Skip to main content
Top
Published in: General Thoracic and Cardiovascular Surgery 4/2014

01-04-2014 | Current Topics Review Article

The use of surgical glue in acute type A aortic dissection

Authors: Shinichi Suzuki, Munetaka Masuda, Kiyotaka Imoto

Published in: General Thoracic and Cardiovascular Surgery | Issue 4/2014

Login to get access

Abstract

Acute type A aortic dissection (AAAD) remains a lethal disease. With advances in operative methods and perioperative management, surgical outcomes continue to improve, but in-hospital mortality still ranges from 10 to 30 % in most series. The surgical technique of choice for aortic root repair remains controversial. Surgical glue created a breakthrough in surgery for acute aortic dissection. We review the surgical techniques with the use of surgical glue for AAAD.
Literature
1.
go back to reference Hirst AE Jr, Johns VJ Jr, Kime SW Jr. Dissecting aneurysm of the aorta: a review of 505 cases. Medicine (Baltimore). 1958;37:217–79.CrossRef Hirst AE Jr, Johns VJ Jr, Kime SW Jr. Dissecting aneurysm of the aorta: a review of 505 cases. Medicine (Baltimore). 1958;37:217–79.CrossRef
2.
go back to reference Shennan T. Dissecting aneurysm. Medical Research Council Special Report, vol 193. London: His Majesty’s Stationery Office; 1934. Shennan T. Dissecting aneurysm. Medical Research Council Special Report, vol 193. London: His Majesty’s Stationery Office; 1934.
3.
go back to reference Anagnostopoulos CE, Prabhakar MJS, Kittle CF. Aortic dissections and dissecting aneurysms. Am J Cardiol. 1972;30:263–73.PubMedCrossRef Anagnostopoulos CE, Prabhakar MJS, Kittle CF. Aortic dissections and dissecting aneurysms. Am J Cardiol. 1972;30:263–73.PubMedCrossRef
4.
go back to reference Lauterbach SR, Cambria RP, Brewster DC, Gertler JP, Lamuraglia GM, Isselbacher EM, et al. Contemporary management of aortic branch compromise resulting from acute aortic dissection. J Vasc Surgery. 2001;33:1185–92.CrossRef Lauterbach SR, Cambria RP, Brewster DC, Gertler JP, Lamuraglia GM, Isselbacher EM, et al. Contemporary management of aortic branch compromise resulting from acute aortic dissection. J Vasc Surgery. 2001;33:1185–92.CrossRef
5.
go back to reference DeBakey MD, Henly WS, Cooley DA, Morris GC, Crawford ES, Beakk AC. Surgical management of dissecting aneurysms of the aorta. J Thorac Cardiovasc Surg. 1965;49:130–49.PubMed DeBakey MD, Henly WS, Cooley DA, Morris GC, Crawford ES, Beakk AC. Surgical management of dissecting aneurysms of the aorta. J Thorac Cardiovasc Surg. 1965;49:130–49.PubMed
6.
go back to reference DeBakey MD, McCollum CH, Crawford ES, Morris GC, Howell J, Noon GP, et al. Dissection and dissecting aneurysms of the aorta. Twenty-year follow-up of five hundred twenty-seven patients treated surgically. Surgery. 1982;92:1118–34.PubMed DeBakey MD, McCollum CH, Crawford ES, Morris GC, Howell J, Noon GP, et al. Dissection and dissecting aneurysms of the aorta. Twenty-year follow-up of five hundred twenty-seven patients treated surgically. Surgery. 1982;92:1118–34.PubMed
7.
go back to reference Meng RL, Najafi H, Javid H, Hunter JA, Goldin MD. Acute ascending aortic dissection: surgical management. Circulation. 1981; 64(Pt2):II231–4. Meng RL, Najafi H, Javid H, Hunter JA, Goldin MD. Acute ascending aortic dissection: surgical management. Circulation. 1981; 64(Pt2):II231–4.
8.
go back to reference DeSanctis RW, Doroghazi RM, Austen WG, Buckley MJ. Aortic dissection. N Engl J Med. 1987;317:1060–7.PubMedCrossRef DeSanctis RW, Doroghazi RM, Austen WG, Buckley MJ. Aortic dissection. N Engl J Med. 1987;317:1060–7.PubMedCrossRef
9.
go back to reference Miller DC, Stinson EB, Oyer PE, Rossiter SJ, Reitz BA, Griepp RB, et al. Operative treatment of aortic dissections. Experience with 125 patients over a sixteen-years period. J Thorac Cardiovasc Surg. 1979;78:365–82.PubMed Miller DC, Stinson EB, Oyer PE, Rossiter SJ, Reitz BA, Griepp RB, et al. Operative treatment of aortic dissections. Experience with 125 patients over a sixteen-years period. J Thorac Cardiovasc Surg. 1979;78:365–82.PubMed
10.
go back to reference Miller DC, Mitchell RS, Oyer PE, Stinson EB, Jamieson SW, Shumway NE. Independent determinants of operative mortality for patients with aortic dissections. Circulation. 1984;70(Pt 2):I 153–64. Miller DC, Mitchell RS, Oyer PE, Stinson EB, Jamieson SW, Shumway NE. Independent determinants of operative mortality for patients with aortic dissections. Circulation. 1984;70(Pt 2):I 153–64.
11.
go back to reference Fann JI, Glower DD, Miller DC, Yun KL, Rankin JS, White WD, et al. Preservation of aortic valve in type A aortic dissection complicated by aortic regurgitation. J Thorac Cardiovasc Surg. 1991;102:62–75.PubMed Fann JI, Glower DD, Miller DC, Yun KL, Rankin JS, White WD, et al. Preservation of aortic valve in type A aortic dissection complicated by aortic regurgitation. J Thorac Cardiovasc Surg. 1991;102:62–75.PubMed
12.
go back to reference Mazzucotelli JP, Deleuze PH, Baufreton C, Duval AM, Hillion ML, Loisance DY, et al. Preservation of the aortic valve in acute aortic dissection: long-term echocardiographic assessment and clinical outcome. Ann Thorac Surg. 1993;55:1513–7.PubMedCrossRef Mazzucotelli JP, Deleuze PH, Baufreton C, Duval AM, Hillion ML, Loisance DY, et al. Preservation of the aortic valve in acute aortic dissection: long-term echocardiographic assessment and clinical outcome. Ann Thorac Surg. 1993;55:1513–7.PubMedCrossRef
13.
go back to reference Von Segesser LK, Lorenzetti E, Lachat M, Niederhäuser U, Schönbeck M, Vogt PR, et al. Aortic valve preservation in type A aortic dissection: is it sound? J Thorac Cardiovasc Surg. 1996;111:381–91.CrossRef Von Segesser LK, Lorenzetti E, Lachat M, Niederhäuser U, Schönbeck M, Vogt PR, et al. Aortic valve preservation in type A aortic dissection: is it sound? J Thorac Cardiovasc Surg. 1996;111:381–91.CrossRef
14.
go back to reference Collins JJ Jr, Cohn LH. Reconstruction of the aortic valve: correcting valve incompetence due to acute dissecting aneurysm. Arch Surg. 1973;106:35–7.PubMedCrossRef Collins JJ Jr, Cohn LH. Reconstruction of the aortic valve: correcting valve incompetence due to acute dissecting aneurysm. Arch Surg. 1973;106:35–7.PubMedCrossRef
15.
go back to reference Kouchoukos NT, Marshall WG, Wedige-Stxcher TA. Eleven-year experience with composite graft replacement of the ascending aorta and aorta valve. J Thorac Cardiovasc Surg. 1986;92:691–705.PubMed Kouchoukos NT, Marshall WG, Wedige-Stxcher TA. Eleven-year experience with composite graft replacement of the ascending aorta and aorta valve. J Thorac Cardiovasc Surg. 1986;92:691–705.PubMed
16.
go back to reference Braunwald NS, Gay W, Tatooles CJ. Evaluation of cross-linked as a tissue adhesive and hemostatic agent. Experimental study. Surgery. 1966;59:1024–30.PubMed Braunwald NS, Gay W, Tatooles CJ. Evaluation of cross-linked as a tissue adhesive and hemostatic agent. Experimental study. Surgery. 1966;59:1024–30.PubMed
17.
go back to reference Guilmet D, Bachet J, Goudot B, Laurian C, Gigou F, Bical O, et al. Use of biological glue in acute aortic dissection. Preliminary clinical results with a new surgical technique. J Thorac Cardiovasc Surg. 1979;77:516–21.PubMed Guilmet D, Bachet J, Goudot B, Laurian C, Gigou F, Bical O, et al. Use of biological glue in acute aortic dissection. Preliminary clinical results with a new surgical technique. J Thorac Cardiovasc Surg. 1979;77:516–21.PubMed
18.
go back to reference Bachet J, Gigou F, Laurian C, Bical O, Goudot B, Guilmet D. Four-year clinical experience with the gelatine–resorcine–formol glue in acute aortic dissection. J Thorac Cardiovasc Surg. 1982;83:212–7.PubMed Bachet J, Gigou F, Laurian C, Bical O, Goudot B, Guilmet D. Four-year clinical experience with the gelatine–resorcine–formol glue in acute aortic dissection. J Thorac Cardiovasc Surg. 1982;83:212–7.PubMed
19.
go back to reference Bachet J, Goudot B, Dreyfus GD, Brodaty D, Dubois C, Delentdecker P, et al. Surgery for acute type A aortic dissection: the hospital Foch experience (1977–1998). Ann Thorac Surg. 1999;67:2006–9.PubMedCrossRef Bachet J, Goudot B, Dreyfus GD, Brodaty D, Dubois C, Delentdecker P, et al. Surgery for acute type A aortic dissection: the hospital Foch experience (1977–1998). Ann Thorac Surg. 1999;67:2006–9.PubMedCrossRef
20.
go back to reference Weinschelbaum EE, Schamun C, Caranutti V, Tacchi H, Cors J, Favaloro RG. Surgical treatment of acute type A dissecting aneurysm with preservation of the native aortic valve and use of biologic glue. Follow-up to 6 years. J Thorac Cardiovasc Surg. 1992;103:369–74.PubMed Weinschelbaum EE, Schamun C, Caranutti V, Tacchi H, Cors J, Favaloro RG. Surgical treatment of acute type A dissecting aneurysm with preservation of the native aortic valve and use of biologic glue. Follow-up to 6 years. J Thorac Cardiovasc Surg. 1992;103:369–74.PubMed
21.
go back to reference Westaby S, Katsumata T, Freitas E. Aortic valve conservation in acute type A dissection. Ann Thorac Surg. 1997;64:1108–12.PubMedCrossRef Westaby S, Katsumata T, Freitas E. Aortic valve conservation in acute type A dissection. Ann Thorac Surg. 1997;64:1108–12.PubMedCrossRef
22.
go back to reference Neiderhäuser U, Künzli A, Seifert B, Schmidli J, Lachat M, Zünd G, et al. Conservative treatment of the aortic root in acute type A dissection. Eur J Cardiothorac Surg. 1999;15:557–63.CrossRef Neiderhäuser U, Künzli A, Seifert B, Schmidli J, Lachat M, Zünd G, et al. Conservative treatment of the aortic root in acute type A dissection. Eur J Cardiothorac Surg. 1999;15:557–63.CrossRef
23.
go back to reference Casselman FP, Tan ES, Vermeulen FE, Kelder JC, Morshuis WJ, Schepens MA. Durability of aortic valve preservation and root reconstruction in acute type A aortic dissection. Ann Thorac Surg. 2000;70:1227–33.PubMedCrossRef Casselman FP, Tan ES, Vermeulen FE, Kelder JC, Morshuis WJ, Schepens MA. Durability of aortic valve preservation and root reconstruction in acute type A aortic dissection. Ann Thorac Surg. 2000;70:1227–33.PubMedCrossRef
24.
go back to reference Kirsch M, Soustelle C, Houel R, Hillion ML, Loisance D. Risk factor analysis for proximal and distal reoperations after surgery for acute type A aortic dissection. J Thorac Cardiovasc Surg. 2002;123:318–25.PubMedCrossRef Kirsch M, Soustelle C, Houel R, Hillion ML, Loisance D. Risk factor analysis for proximal and distal reoperations after surgery for acute type A aortic dissection. J Thorac Cardiovasc Surg. 2002;123:318–25.PubMedCrossRef
25.
go back to reference Hata M, Shiono M, Sezai A, Lida M, Negishi N, Sezai Y. Type A acute aortic dissection: immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue. Ann Thorac Surg. 2004;78:853–7.PubMedCrossRef Hata M, Shiono M, Sezai A, Lida M, Negishi N, Sezai Y. Type A acute aortic dissection: immediate and mid-term results of emergency aortic replacement with the aid of gelatin resorcin formalin glue. Ann Thorac Surg. 2004;78:853–7.PubMedCrossRef
26.
go back to reference Suzuki S, Imoto K, Uchida K, Takanashi Y. Aortic root necrosis after surgical treatment using. Gelatin–resorcinol–formaldehyde (GRF) glue in patients with acute type A aortic dissection. Ann Thorac Cardiovasc Surg. 2006;12:333–40.PubMed Suzuki S, Imoto K, Uchida K, Takanashi Y. Aortic root necrosis after surgical treatment using. Gelatin–resorcinol–formaldehyde (GRF) glue in patients with acute type A aortic dissection. Ann Thorac Cardiovasc Surg. 2006;12:333–40.PubMed
27.
go back to reference Fukunaga S, Karck M, Harringer W, Cremer J, Rhein C, Haverich A. The use of gelatin–resorcin–formalin glue in acute aortic dissection type A. Eur J Cardiothorac Surg. 1999;15:564–70.PubMedCrossRef Fukunaga S, Karck M, Harringer W, Cremer J, Rhein C, Haverich A. The use of gelatin–resorcin–formalin glue in acute aortic dissection type A. Eur J Cardiothorac Surg. 1999;15:564–70.PubMedCrossRef
28.
go back to reference Bingley JA, Gradner MAH, Stanford EG, Mau TK, Pohlner PG, Tam RKW, et al. Late complications of tissue glues in aortic surgery. Ann Thorac Surg. 2000;69:1764–8.PubMedCrossRef Bingley JA, Gradner MAH, Stanford EG, Mau TK, Pohlner PG, Tam RKW, et al. Late complications of tissue glues in aortic surgery. Ann Thorac Surg. 2000;69:1764–8.PubMedCrossRef
29.
go back to reference Kazui T, Washiyama N, Bashar AHM, Terada H, Suzuki K, Yamashita K, et al. Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root. Ann Thorac Surg. 2001;72:509–14.PubMedCrossRef Kazui T, Washiyama N, Bashar AHM, Terada H, Suzuki K, Yamashita K, et al. Role of biologic glue repair of proximal aortic dissection in the development of early and midterm redissection of the aortic root. Ann Thorac Surg. 2001;72:509–14.PubMedCrossRef
30.
go back to reference Suehiro K, Hata T, Yoshitaka H, Tsushima Y, Matsumoto M, Hamanaka S, et al. Late aortic root redissection following surgical treatment for acute type A aortic dissection using gelatin–resorcin–formalin Glue. Jpn J Thorac Cardiovasc Surg. 2002;50:195–200.PubMedCrossRef Suehiro K, Hata T, Yoshitaka H, Tsushima Y, Matsumoto M, Hamanaka S, et al. Late aortic root redissection following surgical treatment for acute type A aortic dissection using gelatin–resorcin–formalin Glue. Jpn J Thorac Cardiovasc Surg. 2002;50:195–200.PubMedCrossRef
31.
go back to reference Von Oppell UO, Karani Z, Brooks A, Brink J. Dissected aortic sinuses repaired with gelatin–resorcin–formaldehyde (GRF) glue are not stable on follow up. J Heart Valve Dis. 2002;11:249–57. Von Oppell UO, Karani Z, Brooks A, Brink J. Dissected aortic sinuses repaired with gelatin–resorcin–formaldehyde (GRF) glue are not stable on follow up. J Heart Valve Dis. 2002;11:249–57.
32.
go back to reference Imoto K. Recent status of gelatin–resorcin–formalin glue for acute type A aortic dissection. Gen Thorac Cardiovasc Surg. 2011;59:313–4.PubMedCrossRef Imoto K. Recent status of gelatin–resorcin–formalin glue for acute type A aortic dissection. Gen Thorac Cardiovasc Surg. 2011;59:313–4.PubMedCrossRef
33.
go back to reference Ennker J, Ennker IC, Schoon D, Schoon HA, Dorge S, Meissler M, et al. The impact of gelatin–resorcinol glue on aortic tissue: a histomorphologic evaluation. J Vasc Surg. 1994;20:34–43.PubMedCrossRef Ennker J, Ennker IC, Schoon D, Schoon HA, Dorge S, Meissler M, et al. The impact of gelatin–resorcinol glue on aortic tissue: a histomorphologic evaluation. J Vasc Surg. 1994;20:34–43.PubMedCrossRef
34.
go back to reference Bachet J, Guilmet D. The use of biological glue in aortic surgery. Cardiol Clin. 1999; 17:779–96, ix–x. Bachet J, Guilmet D. The use of biological glue in aortic surgery. Cardiol Clin. 1999; 17:779–96, ix–x.
35.
go back to reference Kunihara T, Iizuka K, Sasaki S, Shiiya N, Sata F, Matsui Y. Optimal proportions of gelatin–resorcin–formalin components in aortic surgery. Eur J Cardiothorac Surg. 2009;36:962–6.PubMedCrossRef Kunihara T, Iizuka K, Sasaki S, Shiiya N, Sata F, Matsui Y. Optimal proportions of gelatin–resorcin–formalin components in aortic surgery. Eur J Cardiothorac Surg. 2009;36:962–6.PubMedCrossRef
36.
go back to reference Yamanaka K, Hori Y, Ikarashi J, Kusuhara T, Nakatuska D, Hirose K, et al. Durability of aortic valve preservation with root reconstruction for acute type A aortic dissection. Eur J Cardiothorac Surg. 2012; 41:e32–6. Yamanaka K, Hori Y, Ikarashi J, Kusuhara T, Nakatuska D, Hirose K, et al. Durability of aortic valve preservation with root reconstruction for acute type A aortic dissection. Eur J Cardiothorac Surg. 2012; 41:e32–6.
37.
go back to reference Concistrè G, Casali G, Santaniello E, Montalto A, Fiorani B, Dell’Aquila A, et al. Reoperation after surgical correction of acute type A aortic dissection: risk factor analysis. Ann Thorac Surg. 2012;93:450–6.PubMedCrossRef Concistrè G, Casali G, Santaniello E, Montalto A, Fiorani B, Dell’Aquila A, et al. Reoperation after surgical correction of acute type A aortic dissection: risk factor analysis. Ann Thorac Surg. 2012;93:450–6.PubMedCrossRef
38.
go back to reference Karck M. The glue crisis in surgery of acute aortic dissection type A is ongoing. Eur J Cardiothorac Surg. 2012;41:e36–7.PubMedCrossRef Karck M. The glue crisis in surgery of acute aortic dissection type A is ongoing. Eur J Cardiothorac Surg. 2012;41:e36–7.PubMedCrossRef
39.
go back to reference Izutani H, Shibukawa T, Kawamoto J, Ishibashi K, Nishikawa D. Devastating late complication for repair of type A acute aortic dissection with usage of gelatin–resorcinol–formalin glue. Interact Cardiovasc Thorac Surg. 2007;6:240–2.PubMedCrossRef Izutani H, Shibukawa T, Kawamoto J, Ishibashi K, Nishikawa D. Devastating late complication for repair of type A acute aortic dissection with usage of gelatin–resorcinol–formalin glue. Interact Cardiovasc Thorac Surg. 2007;6:240–2.PubMedCrossRef
40.
go back to reference Hata H, Takano H, Matsumiya G, Fukushima N, Kawaguchi N, Sawa Y. Late complications of gelatin–resorcin–formalin glue in the repair of acute type A aortic dissection. Ann Thorac Surg. 2007;83:1621–7.PubMedCrossRef Hata H, Takano H, Matsumiya G, Fukushima N, Kawaguchi N, Sawa Y. Late complications of gelatin–resorcin–formalin glue in the repair of acute type A aortic dissection. Ann Thorac Surg. 2007;83:1621–7.PubMedCrossRef
41.
go back to reference Séguin JR, Frapier JM, Colson P, Chaptal PA. Fibrin sealant improves surgical results of type A acute aortic dissections. Ann Thorac Surg. 1991;52:745–9.PubMedCrossRef Séguin JR, Frapier JM, Colson P, Chaptal PA. Fibrin sealant improves surgical results of type A acute aortic dissections. Ann Thorac Surg. 1991;52:745–9.PubMedCrossRef
42.
go back to reference Séguin JR, Picard E, Frapier JM, Chaptal PA. Aortic valve repair with fibrin glue for type A acute aortic dissection. Ann Thorac Surg. 1994;58:304–7.PubMedCrossRef Séguin JR, Picard E, Frapier JM, Chaptal PA. Aortic valve repair with fibrin glue for type A acute aortic dissection. Ann Thorac Surg. 1994;58:304–7.PubMedCrossRef
43.
go back to reference Suzuki S, Imoto K, Uchida K, Karube N. The use of fibrin glue and teflon felts for root reconstructions of acute type A aortic dissection. Presented at Aortic surgery symposium X. Apr, 2006 Suzuki S, Imoto K, Uchida K, Karube N. The use of fibrin glue and teflon felts for root reconstructions of acute type A aortic dissection. Presented at Aortic surgery symposium X. Apr, 2006
44.
go back to reference Suzuki S, Imoto K, Uchida K, Kobayashi K, Date K, Gouda M, et al. The usage of Fibrin glue and Teflon felts for root repair in the patients with acute type A aortic dissection. Presented at the 35th annual meeting of Japanese Society for Vascular Surgery, May 2007. Suzuki S, Imoto K, Uchida K, Kobayashi K, Date K, Gouda M, et al. The usage of Fibrin glue and Teflon felts for root repair in the patients with acute type A aortic dissection. Presented at the 35th annual meeting of Japanese Society for Vascular Surgery, May 2007.
45.
go back to reference Nakajima T, Kawasoe K, Izumoto H, Kataoka T, Kazui T. Effective use of fibrin glue for acute aortic dissection. Ann Thorac Surg. 2005;79:1793–4.PubMedCrossRef Nakajima T, Kawasoe K, Izumoto H, Kataoka T, Kazui T. Effective use of fibrin glue for acute aortic dissection. Ann Thorac Surg. 2005;79:1793–4.PubMedCrossRef
46.
go back to reference Nakajima T, Kawazoe K, Kataoka T, Kin H, Kazui T, Okabayashi H, et al. Midterm results of aortic repair using a fabric neomedia and fibrin glue for type A acute aortic dissection. Ann Thorac Surg. 2007;83:1615–20.PubMedCrossRef Nakajima T, Kawazoe K, Kataoka T, Kin H, Kazui T, Okabayashi H, et al. Midterm results of aortic repair using a fabric neomedia and fibrin glue for type A acute aortic dissection. Ann Thorac Surg. 2007;83:1615–20.PubMedCrossRef
47.
go back to reference Bavaria JE, Pochettino A, Brinster DR, Gorman RC, Wozniak T, Gardner TJ, et al. Prospective randomized study of BioGlue tissue adhesive during repair of acute type A aortic dissection. Presented at the American Association for Thoracic surgery, May 2001 Bavaria JE, Pochettino A, Brinster DR, Gorman RC, Wozniak T, Gardner TJ, et al. Prospective randomized study of BioGlue tissue adhesive during repair of acute type A aortic dissection. Presented at the American Association for Thoracic surgery, May 2001
48.
go back to reference Bavaria JE, Brinster DR, Gorman RC, Woo YJ, Gleason T, Pochettino A. Advances in the treatment of acute type A dissection: an integrated approach. Ann Thorac Surg. 2002;74:s1848–52.PubMedCrossRef Bavaria JE, Brinster DR, Gorman RC, Woo YJ, Gleason T, Pochettino A. Advances in the treatment of acute type A dissection: an integrated approach. Ann Thorac Surg. 2002;74:s1848–52.PubMedCrossRef
49.
go back to reference Coselli JS, Bavaria JE, Fehrenbacher J, Stowe CL, Macheer SK, Gundry SR. Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures. J Am Coll Surg. 2003;197:243–53.PubMedCrossRef Coselli JS, Bavaria JE, Fehrenbacher J, Stowe CL, Macheer SK, Gundry SR. Prospective randomized study of a protein-based tissue adhesive used as a hemostatic and structural adjunct in cardiac and vascular anastomotic repair procedures. J Am Coll Surg. 2003;197:243–53.PubMedCrossRef
50.
go back to reference Chao HH, Torchiana DF. BioGlue: albumin/glutaraldehyde sealant in cardiac surgery. J Card Surg. 2003;18:500–3.PubMedCrossRef Chao HH, Torchiana DF. BioGlue: albumin/glutaraldehyde sealant in cardiac surgery. J Card Surg. 2003;18:500–3.PubMedCrossRef
51.
go back to reference Raanani E, Georghiou GP, Kogan A, Wandwi B, Shapira Y, Vidne BA. ‘BioGlue’ for the repair of aortic insufficiency in acute aortic dissection. J Heart Valve Dis. 2004;13:734–7.PubMed Raanani E, Georghiou GP, Kogan A, Wandwi B, Shapira Y, Vidne BA. ‘BioGlue’ for the repair of aortic insufficiency in acute aortic dissection. J Heart Valve Dis. 2004;13:734–7.PubMed
52.
go back to reference Mitrev Z, Belostotskii V, Hristov N. Suture line reinforcement using suction-assisted bioglue application during surgery for acute aortic dissection. Interact Cardiovasc Thorac Surg. 2007;6:147–9.PubMedCrossRef Mitrev Z, Belostotskii V, Hristov N. Suture line reinforcement using suction-assisted bioglue application during surgery for acute aortic dissection. Interact Cardiovasc Thorac Surg. 2007;6:147–9.PubMedCrossRef
53.
go back to reference Zehr KJ. Use of bovine albumin-glutaraldehyde glue in cardiovascular surgery. Ann Thorac Surg. 2007;84:1048–52.PubMedCrossRef Zehr KJ. Use of bovine albumin-glutaraldehyde glue in cardiovascular surgery. Ann Thorac Surg. 2007;84:1048–52.PubMedCrossRef
54.
go back to reference Mejia R, Thomson DS. A new technique for repair of atrioventricular disruption complicating mitral valve replacement. Ann Thorac Surg. 2003;75:1973–4.PubMedCrossRef Mejia R, Thomson DS. A new technique for repair of atrioventricular disruption complicating mitral valve replacement. Ann Thorac Surg. 2003;75:1973–4.PubMedCrossRef
55.
go back to reference Masroor S, Schor J, Carrillo R, Williams DB. Endoventricular pocket repair of type I myocardial rupture after mitral valve replacement: a new technique using pericardial patch, Teflon felt, and BioGlue. Ann Thorac Surg. 2004;77:1439–41.PubMedCrossRef Masroor S, Schor J, Carrillo R, Williams DB. Endoventricular pocket repair of type I myocardial rupture after mitral valve replacement: a new technique using pericardial patch, Teflon felt, and BioGlue. Ann Thorac Surg. 2004;77:1439–41.PubMedCrossRef
56.
go back to reference Dunst KM, Antretter H, Bonatti J. Control of suture hole bleeding after aortic valve replacement by application of BioGlue during circulatory arrest. Int Heart J. 2005;46:175–9.PubMedCrossRef Dunst KM, Antretter H, Bonatti J. Control of suture hole bleeding after aortic valve replacement by application of BioGlue during circulatory arrest. Int Heart J. 2005;46:175–9.PubMedCrossRef
57.
go back to reference Leva C, Bruno PG, Gallorini C, Lazzarini I, Musazzi G, Vittonati L, et al. Complete myocardial revascularization and sutureless technique for left ventricular free wall rupture: clinical and echocardiographic results. Interact Cardiovasc Thorac Surg. 2006;5:408–12.PubMedCrossRef Leva C, Bruno PG, Gallorini C, Lazzarini I, Musazzi G, Vittonati L, et al. Complete myocardial revascularization and sutureless technique for left ventricular free wall rupture: clinical and echocardiographic results. Interact Cardiovasc Thorac Surg. 2006;5:408–12.PubMedCrossRef
58.
go back to reference Passage J, Jalali H, Tam RK, Harrocks S, O’Brien MF. BioGlue Surgical Adhesive—an appraisal of its indications in cardiac surgery. Ann Thorac Surg. 2002;74:432–7.PubMedCrossRef Passage J, Jalali H, Tam RK, Harrocks S, O’Brien MF. BioGlue Surgical Adhesive—an appraisal of its indications in cardiac surgery. Ann Thorac Surg. 2002;74:432–7.PubMedCrossRef
59.
go back to reference Bhamidipati CM, Coselli JS, Lemaire SA. BioGlue in 2011: what is its role in cardiac surgery? J Extra Corpor Technol. 2012;44:6–12. Bhamidipati CM, Coselli JS, Lemaire SA. BioGlue in 2011: what is its role in cardiac surgery? J Extra Corpor Technol. 2012;44:6–12.
60.
go back to reference Fehrenbacher JW, Siderys H. Use of BioGlue in aortic surgery: proper application techniques and results in 92 patients. Heart Surg Forum. 2006;9:E794–9.PubMedCrossRef Fehrenbacher JW, Siderys H. Use of BioGlue in aortic surgery: proper application techniques and results in 92 patients. Heart Surg Forum. 2006;9:E794–9.PubMedCrossRef
61.
go back to reference LeMaire SA, Ochoa LN, Conkin LD, Schmittling ZC, Ündar A, Clubb FJ Jr, et al. Nerve and conduction tissue injury caused by contact with BioGlue. J Surg Res. 2007;143:286–93.PubMedCrossRef LeMaire SA, Ochoa LN, Conkin LD, Schmittling ZC, Ündar A, Clubb FJ Jr, et al. Nerve and conduction tissue injury caused by contact with BioGlue. J Surg Res. 2007;143:286–93.PubMedCrossRef
62.
go back to reference LeMaire SA, Schmittling ZC, Coselli JS, Ündar A, Deady BA, Clubb FJ Jr, et al. BioGlue surgical adhesive impairs aortic growth and causes anastomotic strictures. Ann Thorac Surg. 2002;73:1500–6.PubMedCrossRef LeMaire SA, Schmittling ZC, Coselli JS, Ündar A, Deady BA, Clubb FJ Jr, et al. BioGlue surgical adhesive impairs aortic growth and causes anastomotic strictures. Ann Thorac Surg. 2002;73:1500–6.PubMedCrossRef
63.
go back to reference Erasmi AW, Sievers HH, Wolschläger C. Inflammatory response after BioGlue application. Ann Thorac Surg. 2002;73:1025–6.PubMedCrossRef Erasmi AW, Sievers HH, Wolschläger C. Inflammatory response after BioGlue application. Ann Thorac Surg. 2002;73:1025–6.PubMedCrossRef
64.
go back to reference Economopoulos GC, Dimitrakakis GK, Brountzos E, Kelekis DA. Superior vena cava stenosis: a delayed BioGlue complication. J Thorac Cardiovasc Surg. 2004;127:1919–21.CrossRef Economopoulos GC, Dimitrakakis GK, Brountzos E, Kelekis DA. Superior vena cava stenosis: a delayed BioGlue complication. J Thorac Cardiovasc Surg. 2004;127:1919–21.CrossRef
65.
go back to reference Podila SR, Szafranek A, Rathore AR, Balachandran S, Kulatilake NP. Thoracoscopic removal of pericardial foreign body. Ann Thorac Surg. 2006;82:1915.PubMedCrossRef Podila SR, Szafranek A, Rathore AR, Balachandran S, Kulatilake NP. Thoracoscopic removal of pericardial foreign body. Ann Thorac Surg. 2006;82:1915.PubMedCrossRef
66.
go back to reference Szafranek A, Podalia SR, Al-Khyatt W, Kulatilake EN. Aseptic mediastinal cyst caused by BioGlue 7 months after cardiac surgery. J Thorac Cardiovasc Surg. 2006;131:1202–3.PubMedCrossRef Szafranek A, Podalia SR, Al-Khyatt W, Kulatilake EN. Aseptic mediastinal cyst caused by BioGlue 7 months after cardiac surgery. J Thorac Cardiovasc Surg. 2006;131:1202–3.PubMedCrossRef
67.
go back to reference Cavolli R, Kaya K, Elamis AO. “Acute pseudo-pericardial tamponade”: the compression of the thoracal inferior vena cava- A case report. J Cardiothoracic Surg. 2009;4:9.CrossRef Cavolli R, Kaya K, Elamis AO. “Acute pseudo-pericardial tamponade”: the compression of the thoracal inferior vena cava- A case report. J Cardiothoracic Surg. 2009;4:9.CrossRef
68.
go back to reference Babin-Ebell J, Bougioukakis P, Urbanski P, Forehner S, Diegeler A. Foreign material reaction to BioGlue R as a possible cause of cardiac tamponade. Thorac Cardiovasc Surg. 2010;58:489–91.PubMedCrossRef Babin-Ebell J, Bougioukakis P, Urbanski P, Forehner S, Diegeler A. Foreign material reaction to BioGlue R as a possible cause of cardiac tamponade. Thorac Cardiovasc Surg. 2010;58:489–91.PubMedCrossRef
69.
go back to reference Almaeddine A, Alimov VK, Rousou JA, Freeman J. Aorto-pulmonary artery disruption following acute type A aortic dissection repair with the use of BioGlue R. 2012;27:371–3.**** Almaeddine A, Alimov VK, Rousou JA, Freeman J. Aorto-pulmonary artery disruption following acute type A aortic dissection repair with the use of BioGlue R. 2012;27:371–3.****
70.
go back to reference Modi A, Bull R, Tsang G, Karrne M. Ostial left coronary stenosis following aortic root construction with BioGlue. Interact Cardiovasc Thorac Surg. 2011;13:243–5.PubMedCrossRef Modi A, Bull R, Tsang G, Karrne M. Ostial left coronary stenosis following aortic root construction with BioGlue. Interact Cardiovasc Thorac Surg. 2011;13:243–5.PubMedCrossRef
71.
go back to reference Carrell TW, Smith A, Burnand KG. Experimental techniques and models in the study of the development and treatment of abdominal aortic aneurysm. Br J Surg. 1999;86:305–12.PubMedCrossRef Carrell TW, Smith A, Burnand KG. Experimental techniques and models in the study of the development and treatment of abdominal aortic aneurysm. Br J Surg. 1999;86:305–12.PubMedCrossRef
72.
go back to reference LeMaire SA, Carter SA, Won T, Wang X, Conklin LD, Coselli JS. The threat of adhesive embolization: BioGlue leaks through needle holes in aortic tissue and prosthetic grafts. Ann Thorac Surg. 2005;80:106–11.PubMedCrossRef LeMaire SA, Carter SA, Won T, Wang X, Conklin LD, Coselli JS. The threat of adhesive embolization: BioGlue leaks through needle holes in aortic tissue and prosthetic grafts. Ann Thorac Surg. 2005;80:106–11.PubMedCrossRef
73.
go back to reference Mahmood Z, Cook DS, Luckraz H, O’Keefe P. Fatal right ventricular function caused by BioGlue coronary embolization. J Thorac Cardiovasc Surg. 2004;128:770–1.PubMedCrossRef Mahmood Z, Cook DS, Luckraz H, O’Keefe P. Fatal right ventricular function caused by BioGlue coronary embolization. J Thorac Cardiovasc Surg. 2004;128:770–1.PubMedCrossRef
74.
go back to reference Rubio AJ, Sierra QJ, de Martinez AA, Delgado DC. Pulmonary embolism due to biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2001;12:650–1.CrossRef Rubio AJ, Sierra QJ, de Martinez AA, Delgado DC. Pulmonary embolism due to biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2001;12:650–1.CrossRef
75.
go back to reference Bernabeu E, Castella M, Barriuso C, Mulet J. Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2005;4:329–31.PubMedCrossRef Bernabeu E, Castella M, Barriuso C, Mulet J. Acute limb ischemia due to embolization of biological glue after repair of type A aortic dissection. Interact Cardiovasc Thorac Surg. 2005;4:329–31.PubMedCrossRef
76.
go back to reference Miller DC, Lansman SL, Cameron DE, Hanafusa Y, Kazui T, Bavaria JE, et al. Discussion: session 3—Dissection. Ann Thorac Surg. 2002;74:s1857–63.CrossRef Miller DC, Lansman SL, Cameron DE, Hanafusa Y, Kazui T, Bavaria JE, et al. Discussion: session 3—Dissection. Ann Thorac Surg. 2002;74:s1857–63.CrossRef
77.
go back to reference Guerrero MA, Cox M, Lumsden AB, Reardon M, Howell J. Embolus of surgical adhesive to the extremities causing acute ischemia: report to two cases. J Vasc Surg. 2003;40:571–3.CrossRef Guerrero MA, Cox M, Lumsden AB, Reardon M, Howell J. Embolus of surgical adhesive to the extremities causing acute ischemia: report to two cases. J Vasc Surg. 2003;40:571–3.CrossRef
78.
go back to reference Rampoldi V, Trimarchi S, Eagle KA, Nienaber CA, Oh JK, Bossone E, et al. Simple risk models to predict surgical mortality in acute type A aortic dissection; the International Registry of Acute Aortic Dissection score. Ann Thorac Surg. 2007;83:55–61.PubMedCrossRef Rampoldi V, Trimarchi S, Eagle KA, Nienaber CA, Oh JK, Bossone E, et al. Simple risk models to predict surgical mortality in acute type A aortic dissection; the International Registry of Acute Aortic Dissection score. Ann Thorac Surg. 2007;83:55–61.PubMedCrossRef
79.
go back to reference Gallo A, Davies RR, Coe MP, Elefteriades JA, Coady MA. Indications, timing, and prognosis of operative repair of aortic dissections. Semin Thorac Cardiovasc Surg. 2005;17:224–35.PubMedCrossRef Gallo A, Davies RR, Coe MP, Elefteriades JA, Coady MA. Indications, timing, and prognosis of operative repair of aortic dissections. Semin Thorac Cardiovasc Surg. 2005;17:224–35.PubMedCrossRef
80.
go back to reference Geirsson A, Bavaria JE, Swarr D, Keane MG, Woo YJ, Szeto WY, et al. Fate of the residual distal and proximal aorta after acute type A dissection repair using a contemporary surgical reconstruction algorithm. Ann Thorac Surg. 2007;84:1955–64.PubMedCrossRef Geirsson A, Bavaria JE, Swarr D, Keane MG, Woo YJ, Szeto WY, et al. Fate of the residual distal and proximal aorta after acute type A dissection repair using a contemporary surgical reconstruction algorithm. Ann Thorac Surg. 2007;84:1955–64.PubMedCrossRef
81.
go back to reference Estrera AL, Miller CC 3rd, Villa MA, Lee TY, Meada R, Irani A, et al. Proximal reoperations after repaired acute type A aortic dissection. Ann Thorac Surg. 2007;83:1603–9.PubMedCrossRef Estrera AL, Miller CC 3rd, Villa MA, Lee TY, Meada R, Irani A, et al. Proximal reoperations after repaired acute type A aortic dissection. Ann Thorac Surg. 2007;83:1603–9.PubMedCrossRef
82.
go back to reference Tanaka H, Okada K, Kawanishi Y, Matsumori M, Okita Y. Clinical significance of anastomotic leak in ascending aortic replacement for acute aortic dissection. Interact Cardiovasc Thorac Surg. 2009;9:209–13.PubMedCrossRef Tanaka H, Okada K, Kawanishi Y, Matsumori M, Okita Y. Clinical significance of anastomotic leak in ascending aortic replacement for acute aortic dissection. Interact Cardiovasc Thorac Surg. 2009;9:209–13.PubMedCrossRef
83.
go back to reference Goda M, Imoto K, Suzuki S, Uchida K, Yanagi H, Yasuda S, et al. Risk analysis for hospital mortality in patients with acute type A aortic dissection. Ann Thorac Surg. 2010;90:1246–50.PubMedCrossRef Goda M, Imoto K, Suzuki S, Uchida K, Yanagi H, Yasuda S, et al. Risk analysis for hospital mortality in patients with acute type A aortic dissection. Ann Thorac Surg. 2010;90:1246–50.PubMedCrossRef
84.
go back to reference Floten HS, Ravichandran PS, Furnary AP, Gately HL, Starr A. Adventitial inversion technique in repair of aortic dissection. Ann Thorac Surg. 1995;59:771–2.PubMedCrossRef Floten HS, Ravichandran PS, Furnary AP, Gately HL, Starr A. Adventitial inversion technique in repair of aortic dissection. Ann Thorac Surg. 1995;59:771–2.PubMedCrossRef
85.
go back to reference Tanaka K, Morioka K, Li W, Yamada N, Takamori A, Handa M, et al. Adventitial inversion technique without the aid of biologic glue or Teflon buttress for acute type A aortic dissection. Eur J Cardiothorac Surg. 2005;28:864–70.PubMedCrossRef Tanaka K, Morioka K, Li W, Yamada N, Takamori A, Handa M, et al. Adventitial inversion technique without the aid of biologic glue or Teflon buttress for acute type A aortic dissection. Eur J Cardiothorac Surg. 2005;28:864–70.PubMedCrossRef
Metadata
Title
The use of surgical glue in acute type A aortic dissection
Authors
Shinichi Suzuki
Munetaka Masuda
Kiyotaka Imoto
Publication date
01-04-2014
Publisher
Springer Japan
Published in
General Thoracic and Cardiovascular Surgery / Issue 4/2014
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-013-0343-0

Other articles of this Issue 4/2014

General Thoracic and Cardiovascular Surgery 4/2014 Go to the issue