Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 5/2011

01-05-2011 | Emerging Ideas

Emerging Ideas: Soft Tissue Applications of Radiostereometric Analysis

Authors: Lucian B. Solomon, MD, PhD, FRACS, Stuart A. Callary, BAppSc

Published in: Clinical Orthopaedics and Related Research® | Issue 5/2011

Login to get access

Abstract

Background

Currently, the movement that occurs at the site of soft tissue repair cannot be measured accurately in vivo. Radiostereometric analysis (RSA) is the gold standard for measuring movement between two skeletal segments in vivo but its application to studying soft tissue migration has been limited by the unknown stability of tantalum beads in tendons and ligaments and their ability to define rigid bodies in these structures.

Hypothesis

RSA can be used to accurately measure movement between two tendon segments or between a bony and a tendon segment in vivo.

Methods of Study

The stability of tantalum beads and the ability to use such beads to define rigid bodies in some soft tissues will be investigated in animal models of tendon repair. Several tantalum bead insertion techniques will be tested using in vivo RSA measurements of bead movement followed by morphologic studies of the repaired tendon and soft tissue reaction to the tantalum beads.

Significance

RSA performed on tantalum beads encapsulated in muscles and tendons could be a powerful new tool to study the in vivo motion at the site of soft tissue repairs, for instance, the tendon gap formation. If RSA could be used to evaluate the efficiency of different tendon repair techniques in vivo, enhanced rehabilitation protocols could be developed and complications associated with prolonged protection or failure of repair could be reduced.
Literature
1.
go back to reference Adam F, Pape D, Schiel K, Steimer O, Kohn D, Rupp S. Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis. Am J Sports Med. 2004;32:71–78.PubMedCrossRef Adam F, Pape D, Schiel K, Steimer O, Kohn D, Rupp S. Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis. Am J Sports Med. 2004;32:71–78.PubMedCrossRef
2.
go back to reference Alberius P. Bone reactions to tantalum markers: a scanning electron microscopic study. Acta Anat. 1983;115:310–318.PubMedCrossRef Alberius P. Bone reactions to tantalum markers: a scanning electron microscopic study. Acta Anat. 1983;115:310–318.PubMedCrossRef
3.
go back to reference Arai Y, Hara K, Takahashi T, Urade H, Minami G, Takamiya H, Kubo T. Evaluation of the vascular status of autogenous hamstring tendon grafts after anterior cruciate ligament reconstruction in humans using magnetic resonance angiography. Knee Surg Sports Traumatol Arthrosc. 2008;16:342–347.PubMedCrossRef Arai Y, Hara K, Takahashi T, Urade H, Minami G, Takamiya H, Kubo T. Evaluation of the vascular status of autogenous hamstring tendon grafts after anterior cruciate ligament reconstruction in humans using magnetic resonance angiography. Knee Surg Sports Traumatol Arthrosc. 2008;16:342–347.PubMedCrossRef
4.
go back to reference Aronson AS, Jonsson N, Alberius P. Tantalum markers in radiography: an assessment of tissue reactions. Skeletal Radiol. 1985;14:207–211.PubMedCrossRef Aronson AS, Jonsson N, Alberius P. Tantalum markers in radiography: an assessment of tissue reactions. Skeletal Radiol. 1985;14:207–211.PubMedCrossRef
5.
go back to reference Bragdon CR, Malchau H, Yuan X, Perinchief R, Karrholm J, Borlin N, Estok DM, Harris WH. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. J Orthop Res. 2002;20:688–695.PubMedCrossRef Bragdon CR, Malchau H, Yuan X, Perinchief R, Karrholm J, Borlin N, Estok DM, Harris WH. Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model. J Orthop Res. 2002;20:688–695.PubMedCrossRef
6.
go back to reference Cashman PM, Baring T, Reilly P, Emery RJ, Amis AA. Measurement of migration of soft tissue by modified Roentgen stereophotogrammetric analysis (RSA): validation of a new technique to monitor rotator cuff tears. J Med Eng Technol. 2010;34:159–165.PubMedCrossRef Cashman PM, Baring T, Reilly P, Emery RJ, Amis AA. Measurement of migration of soft tissue by modified Roentgen stereophotogrammetric analysis (RSA): validation of a new technique to monitor rotator cuff tears. J Med Eng Technol. 2010;34:159–165.PubMedCrossRef
7.
go back to reference Chehade MJ, Solomon LB, Callary SA, Benveniste SH, Pohl AP, Howie DW. Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study. Clin Orthop Relat Res. 2009;467:1839–1847.PubMedCrossRef Chehade MJ, Solomon LB, Callary SA, Benveniste SH, Pohl AP, Howie DW. Differentially loaded radiostereometric analysis to monitor fracture stiffness: a feasibility study. Clin Orthop Relat Res. 2009;467:1839–1847.PubMedCrossRef
8.
go back to reference Downing MR, Ashcroft PB, Johnstone AJ, Bach O, Mackenzie S, Ashcroft GP. Assessment of inducible fracture micromotion in distal radial fractures using radiostereometry. J Orthop Trauma. 2008;22(suppl):S96–S105.PubMedCrossRef Downing MR, Ashcroft PB, Johnstone AJ, Bach O, Mackenzie S, Ashcroft GP. Assessment of inducible fracture micromotion in distal radial fractures using radiostereometry. J Orthop Trauma. 2008;22(suppl):S96–S105.PubMedCrossRef
9.
go back to reference Festa A, Mulieri PJ, Newman JS, Spitz DJ, Leslie BM. Effectiveness of magnetic resonance imaging in detecting partial and complete distal biceps tendon rupture. J Hand Surg Am. 2010;35:77–83.PubMedCrossRef Festa A, Mulieri PJ, Newman JS, Spitz DJ, Leslie BM. Effectiveness of magnetic resonance imaging in detecting partial and complete distal biceps tendon rupture. J Hand Surg Am. 2010;35:77–83.PubMedCrossRef
10.
go back to reference Friden T, Ryd L, Lindstrand A. Laxity and graft fixation after reconstruction of the anterior cruciate ligament: a roentgen stereophotogrammetric analysis of 11 patients. Acta Orthop Scand. 1992;63:80–84.PubMedCrossRef Friden T, Ryd L, Lindstrand A. Laxity and graft fixation after reconstruction of the anterior cruciate ligament: a roentgen stereophotogrammetric analysis of 11 patients. Acta Orthop Scand. 1992;63:80–84.PubMedCrossRef
11.
go back to reference Haut Donahue TL, Howell SM, Hull ML, Gregersen C. A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts. Arthroscopy. 2002;18:589–597.PubMedCrossRef Haut Donahue TL, Howell SM, Hull ML, Gregersen C. A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts. Arthroscopy. 2002;18:589–597.PubMedCrossRef
12.
go back to reference Jorn LP, Friden T, Ryd L, Lindstrand A. Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis. J Bone Joint Surg Br. 1998;80:169–172.PubMedCrossRef Jorn LP, Friden T, Ryd L, Lindstrand A. Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis. J Bone Joint Surg Br. 1998;80:169–172.PubMedCrossRef
13.
go back to reference Karrholm J. Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand. 1989;60:491–503.CrossRef Karrholm J. Roentgen stereophotogrammetry. Review of orthopedic applications. Acta Orthop Scand. 1989;60:491–503.CrossRef
14.
go back to reference Karrholm J, Gill RH, Valstar ER. The history and future of radiostereometric analysis. Clin Orthop Relat Res. 2006;448:10–21.PubMedCrossRef Karrholm J, Gill RH, Valstar ER. The history and future of radiostereometric analysis. Clin Orthop Relat Res. 2006;448:10–21.PubMedCrossRef
15.
go back to reference Karrholm J, Selvik G, Elmqvist LG, Hansson LI. Active knee motion after cruciate ligament rupture: stereoradiography. Acta Orthop Scand. 1988;59:158–164.PubMed Karrholm J, Selvik G, Elmqvist LG, Hansson LI. Active knee motion after cruciate ligament rupture: stereoradiography. Acta Orthop Scand. 1988;59:158–164.PubMed
16.
go back to reference Karrholm J, Selvik G, Elmqvist LG, Hansson LI, Jonsson H. Three-dimensional instability of the anterior cruciate deficient knee. J Bone Joint Surg Br. 1988;70:777–783.PubMed Karrholm J, Selvik G, Elmqvist LG, Hansson LI, Jonsson H. Three-dimensional instability of the anterior cruciate deficient knee. J Bone Joint Surg Br. 1988;70:777–783.PubMed
17.
go back to reference Khan R, Konyves A, Rama KR, Thomas R, Amis AA. RSA can measure ACL graft stretching and migration: development of a new method. Clin Orthop Relat Res. 2006;448:139–145.PubMedCrossRef Khan R, Konyves A, Rama KR, Thomas R, Amis AA. RSA can measure ACL graft stretching and migration: development of a new method. Clin Orthop Relat Res. 2006;448:139–145.PubMedCrossRef
18.
go back to reference Khan RJ, Yao F, Li M, Nivbrant B, Wood D. Capsular-enhanced repair of the short external rotators after total hip arthroplasty. J Arthroplasty. 2007;22:840–843.PubMedCrossRef Khan RJ, Yao F, Li M, Nivbrant B, Wood D. Capsular-enhanced repair of the short external rotators after total hip arthroplasty. J Arthroplasty. 2007;22:840–843.PubMedCrossRef
19.
go back to reference Madanat R, Moritz N, Larsson S, Aro HT. RSA applications in monitoring of fracture healing in clinical trials. Scand J Surg. 2006;95:119–127.PubMed Madanat R, Moritz N, Larsson S, Aro HT. RSA applications in monitoring of fracture healing in clinical trials. Scand J Surg. 2006;95:119–127.PubMed
20.
go back to reference O’Driscoll SW, Goncalves LB, Dietz P. The hook test for distal biceps tendon avulsion. Am J Sports Med. 2007;35:1865–1869.PubMedCrossRef O’Driscoll SW, Goncalves LB, Dietz P. The hook test for distal biceps tendon avulsion. Am J Sports Med. 2007;35:1865–1869.PubMedCrossRef
21.
go back to reference Roos PJ, Hull ML, Howell SM. How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: a study using roentgen stereophotogrammetric analysis (RSA). J Biomech Eng. 2004;126:62–69.PubMedCrossRef Roos PJ, Hull ML, Howell SM. How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: a study using roentgen stereophotogrammetric analysis (RSA). J Biomech Eng. 2004;126:62–69.PubMedCrossRef
22.
go back to reference Sckell A, Leunig M, Fraitzl CR, Ganz R, Ballmer FT. The connective-tissue envelope in revascularisation of patellar tendon grafts. J Bone Joint Surg Br. 1999;81:915–920.PubMedCrossRef Sckell A, Leunig M, Fraitzl CR, Ganz R, Ballmer FT. The connective-tissue envelope in revascularisation of patellar tendon grafts. J Bone Joint Surg Br. 1999;81:915–920.PubMedCrossRef
23.
go back to reference Selvik G. Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989;232:1–51.PubMed Selvik G. Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989;232:1–51.PubMed
24.
go back to reference Smith CK, Hull ML, Howell SM. Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA). J Biomech Eng. 2005;127:887–890.PubMedCrossRef Smith CK, Hull ML, Howell SM. Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA). J Biomech Eng. 2005;127:887–890.PubMedCrossRef
25.
go back to reference Solomon LB, Lee YC, Callary SA, Beck M, Howie DW. Anatomy of piriformis, obturator internus and obturator externus: implications for the posterior surgical approach to the hip. J Bone Joint Surg Br. 2010;92:1317–1324.PubMedCrossRef Solomon LB, Lee YC, Callary SA, Beck M, Howie DW. Anatomy of piriformis, obturator internus and obturator externus: implications for the posterior surgical approach to the hip. J Bone Joint Surg Br. 2010;92:1317–1324.PubMedCrossRef
26.
go back to reference Stähelin T, Drittenbass L, Hersche O, Miehlke W, Munzinger U. Failure of capsular enhanced short external rotator repair after total hip replacement. Clin Orthop Relat Res. 2004;420:199–204.PubMedCrossRef Stähelin T, Drittenbass L, Hersche O, Miehlke W, Munzinger U. Failure of capsular enhanced short external rotator repair after total hip replacement. Clin Orthop Relat Res. 2004;420:199–204.PubMedCrossRef
Metadata
Title
Emerging Ideas: Soft Tissue Applications of Radiostereometric Analysis
Authors
Lucian B. Solomon, MD, PhD, FRACS
Stuart A. Callary, BAppSc
Publication date
01-05-2011
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 5/2011
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1681-1

Other articles of this Issue 5/2011

Clinical Orthopaedics and Related Research® 5/2011 Go to the issue