Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 1/2011

01-01-2011 | Symposium: Papers Presented at the Annual Meetings of the Knee Society

Wear and Lysis is the Problem in Modular TKA in the Young OA Patient at 10 Years

Authors: Andrew N. Odland, BS, John J. Callaghan, MD, Steve S. Liu, MD, Christopher W. Wells, BA

Published in: Clinical Orthopaedics and Related Research® | Issue 1/2011

Login to get access

Abstract

Background

Most long-term followup studies of younger patients who underwent TKA include a relatively high percentage of rheumatoid patients, whose function and implant durability may differ from those with osteoarthritis (OA).

Questions/purposes

The purpose of this study was to evaluate the minimum 10 year followup of TKA performed in more active patients with OA, using modular tibial components, to determine the durability of that construct. Specifically, we determined (1) survivorship; (2) revision rates; (3) functional scores; and (4) rates of radiographic failure at a minimum 10 year followup.

Methods

We retrospectively reviewed 59 patients (67 knees) with OA who underwent primary total knee arthroplasty with posterior cruciate retaining (27%) or posterior cruciate substituting (73%) components which had modular tibial trays. Patients were evaluated clinically for need of revision and Knee Society, SF-36 and WOMAC scores as well as UCLA and Tegner activity scores. Radiographs were evaluated for loosening and osteolysis. The minimum followup of living patients was 10 years (mean, 12.4 years; range, 10 to 18.4 years). Ten patients (11 knees) died; two patients (2 knees) were lost to followup.

Results

Ten patients (11 knees; 16%) had revisions for aseptic loosening and/or osteolysis. Thirty-one patients (65%) were still performing moderate labor or sports activities. The average UCLA score was 5.5 (range, 2–9). No nonrevised knee demonstrated radiographic loosening.

Conclusion

Most patients in this active patient population continued to have acceptable function although 16% underwent revision for wear and/or osteolysis. Isolated tibial insert exchange alone was performed in four of the 11 (36%) revised knees. These data should provide comparison for total knee arthroplasties performed in younger patients with newer designs and newer bearing materials.

Level of Evidence

Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: A health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatology. 1988;15:1833–1840. Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: A health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatology. 1988;15:1833–1840.
2.
go back to reference Charnley J. Low Friction Arthroplasty of the Hip: Theory and Practice. Springer-Verlag: Berlin, Germany; 1979:1. Charnley J. Low Friction Arthroplasty of the Hip: Theory and Practice. Springer-Verlag: Berlin, Germany; 1979:1.
3.
go back to reference Conditt MA, Stein JA, Noble PC. Factors affecting the severity of backside wear of modular tibial inserts. J Bone Joint Surg Am. 2004;86:305–311.PubMed Conditt MA, Stein JA, Noble PC. Factors affecting the severity of backside wear of modular tibial inserts. J Bone Joint Surg Am. 2004;86:305–311.PubMed
4.
go back to reference Crowder AR, Duffy GP, Trousdale RT. Long-term results of total knee arthroplasty in young patients with rheumatoid arthritis. J Arthroplasty. 2005;20:12–16.CrossRefPubMed Crowder AR, Duffy GP, Trousdale RT. Long-term results of total knee arthroplasty in young patients with rheumatoid arthritis. J Arthroplasty. 2005;20:12–16.CrossRefPubMed
5.
go back to reference Diduch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D. Total knee arthroplasty in young, active patients. Long-term followup and functional outcome. J Bone and Joint Surg Am. 1997;79:575–582. Diduch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D. Total knee arthroplasty in young, active patients. Long-term followup and functional outcome. J Bone and Joint Surg Am. 1997;79:575–582.
6.
go back to reference Duffy GP, Crowder AR, Trousdale RR, Berry DJ. Cemented total knee arthroplasty using a modern prosthesis in young patients with osteoarthritis. J Arthroplasty. 2007;22:67–70.CrossRefPubMed Duffy GP, Crowder AR, Trousdale RR, Berry DJ. Cemented total knee arthroplasty using a modern prosthesis in young patients with osteoarthritis. J Arthroplasty. 2007;22:67–70.CrossRefPubMed
7.
go back to reference Duffy GP, Trousdale RT, Stuart MJ. Total knee arthroplasty in patients 55 years old or younger: 10–17 year results. Clin Orthop Relat Res. 1998;356:22–27.CrossRefPubMed Duffy GP, Trousdale RT, Stuart MJ. Total knee arthroplasty in patients 55 years old or younger: 10–17 year results. Clin Orthop Relat Res. 1998;356:22–27.CrossRefPubMed
8.
go back to reference Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br. 1992;74:9–17.PubMed Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg Br. 1992;74:9–17.PubMed
9.
go back to reference Engh GA, Lounici S, Rao AR, Collier MB. In vivo deterioration of tibial base-plate locking mechanisms in contemporary modular total knee components. J Bone Joint Surg Am. 2001;83:1660–1665.PubMed Engh GA, Lounici S, Rao AR, Collier MB. In vivo deterioration of tibial base-plate locking mechanisms in contemporary modular total knee components. J Bone Joint Surg Am. 2001;83:1660–1665.PubMed
10.
go back to reference Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.PubMed Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.PubMed
11.
go back to reference Fehring TK, Murphy JA, Hayes TD, Roberts DW, Pomeroy DL, Griffin WL. Factors influencing wear and osteolysis in Press-Fit Condylar modular total knee arthroplastys. Clin Orthop Relat Res. 2004;428:40–50. Fehring TK, Murphy JA, Hayes TD, Roberts DW, Pomeroy DL, Griffin WL. Factors influencing wear and osteolysis in Press-Fit Condylar modular total knee arthroplastys. Clin Orthop Relat Res. 2004;428:40–50.
12.
go back to reference Gill GS, Chan KC, Mills DM. 5- to 15 year followup study of cemented total knee arthroplasty for patients 55 years old or younger. J Arthroplasty. 1997;12:49–54.CrossRefPubMed Gill GS, Chan KC, Mills DM. 5- to 15 year followup study of cemented total knee arthroplasty for patients 55 years old or younger. J Arthroplasty. 1997;12:49–54.CrossRefPubMed
13.
go back to reference Hofmann AA, Heithoff SM, Camargo M. Cementless total knee arthroplasty in patients 50 years or younger. Clin Orthop Relat Res. 2002;404:102–107.CrossRefPubMed Hofmann AA, Heithoff SM, Camargo M. Cementless total knee arthroplasty in patients 50 years or younger. Clin Orthop Relat Res. 2002;404:102–107.CrossRefPubMed
14.
go back to reference Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res.1989;248:13–14. Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res.1989;248:13–14.
15.
go back to reference Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:467–481.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:467–481.CrossRef
16.
go back to reference Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint arthroplasty. Clin Orthop Relat Res. 2009;467:2606–2612.CrossRefPubMed Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint arthroplasty. Clin Orthop Relat Res. 2009;467:2606–2612.CrossRefPubMed
17.
go back to reference Lonner JH, Hershman S, Mont M, Lotke PA. Total knee arthroplasty in patients 40 years of age and younger with osteoarthritis. Clin Orthop Relat Res. 2000;380:85–90.CrossRefPubMed Lonner JH, Hershman S, Mont M, Lotke PA. Total knee arthroplasty in patients 40 years of age and younger with osteoarthritis. Clin Orthop Relat Res. 2000;380:85–90.CrossRefPubMed
18.
go back to reference Malin AS, Callaghan JJ, Bozic KJ, Liu SS, Goetz DD, Sullivan N, Kelley SS. Routine surveillance of modular PFC tka shows increasing failures after 10 years. Clin Orthop Relat Res. 2010 Mar 19. [Epub ahead of print]. Malin AS, Callaghan JJ, Bozic KJ, Liu SS, Goetz DD, Sullivan N, Kelley SS. Routine surveillance of modular PFC tka shows increasing failures after 10 years. Clin Orthop Relat Res. 2010 Mar 19. [Epub ahead of print].
19.
go back to reference Mont MA, Lee CW, Sheldon M, Lennon WC, Hungerford DS. Total knee arthroplasty in patients ≤ 50 years old. J Arthroplasty. 2002;17:538–543.CrossRefPubMed Mont MA, Lee CW, Sheldon M, Lennon WC, Hungerford DS. Total knee arthroplasty in patients ≤ 50 years old. J Arthroplasty. 2002;17:538–543.CrossRefPubMed
20.
go back to reference O’Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up. J Bone Joint Surg Am. 2002;84:1362–1371.PubMed O’Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up. J Bone Joint Surg Am. 2002;84:1362–1371.PubMed
21.
go back to reference Parks NL, Engh GA, Topoleski LD, Emperado J. Modular tibial insert micromotion. A concern with contemporary knee implants. Clin Orthop Relat Res.1998;356:10–15.CrossRefPubMed Parks NL, Engh GA, Topoleski LD, Emperado J. Modular tibial insert micromotion. A concern with contemporary knee implants. Clin Orthop Relat Res.1998;356:10–15.CrossRefPubMed
22.
go back to reference Ranawat AS, Shubhranshu SM, Goldsmith SE, Rasquinha VJ, Rodriguez JA, Ranawat CS. Experience with an all-polyethylene total knee arthroplasty in younger, active patients with followup from 2–11 years. J Arthroplasty. 2005;20:7–11.CrossRefPubMed Ranawat AS, Shubhranshu SM, Goldsmith SE, Rasquinha VJ, Rodriguez JA, Ranawat CS. Experience with an all-polyethylene total knee arthroplasty in younger, active patients with followup from 2–11 years. J Arthroplasty. 2005;20:7–11.CrossRefPubMed
23.
go back to reference Stern SH, Bowen MK, Insall JN, Scuderi GR. Cemented total knee arthroplasty for gonarthrosis in patients 55 years old or younger. Clin Orthop Relat Res. 1990;260:124–129.PubMed Stern SH, Bowen MK, Insall JN, Scuderi GR. Cemented total knee arthroplasty for gonarthrosis in patients 55 years old or younger. Clin Orthop Relat Res. 1990;260:124–129.PubMed
24.
go back to reference Tai CC, Cross MJ. Five- to 12-year followup of a hydroxyapatite-coated, cementless total knee arthroplasty in young, active patients. J Bone Joint Surg Br. 2006;88:1158–1163.CrossRefPubMed Tai CC, Cross MJ. Five- to 12-year followup of a hydroxyapatite-coated, cementless total knee arthroplasty in young, active patients. J Bone Joint Surg Br. 2006;88:1158–1163.CrossRefPubMed
25.
go back to reference Tegner Y, Lysholm J. Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res. 1985;198:43–49.PubMed Tegner Y, Lysholm J. Rating systems in the evaluation of knee ligament injuries. Clin Orthop Relat Res. 1985;198:43–49.PubMed
26.
go back to reference Zahiri C, Schmalried TP, Szuszczewicz ES, Amstutz HC. Assessing activity in joint arthroplasty patients. J Arthroplasty. 1998;12:890–895.CrossRef Zahiri C, Schmalried TP, Szuszczewicz ES, Amstutz HC. Assessing activity in joint arthroplasty patients. J Arthroplasty. 1998;12:890–895.CrossRef
Metadata
Title
Wear and Lysis is the Problem in Modular TKA in the Young OA Patient at 10 Years
Authors
Andrew N. Odland, BS
John J. Callaghan, MD
Steve S. Liu, MD
Christopher W. Wells, BA
Publication date
01-01-2011
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 1/2011
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1429-y

Other articles of this Issue 1/2011

Clinical Orthopaedics and Related Research® 1/2011 Go to the issue

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Biographical Sketch: William Russell MacAusland, MD 1882–1965

Symposium: Papers Presented at the Annual Meetings of the Knee Society

The Peel in Total Knee Revision: Exposure in the Difficult Knee

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Liner Exchange and Bone Grafting: Rare Option to Treat Wear & Lysis of Stable TKAs