Abstract

This review presents an overview of previously reported non-invasive intra-abdominal pressure (IAP) measurement techniques. Each section covers the basic physical principles and methodology of the various measurement techniques, the experimental results, and the advantages and disadvantages of each method. The most promising non-invasive methods for IAP measurement are microwave reflectometry and ultrasound assessment, in combination with an applied external force.
Literature
1.
go back to reference Malbrain ML, Chiumello D, Cesana BM, Reintam Blaser A, Starkopf J, Sugrue M, Pelosi P, Severgnini P, Hernandez G, Brienza N, Kirkpatrick AW, Schachtrupp A, Kempchen J, Estenssoro E, Vidal MG, De Laet I, De Keulenaer BL. WAKE-Up! Investigators. A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!). Minerva Anestesiol. 2014;80(3):293–306.PubMed Malbrain ML, Chiumello D, Cesana BM, Reintam Blaser A, Starkopf J, Sugrue M, Pelosi P, Severgnini P, Hernandez G, Brienza N, Kirkpatrick AW, Schachtrupp A, Kempchen J, Estenssoro E, Vidal MG, De Laet I, De Keulenaer BL. WAKE-Up! Investigators. A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!). Minerva Anestesiol. 2014;80(3):293–306.PubMed
2.
go back to reference Kirkpatrick AW, Sugrue M, McKee JL, Pereira BM, Roberts DJ, Waele JJ, Leppaniemi A, EjikeJC BAR, D’Amours S, Keulenaer BD, Malbrain ML. Update from the Abdominal Compartment Society (WSACS) on intra-abdominal hypertension and abdominal compartment syndrome: past, present, and future beyond Banff 2017. Anaesthesiol Intensive Ther. 2017;49(2):83–7. https://doi.org/10.5603/AIT.a2017.0019.CrossRefPubMed Kirkpatrick AW, Sugrue M, McKee JL, Pereira BM, Roberts DJ, Waele JJ, Leppaniemi A, EjikeJC BAR, D’Amours S, Keulenaer BD, Malbrain ML. Update from the Abdominal Compartment Society (WSACS) on intra-abdominal hypertension and abdominal compartment syndrome: past, present, and future beyond Banff 2017. Anaesthesiol Intensive Ther. 2017;49(2):83–7. https://​doi.​org/​10.​5603/​AIT.​a2017.​0019.CrossRefPubMed
3.
go back to reference Malbrain ML, Cheatham ML, Kirkpatrick AW, Sugrue M, Parr M, De Waele JJ, Balogh Z, Leppäniemi A, Olvera C, Ivatury R, D’Amours S, Wendon J, Hillman K, Johansson K, Kolkman K, Wilmer A. Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome I definitions. Intensive Care Med. 2006. https://doi.org/10.1007/s00134-006-0349-5.CrossRefPubMed Malbrain ML, Cheatham ML, Kirkpatrick AW, Sugrue M, Parr M, De Waele JJ, Balogh Z, Leppäniemi A, Olvera C, Ivatury R, D’Amours S, Wendon J, Hillman K, Johansson K, Kolkman K, Wilmer A. Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome I definitions. Intensive Care Med. 2006. https://​doi.​org/​10.​1007/​s00134-006-0349-5.CrossRefPubMed
6.
go back to reference Balogh Z, De Waele JJ, Malbrain ML. Continuous intra-abdominal pressure monitoring. Acta Clin Belg. 2007;1:26–322.CrossRef Balogh Z, De Waele JJ, Malbrain ML. Continuous intra-abdominal pressure monitoring. Acta Clin Belg. 2007;1:26–322.CrossRef
8.
13.
go back to reference Cohn MA, Rao AS, Broudy M, Birch S, Watson H, Atkins N, Davis B, Stott FD, Sackner MA. The respiratory inductive plethysmograph: A new non-invasive monitor of respiration. Bull Eur Physiopathol Respir. 1982;18:643–58.PubMed Cohn MA, Rao AS, Broudy M, Birch S, Watson H, Atkins N, Davis B, Stott FD, Sackner MA. The respiratory inductive plethysmograph: A new non-invasive monitor of respiration. Bull Eur Physiopathol Respir. 1982;18:643–58.PubMed
30.
go back to reference Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(41):2251–69.CrossRef Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(41):2251–69.CrossRef
32.
go back to reference Kamat DK, Bagul D, Patil PM (2014) Classification and application of bio-impedance measurement techniques. IJEIT 3(10) Kamat DK, Bagul D, Patil PM (2014) Classification and application of bio-impedance measurement techniques. IJEIT 3(10)
Metadata
Title
A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside
Authors
Salar Tayebi
Adrian Gutierrez
Ikram Mohout
Evelien Smets
Robert Wise
Johan Stiens
Manu L. N. G. Malbrain
Publication date
01-02-2021
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 1/2021
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00561-4

Other articles of this Issue 1/2021

Journal of Clinical Monitoring and Computing 1/2021 Go to the issue