Abstract

Background

Central venous catheterization may be difficult in morbidly obese patients because anatomic landmarks are often obscured.

Methods

We evaluated the efficacy and safety of ultrasound-guided central venous cannulation in 55 patients undergoing bariatric surgery. The usefulness of ultrasonic examination combined with intraatrial electrocardiogram as a diagnostic tool for catheter misplacement was studied.

Results

Preliminary ultrasound examination of the neck vessels demonstrated anatomical variations in the position of internal jugular vein in 19 cases and four unrecognized asymptomatic thromboses of the right internal jugular vein. Central venous catheterization was successful in all 55 patients, in 51 with single skin puncture, and in 42 with single vein puncture. In three cases in whom the catheter was misplaced, this was detected by bedside ultrasonic examination during the procedure and immediately corrected by real-time echographic visualization. No arterial puncture, no hematoma, and no pneumothorax occurred in any patient. Successful catheter placement was also confirmed in all patients by post-operative chest X-ray. No evidence of infection or thrombosis subsequently was noted.

Conclusions

The use of ultrasound guidance may increase the success rate and decrease the incidence of complications associated with central venous cannulation. The advantages of this approach is visualization of the anatomical structures at puncture site prior to skin puncture and the ability to track needle and guide-wire placement during the procedure. With its high accuracy in detecting catheter misplacement, bedside ultrasonic examination combined with intraatrial electrocardiogram may further decrease morbidity associated with misplaced central venous catheters.
Literature
1.
go back to reference National Institute for Clinical Excellence. NICE technology appraisal guidance No 49: guidance on the use of ultrasound locating devices for placing central venous catheters. London: NICE; 2002. National Institute for Clinical Excellence. NICE technology appraisal guidance No 49: guidance on the use of ultrasound locating devices for placing central venous catheters. London: NICE; 2002.
2.
go back to reference Karakitsos D, Labropoulos N, De Groot E, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Critical Care. 2006;10:R162.CrossRef Karakitsos D, Labropoulos N, De Groot E, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Critical Care. 2006;10:R162.CrossRef
3.
go back to reference Denys BG, Uretsky BF, Reddy PS. Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique. Circulation. 1993;87(5):1557–62.CrossRef Denys BG, Uretsky BF, Reddy PS. Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique. Circulation. 1993;87(5):1557–62.CrossRef
4.
go back to reference Urdaneta F, Gravenstein N. Central venous catheter insertion: it is finally time to start looking. Anesth Analg. 2007;105(3):879.CrossRef Urdaneta F, Gravenstein N. Central venous catheter insertion: it is finally time to start looking. Anesth Analg. 2007;105(3):879.CrossRef
5.
go back to reference Graham AS, Ozment C, Tegtmeyer K, et al. Central venous catheterization. N Engl J Med. 2007;356:e21.CrossRef Graham AS, Ozment C, Tegtmeyer K, et al. Central venous catheterization. N Engl J Med. 2007;356:e21.CrossRef
6.
go back to reference McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348:1123–33.CrossRef McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348:1123–33.CrossRef
7.
go back to reference Maury E, Guglielmotti J, Alzieu M, et al. Ultrasonic examination. An alternative to chest radiography after central venous catheter insertion? Am J Respir Crit Care Med. 2001;164:403–5.CrossRef Maury E, Guglielmotti J, Alzieu M, et al. Ultrasonic examination. An alternative to chest radiography after central venous catheter insertion? Am J Respir Crit Care Med. 2001;164:403–5.CrossRef
8.
go back to reference Gebhard RE, Szmuck P, Pivalizza EG, et al. The accuracy of electrocardiogram-controlled central line placement. Anesth Analg. 2007;104(1):65–70.CrossRef Gebhard RE, Szmuck P, Pivalizza EG, et al. The accuracy of electrocardiogram-controlled central line placement. Anesth Analg. 2007;104(1):65–70.CrossRef
9.
go back to reference Saager L, Wiesner E, Rothhammer A, Pestel G. Atrial electrocardiogram for verification of correct central venous catheter placement. Anesth Analg. 2007;105(5):1511.CrossRef Saager L, Wiesner E, Rothhammer A, Pestel G. Atrial electrocardiogram for verification of correct central venous catheter placement. Anesth Analg. 2007;105(5):1511.CrossRef
10.
go back to reference Bodenham AR. Can you justify not using ultrasound guidance for central venous access? Critical Care. 2006;10:175.CrossRef Bodenham AR. Can you justify not using ultrasound guidance for central venous access? Critical Care. 2006;10:175.CrossRef
11.
go back to reference Schummer W, Schummer C, Rose N, et al. Mechanical complications and malpositions of central venous cannulations by experienced operators. Intensive Care Med. 2007;33(6):1055–9.CrossRef Schummer W, Schummer C, Rose N, et al. Mechanical complications and malpositions of central venous cannulations by experienced operators. Intensive Care Med. 2007;33(6):1055–9.CrossRef
12.
go back to reference Milling T, Golden C, Melniker L, et al. Randomized controlled trial of single-operator vs. two-operator ultrasound guidance for internal jugular central venous cannulation. Acad Emerg Med. 2006;13:245–7.CrossRef Milling T, Golden C, Melniker L, et al. Randomized controlled trial of single-operator vs. two-operator ultrasound guidance for internal jugular central venous cannulation. Acad Emerg Med. 2006;13:245–7.CrossRef
13.
go back to reference Lichtenstein DA, Mezière G, Lascols N, et al. Ultrasound diagnosis of occult pneumothorax. Crit Care Med. 2005;33:1231–8.CrossRef Lichtenstein DA, Mezière G, Lascols N, et al. Ultrasound diagnosis of occult pneumothorax. Crit Care Med. 2005;33:1231–8.CrossRef
14.
go back to reference Jefferson P, Ball DR. Central venous access in morbidly obese patients. Anesth Analg. 2002;95(3):782.PubMed Jefferson P, Ball DR. Central venous access in morbidly obese patients. Anesth Analg. 2002;95(3):782.PubMed
15.
go back to reference Ottestad E, Schmiessing C, Brock-Utne JG, et al. Central venous access in obese patients: a potential complication. Anest Analg. 2006;102(4):1293–4.CrossRef Ottestad E, Schmiessing C, Brock-Utne JG, et al. Central venous access in obese patients: a potential complication. Anest Analg. 2006;102(4):1293–4.CrossRef
16.
go back to reference Haaverstad R, Latto PN, Vitale N. Right subclavian catheter perforation of the aorta due to an incorrect external landmark-guided insertion technique. CJEM. 2007;9(1):43–5.PubMed Haaverstad R, Latto PN, Vitale N. Right subclavian catheter perforation of the aorta due to an incorrect external landmark-guided insertion technique. CJEM. 2007;9(1):43–5.PubMed
17.
go back to reference Fujiki M, Guta CG, Lemmens HJM, et al. Is it more difficult to cannulate the right internal jugular vein in morbidly obese patients than in non obese patients? Obes Surg. 2008;18:1157–9.CrossRef Fujiki M, Guta CG, Lemmens HJM, et al. Is it more difficult to cannulate the right internal jugular vein in morbidly obese patients than in non obese patients? Obes Surg. 2008;18:1157–9.CrossRef
18.
go back to reference Turba U, Uflacker R, Hannegan C, et al. Anatomic relationship of the internal jugular vein and the common carotid artery applied to percutaneous transjugular procedures. Cardiovasc Intervent Radiol. 2005;28:303–6.CrossRef Turba U, Uflacker R, Hannegan C, et al. Anatomic relationship of the internal jugular vein and the common carotid artery applied to percutaneous transjugular procedures. Cardiovasc Intervent Radiol. 2005;28:303–6.CrossRef
19.
go back to reference Troianos C, Kuwik R, Pasqual J, et al. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anestesiology. 1996;85:43–8.CrossRef Troianos C, Kuwik R, Pasqual J, et al. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anestesiology. 1996;85:43–8.CrossRef
20.
go back to reference Maecken T, Grau T. Ultrasound imaging in vascular access. Crit Care Med. 2007;35(5):s178–85.CrossRef Maecken T, Grau T. Ultrasound imaging in vascular access. Crit Care Med. 2007;35(5):s178–85.CrossRef
21.
go back to reference Puel V, Caudry M, Le Metayer P, et al. Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through omplanted ports. Cancer. 1993;72:2248–52.CrossRef Puel V, Caudry M, Le Metayer P, et al. Superior vena cava thrombosis related to catheter malposition in cancer chemotherapy given through omplanted ports. Cancer. 1993;72:2248–52.CrossRef
22.
go back to reference Luciani A, Clement O, Halimi P, et al. Catheter-related upper extremity deep venous thrombosis in cancer patients: a prospective study based on Doppler US. Radiology. 2001;220:655–60.CrossRef Luciani A, Clement O, Halimi P, et al. Catheter-related upper extremity deep venous thrombosis in cancer patients: a prospective study based on Doppler US. Radiology. 2001;220:655–60.CrossRef
23.
go back to reference Chapman GA, Johnson D, Bodenham AR. Visualization of needle position using ultrasonography. Anesthesia. 2006;61:148–58.CrossRef Chapman GA, Johnson D, Bodenham AR. Visualization of needle position using ultrasonography. Anesthesia. 2006;61:148–58.CrossRef
24.
go back to reference Lichtenstein D, Meziere G, Lascols N, et al. Ultrasound diagnosis of occult pneumothorax. Crit Care Med. 2005;33(6):1231–8.CrossRef Lichtenstein D, Meziere G, Lascols N, et al. Ultrasound diagnosis of occult pneumothorax. Crit Care Med. 2005;33(6):1231–8.CrossRef
25.
go back to reference Farooq M. Can electrocardiogram-controlled central line placement decrease the need for routine chest radiographs after central venous cannulation? Anesth Analg. 2007;104(6):1614.CrossRef Farooq M. Can electrocardiogram-controlled central line placement decrease the need for routine chest radiographs after central venous cannulation? Anesth Analg. 2007;104(6):1614.CrossRef
26.
go back to reference Lanza C, Russo M, Fabrizzi G. Central venous cannulation: are routine chest radiographs necessary after B.mode and color Doppler sonography check? Pediatr Radiol. 2006;36:1252–6.CrossRef Lanza C, Russo M, Fabrizzi G. Central venous cannulation: are routine chest radiographs necessary after B.mode and color Doppler sonography check? Pediatr Radiol. 2006;36:1252–6.CrossRef
Metadata
Title
Ultrasound-Guided Central Venous Cannulation in Bariatric Patients
Authors
Claudia Brusasco
Francesco Corradi
Pier Luigi Zattoni
Claudio Launo
Yigal Leykin
Salvatore Palermo
Publication date
01-10-2009
Publisher
Springer New York
Published in
Obesity Surgery / Issue 10/2009
Print ISSN: 0960-8923
Electronic ISSN: 1708-0428
DOI
https://doi.org/10.1007/s11695-009-9902-y

Other articles of this Issue 10/2009

Obesity Surgery 10/2009 Go to the issue