01-06-2013 | Review Paper

Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care

Authors: Amit Shah, Kirk H. Shelley

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2013

Login to get access

Abstract

Since the discovery of anesthetic agents, patient monitoring has been considered one of the core responsibilities of the anesthesiologist. As depicted in Robert Hinckley’s famous painting, The First Operation with Ether, one observes William Thomas Green Morton carefully watching over his patient. Since its founding in 1905, ‘Vigilance’ has been the motto of the American Society of Anesthesiologists (ASA). Over a hundred years have passed, and one would think we would be clear regarding what we are watching for and how we should be watching. On the contrary, the introduction of new technology and outcome research is requiring us to re-examine our fundamental assumptions regarding what is and what is not important in the care of the patient. A vast majority of anesthesiologists would refuse to proceed with an anesthetic without the presence of a pulse oximeter. On the other hand, outcome studies have failed to demonstrate an improvement in patient care with their use. For that matter, it can be argued that outcome studies have yet to demonstrate an unambiguous role for any monitor of any type (i.e. blood pressure cuff or ECG), as outcome studies may fail to capture rare events. Because of the increased safety that has been attributed to pulse oximetry, it is unlikely that further studies can or will be conducted. As we enter a new era of clinical monitoring, with an emphasis on noninvasive cardiovascular monitoring, it might be of benefit to examine the role of the pulse oximeter in clinical care. This article reviews the available evidence for pulse oximetry. Further, it discusses contemporary issues, events, and perceptions that may help to explain how and why pulse oximetry may have been adopted as a standard of care despite the lack of supportive. Lastly, it discusses less obvious benefits of pulse oximetry that may have further implications on the future of anesthesia care and perhaps even automated anesthesia.
Literature
1.
2.
3.
go back to reference Barash P, et al. Clin Anesth. 6th ed. Philadelphia: Lippincott, Williams, and Wilkins; 2009. Barash P, et al. Clin Anesth. 6th ed. Philadelphia: Lippincott, Williams, and Wilkins; 2009.
4.
go back to reference Wukitsch MW. Pulse oximetry: historical review and Ohmeda functional analysis. Int J Clin Monit Comput. 1987;4:161–6.PubMedCrossRef Wukitsch MW. Pulse oximetry: historical review and Ohmeda functional analysis. Int J Clin Monit Comput. 1987;4:161–6.PubMedCrossRef
5.
go back to reference Merry A. Role of anesthesiologists in WHO safe surgery programs. Int Anesthesiol Clin. 2010;48(2):137–50.PubMedCrossRef Merry A. Role of anesthesiologists in WHO safe surgery programs. Int Anesthesiol Clin. 2010;48(2):137–50.PubMedCrossRef
6.
go back to reference Thoms G, McHugh GA, O’Sullivan E. The global oximetry initiative. Anaesthesia. 2007;62(s1):75–7.PubMedCrossRef Thoms G, McHugh GA, O’Sullivan E. The global oximetry initiative. Anaesthesia. 2007;62(s1):75–7.PubMedCrossRef
7.
go back to reference Tinker J, et al. Role of monitoring devices in prevention of anesthetic mishaps: a closed claims analysis. Anesthesiology. 1989;71:541–6.PubMedCrossRef Tinker J, et al. Role of monitoring devices in prevention of anesthetic mishaps: a closed claims analysis. Anesthesiology. 1989;71:541–6.PubMedCrossRef
8.
go back to reference Eichhorn J. Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring. Anesthesiology. 1989;70(4):572–7.PubMedCrossRef Eichhorn J. Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring. Anesthesiology. 1989;70(4):572–7.PubMedCrossRef
9.
go back to reference Cullen D, et al. Effect of pulse oximetry, age, and ASA physical status on the frequency of patients admitted unexpectedly to a postoperative intensive care unit and the severity of their anesthesia-related complications. Anesth Analg. 1992;74(2):181–8.PubMedCrossRef Cullen D, et al. Effect of pulse oximetry, age, and ASA physical status on the frequency of patients admitted unexpectedly to a postoperative intensive care unit and the severity of their anesthesia-related complications. Anesth Analg. 1992;74(2):181–8.PubMedCrossRef
11.
go back to reference Raemer D, et al. Hypoxemia during ambulatory gynecologic surgery as evaluated by the pulse oximeter. J Clin Monit. 1987;3(4):244–8.PubMed Raemer D, et al. Hypoxemia during ambulatory gynecologic surgery as evaluated by the pulse oximeter. J Clin Monit. 1987;3(4):244–8.PubMed
12.
go back to reference Caplan R, et al. Unexpected cardiac arrest during spinal anesthesia: a closed claims analysis of predisposing factors. Anesthesiology. 1988;68:5–11.PubMedCrossRef Caplan R, et al. Unexpected cardiac arrest during spinal anesthesia: a closed claims analysis of predisposing factors. Anesthesiology. 1988;68:5–11.PubMedCrossRef
13.
go back to reference Pedersen T, Moller A, Pedersen B. Pulse oximetry for perioperative monitoring: systemic review of randomized, controlled trials. Anesth Analg. 2003;96(2):426–31.PubMed Pedersen T, Moller A, Pedersen B. Pulse oximetry for perioperative monitoring: systemic review of randomized, controlled trials. Anesth Analg. 2003;96(2):426–31.PubMed
14.
go back to reference Pedersen T, Hovhannisyan K, Moller A. Pulse oximetry for perioperative monitoring. Cochrane Database of Systematic Reviews 2009, 2009(4). Pedersen T, Hovhannisyan K, Moller A. Pulse oximetry for perioperative monitoring. Cochrane Database of Systematic Reviews 2009, 2009(4).
15.
go back to reference Moller JT, Jensen PF, Johannessen NW, Espersen K. Hypoxaemia is reduced by pulse oximetry monitoring in the operating theatre and in the recovery room. Br J Anaesth. 1992;68(2):146–150. Moller JT, Jensen PF, Johannessen NW, Espersen K. Hypoxaemia is reduced by pulse oximetry monitoring in the operating theatre and in the recovery room. Br J Anaesth. 1992;68(2):146–150.
16.
go back to reference Moller J, et al. Randomized evaluation of pulse oximetry in 20,802 patients: II. Perioperative events and postoperative complications. Anesthesiology. 1993;78(3):445–53.PubMedCrossRef Moller J, et al. Randomized evaluation of pulse oximetry in 20,802 patients: II. Perioperative events and postoperative complications. Anesthesiology. 1993;78(3):445–53.PubMedCrossRef
17.
go back to reference Moller J, et al. Randomized evaluation of pulse oximetry in 20,802 patients: I. Design, demography, pulse oximetry failure rate, and overall complication rate. Anesthesiology. 1993;78(3):445–53.PubMedCrossRef Moller J, et al. Randomized evaluation of pulse oximetry in 20,802 patients: I. Design, demography, pulse oximetry failure rate, and overall complication rate. Anesthesiology. 1993;78(3):445–53.PubMedCrossRef
18.
go back to reference Bierman M, Stein K, Snyder J. Pulse oximetry in the postoperative care of cardiac surgical patients. A randomized controlled trial. Chest. 1992;102(5):1367–70.PubMedCrossRef Bierman M, Stein K, Snyder J. Pulse oximetry in the postoperative care of cardiac surgical patients. A randomized controlled trial. Chest. 1992;102(5):1367–70.PubMedCrossRef
19.
go back to reference Ochroch E, et al. The impact of continuous pulse oximetry monitoring on intensive care unit admissions from a postsurgical care floor. Anesth Analg. 2006;102(3):868–75.PubMedCrossRef Ochroch E, et al. The impact of continuous pulse oximetry monitoring on intensive care unit admissions from a postsurgical care floor. Anesth Analg. 2006;102(3):868–75.PubMedCrossRef
20.
go back to reference Moller J, et al. Perioperative monitoring with pulse oximetry and late postoperative cognitive dysfunction. Br J Anaesth. 1993;71(3):340–7.PubMedCrossRef Moller J, et al. Perioperative monitoring with pulse oximetry and late postoperative cognitive dysfunction. Br J Anaesth. 1993;71(3):340–7.PubMedCrossRef
21.
go back to reference Cooper J, et al. Effects of information feedback and pulse oximetry on the incidence of anesthesia complications. Anesthesiology. 1987;67(5):686–94.PubMedCrossRef Cooper J, et al. Effects of information feedback and pulse oximetry on the incidence of anesthesia complications. Anesthesiology. 1987;67(5):686–94.PubMedCrossRef
22.
go back to reference Pierce E. ASA monitoring guidelines: their origin and development. ASA Newsletter 2002;66(9):22–23. Pierce E. ASA monitoring guidelines: their origin and development. ASA Newsletter 2002;66(9):22–23.
23.
go back to reference Islam S, Auerbach A. The impact of intraoperative monitoring on patient safety. In: Markowitz A, editor. Making health care safer: a critical analysis of patient safety practices. Rockville: Agency for Healthcare Research and Quality US Department of Health and Human Services; 2001. p. 265–70. Islam S, Auerbach A. The impact of intraoperative monitoring on patient safety. In: Markowitz A, editor. Making health care safer: a critical analysis of patient safety practices. Rockville: Agency for Healthcare Research and Quality US Department of Health and Human Services; 2001. p. 265–70.
24.
go back to reference Pierce E. The 34th Rovenstine Lecture: 40 years beind the mask: safety revisited. Anesthesiology. 1996;84(4):965–75.PubMedCrossRef Pierce E. The 34th Rovenstine Lecture: 40 years beind the mask: safety revisited. Anesthesiology. 1996;84(4):965–75.PubMedCrossRef
25.
go back to reference Smith G, Pell J. Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomised controlled trials. Br Med J. 2003;327:1459–61.CrossRef Smith G, Pell J. Parachute use to prevent death and major trauma related to gravitational challenge: systematic review of randomised controlled trials. Br Med J. 2003;327:1459–61.CrossRef
26.
go back to reference Keats A. The Rovenstine Lecture, 1983: cardiovascular anesthesia: perceptions and perspectives. Anesthesiology. 1984;60(5):467–74.PubMedCrossRef Keats A. The Rovenstine Lecture, 1983: cardiovascular anesthesia: perceptions and perspectives. Anesthesiology. 1984;60(5):467–74.PubMedCrossRef
27.
go back to reference Joseph V, Lagasse R. Monitoring and analysis of outcome studies. Int Anesthesiol Clin. 2004;42(2):113–30.PubMedCrossRef Joseph V, Lagasse R. Monitoring and analysis of outcome studies. Int Anesthesiol Clin. 2004;42(2):113–30.PubMedCrossRef
28.
go back to reference Cohen M, et al. A survey of 112,000 anaesthetics at one teaching hospital. Can J Anesth. 1986;33(1):22–31.CrossRef Cohen M, et al. A survey of 112,000 anaesthetics at one teaching hospital. Can J Anesth. 1986;33(1):22–31.CrossRef
29.
go back to reference Petterson M, Begnoche V, Graybeal J. The effect of motion on pulse oximetry and its clinical significance. Anesth Analg. 2007;105(6):s78–84.PubMedCrossRef Petterson M, Begnoche V, Graybeal J. The effect of motion on pulse oximetry and its clinical significance. Anesth Analg. 2007;105(6):s78–84.PubMedCrossRef
30.
go back to reference Kay J, Neal M. Effect of automatic blood pressure devices on vigilance of anesthesia residents. J Clin Monit Comput. 1986;2(3):148–50. Kay J, Neal M. Effect of automatic blood pressure devices on vigilance of anesthesia residents. J Clin Monit Comput. 1986;2(3):148–50.
31.
go back to reference Guan Z, Baker K, Sandberg W. Misalignment of disposable pulse oximeter probes results in false saturation readings that influence anesthetic management. Anesth Analg. 2009;109(5):1530–3.PubMedCrossRef Guan Z, Baker K, Sandberg W. Misalignment of disposable pulse oximeter probes results in false saturation readings that influence anesthetic management. Anesth Analg. 2009;109(5):1530–3.PubMedCrossRef
32.
go back to reference Agashe G, Coakley J, Mannheimer P. Forehead pulse oximetry: headband use helps alleviate false low readings likely related to venous pulsation artifact. Anesthesiology. 2006;105(6):1075–7.CrossRef Agashe G, Coakley J, Mannheimer P. Forehead pulse oximetry: headband use helps alleviate false low readings likely related to venous pulsation artifact. Anesthesiology. 2006;105(6):1075–7.CrossRef
33.
go back to reference Shelley K, et al. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in SpO2 calculation. Anesth Analg. 2005;100:743–7.PubMedCrossRef Shelley K, et al. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in SpO2 calculation. Anesth Analg. 2005;100:743–7.PubMedCrossRef
34.
go back to reference Feiner J, Severinghaus J, Bickler P. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth Analg. 2007;165(65):S18–23.CrossRef Feiner J, Severinghaus J, Bickler P. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth Analg. 2007;165(65):S18–23.CrossRef
35.
go back to reference Reuss J, Siker D. The pulse in reflectance pulse oximetry: modeling and experimental studies. J Clin Monit Comput. 2004;18(4):289–99.PubMedCrossRef Reuss J, Siker D. The pulse in reflectance pulse oximetry: modeling and experimental studies. J Clin Monit Comput. 2004;18(4):289–99.PubMedCrossRef
36.
go back to reference Fu E, et al. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126(5):1552–8.PubMedCrossRef Fu E, et al. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126(5):1552–8.PubMedCrossRef
38.
go back to reference Silber J, et al. Anesthesiologist direction and patient outcomes. Anesthesiology. 2000;93(1):152–63.PubMedCrossRef Silber J, et al. Anesthesiologist direction and patient outcomes. Anesthesiology. 2000;93(1):152–63.PubMedCrossRef
39.
go back to reference Heringlake M, et al. Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery. Anesthesiology. 2011;114(1):58–69.PubMedCrossRef Heringlake M, et al. Preoperative cerebral oxygen saturation and clinical outcomes in cardiac surgery. Anesthesiology. 2011;114(1):58–69.PubMedCrossRef
40.
go back to reference Shelley K. Is the automation of anesthesia possible or even desirable? Curr Opin in Anaesthesiol. 2008;21:748–9.CrossRef Shelley K. Is the automation of anesthesia possible or even desirable? Curr Opin in Anaesthesiol. 2008;21:748–9.CrossRef
Metadata
Title
Is pulse oximetry an essential tool or just another distraction? The role of the pulse oximeter in modern anesthesia care
Authors
Amit Shah
Kirk H. Shelley
Publication date
01-06-2013
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2013
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-013-9428-7

Other articles of this Issue 3/2013

Journal of Clinical Monitoring and Computing 3/2013 Go to the issue