Inserting the femoral intramedullary alignment rod during total knee arthroplasty (TKA) can generate high intramedullary pressure, which increases the risk of intraoperative complications caused by fat embolism. Despite modifications to the surgical procedure, the best method to prevent this increase in pressure remains unknown. The reamer/irrigator/aspirator is a surgical instrument designed for use during femoral canal entry to increase the canal size and remove intramedullary fat and may prevent this pressure increase. We posed two hypotheses: (1) using the reamer/irrigator/aspirator system will result in lower maximum femoral intramedullary pressure than using only conventional instrumentation during the initial steps of a TKA; and (2) using the reamer/irrigator/aspirator system in the initial steps of TKA will result in a mean maximum intramedullary pressure less than 200 mm Hg. We simulated a TKA on 14 cadaveric femurs to compare the femoral intramedullary pressure using both methods. Considerable decreases in femoral intramedullary pressure of 86% proximally and 87% distally were obtained by using the reamer/irrigator/aspirator system. The mean maximum pressure using the reamer/irrigator/aspirator system was less than 200 mm Hg. Additional clinical studies are needed to confirm any reduction in complications using the reamer/irrigator/aspirator system.
Literature
1.
go back to reference Alfonso DT, Toussaint RJ, Alfonso BD, Strauss EJ, Steiger DT, Di Cesare PE. Nonsurgical complications after total hip and knee arthroplasty. Am J Orthop. 2006;35:503–510.PubMed Alfonso DT, Toussaint RJ, Alfonso BD, Strauss EJ, Steiger DT, Di Cesare PE. Nonsurgical complications after total hip and knee arthroplasty. Am J Orthop. 2006;35:503–510.PubMed
2.
go back to reference Amro RR, Nazarian DG, Norris RB, Kelly MP, Booth RE Jr. Suction instrumentation decreases intramedullary pressure, pulmonary embolism during total knee arthroplasty. Univ Penn Orthop J. 2001;14:55–59. Amro RR, Nazarian DG, Norris RB, Kelly MP, Booth RE Jr. Suction instrumentation decreases intramedullary pressure, pulmonary embolism during total knee arthroplasty. Univ Penn Orthop J. 2001;14:55–59.
3.
go back to reference Baker PL, Pazell JA, Peltier LF. Free fatty acids, catecholamines, and arterial hypoxia in patients with fat embolism. J Trauma. 1971;11:1026–1030.PubMedCrossRef Baker PL, Pazell JA, Peltier LF. Free fatty acids, catecholamines, and arterial hypoxia in patients with fat embolism. J Trauma. 1971;11:1026–1030.PubMedCrossRef
4.
go back to reference Caillouette JT, Anzel SH. Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res. 1990;251:198–199.PubMed Caillouette JT, Anzel SH. Fat embolism syndrome following the intramedullary alignment guide in total knee arthroplasty. Clin Orthop Relat Res. 1990;251:198–199.PubMed
5.
go back to reference Dobrjanski D, Saghir Z, Behdinan K, Zalzal P, de Beer J, Papini M. Intramedullary canal pressure distribution: an experimental parametric study. J Arthroplasty. 2007;22:417–427.PubMedCrossRef Dobrjanski D, Saghir Z, Behdinan K, Zalzal P, de Beer J, Papini M. Intramedullary canal pressure distribution: an experimental parametric study. J Arthroplasty. 2007;22:417–427.PubMedCrossRef
6.
go back to reference Fahmy NR, Chandler HP, Danylchuk K, Matta EB, Sunder N, Siliski JM. Blood-gas and circulatory changes during total knee replacement: role of the intramedullary alignment rod. J Bone Joint Surg Am. 1990;72:19–26.PubMed Fahmy NR, Chandler HP, Danylchuk K, Matta EB, Sunder N, Siliski JM. Blood-gas and circulatory changes during total knee replacement: role of the intramedullary alignment rod. J Bone Joint Surg Am. 1990;72:19–26.PubMed
7.
go back to reference Harwin SF. Recognizing anterior metaphyseal femoral bone loss during uncemented total hip arthroplasty: the skylight sign. Orthopedics. 2007;30:218–221.PubMed Harwin SF. Recognizing anterior metaphyseal femoral bone loss during uncemented total hip arthroplasty: the skylight sign. Orthopedics. 2007;30:218–221.PubMed
8.
go back to reference Hofmann S, Huemer G, Salzer M. Pathophysiology and management of the fat embolism syndrome. Anaesthesia. 1998;53(suppl 2):35–37.PubMed Hofmann S, Huemer G, Salzer M. Pathophysiology and management of the fat embolism syndrome. Anaesthesia. 1998;53(suppl 2):35–37.PubMed
9.
go back to reference Husebye EE, Lyberg T, Madsen JE, Eriksen M, Roise O. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur. Injury. 2006;37:935–940.PubMedCrossRef Husebye EE, Lyberg T, Madsen JE, Eriksen M, Roise O. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur. Injury. 2006;37:935–940.PubMedCrossRef
10.
go back to reference Joist A, Schult M, Ortmann C, Frerichmann U, Frebel T, Spiegel HU, Kropfl A, Redl H. Rinsing-suction reamer attenuates intramedullary pressure increase and fat intravasation in a sheep model. J Trauma. 2004;57:146–151.PubMedCrossRef Joist A, Schult M, Ortmann C, Frerichmann U, Frebel T, Spiegel HU, Kropfl A, Redl H. Rinsing-suction reamer attenuates intramedullary pressure increase and fat intravasation in a sheep model. J Trauma. 2004;57:146–151.PubMedCrossRef
11.
go back to reference Kim YH. Incidence of fat embolism syndrome after cemented or cementless bilateral simultaneous and unilateral total knee arthroplasty. J Arthroplasty. 2001;16:730–739.PubMedCrossRef Kim YH. Incidence of fat embolism syndrome after cemented or cementless bilateral simultaneous and unilateral total knee arthroplasty. J Arthroplasty. 2001;16:730–739.PubMedCrossRef
12.
go back to reference Koessler MJ, Fabiani R, Hamer H, Pitto RP. The clinical relevance of embolic events detected by trasesophageal echocardiography during cemented total hip arthroplsaty: a randomized clinical trial. Anesth Analg. 2001;92:49–55.PubMedCrossRef Koessler MJ, Fabiani R, Hamer H, Pitto RP. The clinical relevance of embolic events detected by trasesophageal echocardiography during cemented total hip arthroplsaty: a randomized clinical trial. Anesth Analg. 2001;92:49–55.PubMedCrossRef
13.
go back to reference Martin R, Leighton RK, Petrie D, Ikejiani C, Smyth B. Effect of proximal and distal venting during intramedullary nailing. Clin Orthop Relat Res. 1996;332:80–89.PubMedCrossRef Martin R, Leighton RK, Petrie D, Ikejiani C, Smyth B. Effect of proximal and distal venting during intramedullary nailing. Clin Orthop Relat Res. 1996;332:80–89.PubMedCrossRef
14.
go back to reference Mousavi M, David R, Ehteshami J, Pajenda G, Vecsei V. Pressure changes during reaming with different parameters and reamer design. Clin Orthop Relat Res. 2000;373:295–303.PubMedCrossRef Mousavi M, David R, Ehteshami J, Pajenda G, Vecsei V. Pressure changes during reaming with different parameters and reamer design. Clin Orthop Relat Res. 2000;373:295–303.PubMedCrossRef
15.
go back to reference Mueller CA, Rahn BA. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming. J Trauma. 2003;55:495–503.PubMedCrossRef Mueller CA, Rahn BA. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming. J Trauma. 2003;55:495–503.PubMedCrossRef
16.
go back to reference Orsini EC, Byrick RJ, Mullen JB, Kay JC, Waddell JP. Cardiopulmonary function and pulmonary microemboli during arthroplasty using cemented or non-cemented components. J Bone Joint Surg Am. 1987;69:822–832.PubMed Orsini EC, Byrick RJ, Mullen JB, Kay JC, Waddell JP. Cardiopulmonary function and pulmonary microemboli during arthroplasty using cemented or non-cemented components. J Bone Joint Surg Am. 1987;69:822–832.PubMed
17.
go back to reference Pape HC, Hildebrand F, Krettek C, Green J, Giannoudis PV. Experimental background: review of animal studies. Injury. 2006;37(suppl 4):S25–S38.PubMedCrossRef Pape HC, Hildebrand F, Krettek C, Green J, Giannoudis PV. Experimental background: review of animal studies. Injury. 2006;37(suppl 4):S25–S38.PubMedCrossRef
18.
go back to reference Pitto RP, Hamer H, Fabiani R, Radespiel-Troeger M, Koessler M. Prophylaxis against fat and bone-marrow embolism during total hip arthroplasty reduces the incidence of postoperative deep-vein thrombosis: a controlled, randomized clinical trial. J Bone Joint Surg Am. 2002;84:39–48.PubMed Pitto RP, Hamer H, Fabiani R, Radespiel-Troeger M, Koessler M. Prophylaxis against fat and bone-marrow embolism during total hip arthroplasty reduces the incidence of postoperative deep-vein thrombosis: a controlled, randomized clinical trial. J Bone Joint Surg Am. 2002;84:39–48.PubMed
19.
go back to reference Ries MD, Rauscher LA, Hoskins S, Lott D, Richman JA, Lynch F Jr. Intramedullary pressure and pulmonary function during total knee arthroplasty. Clin Orthop Relat Res. 1998;356:154–160.PubMedCrossRef Ries MD, Rauscher LA, Hoskins S, Lott D, Richman JA, Lynch F Jr. Intramedullary pressure and pulmonary function during total knee arthroplasty. Clin Orthop Relat Res. 1998;356:154–160.PubMedCrossRef
21.
go back to reference Wenda K, Runkel M, Degreif J, Ritter G. Pathogenesis and clinical relevance of bone marrow embolism in medullary nailing: demonstrated by intraoperative echocardiography. Injury. 1993;24(suppl 3):S73–S81.PubMedCrossRef Wenda K, Runkel M, Degreif J, Ritter G. Pathogenesis and clinical relevance of bone marrow embolism in medullary nailing: demonstrated by intraoperative echocardiography. Injury. 1993;24(suppl 3):S73–S81.PubMedCrossRef
Metadata
Title
The Reamer/Irrigator/Aspirator Reduces Femoral Canal Pressure in Simulated TKA
Authors
Cornel C. Van Gorp, MD
James V. Falk
Stanley J. Kmiec Jr
Robert A. Siston, PhD
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 3/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0258-8

Other articles of this Issue 3/2009

Clinical Orthopaedics and Related Research® 3/2009 Go to the issue

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

Arthroscopic Femoroplasty in the Management of Cam-type Femoroacetabular Impingement

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

Capital Realignment for Moderate and Severe SCFE Using a Modified Dunn Procedure

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

The Concept of Femoroacetabular Impingement: Current Status and Future Perspectives

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

Radiographic Evaluation of the Hip has Limited Reliability