Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 1/2016

01-02-2016 | Original Research

A multi-channel acoustics monitor for perioperative respiratory monitoring: preliminary data

Authors: Kamal Jafarian, Majid Amineslami, Kamran Hassani, Mahdi Navidbakhsh, Mohammad Niakan Lahiji, D. John Doyle

Published in: Journal of Clinical Monitoring and Computing | Issue 1/2016

Login to get access

Abstract

This study pertains to a six-channel acoustic monitoring system for use in patient monitoring during or after surgery. The base hardware consists of a USB data acquisition system, a custom-built six-channel amplification system, and a series of microphones of various designs. The software is based on the MATLAB platform with data acquisition drivers installed. The displayed information includes: time domain signals, frequency domain signals, and tools to aid in the detection of endobronchial intubation. We hypothesize that the above mentioned arrangement may be helpful to the anesthesiologist in recognizing clinical conditions like wheezing, bronchospasm, endobronchial intubation, and apnea. The study also evaluated various types of microphone designs used to transduce breath sounds. The system also features selectable band-pass filtering using MATLAB algorithms as well as a collection of recordings obtained with the system to establish what respiratory acoustic signals look like under various conditions.
Literature
1.
go back to reference Brochard L, Martin GS, Blanch L, Pelosi P, Belda FJ, Jubran A, Gattinoni L, Mancebo J, Ranieri VM, Richard JC, Gommers D, Vieillard-Baron A, Pesenti A, Jaber S, Stenqvist O, Vincent JL. Clinical review: respiratory monitoring in the ICU—a consensus of 16. Crit Care. 2012;16(2):219.PubMedCentralCrossRefPubMed Brochard L, Martin GS, Blanch L, Pelosi P, Belda FJ, Jubran A, Gattinoni L, Mancebo J, Ranieri VM, Richard JC, Gommers D, Vieillard-Baron A, Pesenti A, Jaber S, Stenqvist O, Vincent JL. Clinical review: respiratory monitoring in the ICU—a consensus of 16. Crit Care. 2012;16(2):219.PubMedCentralCrossRefPubMed
2.
go back to reference Tobin MJ. Respiratory monitoring in the intensive care unit. Am Rev Respir Dis. 1988;138:1625–42.CrossRefPubMed Tobin MJ. Respiratory monitoring in the intensive care unit. Am Rev Respir Dis. 1988;138:1625–42.CrossRefPubMed
3.
go back to reference Alshaer H, Fernie GR, Bradley TD. Monitoring of breathing phases using a bioacoustic method in healthy awake subjects. J Clin Monit Comput. 2011;25(5):285–94.CrossRefPubMed Alshaer H, Fernie GR, Bradley TD. Monitoring of breathing phases using a bioacoustic method in healthy awake subjects. J Clin Monit Comput. 2011;25(5):285–94.CrossRefPubMed
4.
go back to reference Alshaer H, Fernie GR, Bradley TD. Phase tracking of the breathing cycle in sleeping subjects by frequency analysis of acoustic data. Int J Healthc Technol Manag. 2010;11:163–75.CrossRef Alshaer H, Fernie GR, Bradley TD. Phase tracking of the breathing cycle in sleeping subjects by frequency analysis of acoustic data. Int J Healthc Technol Manag. 2010;11:163–75.CrossRef
5.
go back to reference Buhre W, Rossaint R. Perioperative management and monitoring in anaesthesia. Lancet. 2003;362(9398):1839–46.CrossRefPubMed Buhre W, Rossaint R. Perioperative management and monitoring in anaesthesia. Lancet. 2003;362(9398):1839–46.CrossRefPubMed
6.
go back to reference Mertzlufft F, Zander R. Perioperative respiratory monitoring of oxygen transport. Infusionsther Transfusionsmed. 1993;20(4):180–4.PubMed Mertzlufft F, Zander R. Perioperative respiratory monitoring of oxygen transport. Infusionsther Transfusionsmed. 1993;20(4):180–4.PubMed
7.
go back to reference Xiong C, Hok B, Stromberg T, Loyd D, Wranne B, Ask P. A bioacoustic method for timing of respiration at cardiac investigations. Clin Physiol. 1995;15:151–7.CrossRefPubMed Xiong C, Hok B, Stromberg T, Loyd D, Wranne B, Ask P. A bioacoustic method for timing of respiration at cardiac investigations. Clin Physiol. 1995;15:151–7.CrossRefPubMed
8.
go back to reference Hult P, Fjallbrant T, Wranne B, Engdahl O, Ask P. An improved bioacoustic method for monitoring of respiration. Technol Health Care. 2004;12:323–32.PubMed Hult P, Fjallbrant T, Wranne B, Engdahl O, Ask P. An improved bioacoustic method for monitoring of respiration. Technol Health Care. 2004;12:323–32.PubMed
9.
go back to reference Hult P, Wranne B, Ask P. A bioacoustic method for timing of the different phases of the breathing cycle and monitoring of breathing frequency. Med Eng Phys. 2000;22:425–33.CrossRefPubMed Hult P, Wranne B, Ask P. A bioacoustic method for timing of the different phases of the breathing cycle and monitoring of breathing frequency. Med Eng Phys. 2000;22:425–33.CrossRefPubMed
10.
go back to reference Sen I, Kahya Y. A multi-channel device for respiratory sound data acquisition and transient detection. Conf Proc IEEE Eng Med Biol Soc. 2005;6:6658–61.PubMed Sen I, Kahya Y. A multi-channel device for respiratory sound data acquisition and transient detection. Conf Proc IEEE Eng Med Biol Soc. 2005;6:6658–61.PubMed
11.
go back to reference Loudon R, Murphy R. Lung sounds. Am Rev Respir Dis. 1984;130:663–73.PubMed Loudon R, Murphy R. Lung sounds. Am Rev Respir Dis. 1984;130:663–73.PubMed
12.
go back to reference Sankur B, Kahya YP, Guler EC, Engin T. Comparison of AR-based algorithms for respiratory sounds classification. Comput Biol Med. 1994;24:67–76.CrossRefPubMed Sankur B, Kahya YP, Guler EC, Engin T. Comparison of AR-based algorithms for respiratory sounds classification. Comput Biol Med. 1994;24:67–76.CrossRefPubMed
13.
go back to reference Guler EC, Sankur B, Kahya YP, Raudys S. Two-stage classification of respiratory sound patterns. Comput Biol Med. 2005;35:67–83.CrossRefPubMed Guler EC, Sankur B, Kahya YP, Raudys S. Two-stage classification of respiratory sound patterns. Comput Biol Med. 2005;35:67–83.CrossRefPubMed
14.
go back to reference Sahgal N. Monitoring and analysis of lung sounds remotely. Int J Chron Obstr Pulm Dis. 2011;6:407–12.CrossRef Sahgal N. Monitoring and analysis of lung sounds remotely. Int J Chron Obstr Pulm Dis. 2011;6:407–12.CrossRef
15.
go back to reference Beck R, Rosenhouse G, Mahagnah M, Chow RM, Cugell DW, Gavriely N. Measurements and theory of normal tracheal breath sounds. Ann Biomed Eng. 2005;33:1344–51.CrossRefPubMed Beck R, Rosenhouse G, Mahagnah M, Chow RM, Cugell DW, Gavriely N. Measurements and theory of normal tracheal breath sounds. Ann Biomed Eng. 2005;33:1344–51.CrossRefPubMed
16.
go back to reference Sierra G, Telfort V, Popov B, Durand LG, Agarwal R, Lanzo V. Monitoring respiratory rate based on tracheal sounds. First experiences. Conf Proc IEEE Eng Med Biol Soc. 2004;1:317–20.PubMed Sierra G, Telfort V, Popov B, Durand LG, Agarwal R, Lanzo V. Monitoring respiratory rate based on tracheal sounds. First experiences. Conf Proc IEEE Eng Med Biol Soc. 2004;1:317–20.PubMed
17.
go back to reference Yadollahi A, Moussavi ZM. A robust method for estimating respiratory flow using tracheal sounds entropy. IEEE Trans Biomed Eng. 2006;53:662–8.CrossRefPubMed Yadollahi A, Moussavi ZM. A robust method for estimating respiratory flow using tracheal sounds entropy. IEEE Trans Biomed Eng. 2006;53:662–8.CrossRefPubMed
18.
go back to reference Yadollahi A, Moussavi ZM. Acoustical respiratory flow. A review of reliable methods for measuring air flow. IEEE Eng Med Biol Mag. 2007;26:56–61.CrossRefPubMed Yadollahi A, Moussavi ZM. Acoustical respiratory flow. A review of reliable methods for measuring air flow. IEEE Eng Med Biol Mag. 2007;26:56–61.CrossRefPubMed
19.
go back to reference Nakano H, Hayashi M, Ohshima E, Nishikata N, Shinohara T. Validation of a new system of tracheal sound analysis for the diagnosis of sleep apnea-hypopnea syndrome. Sleep. 2004;27:951–7.PubMed Nakano H, Hayashi M, Ohshima E, Nishikata N, Shinohara T. Validation of a new system of tracheal sound analysis for the diagnosis of sleep apnea-hypopnea syndrome. Sleep. 2004;27:951–7.PubMed
20.
go back to reference Yadollahi A, Giannouli E, Moussavi Z. Sleep apnea monitoring and diagnosis based on pulse oximetry and tracheal sound signals. Med Biol Eng Comput. 2010;48:1087–97.CrossRefPubMed Yadollahi A, Giannouli E, Moussavi Z. Sleep apnea monitoring and diagnosis based on pulse oximetry and tracheal sound signals. Med Biol Eng Comput. 2010;48:1087–97.CrossRefPubMed
21.
go back to reference Yu L, Ting CK, Hill BE, Orr JA, Brewer LM, Johnson KB, Egan TD, Westenskow DR. Using the entropy of tracheal sounds to detect apnea during sedation in healthy nonobese volunteers. Anesthesiology. 2013;118:1341–9.CrossRefPubMed Yu L, Ting CK, Hill BE, Orr JA, Brewer LM, Johnson KB, Egan TD, Westenskow DR. Using the entropy of tracheal sounds to detect apnea during sedation in healthy nonobese volunteers. Anesthesiology. 2013;118:1341–9.CrossRefPubMed
22.
go back to reference Ahlstrom C, Johansson A, Hult P, Ask P. Chaotic dynamics of respiratory sounds. Chaos Solitons Fractals. 2006;29:1054–62.CrossRef Ahlstrom C, Johansson A, Hult P, Ask P. Chaotic dynamics of respiratory sounds. Chaos Solitons Fractals. 2006;29:1054–62.CrossRef
24.
go back to reference Sun S, Wang H, Jiang Z, Fang Y, Tao T. Segmentation-based heart sound feature extraction combined with classifier models for a VSD diagnosis system. Expert Syst Appl. 2014;41:1769–80.CrossRef Sun S, Wang H, Jiang Z, Fang Y, Tao T. Segmentation-based heart sound feature extraction combined with classifier models for a VSD diagnosis system. Expert Syst Appl. 2014;41:1769–80.CrossRef
25.
go back to reference Ahlstrom C, Liljefeldt O, Hult P, Ask P. Heart sound cancellation from lung sound recordings using recurrence time statistics and nonlinear prediction. IEEE Signal Process Lett. 2005;12:812–5.CrossRef Ahlstrom C, Liljefeldt O, Hult P, Ask P. Heart sound cancellation from lung sound recordings using recurrence time statistics and nonlinear prediction. IEEE Signal Process Lett. 2005;12:812–5.CrossRef
26.
go back to reference George JA, Lin EE, Hanna MN, Murphy JD, Kumar K, Ko PS, Wu CL. The effect of intravenous opioid patient-controlled analgesia with and without background infusion on respiratory depression: a meta-analysis. J Opioid Manag. 2010;6:47–54.CrossRefPubMed George JA, Lin EE, Hanna MN, Murphy JD, Kumar K, Ko PS, Wu CL. The effect of intravenous opioid patient-controlled analgesia with and without background infusion on respiratory depression: a meta-analysis. J Opioid Manag. 2010;6:47–54.CrossRefPubMed
27.
go back to reference Kasuya Y, Akça O, Sessler DI, Ozaki M, Komatsu R. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology. 2009;111:609–15.CrossRefPubMed Kasuya Y, Akça O, Sessler DI, Ozaki M, Komatsu R. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology. 2009;111:609–15.CrossRefPubMed
28.
go back to reference Maddox RR, Williams CK, Oglesby H, Butler B, Colclasure B. Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion system. Am J Health Syst Pharm. 2006;63:157–64.CrossRefPubMed Maddox RR, Williams CK, Oglesby H, Butler B, Colclasure B. Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion system. Am J Health Syst Pharm. 2006;63:157–64.CrossRefPubMed
29.
go back to reference Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69–75.CrossRefPubMed Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69–75.CrossRefPubMed
30.
go back to reference Ramezani R, Doyle DJ, Navidbakhsh M, Hassani K, Torabiyan H. A color spectrographic phonocardiography (CSP) applied to the detection and characterization of heart murmurs: preliminary results. BioMed Eng OnLine. 2011;10:42.CrossRef Ramezani R, Doyle DJ, Navidbakhsh M, Hassani K, Torabiyan H. A color spectrographic phonocardiography (CSP) applied to the detection and characterization of heart murmurs: preliminary results. BioMed Eng OnLine. 2011;10:42.CrossRef
31.
go back to reference Kansara M, Chapatwala N. Noise reduction from the speech signal using wavelet packet transform. Int J Electron Comput Sci Eng. 2013;2:2. Kansara M, Chapatwala N. Noise reduction from the speech signal using wavelet packet transform. Int J Electron Comput Sci Eng. 2013;2:2.
32.
go back to reference Zhang Y, Chen S, Wu J, Luo Y. Remote heart sound and lung sound monitoring system design based on ZigBee. In: 5th International conference on BioMedical Engineering and Informatics. 2012. Zhang Y, Chen S, Wu J, Luo Y. Remote heart sound and lung sound monitoring system design based on ZigBee. In: 5th International conference on BioMedical Engineering and Informatics. 2012.
33.
go back to reference Doyle DJ, Nair B. Revisiting the video stethoscope: an application of digital signal processing software (Goldwave) to monitoring ventilation in intubated patients. Conf Proc IEEE Eng Med Biol Soc. 2009;2009:6251–4. doi:10.1109/IEMBS.2009.5334665.PubMed Doyle DJ, Nair B. Revisiting the video stethoscope: an application of digital signal processing software (Goldwave) to monitoring ventilation in intubated patients. Conf Proc IEEE Eng Med Biol Soc. 2009;2009:6251–4. doi:10.​1109/​IEMBS.​2009.​5334665.PubMed
Metadata
Title
A multi-channel acoustics monitor for perioperative respiratory monitoring: preliminary data
Authors
Kamal Jafarian
Majid Amineslami
Kamran Hassani
Mahdi Navidbakhsh
Mohammad Niakan Lahiji
D. John Doyle
Publication date
01-02-2016
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 1/2016
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9693-8

Other articles of this Issue 1/2016