Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 10/2009

01-10-2009 | Original Article

Clinical Comparison of Polyethylene Wear with Zirconia or Cobalt-Chromium Femoral Heads

Authors: Maiken Stilling, MD, Kjeld Anton Nielsen, MD, Kjeld Søballe, MD, DMSc, Ole Rahbek, MD, PhD

Published in: Clinical Orthopaedics and Related Research® | Issue 10/2009

Login to get access

Abstract

Ceramic femoral heads were developed to reduce the wear of conventional ultrahigh-molecular-weight polyethylene (UHMWPE) bearing surfaces in THA. We compared the wear rates of PE acetabular components bearing against femoral heads of zirconia (Zr) or cobalt-chromium (CoCr) in young patients. One surgeon inserted CoCr femoral heads in all 33 patients (33 hips) having THA for primary osteoarthritis from 1996 to 1997 and then Zr femoral heads in all 34 patients (36 hips) from 1998 to 1999. The mean age of the entire cohort was 52.5 years (range, 29–64 years). The shells were solid and hydroxyapatite (HA) -coated, liners were argon-sterilized UHMWPE, and head size was 28 mm. The minimum clinical followup was 56 months (mean, 65 months; range, 56–77 months); minimum 5-year radiographs were available for 62 of the 68 patients. Wear analysis of digitized anteroposterior (AP) radiographs was performed with a computerized method. Demographic data were comparable in the two groups. Mean femoral head penetration rate was similar in the two types of heads (CoCr: 0.25 mm/year; range, 0.21–0.33 mm/year; Zr: 0.23 mm/year; range, 0.20–0.29 mm/year), as was mean linear wear (CoCr: 1.22 mm; range, 0.28–3.78 mm; Zr: 1.11 mm; range, 0.15–2.05 mm). There were no revisions. These data support skepticism regarding the clinical wear advantage of Zr compared with CoCr femoral heads. The explanation for the clinical similarity of wear, despite the theoretical advantages of ceramic heads, needs further investigation.
Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Allain J, Le Mouel S, Goutallier D, Voisin MC. Poor eight-year survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg Br. 1999;81:835–842.PubMedCrossRef Allain J, Le Mouel S, Goutallier D, Voisin MC. Poor eight-year survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg Br. 1999;81:835–842.PubMedCrossRef
2.
go back to reference Altman DG. Practical Statistics for Medical Research. 1995 ed. London, UK: Chapman & Hall; 2009. Altman DG. Practical Statistics for Medical Research. 1995 ed. London, UK: Chapman & Hall; 2009.
3.
go back to reference Bauer TW. Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br. 1998;80:745.PubMed Bauer TW. Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating. J Bone Joint Surg Br. 1998;80:745.PubMed
4.
go back to reference Bauer TW, Hirakawa K. Osteolysis: a generic problem. Orthopedics. 1995;18:791–794.PubMed Bauer TW, Hirakawa K. Osteolysis: a generic problem. Orthopedics. 1995;18:791–794.PubMed
5.
go back to reference Cales B. Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop Relat Res. 2000;379:94–112.PubMedCrossRef Cales B. Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop Relat Res. 2000;379:94–112.PubMedCrossRef
6.
go back to reference Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop Relat Res. 2000;379:34–40.PubMedCrossRef Clarke IC, Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop Relat Res. 2000;379:34–40.PubMedCrossRef
7.
go back to reference Cohn RM, Gonzalez Della Valle A, Peterson M, Cornell CN. Similar wear in total hip arthroplasties with metallic or zirconia femoral heads. HSS J. 2008;4:107–111.PubMedCrossRef Cohn RM, Gonzalez Della Valle A, Peterson M, Cornell CN. Similar wear in total hip arthroplasties with metallic or zirconia femoral heads. HSS J. 2008;4:107–111.PubMedCrossRef
8.
go back to reference Collier MB, Kraay MJ, Rimnac CM, Goldberg VM. Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85:2410–2418.PubMed Collier MB, Kraay MJ, Rimnac CM, Goldberg VM. Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85:2410–2418.PubMed
9.
go back to reference Cooper RA, McAllister CM, Borden LS, Bauer TW. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty: a cause of late failure. J Arthroplasty. 1992;7:285–290.PubMedCrossRef Cooper RA, McAllister CM, Borden LS, Bauer TW. Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty: a cause of late failure. J Arthroplasty. 1992;7:285–290.PubMedCrossRef
10.
go back to reference Cuckler JM, Bearcroft J, Asgian CM. Femoral head technologies to reduce polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 1995;317:57–63.PubMed Cuckler JM, Bearcroft J, Asgian CM. Femoral head technologies to reduce polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 1995;317:57–63.PubMed
11.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
12.
go back to reference Derbyshire B, Fisher J, Dowson D, Hardaker C, Brummitt K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med Eng Phys. 1994;16:229–236.PubMedCrossRef Derbyshire B, Fisher J, Dowson D, Hardaker C, Brummitt K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med Eng Phys. 1994;16:229–236.PubMedCrossRef
13.
go back to reference Devane PA, Bourne RB, Rorabeck CH, Hardie RM, Horne JG. Measurement of polyethylene wear in metal-backed acetabular cups: I. Three-dimensional technique. Clin Orthop Relat Res. 1995;319:303–316.PubMed Devane PA, Bourne RB, Rorabeck CH, Hardie RM, Horne JG. Measurement of polyethylene wear in metal-backed acetabular cups: I. Three-dimensional technique. Clin Orthop Relat Res. 1995;319:303–316.PubMed
14.
go back to reference Devane PA, Bourne RB, Rorabeck CH, MacDonald S, Robinson EJ. Measurement of polyethylene wear in metal-backed acetabular cups: II. Clinical application. Clin Orthop Relat Res. 1995;319:317–326.PubMed Devane PA, Bourne RB, Rorabeck CH, MacDonald S, Robinson EJ. Measurement of polyethylene wear in metal-backed acetabular cups: II. Clinical application. Clin Orthop Relat Res. 1995;319:317–326.PubMed
15.
go back to reference Dowd JE, Sychterz CJ, Young AM, Engh CA. Characterization of long-term femoral-head-penetration rates: association with and prediction of osteolysis. J Bone Joint Surg Am. 2000;82:1102–1107.PubMed Dowd JE, Sychterz CJ, Young AM, Engh CA. Characterization of long-term femoral-head-penetration rates: association with and prediction of osteolysis. J Bone Joint Surg Am. 2000;82:1102–1107.PubMed
16.
go back to reference Ebramzadeh E, Sangiorgio SN, Lattuada F, Kang JS, Chiesa R, McKellop HA, Dorr LD. Accuracy of measurement of polyethylene wear with use of radiographs of total hip replacements. J Bone Joint Surg Am. 2003;85:2378–2384.PubMed Ebramzadeh E, Sangiorgio SN, Lattuada F, Kang JS, Chiesa R, McKellop HA, Dorr LD. Accuracy of measurement of polyethylene wear with use of radiographs of total hip replacements. J Bone Joint Surg Am. 2003;85:2378–2384.PubMed
17.
go back to reference Hernigou P, Bahrami T. Zirconia and alumina ceramics in comparison with stainless-steel heads: polyethylene wear after a minimum ten-year follow-up. J Bone Joint Surg Br. 2003;85:504–509.PubMedCrossRef Hernigou P, Bahrami T. Zirconia and alumina ceramics in comparison with stainless-steel heads: polyethylene wear after a minimum ten-year follow-up. J Bone Joint Surg Br. 2003;85:504–509.PubMedCrossRef
18.
go back to reference Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH. Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85:505–511.PubMed Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH. Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85:505–511.PubMed
19.
go back to reference Hummer CD 3rd, Rothman RH, Hozack WJ. Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty. J Arthroplasty. 1995;10:848–850.PubMedCrossRef Hummer CD 3rd, Rothman RH, Hozack WJ. Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty. J Arthroplasty. 1995;10:848–850.PubMedCrossRef
20.
go back to reference Kim YH. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: a prospective, randomized study. J Bone Joint Surg Am. 2005;87:1769–1776.PubMedCrossRef Kim YH. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement: a prospective, randomized study. J Bone Joint Surg Am. 2005;87:1769–1776.PubMedCrossRef
21.
go back to reference Kim YH, Kim JS. Tribological and material analyses of retrieved alumina and zirconia ceramic heads correlated with polyethylene wear after total hip replacement. J Bone Joint Surg Br. 2008;90:731–737.PubMed Kim YH, Kim JS. Tribological and material analyses of retrieved alumina and zirconia ceramic heads correlated with polyethylene wear after total hip replacement. J Bone Joint Surg Br. 2008;90:731–737.PubMed
22.
go back to reference Kim YH, Kim JS, Cho SH. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads: a prospective, randomised study. J Bone Joint Surg Br. 2001;83:742–750.PubMedCrossRef Kim YH, Kim JS, Cho SH. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads: a prospective, randomised study. J Bone Joint Surg Br. 2001;83:742–750.PubMedCrossRef
23.
go back to reference Kraay MJ, Thomas RD, Rimnac CM, Fitzgerald SJ, Goldberg VM. Zirconia versus Co-Cr femoral heads in total hip arthroplasty: early assessment of wear. Clin Orthop Relat Res. 2006;453:86–90.PubMedCrossRef Kraay MJ, Thomas RD, Rimnac CM, Fitzgerald SJ, Goldberg VM. Zirconia versus Co-Cr femoral heads in total hip arthroplasty: early assessment of wear. Clin Orthop Relat Res. 2006;453:86–90.PubMedCrossRef
24.
go back to reference Kumar P, Oka M, Ikeuchi K, Shimizu K, Yamamuro T, Okumura H, Kotoura Y. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res. 1991;25:813–828.PubMedCrossRef Kumar P, Oka M, Ikeuchi K, Shimizu K, Yamamuro T, Okumura H, Kotoura Y. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res. 1991;25:813–828.PubMedCrossRef
25.
go back to reference Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–528.PubMed Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–528.PubMed
26.
go back to reference Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed
27.
go back to reference Oldenburg M, Wegner R, Baur X. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty. 2008 Oct 1. [Epub ahead of print]. Oldenburg M, Wegner R, Baur X. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty. 2008 Oct 1. [Epub ahead of print].
28.
go back to reference Piconi C, Maccauro G, Angeloni M, Rossi B, Learmonth ID. Zirconia heads in perspective: a survey of zirconia outcomes in total hip replacement. Hip Int. 2007;17:119–130.PubMed Piconi C, Maccauro G, Angeloni M, Rossi B, Learmonth ID. Zirconia heads in perspective: a survey of zirconia outcomes in total hip replacement. Hip Int. 2007;17:119–130.PubMed
29.
go back to reference Saikko V. Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip-joint simulator. Wear. 1994;176:207–212.CrossRef Saikko V. Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip-joint simulator. Wear. 1994;176:207–212.CrossRef
30.
go back to reference Schmalzried TP, Huk OL. Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res. 2004;418:94–97.PubMedCrossRef Schmalzried TP, Huk OL. Patient factors and wear in total hip arthroplasty. Clin Orthop Relat Res. 2004;418:94–97.PubMedCrossRef
31.
go back to reference Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty: polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am. 1992;74:849–863.PubMed Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hip arthroplasty: polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am. 1992;74:849–863.PubMed
32.
go back to reference Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.PubMedCrossRef Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award. Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.PubMedCrossRef
33.
go back to reference Sychterz CJ, Engh CA Jr, Yang A, Engh CA. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. J Bone Joint Surg Am. 1999;81:821–830.PubMedCrossRef Sychterz CJ, Engh CA Jr, Yang A, Engh CA. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. J Bone Joint Surg Am. 1999;81:821–830.PubMedCrossRef
34.
go back to reference von Schewelov T, Sanzen L, Borlin N, Markusson P, Onsten I. Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study. Acta Orthop Scand. 2004;75:691–700.CrossRef von Schewelov T, Sanzen L, Borlin N, Markusson P, Onsten I. Accuracy of radiographic and radiostereometric wear measurement of different hip prostheses: an experimental study. Acta Orthop Scand. 2004;75:691–700.CrossRef
35.
go back to reference von Schewelov T, Sanzen L, Onsten I, Carlsson A, Besjakov J. Total hip replacement with a zirconium oxide ceramic femoral head: a randomised roentgen stereophotogrammetric study. J Bone Joint Surg Br. 2005;87:1631–1635. von Schewelov T, Sanzen L, Onsten I, Carlsson A, Besjakov J. Total hip replacement with a zirconium oxide ceramic femoral head: a randomised roentgen stereophotogrammetric study. J Bone Joint Surg Br. 2005;87:1631–1635.
36.
go back to reference Wan Z, Dorr LD. Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant. J Arthroplasty 1996;11:718–725.PubMedCrossRef Wan Z, Dorr LD. Natural history of femoral focal osteolysis with proximal ingrowth smooth stem implant. J Arthroplasty 1996;11:718–725.PubMedCrossRef
Metadata
Title
Clinical Comparison of Polyethylene Wear with Zirconia or Cobalt-Chromium Femoral Heads
Authors
Maiken Stilling, MD
Kjeld Anton Nielsen, MD
Kjeld Søballe, MD, DMSc
Ole Rahbek, MD, PhD
Publication date
01-10-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 10/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-0799-5

Other articles of this Issue 10/2009

Clinical Orthopaedics and Related Research® 10/2009 Go to the issue

Symposium: ABJS Carl T. Brighton Workshop on Health Policy Issues in Orthopaedic Surgery

What Rate of Utilization is Appropriate in Musculoskeletal Care?

Symposium: ABJS Carl T. Brighton Workshop on Health Policy Issues in Orthopaedic Surgery

The Impact of Physician-owned Specialty Orthopaedic Hospitals on Surgical Volume and Case Complexity in Competing Hospitals

Symposium: ABJS Carl T. Brighton Workshop on Health Policy Issues in Orthopaedic Surgery

The Classic: A Plan for a More Effective Federal and State Health Administration