Abstract

A number of technologies are available for minimally-invasive cardiac output measurement in patients during surgery but remain little used. A system has been developed based on CO2 elimination (VCO2) by the lungs for use in ventilated patients, which can be fully integrated into a modern anesthesia/monitoring platform, and provides semi-automated, continuous breath-by-breath cardiac output monitoring. A prototype measurement system was constructed to measure VCO2 and end-tidal CO2 concentration with each breath. A baseline measurement of non-shunt cardiac output was made during a brief change in ventilator rate, according to the differential CO2 Fick approach. Continuous breath-by-breath monitoring of cardiac output was then performed from measurement of VCO2, using a derivation of the Fick equation applied to pulmonary CO2 elimination. Automated recalibration was done periodically and data was processed and cardiac output displayed in real time. Measurements were compared with simultaneous measurements by bolus thermodilution in 77 patients undergoing cardiac surgery or liver transplantation. Overall mean bias [sd] for agreement in cardiac output measurement was −0.1 [1.2] L/min, percentage error +44.2%, r = 0.92. Concordance in measurement of changes of at least 15% in cardiac output was 80%. The method followed sudden changes in cardiac output due to arrythmias and run onto cardiopulmonary bypass in real time. The accuracy and precision were comparable to other clinical techniques. The method is relatively seamless and largely automated and has potential for continuous, cardiac output monitoring in ventilated patients during anesthesia and critical care.
Appendix
Available only for authorised users
Literature
1.
go back to reference Donati A, Loggi S, Preiser JC, Orsetti G, Munch C, Gabbanelli V, Pelaia P, Pietropaoli P. Goal-directed introperative therapy reduces morbidity and length of hospital stay in high-risk surgical patients. Chest. 2007;132(6):1817–24.PubMedCrossRef Donati A, Loggi S, Preiser JC, Orsetti G, Munch C, Gabbanelli V, Pelaia P, Pietropaoli P. Goal-directed introperative therapy reduces morbidity and length of hospital stay in high-risk surgical patients. Chest. 2007;132(6):1817–24.PubMedCrossRef
2.
go back to reference Chytra I, Pradl R, Bosman R, Pelnář P, Kasal E, Židková A. Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: a randomized controlled trial. Crit Care. 2007;11:R24.PubMedCrossRef Chytra I, Pradl R, Bosman R, Pelnář P, Kasal E, Židková A. Esophageal Doppler-guided fluid management decreases blood lactate levels in multiple-trauma patients: a randomized controlled trial. Crit Care. 2007;11:R24.PubMedCrossRef
3.
go back to reference Bundgaard-Nielsen M, Holte K, Secher NH, Kehlet H. Monitoring of peri-operative fluid administration by individualized goal-directed therapy. Acta Anaesthesiol Scand. 2007;51:331–40.PubMedCrossRef Bundgaard-Nielsen M, Holte K, Secher NH, Kehlet H. Monitoring of peri-operative fluid administration by individualized goal-directed therapy. Acta Anaesthesiol Scand. 2007;51:331–40.PubMedCrossRef
4.
go back to reference Chappell D, Jacob M, Hofmann-Kiefer K, Conzen P, Rehm M. A rational approach to perioperative fluid management. Anesthesiology. 2008;109(4):723–40.PubMedCrossRef Chappell D, Jacob M, Hofmann-Kiefer K, Conzen P, Rehm M. A rational approach to perioperative fluid management. Anesthesiology. 2008;109(4):723–40.PubMedCrossRef
5.
go back to reference Abbas SM, Hill AG. Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia. 2008;63:44–51.PubMedCrossRef Abbas SM, Hill AG. Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery. Anaesthesia. 2008;63:44–51.PubMedCrossRef
6.
go back to reference Funk DJ, Moretti EW, Gan TJ. Minimally invasive cardiac output monitoring in the perioperative setting. Anesth Analg. 2009;108:887–97.PubMedCrossRef Funk DJ, Moretti EW, Gan TJ. Minimally invasive cardiac output monitoring in the perioperative setting. Anesth Analg. 2009;108:887–97.PubMedCrossRef
7.
go back to reference Blomqvist H, Frostell C, Hedenstierna G. A non-invasive technique for measurement of lung perfusion. Intensive Care Med. 1986;12:172–8. Blomqvist H, Frostell C, Hedenstierna G. A non-invasive technique for measurement of lung perfusion. Intensive Care Med. 1986;12:172–8.
8.
go back to reference Capek JM, Roy RJ. Noninvasive measurement of cardiac output during partial CO2 rebreathing. IEEE Trans Biomed Eng. 1988;35:653–61.PubMedCrossRef Capek JM, Roy RJ. Noninvasive measurement of cardiac output during partial CO2 rebreathing. IEEE Trans Biomed Eng. 1988;35:653–61.PubMedCrossRef
9.
go back to reference Yem JS, Tang Y, Turner MJ, Baker AB. Sources of error in noninvasive pulmonary blood flow measurements by partial rebreathing: a computer model study. Anesthesiology. 2003;98(4):881–7.PubMedCrossRef Yem JS, Tang Y, Turner MJ, Baker AB. Sources of error in noninvasive pulmonary blood flow measurements by partial rebreathing: a computer model study. Anesthesiology. 2003;98(4):881–7.PubMedCrossRef
10.
go back to reference Miller TE, Roche AM, Gan TJ. Poor adoption of hemodynamic optimization during major surgery: are we practicing substandard care? Anesth Analg. 2011;112(6):1274–6.PubMedCrossRef Miller TE, Roche AM, Gan TJ. Poor adoption of hemodynamic optimization during major surgery: are we practicing substandard care? Anesth Analg. 2011;112(6):1274–6.PubMedCrossRef
11.
go back to reference Gedeon A, Forslund L, Hedenstierna G, Romano E. A new method for noninvasive bedside determination of pulmonary blood flow. Med Biol Eng Comput. 1980;18:411–8.PubMedCrossRef Gedeon A, Forslund L, Hedenstierna G, Romano E. A new method for noninvasive bedside determination of pulmonary blood flow. Med Biol Eng Comput. 1980;18:411–8.PubMedCrossRef
12.
go back to reference Peyton P, Thompson D, Junor P. Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick method. J Clin Monit Comput. 2008;22(4):285–92.PubMedCrossRef Peyton P, Thompson D, Junor P. Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick method. J Clin Monit Comput. 2008;22(4):285–92.PubMedCrossRef
13.
go back to reference Botero M, Kirby D, Lobato E, Staples E, Gravenstein N. Measurement of cardiac output before and after cardiopulmonary bypass: comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J Cardiothorac Vasc Anesth. 2004;18(5):563–72.PubMedCrossRef Botero M, Kirby D, Lobato E, Staples E, Gravenstein N. Measurement of cardiac output before and after cardiopulmonary bypass: comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J Cardiothorac Vasc Anesth. 2004;18(5):563–72.PubMedCrossRef
14.
go back to reference Peyton P, Chong S. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113(5):1220–35.PubMedCrossRef Peyton P, Chong S. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113(5):1220–35.PubMedCrossRef
15.
go back to reference Noguchi H, Ogushi Y, Yoshiya I, Itakura N, Yamabayashi H. Breath-by-breath \( \dot{V}_{{{\text{CO}}_{2} }} \) and \( \dot{V}_{{{\text{O}}_{2} }} \) require compensation for transport delay and dynamic response. J Appl Physiol Respir Environ Exerc Physiol. 1981;51(6):1662–1675. Noguchi H, Ogushi Y, Yoshiya I, Itakura N, Yamabayashi H. Breath-by-breath \( \dot{V}_{{{\text{CO}}_{2} }} \) and \( \dot{V}_{{{\text{O}}_{2} }} \) require compensation for transport delay and dynamic response. J Appl Physiol Respir Environ Exerc Physiol. 1981;51(6):1662–1675.
16.
go back to reference Kelman GR. Digital computer subroutine for the conversion of oxygen tension into saturation. J Appl Physiol. 1966;21(4):1375–6.PubMed Kelman GR. Digital computer subroutine for the conversion of oxygen tension into saturation. J Appl Physiol. 1966;21(4):1375–6.PubMed
17.
go back to reference Kelman GR. Digital computer procedure for the conversion of PCO2 into blood CO2 content. Respir Physiol. 1967;3:111–5.PubMedCrossRef Kelman GR. Digital computer procedure for the conversion of PCO2 into blood CO2 content. Respir Physiol. 1967;3:111–5.PubMedCrossRef
18.
go back to reference Peyton P, Robinson G, Thompson B. The effect of ventilation-perfusion inhomogeneity and nitrous oxide on oxygenation in anesthesia: physiological modeling of gas exchange. J Appl Physiol. 2001;91:17–25.PubMed Peyton P, Robinson G, Thompson B. The effect of ventilation-perfusion inhomogeneity and nitrous oxide on oxygenation in anesthesia: physiological modeling of gas exchange. J Appl Physiol. 2001;91:17–25.PubMed
19.
go back to reference Räsänen J, Downs JB, Hodges MR. Continuous monitoring of gas exchange and oxygen use with dual oximetry. J Clin Anesth. 1988;1(1):3–8.PubMedCrossRef Räsänen J, Downs JB, Hodges MR. Continuous monitoring of gas exchange and oxygen use with dual oximetry. J Clin Anesth. 1988;1(1):3–8.PubMedCrossRef
20.
go back to reference Cohen JB, Camporesi EM, Schweiger HW. Respiratory monitoring. In: Wilson WC, Grande CM, Hoyt DB, editors. Trauma, critical care. Vol II. Informa healthcare: New York; 2007. Ch 8. p. 150 Cohen JB, Camporesi EM, Schweiger HW. Respiratory monitoring. In: Wilson WC, Grande CM, Hoyt DB, editors. Trauma, critical care. Vol II. Informa healthcare: New York; 2007. Ch 8. p. 150
21.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307–10.CrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307–10.CrossRef
22.
go back to reference Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571–82.PubMedCrossRef Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571–82.PubMedCrossRef
23.
go back to reference Streiner DL, Norman GR. Health measurement scales. A practical guide to their development and use. 2nd edn. Oxford: Oxford Medical publications; 1995. Ch 8. pp. 104–26. Streiner DL, Norman GR. Health measurement scales. A practical guide to their development and use. 2nd edn. Oxford: Oxford Medical publications; 1995. Ch 8. pp. 104–26.
24.
go back to reference Perrino AC Jr, Harris SN, Luther MA. Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution. Anesthesiology. 1998;89:350–7.PubMedCrossRef Perrino AC Jr, Harris SN, Luther MA. Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution. Anesthesiology. 1998;89:350–7.PubMedCrossRef
25.
go back to reference Critchley LA, Lee A, Ho AM-H. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180–92.PubMedCrossRef Critchley LA, Lee A, Ho AM-H. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180–92.PubMedCrossRef
26.
go back to reference Mahutte CK, Jaffe MB, Sassoon CS, Wong DH. Cardiac output from carbon dioxide production and arterial and venous oximetry. Crit Care Med. 1991;19(10):1270–7.PubMedCrossRef Mahutte CK, Jaffe MB, Sassoon CS, Wong DH. Cardiac output from carbon dioxide production and arterial and venous oximetry. Crit Care Med. 1991;19(10):1270–7.PubMedCrossRef
27.
go back to reference Davies GG, Jebson PJ, Glasgow BM, Hess DR. Continuous Fick cardiac output compared to thermodilution cardiac output. Crit Care Med. 1986;14(10):881–5.PubMedCrossRef Davies GG, Jebson PJ, Glasgow BM, Hess DR. Continuous Fick cardiac output compared to thermodilution cardiac output. Crit Care Med. 1986;14(10):881–5.PubMedCrossRef
28.
go back to reference Trevino RP, Bisera J, Weil MH, Rackow EC, Grundler WG. End-tidal CO2 as a guide to successful cardiopulmonary resuscitation: a preliminary report. Crit Care Med. 1985;13:910–1.PubMedCrossRef Trevino RP, Bisera J, Weil MH, Rackow EC, Grundler WG. End-tidal CO2 as a guide to successful cardiopulmonary resuscitation: a preliminary report. Crit Care Med. 1985;13:910–1.PubMedCrossRef
29.
go back to reference Garnett A, Ornato JP, Gonzalez ER, Johnson B. End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation. JAMA. 1987;257:512–5.PubMedCrossRef Garnett A, Ornato JP, Gonzalez ER, Johnson B. End-tidal carbon dioxide monitoring during cardiopulmonary resuscitation. JAMA. 1987;257:512–5.PubMedCrossRef
30.
go back to reference Falk JL, Rackow EC, Weil MH. End-tidal carbon dioxide concentration during cardiopulmonary resuscitation. NEJM. 1988;318:607–11.PubMedCrossRef Falk JL, Rackow EC, Weil MH. End-tidal carbon dioxide concentration during cardiopulmonary resuscitation. NEJM. 1988;318:607–11.PubMedCrossRef
31.
go back to reference Vannucci A, Krejci V, Kangrga I. Performance of Vigileo and LiDCOplus cardiac output monitors during a prolonged cardiac arrest and resuscitation. Eur J Anaesthesiol. 2009;26:885–7.PubMedCrossRef Vannucci A, Krejci V, Kangrga I. Performance of Vigileo and LiDCOplus cardiac output monitors during a prolonged cardiac arrest and resuscitation. Eur J Anaesthesiol. 2009;26:885–7.PubMedCrossRef
32.
go back to reference Nishiwaki C, Kotake Y, Yamada T, Nagata H, Tagawa M, Takeda J. Response time of different methods of cardiac output monitoring during cardiopulmonary resuscitation and recovery. J Cardiothorac Vasc Anesth. 2010;24(2):306–8.PubMedCrossRef Nishiwaki C, Kotake Y, Yamada T, Nagata H, Tagawa M, Takeda J. Response time of different methods of cardiac output monitoring during cardiopulmonary resuscitation and recovery. J Cardiothorac Vasc Anesth. 2010;24(2):306–8.PubMedCrossRef
33.
go back to reference Isserles SA, Breen PH. Can changes in end-tidal PCO2 measure changes in cardiac output? Anesth Analg. 1991;73:808–14.PubMedCrossRef Isserles SA, Breen PH. Can changes in end-tidal PCO2 measure changes in cardiac output? Anesth Analg. 1991;73:808–14.PubMedCrossRef
34.
go back to reference Breen PH. How do changes in exhaled CO2 measure changes in cardiac output? A numerical analysis model. J Clin Monit Comput. 2010;24:413–9.PubMedCrossRef Breen PH. How do changes in exhaled CO2 measure changes in cardiac output? A numerical analysis model. J Clin Monit Comput. 2010;24:413–9.PubMedCrossRef
35.
go back to reference Ganong WF. Review of medical physiology. 16th ed. East Norwalk, CT: Appleton and Lange; 1993. p. 256. Ganong WF. Review of medical physiology. 16th ed. East Norwalk, CT: Appleton and Lange; 1993. p. 256.
Metadata
Title
Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography
Author
Philip J. Peyton
Publication date
01-04-2012
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2012
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-012-9342-4

Other articles of this Issue 2/2012

Journal of Clinical Monitoring and Computing 2/2012 Go to the issue