Skip to main content
Top
Published in: Strategies in Trauma and Limb Reconstruction 1/2013

Open Access 01-04-2013 | Original Article

Distal tibial hypertrophic nonunion with deformity: treatment by fixator-assisted acute deformity correction and LCP fixation

Authors: Mahmoud A. El-Rosasy, Sameh A. El-Sallakh

Published in: Strategies in Trauma and Limb Reconstruction | Issue 1/2013

Login to get access

Abstract

Distal tibial hypertrophic nonunion with angular deformity has been successfully treated by circular external fixator. The inconvenience of the bulky external fixator and frequent pin tract infection would not be accepted in certain cases. This study included thirteen patients (mean age 39 years) with angular deformity of the distal dia-/metaphyseal tibial shaft. Five patients were originally treated by interlocking nail, three were treated by plate and screws fixation, four treated conservatively and one had deformity secondary to fracture of a lengthening regenerate. All patients were treated by osteotomy and acute correction of the deformity using temporary unilateral fixator and internal fixation by a locking compression plate (LCP). The external fixator was removed at the end of surgery. The results were evaluated both clinically and radiologically. All osteotomies healed within 3 (2–4) months. All patients were able to work within an average of 2.3 months. The function of the upper ankle joint was unrestricted in twelve cases, and in 1 case there was a mild functional deficit. The mean follow-up was 60 months (24–120). The frontal plane alignment parameters (the mechanical axis deviation, the lateral distal tibial angle and the medial proximal tibial angle) and the sagittal alignment parameters (the posterior proximal tibial angle and the anterior distal tibial angle) were within normal values postoperatively. No cases of deep infection or failure of fixation were encountered. Acute correction of distal tibial shaft hypertrophic nonunion with deformity and LCP fixation is a reliable option in well-selected cases.
Literature
1.
go back to reference Catagni MA, Guerreschi F, Holman JA, Cattaneo R (1994) Distraction osteogenesis in the treatment of stiff hypertrophic nonunions using the Ilizarov apparatus. Clin Orthop Relat Res 301:159–163PubMed Catagni MA, Guerreschi F, Holman JA, Cattaneo R (1994) Distraction osteogenesis in the treatment of stiff hypertrophic nonunions using the Ilizarov apparatus. Clin Orthop Relat Res 301:159–163PubMed
2.
go back to reference Saleh M, Royston S (1996) Management of nonunion of fractures by distraction with correction of angulation and shortening. J Bone Joint Surg Br 78(1):105–109PubMed Saleh M, Royston S (1996) Management of nonunion of fractures by distraction with correction of angulation and shortening. J Bone Joint Surg Br 78(1):105–109PubMed
3.
go back to reference McKee MD, Yoo D, Schemitsch EH (1998) Health status after Ilizarov reconstruction of post-traumatic lower limb deformity. J Bone Joint Surg Br 80:360–364PubMedCrossRef McKee MD, Yoo D, Schemitsch EH (1998) Health status after Ilizarov reconstruction of post-traumatic lower limb deformity. J Bone Joint Surg Br 80:360–364PubMedCrossRef
4.
go back to reference Sanders DW, Galpin RD, Hosseini M, MacLeod MD (2002) Morbidity resulting from the treatment of tibial nonunion with the Ilizarov frame. Can J Surg 45(3):196–200PubMedPubMedCentral Sanders DW, Galpin RD, Hosseini M, MacLeod MD (2002) Morbidity resulting from the treatment of tibial nonunion with the Ilizarov frame. Can J Surg 45(3):196–200PubMedPubMedCentral
5.
go back to reference Janssen KW, Biert J, van Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31(5):709–714PubMedPubMedCentralCrossRef Janssen KW, Biert J, van Kampen A (2007) Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients. Int Orthop 31(5):709–714PubMedPubMedCentralCrossRef
6.
go back to reference Helfet DL, Jupiter JB, Gasser S (1992) Indirect reduction and tension-band plating of tibial non-union with deformity. J Bone Joint Surg Am 74(9):1286–1297PubMed Helfet DL, Jupiter JB, Gasser S (1992) Indirect reduction and tension-band plating of tibial non-union with deformity. J Bone Joint Surg Am 74(9):1286–1297PubMed
7.
go back to reference Babhulkar S, Pande K, Babhulkar S (2005) Nonunion of the diaphysis of long bones. Clin Orthop Relat Res 431:50–56PubMedCrossRef Babhulkar S, Pande K, Babhulkar S (2005) Nonunion of the diaphysis of long bones. Clin Orthop Relat Res 431:50–56PubMedCrossRef
8.
go back to reference Phieffer LS, Goulet JA (2006) Delayed unions of the tibia. J Bone Joint Surg Am 88(1):206–216PubMed Phieffer LS, Goulet JA (2006) Delayed unions of the tibia. J Bone Joint Surg Am 88(1):206–216PubMed
9.
go back to reference Richmond J, Colleran K, Borens O, Kloen P, Helfet DL (2004) Nonunions of the distal tibia treated by reamed intramedullary nailing. J Orthop Trauma 18(9):603–610PubMedCrossRef Richmond J, Colleran K, Borens O, Kloen P, Helfet DL (2004) Nonunions of the distal tibia treated by reamed intramedullary nailing. J Orthop Trauma 18(9):603–610PubMedCrossRef
10.
go back to reference Zelle BA, Bhandari M, Espiritu M, Koval KJ, Evidence-Based Orthopaedic Trauma Working Group (2006) Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 20(1):76–79PubMedCrossRef Zelle BA, Bhandari M, Espiritu M, Koval KJ, Evidence-Based Orthopaedic Trauma Working Group (2006) Treatment of distal tibia fractures without articular involvement: a systematic review of 1125 fractures. J Orthop Trauma 20(1):76–79PubMedCrossRef
11.
go back to reference Haidukewych GJ, Ricci W (2008) Locked plating in orthopaedic trauma: a clinical update. J Am Acad Orthop Surg 16(6):347–355PubMed Haidukewych GJ, Ricci W (2008) Locked plating in orthopaedic trauma: a clinical update. J Am Acad Orthop Surg 16(6):347–355PubMed
12.
go back to reference Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of uniapical angular deformities of the tibia or femur. Clin Orthop Relat Res 280:48–64PubMed Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of uniapical angular deformities of the tibia or femur. Clin Orthop Relat Res 280:48–64PubMed
13.
go back to reference Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed Paley D, Tetsworth K (1992) Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin Orthop Relat Res 280:65–71PubMed
14.
go back to reference El-Rosasy MA (2007) Acute shortening and re-lengthening in the management of bone and soft-tissue loss in complicated fractures of the tibia. J Bone Joint Surg Br 89(1):80–88PubMedCrossRef El-Rosasy MA (2007) Acute shortening and re-lengthening in the management of bone and soft-tissue loss in complicated fractures of the tibia. J Bone Joint Surg Br 89(1):80–88PubMedCrossRef
15.
go back to reference Probe RA (2003) Lower extremity angular malunion: evaluation and surgical correction. J Am Acad Orthop Surg 11(5):302–311PubMed Probe RA (2003) Lower extremity angular malunion: evaluation and surgical correction. J Am Acad Orthop Surg 11(5):302–311PubMed
16.
go back to reference Gupta RK, Rohilla RK, Sangwan K, Singh V, Walia S (2010) Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients. Int Orthop 34(8):1285–1290 Epub 2009 Oct 10PubMedPubMedCentralCrossRef Gupta RK, Rohilla RK, Sangwan K, Singh V, Walia S (2010) Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients. Int Orthop 34(8):1285–1290 Epub 2009 Oct 10PubMedPubMedCentralCrossRef
Metadata
Title
Distal tibial hypertrophic nonunion with deformity: treatment by fixator-assisted acute deformity correction and LCP fixation
Authors
Mahmoud A. El-Rosasy
Sameh A. El-Sallakh
Publication date
01-04-2013
Publisher
Springer Milan
Published in
Strategies in Trauma and Limb Reconstruction / Issue 1/2013
Print ISSN: 1828-8936
Electronic ISSN: 1828-8928
DOI
https://doi.org/10.1007/s11751-012-0150-7

Other articles of this Issue 1/2013

Strategies in Trauma and Limb Reconstruction 1/2013 Go to the issue