Non-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare

Authors: Youngzoon Yoon, Jung H. Cho, Gilwon Yoon

Published in: Journal of Medical Systems | Issue 4/2009

Login to get access

Abstract

Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure (BP) was estimated from pulse transit time (PTT) and PPG waveform. PTT is a time interval between an R-wave of electrocardiography (ECG) and a photoplethysmography (PPG) signal. This method does not require an aircuff and only a minimal inconvenience of attaching electrodes and LED/photo detector sensors on a subject. PTT computed between the ECG R-wave and the maximum first derivative PPG was strongly correlated with systolic blood pressure (SBP) (R = −0.712) compared with other PTT values, and the diastolic time proved to be appropriate for estimation diastolic blood pressure (DBP) (R = −0.764). The percent errors of SBP using the individual regression line (4–11%) were lower than those using the regression line obtained from all five subjects (9–14%). On the other hand, the DBP estimation did not show much difference between the individual regression (4–10%) and total regression line (6–10%). Our developed device had a total size of 7 × 13.5 cm and was operated by single 3-V battery. Biosignals can be measured for 72 h continuously without external interruptions. Through a serial network communication, an external personal computer can monitor measured waveforms in real time. Our proposed method can be used for non-constrained, thus continuous BP monitoring for the purpose of personal healthcare.
Literature
1.
go back to reference Chen, Y., Li, L., Hershler, C., and Dill, R. P., Continuous non-invasive blood pressure monitoring method and apparatus. US patent. 6,893,401 B2, 2005. Chen, Y., Li, L., Hershler, C., and Dill, R. P., Continuous non-invasive blood pressure monitoring method and apparatus. US patent. 6,893,401 B2, 2005.
2.
go back to reference Nichols, W., and O’Rourke, M., Mcdonald’s blood flow in arteries. Arnold, London, 1998. Nichols, W., and O’Rourke, M., Mcdonalds blood flow in arteries. Arnold, London, 1998.
3.
go back to reference Webster, J. G., Medical instrumentation: Application of design. Wiley, New York, 1998. Webster, J. G., Medical instrumentation: Application of design. Wiley, New York, 1998.
4.
go back to reference Hosaka, H., Sakata, H., Sugo, Y., Sohma, T., and Kasuya, H., Pulse-wave propagation time basis blood pressure monitor. US patent, 5, 649,543, 1998. Hosaka, H., Sakata, H., Sugo, Y., Sohma, T., and Kasuya, H., Pulse-wave propagation time basis blood pressure monitor. US patent, 5, 649,543, 1998.
5.
go back to reference Teng, X. F., and Zhang, Y. T., Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach. Pro. 25 Ann. IEEE EMBS, 3153–3156, 2003. Teng, X. F., and Zhang, Y. T., Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach. Pro. 25 Ann. IEEE EMBS, 3153–3156, 2003.
6.
go back to reference Yoon, G., Lee, J. Y., Jeon, K. J., Park, K. K., and Kim, H. S., Development of a compact home health monitor for telemedicine. Telemedicine and e-Health. 11(6):660–667, 2005.CrossRef Yoon, G., Lee, J. Y., Jeon, K. J., Park, K. K., and Kim, H. S., Development of a compact home health monitor for telemedicine. Telemedicine and e-Health. 11(6):660–667, 2005.CrossRef
7.
go back to reference Barschdorff, D., and Erig, M., Continuous blood pressure monitoring during stress ECG. Biomed. Tech. (Berl.) 43, 34–39, 1998. Barschdorff, D., and Erig, M., Continuous blood pressure monitoring during stress ECG. Biomed. Tech. (Berl.) 43, 34–39, 1998.
8.
go back to reference Naschitz, J. E., Bezobchuk, S., Priselac, R., Sundick, S., Dreyfuss, D., Khorshidi, I. et al, Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience. J. Clin. Monit. Comput. 18:333–342, 2004. doi:10.1007/s10877-005-4300-z.CrossRef Naschitz, J. E., Bezobchuk, S., Priselac, R., Sundick, S., Dreyfuss, D., Khorshidi, I. et al, Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience. J. Clin. Monit. Comput. 18:333–342, 2004. doi:10.​1007/​s10877-005-4300-z.CrossRef
9.
go back to reference Curb, J. D., Labarthe, D. R., Cooper, S. P., Cutter, G. R., and Hawkins, C. M., Training and certification of blood pressure observers. Hypertension. 5:610–614, 1983. Curb, J. D., Labarthe, D. R., Cooper, S. P., Cutter, G. R., and Hawkins, C. M., Training and certification of blood pressure observers. Hypertension. 5:610–614, 1983.
11.
go back to reference Yano, K., Kimora, T., Sato, Y., Nichiwaki, K., and Shimada, Y., Delay time between the R-wave and maximum pulse wave upstroke reflects alterations in blood pressure. Anesthesiol. 96:A491, 2002. Yano, K., Kimora, T., Sato, Y., Nichiwaki, K., and Shimada, Y., Delay time between the R-wave and maximum pulse wave upstroke reflects alterations in blood pressure. Anesthesiol. 96:A491, 2002.
13.
go back to reference Chen, W., Tobahashi, T., Ichikawa, S., Takeuchi, Y., and Togawa, T., Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med. Biol. Eng. Comput. 38:569–574, 2000. doi:10.1007/BF02345755.CrossRef Chen, W., Tobahashi, T., Ichikawa, S., Takeuchi, Y., and Togawa, T., Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration. Med. Biol. Eng. Comput. 38:569–574, 2000. doi:10.​1007/​BF02345755.CrossRef
18.
go back to reference Martens, H. A., and Dardenne, P., Validation and verification of regression in small data sets. Chemometr. Intell. Lab. Syst. 44:99–122, 1998.CrossRef Martens, H. A., and Dardenne, P., Validation and verification of regression in small data sets. Chemometr. Intell. Lab. Syst. 44:99–122, 1998.CrossRef
19.
go back to reference Stone, M., An asymptotic equivalence of choice of model by cross-validation and Akaike’s criterion. J. R. Stat. Soc. B. 38:44–47, 1977. Stone, M., An asymptotic equivalence of choice of model by cross-validation and Akaike’s criterion. J. R. Stat. Soc. B. 38:44–47, 1977.
20.
go back to reference Bland, J. M., and Altman, D. G., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1:307–310, 1986. Bland, J. M., and Altman, D. G., Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1:307–310, 1986.
21.
go back to reference Chawla, R., Kumarvel, V., Girdhar, K. K., and Sethi, A. K., Can pulse oximetery be used to measure systolic blood pressure. Anesth. Analg. 74:196–200, 1992. Chawla, R., Kumarvel, V., Girdhar, K. K., and Sethi, A. K., Can pulse oximetery be used to measure systolic blood pressure. Anesth. Analg. 74:196–200, 1992.
22.
24.
go back to reference Smith, R. P., Argod, J., Peping, J. L., and Levy, P. A., Pulse transit time: an appraisal of potential clinical applications. Thorax. 54:452–458, 1999.CrossRef Smith, R. P., Argod, J., Peping, J. L., and Levy, P. A., Pulse transit time: an appraisal of potential clinical applications. Thorax. 54:452–458, 1999.CrossRef
25.
go back to reference Wippermann, C. F., Schranz, D., and Huth, R. G., Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children. J. Clin. Monit. 11, 324–328, 1995. doi:10.1007/BF01616991. Wippermann, C. F., Schranz, D., and Huth, R. G., Evaluation of the pulse wave arrival time as a marker for blood pressure changes in critically ill infants and children. J. Clin. Monit. 11, 324–328, 1995. doi:10.​1007/​BF01616991.
26.
go back to reference Trzeciak, B. G., Siebert, J., Scislo, J., Jaskiewicz, M., and Babinska, Z., Telemedicine: the determination of fatal cardiovascular risk in internet users population. Comput. Cardiol. 32:367–370, 2005. doi:10.1109/CIC.2005.1588113.CrossRef Trzeciak, B. G., Siebert, J., Scislo, J., Jaskiewicz, M., and Babinska, Z., Telemedicine: the determination of fatal cardiovascular risk in internet users population. Comput. Cardiol. 32:367–370, 2005. doi:10.​1109/​CIC.​2005.​1588113.CrossRef
Metadata
Title
Non-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare
Authors
Youngzoon Yoon
Jung H. Cho
Gilwon Yoon
Publication date
01-08-2009
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 4/2009
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-008-9186-0

Other articles of this Issue 4/2009

Journal of Medical Systems 4/2009 Go to the issue