM, Gary HE Jr, Aldrich EF, Saydjari C, Turner B, Foulkes MA, Jane JA, Marmarou A, Marshall LF, Young HF. Initial CT findings in 753 patients with severe head injury. A report from the NIH Traumatic Coma Data Bank. J Neurosurg. 1990;73(5):688–98.PubMedCrossRef Eisenberg HM, Gary HE Jr, Aldrich EF, Saydjari C, Turner B, Foulkes MA, Jane JA, Marmarou A, Marshall LF, Young HF. Initial CT findings in 753 patients with severe head injury. A report from the NIH Traumatic Coma Data Bank. J Neurosurg. 1990;73(5):688–98.PubMedCrossRef
15.
go back to reference Miller MT, Pasquale M, Kurek S, White J, Martin P, Bannon K, Wasser T, Li M. Initial head computed tomographic scan characteristics have a linear relationship with initial intracranial pressure after trauma. J Trauma. 2004;56(5):967–72. (discussion 972–973).PubMedCrossRef Miller MT, Pasquale M, Kurek S, White J, Martin P, Bannon K, Wasser T, Li M. Initial head computed tomographic scan characteristics have a linear relationship with initial intracranial pressure after trauma. J Trauma. 2004;56(5):967–72. (discussion 972–973).PubMedCrossRef
17.
go back to reference Rajajee V, Thyagarajan P, Rajagopalan RE. Optic nerve ultrasonography for detection of raised intracranial pressure when invasive monitoring is unavailable. Neurol India. 2010;58(5):812–3.PubMedCrossRef Rajajee V, Thyagarajan P, Rajagopalan RE. Optic nerve ultrasonography for detection of raised intracranial pressure when invasive monitoring is unavailable. Neurol India. 2010;58(5):812–3.PubMedCrossRef
18.
go back to reference Strumwasser A, Kwan RO, Yeung L, Miraflor E, Ereso A, Castro-Moure F, Patel A, Sadjadi J, Victorino GP. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma. J Surg Res. 2011. doi:10.1016/j.jss.2011.03.009. Strumwasser A, Kwan RO, Yeung L, Miraflor E, Ereso A, Castro-Moure F, Patel A, Sadjadi J, Victorino GP. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma. J Surg Res. 2011. doi:10.​1016/​j.​jss.​2011.​03.​009.
19.
go back to reference Craig DGN, Van der Most RN, Hayes PC, Lee A. Transorbital sonographic evaluation of optic nerve sheath diameter in acute liver failure. J Hepatol. 2010;52(Suppl 1):S321.CrossRef Craig DGN, Van der Most RN, Hayes PC, Lee A. Transorbital sonographic evaluation of optic nerve sheath diameter in acute liver failure. J Hepatol. 2010;52(Suppl 1):S321.CrossRef
20.
go back to reference Jang TB, Casey RJ, Dyne P, Kaji A. The learning curve of resident physicians using emergency ultrasonography for obstructive uropathy. Acad Emerg Med. 2010;17(9):1024–7.PubMedCrossRef Jang TB, Casey RJ, Dyne P, Kaji A. The learning curve of resident physicians using emergency ultrasonography for obstructive uropathy. Acad Emerg Med. 2010;17(9):1024–7.PubMedCrossRef
21.
go back to reference Grant EG, Benson CB, Moneta GL, Alexandrov AV, Baker JD, Bluth EI, Carroll BA, Eliasziw M, Gocke J, Hertzberg BS, Katanick S, Needleman L, Pellerito J, Polak JF, Rholl KS, Wooster DL, Zierler RE. Carotid artery stenosis: gray-scale and Doppler US diagnosis—Society of Radiologists in Ultrasound Consensus Conference. Radiology. 2003;229(2):340–6.PubMedCrossRef Grant EG, Benson CB, Moneta GL, Alexandrov AV, Baker JD, Bluth EI, Carroll BA, Eliasziw M, Gocke J, Hertzberg BS, Katanick S, Needleman L, Pellerito J, Polak JF, Rholl KS, Wooster DL, Zierler RE. Carotid artery stenosis: gray-scale and Doppler US diagnosis—Society of Radiologists in Ultrasound Consensus Conference. Radiology. 2003;229(2):340–6.PubMedCrossRef
22.
23.
go back to reference Copetti R, Cattarossi L. Optic nerve ultrasound: artifacts and real images. Intensive Care Med. 2009;35(8):1488–9. (author reply 1490–1491).PubMedCrossRef Copetti R, Cattarossi L. Optic nerve ultrasound: artifacts and real images. Intensive Care Med. 2009;35(8):1488–9. (author reply 1490–1491).PubMedCrossRef
Metadata
Title
Optic Nerve Ultrasound for the Detection of Raised Intracranial Pressure
Authors
Venkatakrishna Rajajee
Monique Vanaman
Jeffrey James Fletcher
Teresa Lee Jacobs
Publication date
01-12-2011
Publisher
Humana Press Inc
Published in
Neurocritical Care / Issue 3/2011
Print ISSN: 1541-6933
Electronic ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-011-9606-8

Other articles of this Issue 3/2011

Neurocritical Care 3/2011 Go to the issue