Skip to main content
Top
Published in: Journal of Gastrointestinal Surgery 11/2017

01-11-2017 | Original Article

Utility of Endoanal Ultrasonography in Assessment of Primary and Recurrent Anal Fistulas and for Detection of Associated Anal Sphincter Defects

Authors: Sameh Hany Emile, Alaa Magdy, Mohamed Youssef, Waleed Thabet, Mahmoud Abdelnaby, Waleed Omar, Wael Khafagy

Published in: Journal of Gastrointestinal Surgery | Issue 11/2017

Login to get access

Abstract

Background

Tridimensional endoanal ultrasonography (3D-EAUS) has been used for the assessment of various anorectal lesions. Previous studies have reported good accuracy of 3D-EAUS in preoperative assessment of fistula-in-ano (FIA). This study aimed to assess the diagnostic utility of 3D-EAUS in preoperative evaluation of primary and recurrent FIA and its role in detection of associated anal sphincter (AS) defects.

Patients and Methods

Prospectively collected data of patients with FIA who were investigated with 3D-EAUS were reviewed. The findings of EAUS were compared with the intraoperative findings, the reference standard, to find the degree of agreement regarding the position of the internal opening (IO) and primary tract (PT), and presence of secondary tracts using kappa (k) coefficient test. A subgroup analysis was performed to compare the accuracy and sensitivity of EAUS for primary and recurrent FIA.

Results

Of the patients, 131 were included to the study. EAUS had an overall accuracy of 87, 88.5, and 89.5% in detection of IO, PT, and AS defects, respectively. There was very good concordance between the findings of EAUS and intraoperative findings for the investigated parameters (kappa = 0.748, 0.83, 0.935), respectively. Accuracy and sensitivity of EAUS in recurrent FIA were insignificantly lower than primary cases. EAUS detected occult AS defects in 5.3% of the patients studied.

Conclusion

The diagnostic utility of 3D-EAUS was comparable in primary and recurrent FIA. 3D-EAUS was able to detect symptomatic and occult AS defects with higher accuracy than clinical examination.
Literature
1.
go back to reference Rieger N, Tjandra J, Solomon M. Endoanal and endorectal ultrasound: applications in colorectal surgery. ANZ J Surg. 2004; 74(8):671–5.CrossRefPubMed Rieger N, Tjandra J, Solomon M. Endoanal and endorectal ultrasound: applications in colorectal surgery. ANZ J Surg. 2004; 74(8):671–5.CrossRefPubMed
4.
go back to reference Kim Y, Park YJ. Three-dimensional endoanal ultrasonographic assessment of an anal fistula with and without H(2)O(2) enhancement. World J Gastroenterol. 2009; 15(38):4810–5.CrossRefPubMedPubMedCentral Kim Y, Park YJ. Three-dimensional endoanal ultrasonographic assessment of an anal fistula with and without H(2)O(2) enhancement. World J Gastroenterol. 2009; 15(38):4810–5.CrossRefPubMedPubMedCentral
6.
go back to reference Cheong DM, Nogueras JJ, Wexner SD, Jagelman DG. Anal endosonography for recurrent anal fistulas: image enhancement with hydrogen peroxide. Dis Colon rectum. 1993;36(12):1158–60.CrossRefPubMed Cheong DM, Nogueras JJ, Wexner SD, Jagelman DG. Anal endosonography for recurrent anal fistulas: image enhancement with hydrogen peroxide. Dis Colon rectum. 1993;36(12):1158–60.CrossRefPubMed
8.
go back to reference Buchanan GN, Halligan S, Bartram CI, Williams AB, Tarroni D, Cohen CR. Clinical examination, endosonography, and MR imaging in preoperative assessment of fistula in ano: comparison with outcome-based reference standard. Radiology. 2004;233(3):674–81.CrossRefPubMed Buchanan GN, Halligan S, Bartram CI, Williams AB, Tarroni D, Cohen CR. Clinical examination, endosonography, and MR imaging in preoperative assessment of fistula in ano: comparison with outcome-based reference standard. Radiology. 2004;233(3):674–81.CrossRefPubMed
9.
go back to reference Wasserberg N et al. Three-dimensional endoanal ultrasonography of external anal sphincter defects in patients with fecal incontinence: correlation with symptoms and manometry. Colorectal Dis. 2011; 13(4):449–53.CrossRefPubMed Wasserberg N et al. Three-dimensional endoanal ultrasonography of external anal sphincter defects in patients with fecal incontinence: correlation with symptoms and manometry. Colorectal Dis. 2011; 13(4):449–53.CrossRefPubMed
11.
go back to reference Johnson JK, Lindow SW, Duthie GS. The prevalence of occult obstetric anal sphincter injury following childbirth: literature review. J Matern Fetal Neonatal Med. 2007; 20 (7):547–54.CrossRefPubMed Johnson JK, Lindow SW, Duthie GS. The prevalence of occult obstetric anal sphincter injury following childbirth: literature review. J Matern Fetal Neonatal Med. 2007; 20 (7):547–54.CrossRefPubMed
12.
go back to reference Jorge JM, Wexner SD. Etiology and management of fecal incontinence. Dis Colon rectum. 1993; 36:77–97.CrossRefPubMed Jorge JM, Wexner SD. Etiology and management of fecal incontinence. Dis Colon rectum. 1993; 36:77–97.CrossRefPubMed
13.
go back to reference Cho DY. Endosonographic criteria for an internal opening of fistula-in-ano. Dis Colon rectum. 1999; 42(4):515–8.CrossRefPubMed Cho DY. Endosonographic criteria for an internal opening of fistula-in-ano. Dis Colon rectum. 1999; 42(4):515–8.CrossRefPubMed
15.
go back to reference Deen KI, Williams JG, Hutchinson R, Keighley MR, Kumar D. Fistulas in ano: endoanal ultrasonographic assessment assists decision making for surgery. Gut. 1994;35(3):391–4.CrossRefPubMedPubMedCentral Deen KI, Williams JG, Hutchinson R, Keighley MR, Kumar D. Fistulas in ano: endoanal ultrasonographic assessment assists decision making for surgery. Gut. 1994;35(3):391–4.CrossRefPubMedPubMedCentral
16.
go back to reference Poen AC, Felt-Bersma RJ, Eijsbouts QA, Cuesta MA, Meuwissen SG. Hydrogen peroxide-enhanced transanal ultrasound in the assessment of fistula-in-ano. Dis Colon rectum. 1998;41(9):1147–52.CrossRefPubMed Poen AC, Felt-Bersma RJ, Eijsbouts QA, Cuesta MA, Meuwissen SG. Hydrogen peroxide-enhanced transanal ultrasound in the assessment of fistula-in-ano. Dis Colon rectum. 1998;41(9):1147–52.CrossRefPubMed
17.
go back to reference Xue Y, Ding S, Ding Y, Liu F. Comparison of two-dimensional ultrasound and three-dimensional endoanal ultrasound in the diagnosis of perianal fistula. Zhonghua Wei Chang Wai Ke Za Zhi. 2014;17(12):1187–9.PubMed Xue Y, Ding S, Ding Y, Liu F. Comparison of two-dimensional ultrasound and three-dimensional endoanal ultrasound in the diagnosis of perianal fistula. Zhonghua Wei Chang Wai Ke Za Zhi. 2014;17(12):1187–9.PubMed
20.
go back to reference Emile SH, Elfeki H, Thabet W, et al. Predictive factors for recurrence of high transsphincteric anal fistula after placement of seton. J Surg Res. 2017; 213: 261–268.CrossRefPubMed Emile SH, Elfeki H, Thabet W, et al. Predictive factors for recurrence of high transsphincteric anal fistula after placement of seton. J Surg Res. 2017; 213: 261–268.CrossRefPubMed
21.
go back to reference Kołodziejczak M, Santoro GA, Obcowska A, Lorenc Z, Mańczak M, Sudoł-Szopińska I. Three-dimensional endoanal ultrasound is accurate and reproducible in determining type and height of anal fistulae. Colorectal Dis. 2016. https://doi.org/10.1111/codi.13580. Kołodziejczak M, Santoro GA, Obcowska A, Lorenc Z, Mańczak M, Sudoł-Szopińska I. Three-dimensional endoanal ultrasound is accurate and reproducible in determining type and height of anal fistulae. Colorectal Dis. 2016. https://​doi.​org/​10.​1111/​codi.​13580.
22.
go back to reference Sirikurnpiboon S, Phadhana-anake O, Awapittaya B. Comparison of endoanal ultrasound with clinical diagnosis in anal fistula assessment. J Med Assoc Thai. 2016;99 Suppl 2:S69–74.PubMed Sirikurnpiboon S, Phadhana-anake O, Awapittaya B. Comparison of endoanal ultrasound with clinical diagnosis in anal fistula assessment. J Med Assoc Thai. 2016;99 Suppl 2:S69–74.PubMed
24.
go back to reference Buchanan GN, Bartram CI, Williams AB, Halligan S, Cohen CR. Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano. Dis Colon rectum 2005;48:141–147.CrossRefPubMed Buchanan GN, Bartram CI, Williams AB, Halligan S, Cohen CR. Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano. Dis Colon rectum 2005;48:141–147.CrossRefPubMed
26.
go back to reference Gravante G, Giordano P. The role of three-dimensional endoluminal ultrasound imaging in the evaluation of anorectal diseases: a review. Surg Endosc. 2008;22(7):1570.CrossRefPubMed Gravante G, Giordano P. The role of three-dimensional endoluminal ultrasound imaging in the evaluation of anorectal diseases: a review. Surg Endosc. 2008;22(7):1570.CrossRefPubMed
27.
go back to reference Yee LF, Birnbaum EH, Read TE, Kodner IJ, Fleshman JW. Use of endoanal ultrasound in patients with rectovaginal fistulas. Dis Colon rectum. 1999;42(8):1057–64.CrossRefPubMed Yee LF, Birnbaum EH, Read TE, Kodner IJ, Fleshman JW. Use of endoanal ultrasound in patients with rectovaginal fistulas. Dis Colon rectum. 1999;42(8):1057–64.CrossRefPubMed
29.
go back to reference West RL, Zimmerman DD, Dwarkasing S, Hussain SM, Hop WC, Schouten WR, et al. Prospective comparison of hydrogen peroxide-enhanced three-dimensional endoanal ultrasonographyand endoanal magnetic resonance imaging of perianal fistulas. Dis Colon rectum. 2003;46(10):1407–15.CrossRefPubMed West RL, Zimmerman DD, Dwarkasing S, Hussain SM, Hop WC, Schouten WR, et al. Prospective comparison of hydrogen peroxide-enhanced three-dimensional endoanal ultrasonographyand endoanal magnetic resonance imaging of perianal fistulas. Dis Colon rectum. 2003;46(10):1407–15.CrossRefPubMed
Metadata
Title
Utility of Endoanal Ultrasonography in Assessment of Primary and Recurrent Anal Fistulas and for Detection of Associated Anal Sphincter Defects
Authors
Sameh Hany Emile
Alaa Magdy
Mohamed Youssef
Waleed Thabet
Mahmoud Abdelnaby
Waleed Omar
Wael Khafagy
Publication date
01-11-2017
Publisher
Springer US
Published in
Journal of Gastrointestinal Surgery / Issue 11/2017
Print ISSN: 1091-255X
Electronic ISSN: 1873-4626
DOI
https://doi.org/10.1007/s11605-017-3574-z

Other articles of this Issue 11/2017

Journal of Gastrointestinal Surgery 11/2017 Go to the issue