01-06-2013 | Original Research

Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring

Authors: Bala G. Nair, Mayumi Horibe, Shu-Fang Newman, Wei-Ying Wu, Howard A. Schwid

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2013

Login to get access

Abstract

Blood pressure monitoring during anesthesia is an American Society of Anesthesiology standard. However, the anesthesia provider sometimes fails to engage the patient monitor to make periodic (generally every 3–5 min) measurements of Non-Invasive Blood Pressure (NIBP), which can lead to extended periods (>5 min) when blood pressure is not monitored. We describe a system to automatically detect such gaps in NIBP measurement and notify clinicians in real-time to initiate measurement. We applied a decision support system called the Smart Anesthesia Messenger (SAM) to notify the anesthesia provider if NIBP measurements have not been made in the last 7 min. Notification messages were generated only if direct arterial blood pressure was not being monitored. NIBP gaps were analyzed for 9 months before and after SAM notification was initiated (12,000 cases for each period). SAM notification was able to reduce the occurrence of extended NIBP gaps >15 min from 15.7 ± 4.5 to 6.7 ± 2.0 instances per 1,000 cases (p < 0.001). In addition, for extended gaps (>15 min) the mean gap duration declined from 23.1 ± 2.0 to 18.6 ± 1.1 min after SAM notification was initiated (p < 0.001). However, for 7–15 min gaps, SAM notification was not effective in reducing the occurrence. The maximum gap encountered before SAM was 64 min, while it was 27 min with SAM notification. Real-time notification using SAM is an effective way to reduce both the number of instances and the duration of inadvertent, extended (>15 min) gaps in blood pressure measurements in the operating room. However, the frequency of gaps <15 min could not be reduced using the current configuration of SAM.
Literature
3.
go back to reference Salgar V, Hartmannsgruber MWB, Silverman DG, Swamidoss CP, Bell C. False reliance on “Old” non-invasive blood pressure (NIBP) readings: human error or faulty design? J Clin Monit Comput. 2000;16:55. doi:10.1023/A:1017221530238. Salgar V, Hartmannsgruber MWB, Silverman DG, Swamidoss CP, Bell C. False reliance on “Old” non-invasive blood pressure (NIBP) readings: human error or faulty design? J Clin Monit Comput. 2000;16:55. doi:10.​1023/​A:​1017221530238.
6.
go back to reference Ehrenfeld JM, Epstein RH, Bader S, Kheterpal S, Sandberg WS. Automatic notifications mediated by anesthesia information management systems reduce the frequency of prolonged gaps in blood pressure documentation. Anesth Analg. 2011;113:356–63. doi:10.1213/ANE.0b013e31820d95e7.PubMedCrossRef Ehrenfeld JM, Epstein RH, Bader S, Kheterpal S, Sandberg WS. Automatic notifications mediated by anesthesia information management systems reduce the frequency of prolonged gaps in blood pressure documentation. Anesth Analg. 2011;113:356–63. doi:10.​1213/​ANE.​0b013e31820d95e7​.PubMedCrossRef
8.
go back to reference Nair BG, Newman S, Peterson GN, Wu W, Schwid HA. Feedback mechanisms including real-time electronic alerts to achieve near 100 % timely prophylactic antibiotic administration in surgical cases. Anesth Analg. 2010;111:1293–300. doi:10.1213/ANE.0b013e3181f46d89.PubMedCrossRef Nair BG, Newman S, Peterson GN, Wu W, Schwid HA. Feedback mechanisms including real-time electronic alerts to achieve near 100 % timely prophylactic antibiotic administration in surgical cases. Anesth Analg. 2010;111:1293–300. doi:10.​1213/​ANE.​0b013e3181f46d89​.PubMedCrossRef
9.
go back to reference Nair BG, Newman S, Peterson GN, Schwid HA. Automated electronic reminders to improve redosing of antibiotics during surgical cases: comparison of two approaches. Surg Infect. 2011;12:57–63. doi:10.1089/sur.2010.047.CrossRef Nair BG, Newman S, Peterson GN, Schwid HA. Automated electronic reminders to improve redosing of antibiotics during surgical cases: comparison of two approaches. Surg Infect. 2011;12:57–63. doi:10.​1089/​sur.​2010.​047.CrossRef
10.
go back to reference Nair BG, Peterson GN, Newman S, Wu W, Kolios-Morris V, Schwid HA. Improved documentation of β-blocker quality measure through anesthesia information management system and real-time notification of documentation errors. Jt Comm J Qual Saf. 2012;38:283–8. Nair BG, Peterson GN, Newman S, Wu W, Kolios-Morris V, Schwid HA. Improved documentation of β-blocker quality measure through anesthesia information management system and real-time notification of documentation errors. Jt Comm J Qual Saf. 2012;38:283–8.
11.
go back to reference Sandberg WS, Sandberg EH, Seim AR, Anupama S, Ehrenfeld JM, Spring SF, Walsh JL. Real-time checking of electronic anesthesia records for documentation errors and automatically text messaging clinicians improves quality of documentation. Anesth Analg. 2008;106:192–201. doi:10.1213/01.ane.0000289640.38523.bc.PubMedCrossRef Sandberg WS, Sandberg EH, Seim AR, Anupama S, Ehrenfeld JM, Spring SF, Walsh JL. Real-time checking of electronic anesthesia records for documentation errors and automatically text messaging clinicians improves quality of documentation. Anesth Analg. 2008;106:192–201. doi:10.​1213/​01.​ane.​0000289640.​38523.​bc.PubMedCrossRef
13.
go back to reference Spring SF, Sandberg WS, Anupama S, Walsh JL, Driscoll WD, Raines DE. Automated documentation error detection and notification improves anesthesia billing performance. Anesthesiology. 2007;106:157–63.PubMedCrossRef Spring SF, Sandberg WS, Anupama S, Walsh JL, Driscoll WD, Raines DE. Automated documentation error detection and notification improves anesthesia billing performance. Anesthesiology. 2007;106:157–63.PubMedCrossRef
14.
go back to reference Wax DB, Beilin Y, Levin M, Chadha N, Krol M, Reich DL. The effect of an interactive visual reminder in an anesthesia information management system on timeliness of prophylactic antibiotic administration. Anesth Analg. 2007;104:1462–6.PubMedCrossRef Wax DB, Beilin Y, Levin M, Chadha N, Krol M, Reich DL. The effect of an interactive visual reminder in an anesthesia information management system on timeliness of prophylactic antibiotic administration. Anesth Analg. 2007;104:1462–6.PubMedCrossRef
15.
go back to reference Jacques P, Sanders N, Patel N, Talbot TR, Deshpande JK, Higgins M. Improving timely surgical antibiotic prophylaxis redosing administration using computerized record prompts. Surg Infect. 2005;6:215–21. doi:10.1089/sur.2005.6.215.CrossRef Jacques P, Sanders N, Patel N, Talbot TR, Deshpande JK, Higgins M. Improving timely surgical antibiotic prophylaxis redosing administration using computerized record prompts. Surg Infect. 2005;6:215–21. doi:10.​1089/​sur.​2005.​6.​215.CrossRef
Metadata
Title
Near real-time notification of gaps in cuff blood pressure recordings for improved patient monitoring
Authors
Bala G. Nair
Mayumi Horibe
Shu-Fang Newman
Wei-Ying Wu
Howard A. Schwid
Publication date
01-06-2013
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2013
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-012-9425-2

Other articles of this Issue 3/2013

Journal of Clinical Monitoring and Computing 3/2013 Go to the issue