Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 2/2018

01-04-2018 | Original Research

Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia

Authors: Kavita G. Morparia, Srijaya K. Reddy, Laura J. Olivieri, Michael C. Spaeder, Jennifer J. Schuette

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2018

Login to get access

Abstract

The determination of fluid responsiveness in the critically ill child is of vital importance, more so as fluid overload becomes increasingly associated with worse outcomes. Dynamic markers of volume responsiveness have shown some promise in the pediatric population, but more research is needed before they can be adopted for widespread use. Our aim was to investigate effectiveness of respiratory variation in peak aortic velocity and pulse pressure variation to predict fluid responsiveness, and determine their optimal cutoff values. We performed a prospective, observational study at a single tertiary care pediatric center. Twenty-one children with normal cardiorespiratory status undergoing general anesthesia for neurosurgery were enrolled. Respiratory variation in peak aortic velocity (ΔVpeak ao) was measured both before and after volume expansion using a bedside ultrasound device. Pulse pressure variation (PPV) value was obtained from the bedside monitor. All patients received a 10 ml/kg fluid bolus as volume expansion, and were qualified as responders if stroke volume increased >15% as a result. Utility of ΔVpeak ao and PPV and to predict responsiveness to volume expansion was investigated. A baseline ΔVpeak ao value of greater than or equal to 12.3% best predicted a positive response to volume expansion, with a sensitivity of 77%, specificity of 89% and area under receiver operating characteristic curve of 0.90. PPV failed to demonstrate utility in this patient population. Respiratory variation in peak aortic velocity is a promising marker for optimization of perioperative fluid therapy in the pediatric population and can be accurately measured using bedside ultrasonography. More research is needed to evaluate the lack of effectiveness of pulse pressure variation for this purpose.
Literature
1.
go back to reference Michard F, Boussat S, Chemla D, et al. Realationship between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134–8.CrossRefPubMed Michard F, Boussat S, Chemla D, et al. Realationship between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134–8.CrossRefPubMed
2.
go back to reference Kumar A, Anel R, Bunnell E, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9.CrossRefPubMed Kumar A, Anel R, Bunnell E, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med. 2004;32:691–9.CrossRefPubMed
3.
go back to reference Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed Osman D, Ridel C, Ray P, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed
4.
go back to reference Monnet X, Dres M, Ferre´ A, et al. Prediction of fluid responsiveness by a continuous noninvasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth. 2012;109:330–8.CrossRefPubMed Monnet X, Dres M, Ferre´ A, et al. Prediction of fluid responsiveness by a continuous noninvasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth. 2012;109:330–8.CrossRefPubMed
5.
go back to reference Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients. A critical analysis of the evidence. Chest. 2002;121:2000–8.CrossRefPubMed Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients. A critical analysis of the evidence. Chest. 2002;121:2000–8.CrossRefPubMed
6.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed
7.
go back to reference Perel A, Pizov R, Cotev S. Respiratory variations in the arterial pressure during mechanical ventilation reflect volume status and fluid responsiveness. Intensive Care Med. 2014;40:798–807.CrossRefPubMed Perel A, Pizov R, Cotev S. Respiratory variations in the arterial pressure during mechanical ventilation reflect volume status and fluid responsiveness. Intensive Care Med. 2014;40:798–807.CrossRefPubMed
8.
go back to reference Aboy M, McNames J, Thong T, et al. A novel algorithm to estimate the pulse pressure variation index delta PP. IEEE Trans Biomed Eng. 2004;51:2198–203.CrossRefPubMed Aboy M, McNames J, Thong T, et al. A novel algorithm to estimate the pulse pressure variation index delta PP. IEEE Trans Biomed Eng. 2004;51:2198–203.CrossRefPubMed
9.
go back to reference Cannesson M, Slieker J, Desebe O, et al. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg. 2008;106:1195–200.CrossRefPubMed Cannesson M, Slieker J, Desebe O, et al. The ability of a novel algorithm for automatic estimation of the respiratory variations in arterial pulse pressure to monitor fluid responsiveness in the operating room. Anesth Analg. 2008;106:1195–200.CrossRefPubMed
10.
go back to reference Mahjoub Y, Lorne E, Micaux Y, et al. Accuracy of automated continuous calculation of pulse pressure variation in critically ill patients. Intensive Care Med. 2011;37:360–1.CrossRefPubMed Mahjoub Y, Lorne E, Micaux Y, et al. Accuracy of automated continuous calculation of pulse pressure variation in critically ill patients. Intensive Care Med. 2011;37:360–1.CrossRefPubMed
11.
go back to reference Durand P, Chevret L, Essouri S, Haas V, Devictor D. Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med. 2008;34:888–94.CrossRefPubMed Durand P, Chevret L, Essouri S, Haas V, Devictor D. Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children. Intensive Care Med. 2008;34:888–94.CrossRefPubMed
12.
go back to reference DeBacker D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness; influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRef DeBacker D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness; influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRef
13.
go back to reference Choi D, Kwak H, Park H, Kim Y, Choi C, Lee J. Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol. 2010;31:1166–70.CrossRefPubMed Choi D, Kwak H, Park H, Kim Y, Choi C, Lee J. Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect. Pediatr Cardiol. 2010;31:1166–70.CrossRefPubMed
14.
go back to reference Renner J, Gruenewald M, Meybohm P, et. al. Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model. Pediatr Anesth. 2008;18:1170–7. Renner J, Gruenewald M, Meybohm P, et. al. Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model. Pediatr Anesth. 2008;18:1170–7.
15.
go back to reference Desgranges F-P, Desebbe O, Pereira de Souza Neto E, et al. Respiratory variation in aortic blood flow velocity to predict fluid responsiveness in mechanically ventilated children: a systematic review and meta-analysis. Pediatr Anesth. 2016;26:37–47.CrossRef Desgranges F-P, Desebbe O, Pereira de Souza Neto E, et al. Respiratory variation in aortic blood flow velocity to predict fluid responsiveness in mechanically ventilated children: a systematic review and meta-analysis. Pediatr Anesth. 2016;26:37–47.CrossRef
16.
go back to reference Cecconi M, Corredor C, Arulkumaran N, et al. Clinical review: goal-directed therapy—what is the evidence in surgical patients? The effect on different risk groups. Crit Care. 2013;17:209.CrossRefPubMedPubMedCentral Cecconi M, Corredor C, Arulkumaran N, et al. Clinical review: goal-directed therapy—what is the evidence in surgical patients? The effect on different risk groups. Crit Care. 2013;17:209.CrossRefPubMedPubMedCentral
17.
go back to reference Gan H, Cannesson M, Chandler J, Anserimo J. Predicting fluid responsiveness in children: a systematic review. Anesth Analg. 2013;117:1380–92.CrossRefPubMed Gan H, Cannesson M, Chandler J, Anserimo J. Predicting fluid responsiveness in children: a systematic review. Anesth Analg. 2013;117:1380–92.CrossRefPubMed
18.
go back to reference Sproul A, Simpson E. Stroke volume and related hemodynamic data in normal children. Paediatrics. 1964;33:912–8. Sproul A, Simpson E. Stroke volume and related hemodynamic data in normal children. Paediatrics. 1964;33:912–8.
19.
go back to reference Bilchick K, Wise R. Paradoxical physical findings described by Kussmaul: pulsus paradoxus and Kussmaul’s sign. Lancet. 2002;359:1940–2.CrossRefPubMed Bilchick K, Wise R. Paradoxical physical findings described by Kussmaul: pulsus paradoxus and Kussmaul’s sign. Lancet. 2002;359:1940–2.CrossRefPubMed
20.
go back to reference Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 1987;67:498–502.CrossRefPubMed Perel A, Pizov R, Cotev S. Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology. 1987;67:498–502.CrossRefPubMed
21.
go back to reference Cannesson M, Aboy M, Hofer C, Rehman M. Pulse pressure variation: where are we today? J Clin Monit Comput. 2011;25:45–56.CrossRefPubMed Cannesson M, Aboy M, Hofer C, Rehman M. Pulse pressure variation: where are we today? J Clin Monit Comput. 2011;25:45–56.CrossRefPubMed
22.
go back to reference Marik P, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed Marik P, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed
23.
go back to reference Pereira de Souza Neto E, Grousson S, Duflo F, et al. Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth. 2011;106:856–64.CrossRef Pereira de Souza Neto E, Grousson S, Duflo F, et al. Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. Br J Anaesth. 2011;106:856–64.CrossRef
24.
go back to reference Byon H, Lim C, Lee J, et al. Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery. Br J Anaesth. 2013;110:586–91.CrossRefPubMed Byon H, Lim C, Lee J, et al. Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery. Br J Anaesth. 2013;110:586–91.CrossRefPubMed
25.
go back to reference Senzaki H, Akagi M, Hishi T, et al. Age-associated changes in arterial elastic properties in children. Eur J Pediatr. 2002;161:547–51.CrossRefPubMed Senzaki H, Akagi M, Hishi T, et al. Age-associated changes in arterial elastic properties in children. Eur J Pediatr. 2002;161:547–51.CrossRefPubMed
Metadata
Title
Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia
Authors
Kavita G. Morparia
Srijaya K. Reddy
Laura J. Olivieri
Michael C. Spaeder
Jennifer J. Schuette
Publication date
01-04-2018
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2018
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0013-3

Other articles of this Issue 2/2018

Journal of Clinical Monitoring and Computing 2/2018 Go to the issue