Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 10/2008

01-10-2008 | Original Article

Acetabular Revision with Metal Mesh, Impaction Bone Grafting, and a Cemented Cup

Authors: Martín A. Buttaro, MD, Fernando Comba, MD, Rodolfo Pusso, MD, Francisco Piccaluga, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 10/2008

Login to get access

Abstract

Impaction grafting is controversial in the presence of segmental and cavitary acetabular defects and requires the use of supplemental devices to close segmental defects. This approach, however, would allow treating combined deficiencies that could not be managed with impacted cancellous bone alone. We raised the following two questions: (1) What is the survival rate in patients with combined deficiencies reconstructed with metal mesh, impaction grafting and a cemented cup and (2) can metal mesh prevent cup migration? We evaluated 23 cavitary uncontained acetabular defects in revision hip arthroplasty. Preoperative diagnoses were aseptic loosening (19 hips) and second-stage reimplantations after resection for infection (four hips). The preoperative Merle D’Aubigné-Postel score averaged 7.4 points. Two patients had reoperations for mechanical failure at 6 and 24 months. The survival rate with further revision as an end point was 90.8% at an average of 36 months (range, 24–56 months; 95% confidence interval, 68.1–97.6). Metal mesh did not prevent cup migration: migration occurred in all patients, averaging 5.1 mm (range, 2–25 mm). Another three patients with severe combined defects had asymptomatic mesh rupture with 3- to 15-mm migration. Postoperative functional score averaged 16.2 points. Metal mesh, impaction grafting, and a cemented cup should be considered for reconstruction of medium uncontained acetabular defects, but not for severe combined deficiencies.
Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Ackland MK, Bourne WB, Uhthoff HK. Anteversion of the acetabular cup: measurement of angle after total hip replacement. J Bone Joint Surg Br. 1986;68:409–413.PubMed Ackland MK, Bourne WB, Uhthoff HK. Anteversion of the acetabular cup: measurement of angle after total hip replacement. J Bone Joint Surg Br. 1986;68:409–413.PubMed
2.
go back to reference Azuma T, Yasuda H, Okagaki K, Sakai K. Compressed allograft chips for acetabular reconstruction in revision hip arthroplasty. J Bone Joint Surg Br. 1994;76:740–744.PubMed Azuma T, Yasuda H, Okagaki K, Sakai K. Compressed allograft chips for acetabular reconstruction in revision hip arthroplasty. J Bone Joint Surg Br. 1994;76:740–744.PubMed
3.
go back to reference Berry DJ, Muller ME. Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency. J Bone Joint Surg Br. 1992;74:711–715.PubMed Berry DJ, Muller ME. Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency. J Bone Joint Surg Br. 1992;74:711–715.PubMed
4.
go back to reference Berry DJ, Sutherland CJ, Trousdale RT, Colwell CW Jr, Chandler HP, Ayres D, Yashar AA. Bilobed oblong porous coated acetabular components in revision total hip arthroplasty. Clin Orthop Relat Res. 2000;371:154–160.PubMedCrossRef Berry DJ, Sutherland CJ, Trousdale RT, Colwell CW Jr, Chandler HP, Ayres D, Yashar AA. Bilobed oblong porous coated acetabular components in revision total hip arthroplasty. Clin Orthop Relat Res. 2000;371:154–160.PubMedCrossRef
5.
go back to reference Bolder SB, Schreurs BW, Verdonschot N, Veth RP, Buma P. Wire mesh allows more revascularization than a strut in impaction bone grafting: an animal study in goats. Clin Orthop Relat Res. 2004;423:280–286.PubMedCrossRef Bolder SB, Schreurs BW, Verdonschot N, Veth RP, Buma P. Wire mesh allows more revascularization than a strut in impaction bone grafting: an animal study in goats. Clin Orthop Relat Res. 2004;423:280–286.PubMedCrossRef
6.
go back to reference Boldt JG, Dilawari P, Agarwal S, Drabu KJ. Revision total hip arthroplasty using impaction bone grafting with cemented nonpolished stems and Charnley cups. J Arthroplasty. 2001;16:943–952.PubMedCrossRef Boldt JG, Dilawari P, Agarwal S, Drabu KJ. Revision total hip arthroplasty using impaction bone grafting with cemented nonpolished stems and Charnley cups. J Arthroplasty. 2001;16:943–952.PubMedCrossRef
7.
go back to reference Buttaro M, Araujo GS, Araujo ES, Comba F, Piccaluga F. Viability of impacted bone allografts under calcar metal mesh in revision surgery of the hip: case report. J Bone Joint Surg Br. 2008;90:228–231.PubMedCrossRef Buttaro M, Araujo GS, Araujo ES, Comba F, Piccaluga F. Viability of impacted bone allografts under calcar metal mesh in revision surgery of the hip: case report. J Bone Joint Surg Br. 2008;90:228–231.PubMedCrossRef
8.
go back to reference Comba F, Buttaro M, Pusso R, Piccaluga F. Acetabular reconstruction with impacted bone allografts and cemented acetabular components: a 2- to 13-year follow-up study of 142 aseptic revisions. J Bone Joint Surg Br. 2006;88:865–869.PubMedCrossRef Comba F, Buttaro M, Pusso R, Piccaluga F. Acetabular reconstruction with impacted bone allografts and cemented acetabular components: a 2- to 13-year follow-up study of 142 aseptic revisions. J Bone Joint Surg Br. 2006;88:865–869.PubMedCrossRef
9.
go back to reference Comba F, Buttaro M, Pusso R, Piccaluga F. Acetabular revision surgery with impacted bone allografts and cemented cups in patients younger than 55 years. Int Orthop. 2008 Feb 9 [Epub ahead of print]. Comba F, Buttaro M, Pusso R, Piccaluga F. Acetabular revision surgery with impacted bone allografts and cemented cups in patients younger than 55 years. Int Orthop. 2008 Feb 9 [Epub ahead of print].
10.
go back to reference D’Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF, Boettcher WG, Steinberg ME, Stulberg SD, Wedge JH. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res. 1989;243:126–137.PubMed D’Antonio JA, Capello WN, Borden LS, Bargar WL, Bierbaum BF, Boettcher WG, Steinberg ME, Stulberg SD, Wedge JH. Classification and management of acetabular abnormalities in total hip arthroplasty. Clin Orthop Relat Res. 1989;243:126–137.PubMed
11.
go back to reference D’Aubigné RM, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.PubMed D’Aubigné RM, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.PubMed
12.
go back to reference Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty: results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469–480.PubMed Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty: results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469–480.PubMed
13.
go back to reference Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8–15.PubMedCrossRef Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8–15.PubMedCrossRef
14.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
15.
go back to reference Fawcett K, Barr AR. Tissue Banking. McLean, VA: American Association of Tissue Banks; 1987. Fawcett K, Barr AR. Tissue Banking. McLean, VA: American Association of Tissue Banks; 1987.
16.
go back to reference Gie GA, Linder L, Ling RS, Simon JP, Slooff TJ, Timperley AJ. Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg Br. 1993;75:14–21.PubMed Gie GA, Linder L, Ling RS, Simon JP, Slooff TJ, Timperley AJ. Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg Br. 1993;75:14–21.PubMed
17.
go back to reference Gill TJ, Sledge JB, Muller ME. The Burch-Schneider anti-protrusio cage in revision total hip arthroplasty: indications, principles and long-term results. J Bone Joint Surg Br. 1998;80:946–953.PubMedCrossRef Gill TJ, Sledge JB, Muller ME. The Burch-Schneider anti-protrusio cage in revision total hip arthroplasty: indications, principles and long-term results. J Bone Joint Surg Br. 1998;80:946–953.PubMedCrossRef
18.
go back to reference Goodman S, Saastamoinen H, Shasha N, Gross A. Complications of ilioischial reconstruction rings in revision total hip arthroplasty. J Arthroplasty. 2004;19:436–446.PubMedCrossRef Goodman S, Saastamoinen H, Shasha N, Gross A. Complications of ilioischial reconstruction rings in revision total hip arthroplasty. J Arthroplasty. 2004;19:436–446.PubMedCrossRef
19.
go back to reference Gustilo RB, Pasternak HS. Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening. Clin Orthop Relat Res. 1988;235:111–119.PubMed Gustilo RB, Pasternak HS. Revision total hip arthroplasty with titanium ingrowth prosthesis and bone grafting for failed cemented femoral component loosening. Clin Orthop Relat Res. 1988;235:111–119.PubMed
20.
go back to reference Harris WH. Allografting in total hip arthroplasty: in adults with severe acetabular deficiency including a surgical technique for bolting the graft to the ilium. Clin Orthop Relat Res. 1982;162:150–164.PubMed Harris WH. Allografting in total hip arthroplasty: in adults with severe acetabular deficiency including a surgical technique for bolting the graft to the ilium. Clin Orthop Relat Res. 1982;162:150–164.PubMed
21.
go back to reference Harris WH, Jones WN. The use of wire mesh in total hip replacement surgery. Clin Orthop Relat Res. 1975;106:117–121.PubMedCrossRef Harris WH, Jones WN. The use of wire mesh in total hip replacement surgery. Clin Orthop Relat Res. 1975;106:117–121.PubMedCrossRef
23.
go back to reference Jasty M, Harris WH. Results of total hip reconstruction using acetabular mesh in patients with central acetabular deficiency. Clin Orthop Relat Res. 1988;237:142–149.PubMed Jasty M, Harris WH. Results of total hip reconstruction using acetabular mesh in patients with central acetabular deficiency. Clin Orthop Relat Res. 1988;237:142–149.PubMed
24.
go back to reference Jasty M, Harris WH. Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allografts. J Bone Joint Surg Br. 1990;72:63–67.PubMed Jasty M, Harris WH. Salvage total hip reconstruction in patients with major acetabular bone deficiency using structural femoral head allografts. J Bone Joint Surg Br. 1990;72:63–67.PubMed
25.
go back to reference Kaplan E, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef Kaplan E, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–481.CrossRef
26.
go back to reference Katz RP, Callaghan JJ, Sullivan PM, Johnston RC. Long-term results of revision total hip arthroplasty with improved cementing technique. J Bone Joint Surg Br. 1997;79:322–326.PubMedCrossRef Katz RP, Callaghan JJ, Sullivan PM, Johnston RC. Long-term results of revision total hip arthroplasty with improved cementing technique. J Bone Joint Surg Br. 1997;79:322–326.PubMedCrossRef
28.
go back to reference Kerboull M, Hamadouche M, Kerboull L. The Kerboull acetabular reinforcement device in major acetabular reconstructions. Clin Orthop Relat Res. 2000;378:155–168.PubMedCrossRef Kerboull M, Hamadouche M, Kerboull L. The Kerboull acetabular reinforcement device in major acetabular reconstructions. Clin Orthop Relat Res. 2000;378:155–168.PubMedCrossRef
29.
go back to reference Koster G, Willert HG, Kohler HP, Dopkens K. An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up. J Arthroplasty. 1998;13:559–569.PubMedCrossRef Koster G, Willert HG, Kohler HP, Dopkens K. An oblong revision cup for large acetabular defects: design rationale and two- to seven-year follow-up. J Arthroplasty. 1998;13:559–569.PubMedCrossRef
30.
go back to reference Levinthal GS. Titanium, a metal for surgery. J Bone Joint Surg Am. 1951;33:473–474. Levinthal GS. Titanium, a metal for surgery. J Bone Joint Surg Am. 1951;33:473–474.
31.
go back to reference Lockey MW, Hahn GW, Corgill DA. Mandibular fractures: metallic implant fixation using vitallium mesh. Arch Otolaryngol. 1966;84:451–456.PubMed Lockey MW, Hahn GW, Corgill DA. Mandibular fractures: metallic implant fixation using vitallium mesh. Arch Otolaryngol. 1966;84:451–456.PubMed
32.
go back to reference Mowe JC. Standards for Tissue Banking. Arlington, VA: American Association of Tissue Banks; 1988. Mowe JC. Standards for Tissue Banking. Arlington, VA: American Association of Tissue Banks; 1988.
33.
go back to reference Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201–208.PubMedCrossRef Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201–208.PubMedCrossRef
34.
go back to reference Nunez LV, Buttaro MA, Morandi A, Pusso R, Piccaluga F. Frozen sections of samples taken intraoperatively for diagnosis of infection in revision hip surgery. Acta Orthop. 2007;78:226–230.PubMedCrossRef Nunez LV, Buttaro MA, Morandi A, Pusso R, Piccaluga F. Frozen sections of samples taken intraoperatively for diagnosis of infection in revision hip surgery. Acta Orthop. 2007;78:226–230.PubMedCrossRef
35.
go back to reference Ornstein E, Franzen H, Johnsson R, Stefansdottir A, Sundberg M, Tagil M. Five-year follow-up of socket movements and loosening after revision with impacted morselized allograft bone and cement: a radiostereometric and radiographic analysis. J Arthroplasty. 2006;21:975–984.PubMedCrossRef Ornstein E, Franzen H, Johnsson R, Stefansdottir A, Sundberg M, Tagil M. Five-year follow-up of socket movements and loosening after revision with impacted morselized allograft bone and cement: a radiostereometric and radiographic analysis. J Arthroplasty. 2006;21:975–984.PubMedCrossRef
36.
go back to reference Patel JV, Masonis JL, Bourne RB, Rorabeck CH. The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003;18:129–133.PubMedCrossRef Patel JV, Masonis JL, Bourne RB, Rorabeck CH. The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003;18:129–133.PubMedCrossRef
37.
go back to reference Piccaluga F, Gonzalez Della Valle A, Encinas Fernandez JC, Pusso R. Revision of the femoral prosthesis with impaction allografting and a Charnley stem: a 2- to 12-year follow-up. J Bone Joint Surg Br. 2002;84:544–549.PubMedCrossRef Piccaluga F, Gonzalez Della Valle A, Encinas Fernandez JC, Pusso R. Revision of the femoral prosthesis with impaction allografting and a Charnley stem: a 2- to 12-year follow-up. J Bone Joint Surg Br. 2002;84:544–549.PubMedCrossRef
38.
go back to reference Roidis N, Karachalios T, Khaldi L, Stamos K, Lyritis GP. The role of stainless steel wire mesh and cement in bone allograft incorporation in impaction grafting technique: an experimental study in rabbits. J Arthroplasty. 2003;18:484–493.PubMedCrossRef Roidis N, Karachalios T, Khaldi L, Stamos K, Lyritis GP. The role of stainless steel wire mesh and cement in bone allograft incorporation in impaction grafting technique: an experimental study in rabbits. J Arthroplasty. 2003;18:484–493.PubMedCrossRef
39.
go back to reference Rosenberg WW, Schreurs BW, de Waal Malefijt MC, Veth RP, Slooff TJ. Impacted morsellized bone grafting and cemented primary total hip arthroplasty for acetabular protrusion in patients with rheumatoid arthritis: an 8- to 18-year follow-up study of 36 hips. Acta Orthop Scand. 2000;71:143–146.PubMedCrossRef Rosenberg WW, Schreurs BW, de Waal Malefijt MC, Veth RP, Slooff TJ. Impacted morsellized bone grafting and cemented primary total hip arthroplasty for acetabular protrusion in patients with rheumatoid arthritis: an 8- to 18-year follow-up study of 36 hips. Acta Orthop Scand. 2000;71:143–146.PubMedCrossRef
40.
go back to reference Rosson J, Schatzker J. The use of reinforcement rings to reconstruct deficient acetabula. J Bone Joint Surg Br. 1992;74:716–720.PubMed Rosson J, Schatzker J. The use of reinforcement rings to reconstruct deficient acetabula. J Bone Joint Surg Br. 1992;74:716–720.PubMed
41.
go back to reference Schnur DS, Lee D. Stiffness and inelastic deformation in acrylic titanium composite implant materials under compression. J Biomed Mater Res. 1983;17:973–991.PubMedCrossRef Schnur DS, Lee D. Stiffness and inelastic deformation in acrylic titanium composite implant materials under compression. J Biomed Mater Res. 1983;17:973–991.PubMedCrossRef
42.
go back to reference Schreurs BW, Bolder SB, Gardeniers JW, Verdonschot N, Slooff TJ, Veth RP. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup: a 15- to 20-year follow-up. J Bone Joint Surg Br. 2004;86:492–497.PubMed Schreurs BW, Bolder SB, Gardeniers JW, Verdonschot N, Slooff TJ, Veth RP. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup: a 15- to 20-year follow-up. J Bone Joint Surg Br. 2004;86:492–497.PubMed
43.
go back to reference Schreurs BW, Slooff TJ, Buma P, Verdonschot N. Basic science of bone impaction grafting. Instr Course Lect. 2001;50:211–220.PubMed Schreurs BW, Slooff TJ, Buma P, Verdonschot N. Basic science of bone impaction grafting. Instr Course Lect. 2001;50:211–220.PubMed
44.
go back to reference Schreurs BW, Slooff TJ, Gardeniers JW, Buma P. Acetabular reconstruction with bone impaction grafting and a cemented cup: 20 years’ experience. Clin Orthop Relat Res. 2001;393:202–215.PubMedCrossRef Schreurs BW, Slooff TJ, Gardeniers JW, Buma P. Acetabular reconstruction with bone impaction grafting and a cemented cup: 20 years’ experience. Clin Orthop Relat Res. 2001;393:202–215.PubMedCrossRef
45.
go back to reference Schutzer SF, Harris WH. High placement of porous-coated acetabular components in complex total hip arthroplasty. J Arthroplasty. 1994;9:359–367.PubMedCrossRef Schutzer SF, Harris WH. High placement of porous-coated acetabular components in complex total hip arthroplasty. J Arthroplasty. 1994;9:359–367.PubMedCrossRef
46.
go back to reference Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty: sixteen-year-average follow-up. J Bone Joint Surg Am. 1997;79:159–168.PubMed Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty: sixteen-year-average follow-up. J Bone Joint Surg Am. 1997;79:159–168.PubMed
47.
go back to reference Silverton CD, Rosenberg AG, Sheinkop MB, Kull LR, Galante JO. Revision of the acetabular component without cement after total hip arthroplasty: a follow-up note regarding results at seven to eleven years. J Bone Joint Surg Am. 1996;78:1366–1370.PubMed Silverton CD, Rosenberg AG, Sheinkop MB, Kull LR, Galante JO. Revision of the acetabular component without cement after total hip arthroplasty: a follow-up note regarding results at seven to eleven years. J Bone Joint Surg Am. 1996;78:1366–1370.PubMed
48.
go back to reference Slooff TJ, Huiskes R, van Horn J, Lemmens AJ. Bone grafting in total hip replacement for acetabular protrusion. Acta Orthop Scand. 1984;55:593–596.PubMedCrossRef Slooff TJ, Huiskes R, van Horn J, Lemmens AJ. Bone grafting in total hip replacement for acetabular protrusion. Acta Orthop Scand. 1984;55:593–596.PubMedCrossRef
49.
go back to reference Slooff TJ, Schimmel JW, Buma P. Cemented fixation with bone grafts. Orthop Clin North Am. 1993;24:667–677.PubMed Slooff TJ, Schimmel JW, Buma P. Cemented fixation with bone grafts. Orthop Clin North Am. 1993;24:667–677.PubMed
50.
go back to reference Taitsman JP, Saha S. Tensile strength of wire-reinforced bone cement and twisted stainless-steel wire. J Bone Joint Surg Am. 1977;59:419–425.PubMed Taitsman JP, Saha S. Tensile strength of wire-reinforced bone cement and twisted stainless-steel wire. J Bone Joint Surg Am. 1977;59:419–425.PubMed
51.
go back to reference Templeton JE, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component: a ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed Templeton JE, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component: a ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed
52.
go back to reference Trancik TM, Stulberg BN, Wilde AH, Feiglin DH. Allograft reconstruction of the acetabulum during revision total hip arthroplasty: clinical, radiographic, and scintigraphic assessment of the results. J Bone Joint Surg Am. 1986;68:527–533.PubMed Trancik TM, Stulberg BN, Wilde AH, Feiglin DH. Allograft reconstruction of the acetabulum during revision total hip arthroplasty: clinical, radiographic, and scintigraphic assessment of the results. J Bone Joint Surg Am. 1986;68:527–533.PubMed
53.
go back to reference van der Donk S, Buma P, Slooff TJ, Gardeniers JW, Schreurs BW. Incorporation of morselized bone grafts: a study of 24 acetabular biopsy specimens. Clin Orthop Relat Res. 2002;396:131–141.PubMedCrossRef van der Donk S, Buma P, Slooff TJ, Gardeniers JW, Schreurs BW. Incorporation of morselized bone grafts: a study of 24 acetabular biopsy specimens. Clin Orthop Relat Res. 2002;396:131–141.PubMedCrossRef
54.
go back to reference van Haaren EH, Heyligers IC, Alexander FG, Wuisman PI. High rate of failure of impaction grafting in large acetabular defects. J Bone Joint Surg Br. 2007;89:296–300.PubMedCrossRef van Haaren EH, Heyligers IC, Alexander FG, Wuisman PI. High rate of failure of impaction grafting in large acetabular defects. J Bone Joint Surg Br. 2007;89:296–300.PubMedCrossRef
55.
go back to reference Welten ML, Schreurs BW, Buma P, Verdonschot N, Slooff TJ. Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: a 10- to 17-year follow-up study. J Arthroplasty. 2000;15:819–824.PubMedCrossRef Welten ML, Schreurs BW, Buma P, Verdonschot N, Slooff TJ. Acetabular reconstruction with impacted morcellized cancellous bone autograft and cemented primary total hip arthroplasty: a 10- to 17-year follow-up study. J Arthroplasty. 2000;15:819–824.PubMedCrossRef
56.
go back to reference Yoder SA, Brand RA, Pedersen DR, O’Gorman TW. Total hip acetabular component position affects component loosening rates. Clin Orthop Relat Res. 1988;228:79–87.PubMed Yoder SA, Brand RA, Pedersen DR, O’Gorman TW. Total hip acetabular component position affects component loosening rates. Clin Orthop Relat Res. 1988;228:79–87.PubMed
Metadata
Title
Acetabular Revision with Metal Mesh, Impaction Bone Grafting, and a Cemented Cup
Authors
Martín A. Buttaro, MD
Fernando Comba, MD
Rodolfo Pusso, MD
Francisco Piccaluga, MD
Publication date
01-10-2008
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 10/2008
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0442-x

Other articles of this Issue 10/2008

Clinical Orthopaedics and Related Research® 10/2008 Go to the issue

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Providing Outreach Continuing Education in Countries with Limited Resources

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Topics in Global Public Health

Symposium: ABJS/C.T. Brighton Workshop on Trauma in the Developing World

Orthochina.org: Case-based Orthopaedic Wiki Project in China