Skip to main content
Top
Published in: Journal of Medical Systems 2/2014

01-02-2014 | Research Article

Variability of Subspecialty-Specific Anesthesia-Controlled Times at Two Academic Institutions

Authors: Bhavani Shankar Kodali, K. Dennie Kim, Hugh Flanagan, Jesse M. Ehrenfeld, Richard D. Urman

Published in: Journal of Medical Systems | Issue 2/2014

Login to get access

Abstract

Realistic scheduling of operating room cases decreases costs, optimizes utilization and improves staff and patient satisfaction. Currently limited data exists to establish anesthesia-controlled time benchmarks based on specific subspecialty service. In this multicenter retrospective analysis of cases performed during a 53 month period at two large multispecialty academic institutions, data were retrieved from the perioperative information systems at each center. Both induction and emergence times were calculated. We then determined mean and median anesthesia controlled times based on each subspecialty service and compared them to previously published anesthesia-controlled time data. We obtained data on 104,184 cases at hospital A, and 122,560 cases at Hospital B. For all specialties at hospital A and hospital B, median induction time was 16.0 min and 17.0 min, emergence time was 14.0 and 8.0 min, and total anesthesia controlled time was 31.0 min and 27.0 min respectively. There was considerable variability among different surgical specialties deviating from the previously established 30 min benchmark. Subspecialties with lower total anesthesia controlled times in both centers were pain, general surgery, gynecology, plastic surgery and urology. Subspecialties with higher total anesthesia controlled times in both centers included cardiac surgery, neurosurgery, transplant and vascular. Cardiac surgery had the highest total time of 60 min and 50 min at Hospital A and B respectively. Individual specialty-specific anesthesia controlled times should be used for case scheduling and to benchmark anesthesia performance.
Literature
1.
go back to reference Dexter, F. E. R., Bayman, E. O., and Ledolter, J., Estimating surgical case durations and making comparisons among facilities: Identifying facilities with lower anesthesia professional fees. Anesth. Analg. 116(5):1103–1115, 2013.CrossRef Dexter, F. E. R., Bayman, E. O., and Ledolter, J., Estimating surgical case durations and making comparisons among facilities: Identifying facilities with lower anesthesia professional fees. Anesth. Analg. 116(5):1103–1115, 2013.CrossRef
2.
go back to reference Dexter, F., Ledolter, J., Tiwari, V., and Epstein, R. H., Value of a scheduled duration quantified in terms of equivalent numbers of historical cases. Anesth. Analg. 117(1):205–210, 2013.CrossRef Dexter, F., Ledolter, J., Tiwari, V., and Epstein, R. H., Value of a scheduled duration quantified in terms of equivalent numbers of historical cases. Anesth. Analg. 117(1):205–210, 2013.CrossRef
3.
go back to reference Harders, M., Malangoni, M. A., Weight, S., and Sidhu, T., Improving operating room efficiency through process redesign. Surgery 140(4):509–514, 2006. discussion 14–6.CrossRef Harders, M., Malangoni, M. A., Weight, S., and Sidhu, T., Improving operating room efficiency through process redesign. Surgery 140(4):509–514, 2006. discussion 14–6.CrossRef
4.
go back to reference Eijkemans, M. J., van Houdenhoven, M., Nguyen, T., Boersma, E., Steyerberg, E. W., and Kazemier, G., Predicting the unpredictable: a new prediction model for operating room times using individual characteristics and the surgeon’s estimate. Anesthesiology 112(1):41–49, 2010.CrossRef Eijkemans, M. J., van Houdenhoven, M., Nguyen, T., Boersma, E., Steyerberg, E. W., and Kazemier, G., Predicting the unpredictable: a new prediction model for operating room times using individual characteristics and the surgeon’s estimate. Anesthesiology 112(1):41–49, 2010.CrossRef
5.
go back to reference Strum, D. P. V. L., and May, J. H., Surgical subspecialty block utilization and capacity planning: A minimal cost analysis model. Anesthesiology 90(4):1176–1185, 1999.CrossRef Strum, D. P. V. L., and May, J. H., Surgical subspecialty block utilization and capacity planning: A minimal cost analysis model. Anesthesiology 90(4):1176–1185, 1999.CrossRef
6.
go back to reference Overdyk, F. J., Harvey, S. C., Fishman, R. L., and Shippey, F., Successful strategies for improving operating room efficiency at academic institutions. Anesth. Analg. 86(4):896–906, 1998. Overdyk, F. J., Harvey, S. C., Fishman, R. L., and Shippey, F., Successful strategies for improving operating room efficiency at academic institutions. Anesth. Analg. 86(4):896–906, 1998.
7.
go back to reference Ehrenwerth, J., Escobar, A., Davis, E. A., Watrous, G. A., Fisch, G. S., Kain, Z. N., et al., Can the attending anesthesiologist accurately predict the duration of anesthesia induction? Anesth. Analg. 103(4):938–940, 2006.CrossRef Ehrenwerth, J., Escobar, A., Davis, E. A., Watrous, G. A., Fisch, G. S., Kain, Z. N., et al., Can the attending anesthesiologist accurately predict the duration of anesthesia induction? Anesth. Analg. 103(4):938–940, 2006.CrossRef
8.
go back to reference Zafar, S. U., Khan, F. A., and Khan, M., Standardization of anaesthesia ready time and reasons of delay in induction of anaesthesia. J. Pak. Med. Assoc. 56(3):112–115, 2006. Zafar, S. U., Khan, F. A., and Khan, M., Standardization of anaesthesia ready time and reasons of delay in induction of anaesthesia. J. Pak. Med. Assoc. 56(3):112–115, 2006.
9.
go back to reference Kougias, P., Tiwari, V., Barshes, N. R., Bechara, C. F., Lowery, B., Pisimisis, G., et al., Modeling anesthetic times. Predictors and implications for short-term outcomes. J. Surg. Res. 180(1):1–7, 2013.CrossRef Kougias, P., Tiwari, V., Barshes, N. R., Bechara, C. F., Lowery, B., Pisimisis, G., et al., Modeling anesthetic times. Predictors and implications for short-term outcomes. J. Surg. Res. 180(1):1–7, 2013.CrossRef
10.
go back to reference Dexter, F., Coffin, S., and Tinker, J. H., Decreases in anesthesia-controlled time cannot permit one additional surgical operation to be reliably scheduled during the workday. Anesth. Analg. 81(6):1263–1268, 1995. Dexter, F., Coffin, S., and Tinker, J. H., Decreases in anesthesia-controlled time cannot permit one additional surgical operation to be reliably scheduled during the workday. Anesth. Analg. 81(6):1263–1268, 1995.
11.
go back to reference Glossary of times used for scheduling and monitoring of diagnostic and therapeutic procedures. AORN J. 66(4):601–606, 1997. Glossary of times used for scheduling and monitoring of diagnostic and therapeutic procedures. AORN J. 66(4):601–606, 1997.
12.
go back to reference Mazzei, W. J., Operating room start times and turnover times in a university hospital. J. Clin. Anesth. 6(5):405–408, 1994.CrossRef Mazzei, W. J., Operating room start times and turnover times in a university hospital. J. Clin. Anesth. 6(5):405–408, 1994.CrossRef
13.
go back to reference Donham, R. T., Defining measurable OR-PR scheduling, efficiency, and utilization data elements: The Association of Anesthesia Clinical Directors procedural times glossary. Int. Anesthesiol. Clin. 36(1):15–29, 1998.CrossRef Donham, R. T., Defining measurable OR-PR scheduling, efficiency, and utilization data elements: The Association of Anesthesia Clinical Directors procedural times glossary. Int. Anesthesiol. Clin. 36(1):15–29, 1998.CrossRef
14.
go back to reference Dufek, S., Gaucher, E., Gialanella, J., Kratochwill, E., Learned, D., Sonda, P., et al., The total quality process applied to the operating rooms and other clinical processes. Surgery 113(3):255–259, 1993. Dufek, S., Gaucher, E., Gialanella, J., Kratochwill, E., Learned, D., Sonda, P., et al., The total quality process applied to the operating rooms and other clinical processes. Surgery 113(3):255–259, 1993.
15.
go back to reference Kanich, D. G., and Byrd, J. R., How to increase efficiency in the operating room. Surg Clin N Am 76(1):161–173, 1996.CrossRef Kanich, D. G., and Byrd, J. R., How to increase efficiency in the operating room. Surg Clin N Am 76(1):161–173, 1996.CrossRef
16.
go back to reference Wright, I. H., Kooperberg, C., Bonar, B. A., and Bashein, G., Statistical modeling to predict elective surgery time. Comparison with a computer scheduling system and surgeon-provided estimates. Anesthesiology 85(6):1235–1245, 1996.CrossRef Wright, I. H., Kooperberg, C., Bonar, B. A., and Bashein, G., Statistical modeling to predict elective surgery time. Comparison with a computer scheduling system and surgeon-provided estimates. Anesthesiology 85(6):1235–1245, 1996.CrossRef
17.
go back to reference Kwok, A. C., Funk, L. M., Baltaga, R., Lipsitz, S. R., Merry, A. F., Dziekan, G., et al., Implementation of the World Health Organization surgical safety checklist, including introduction of pulse oximetry, in a resource-limited setting. Ann. Surg. 257(4):633–639, 2013.CrossRef Kwok, A. C., Funk, L. M., Baltaga, R., Lipsitz, S. R., Merry, A. F., Dziekan, G., et al., Implementation of the World Health Organization surgical safety checklist, including introduction of pulse oximetry, in a resource-limited setting. Ann. Surg. 257(4):633–639, 2013.CrossRef
18.
go back to reference Haynes, A. B., Weiser, T. G., Berry, W. R., Lipsitz, S. R., Breizat, A. H., Dellinger, E. P., et al., A surgical safety checklist to reduce morbidity and mortality in a global population. N. Engl. J. Med. 360(5):491–499, 2009.CrossRef Haynes, A. B., Weiser, T. G., Berry, W. R., Lipsitz, S. R., Breizat, A. H., Dellinger, E. P., et al., A surgical safety checklist to reduce morbidity and mortality in a global population. N. Engl. J. Med. 360(5):491–499, 2009.CrossRef
19.
go back to reference Urman, R. D., Sarin, P., Mitani, A., Philip, B., and Eappen, S., Presence of anesthesia resident trainees in day surgery unit has mixed effects on operating room efficiency measures. Ochsner J 12(1):25–29, 2012. Urman, R. D., Sarin, P., Mitani, A., Philip, B., and Eappen, S., Presence of anesthesia resident trainees in day surgery unit has mixed effects on operating room efficiency measures. Ochsner J 12(1):25–29, 2012.
20.
go back to reference Davis, E. A., Escobar, A., Ehrenwerth, J., Watrous, G. A., Fisch, G. S., Kain, Z. N., et al., Resident teaching versus the operating room schedule: An independent observer-based study of 1558 cases. Anesth. Analg. 103(4):932–937, 2006.CrossRef Davis, E. A., Escobar, A., Ehrenwerth, J., Watrous, G. A., Fisch, G. S., Kain, Z. N., et al., Resident teaching versus the operating room schedule: An independent observer-based study of 1558 cases. Anesth. Analg. 103(4):932–937, 2006.CrossRef
21.
go back to reference Eappen, S., Flanagan, H., and Bhattacharyya, N., Introduction of anesthesia resident trainees to the operating room does not lead to changes in anesthesia-controlled times for efficiency measures. Anesthesiology 101(5):1210–1214, 2004.CrossRef Eappen, S., Flanagan, H., and Bhattacharyya, N., Introduction of anesthesia resident trainees to the operating room does not lead to changes in anesthesia-controlled times for efficiency measures. Anesthesiology 101(5):1210–1214, 2004.CrossRef
22.
go back to reference Broussard, D. M., and Couch, M. C., Anesthesia preparation time is not affected by the experience level of the resident involved during his/her first month of adult cardiac surgery. J. Cardiothorac. Vasc. Anesth. 25(5):766–769, 2011.CrossRef Broussard, D. M., and Couch, M. C., Anesthesia preparation time is not affected by the experience level of the resident involved during his/her first month of adult cardiac surgery. J. Cardiothorac. Vasc. Anesth. 25(5):766–769, 2011.CrossRef
23.
go back to reference Unpublished Data. Department of Anesthesiology, Perioperative and Pain Medicine. Brigham and Women’s Hospital: Boston MA. Unpublished Data. Department of Anesthesiology, Perioperative and Pain Medicine. Brigham and Women’s Hospital: Boston MA.
24.
go back to reference Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., et al., Prevention of central venous catheter-related infections by using maximal sterile barrier precautions during insertion. Infect. Control Hosp. Epidemiol. 15(4 Pt 1):231–238, 1994.CrossRef Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., et al., Prevention of central venous catheter-related infections by using maximal sterile barrier precautions during insertion. Infect. Control Hosp. Epidemiol. 15(4 Pt 1):231–238, 1994.CrossRef
25.
go back to reference Overby, D. W., Kohn, G. P., Colton, K. J., Stavas, J. M., Dixon, R. G., Passannante, A., et al., Central venous line placement prior to gastric bypass improves operating room efficiency. ISRN Surg. 2012:816871, 2012.CrossRef Overby, D. W., Kohn, G. P., Colton, K. J., Stavas, J. M., Dixon, R. G., Passannante, A., et al., Central venous line placement prior to gastric bypass improves operating room efficiency. ISRN Surg. 2012:816871, 2012.CrossRef
26.
go back to reference Mariano, E. R., Chu, L. F., Peinado, C. R., and Mazzei, W. J., Anesthesia-controlled time and turnover time for ambulatory upper extremity surgery performed with regional versus general anesthesia. J. Clin. Anesth. 21(4):253–257, 2009.CrossRef Mariano, E. R., Chu, L. F., Peinado, C. R., and Mazzei, W. J., Anesthesia-controlled time and turnover time for ambulatory upper extremity surgery performed with regional versus general anesthesia. J. Clin. Anesth. 21(4):253–257, 2009.CrossRef
Metadata
Title
Variability of Subspecialty-Specific Anesthesia-Controlled Times at Two Academic Institutions
Authors
Bhavani Shankar Kodali
K. Dennie Kim
Hugh Flanagan
Jesse M. Ehrenfeld
Richard D. Urman
Publication date
01-02-2014
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 2/2014
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-014-0011-7

Other articles of this Issue 2/2014

Journal of Medical Systems 2/2014 Go to the issue