Skip to main content
Top
Published in: Documenta Ophthalmologica 3/2010

01-06-2010 | TECHNICAL NOTE

Some thoughts on the interpretation of steady-state evoked potentials

Author: Sven P. Heinrich

Published in: Documenta Ophthalmologica | Issue 3/2010

Login to get access

Abstract

Steady-state evoked potentials are popular due to their easy analysis in frequency space and the availability of methods for objective response detection. However, the interpretation of steady-state responses can be challenging due to their origin as a sequence of responses to single stimuli. In the present paper, issues of signal extinction and some characteristics of higher harmonics are illustrated based on simple model data for those readers who do not regularly hobnob with frequency-space representations of data. It is important to realize that the absence of a steady-state response does not prove the lack of neural activity. For the same underlying reasons, namely constructive and destructive superposition of individual responses, comparisons of amplitudes between experimental conditions are prone to inaccuracies. Thus, before inferring physiology from steady-state responses, one should consider an alternative explanation in terms of signal composition.
Footnotes
1
“Identical” refers to the mass responses as seen in the EEG. Responses that are macroscopically indistinguishable might nevertheless originate from different groups of neurons.
 
Literature
1.
go back to reference Norcia AM, Sato T, Shinn P, Mertus J (1986) Methods for the identification of evoked response components in the frequency and combined time/frequency domains. Electroencephalogr Clin Neurophysiol 65:212–226CrossRefPubMed Norcia AM, Sato T, Shinn P, Mertus J (1986) Methods for the identification of evoked response components in the frequency and combined time/frequency domains. Electroencephalogr Clin Neurophysiol 65:212–226CrossRefPubMed
2.
go back to reference Victor JD, Mast J (1990) A new statistic for steady-state evoked potentials. Electroenceph Clin Neurophysiol 78:378–388CrossRef Victor JD, Mast J (1990) A new statistic for steady-state evoked potentials. Electroenceph Clin Neurophysiol 78:378–388CrossRef
3.
go back to reference Dobie RA, Wilson MJ (1993) Objective response detection in the frequency domain. Electroencephalogr Clin Neurophysiol 88:516–524CrossRefPubMed Dobie RA, Wilson MJ (1993) Objective response detection in the frequency domain. Electroencephalogr Clin Neurophysiol 88:516–524CrossRefPubMed
4.
go back to reference Liavas AP, Moustakides GV, Henning G, Psarakis EZ, Husar P (1998) A periodogram-based method for the detection of steady-state visually evoked potentials. IEEE Trans Biomed Eng 45:242–248CrossRefPubMed Liavas AP, Moustakides GV, Henning G, Psarakis EZ, Husar P (1998) A periodogram-based method for the detection of steady-state visually evoked potentials. IEEE Trans Biomed Eng 45:242–248CrossRefPubMed
5.
go back to reference Meigen T, Bach M (1999) On the statistical significance of electrophysiological steady-state responses. Doc Ophthalmol 98:207–232CrossRefPubMed Meigen T, Bach M (1999) On the statistical significance of electrophysiological steady-state responses. Doc Ophthalmol 98:207–232CrossRefPubMed
6.
go back to reference Müller MM, Malinowski P, Gruber T, Hillyard SA (2003) Sustained division of the attentional spotlight. Nature 424:309–312CrossRefPubMed Müller MM, Malinowski P, Gruber T, Hillyard SA (2003) Sustained division of the attentional spotlight. Nature 424:309–312CrossRefPubMed
7.
go back to reference Bach M, Meigen T (1999) Do’s and don’ts in Fourier analysis of steady-state potentials. Doc Ophthalmol 99:69–82CrossRefPubMed Bach M, Meigen T (1999) Do’s and don’ts in Fourier analysis of steady-state potentials. Doc Ophthalmol 99:69–82CrossRefPubMed
8.
go back to reference Strasburger H, Scheidler W, Rentschler I (1988) Amplitude and phase characteristics of the steady-state visual evoked potential. Appl Optics 27:1069–1088CrossRef Strasburger H, Scheidler W, Rentschler I (1988) Amplitude and phase characteristics of the steady-state visual evoked potential. Appl Optics 27:1069–1088CrossRef
9.
go back to reference Bach M, Maurer JP, Wolf ME (2008) VEP-based acuity assessment in normal vision, artificially degraded vision, and in patients. Brit J Ophthalmol 92:396–403CrossRef Bach M, Maurer JP, Wolf ME (2008) VEP-based acuity assessment in normal vision, artificially degraded vision, and in patients. Brit J Ophthalmol 92:396–403CrossRef
10.
go back to reference Heinrich SP, Bach M (2001) Adaptation dynamics in pattern-reversal visual evoked potentials. Doc Ophthalmol 102:141–156CrossRefPubMed Heinrich SP, Bach M (2001) Adaptation dynamics in pattern-reversal visual evoked potentials. Doc Ophthalmol 102:141–156CrossRefPubMed
11.
go back to reference Strasburger H (1987) The analysis of steady state evoked potentials revisited. Clin Vision Sci 1:245–256 Strasburger H (1987) The analysis of steady state evoked potentials revisited. Clin Vision Sci 1:245–256
12.
go back to reference Norcia AM, Tyler CW, Hamer RD, Wesemann W (1989) Measurement of spatial contrast sensitivity with the swept contrast VEP. Vision Res 29:627–637CrossRefPubMed Norcia AM, Tyler CW, Hamer RD, Wesemann W (1989) Measurement of spatial contrast sensitivity with the swept contrast VEP. Vision Res 29:627–637CrossRefPubMed
13.
go back to reference Lütkenhöner B (1991) Theoretical considerations on the detection of evoked responses by means of the Rayleigh test. Acta Otolaryngol (Stockh) Suppl 491:52–60CrossRef Lütkenhöner B (1991) Theoretical considerations on the detection of evoked responses by means of the Rayleigh test. Acta Otolaryngol (Stockh) Suppl 491:52–60CrossRef
14.
go back to reference Simpson DM (2000) Objective response detection in an electroencephalogram during somatosensory stimulation. Ann Biomed Eng 28:691–698CrossRefPubMed Simpson DM (2000) Objective response detection in an electroencephalogram during somatosensory stimulation. Ann Biomed Eng 28:691–698CrossRefPubMed
15.
go back to reference Heinrich SP (2009) Permutation-based significance tests for multi-harmonic steady-state evoked potentials. IEEE Trans Biomed Eng 56:534–537CrossRefPubMed Heinrich SP (2009) Permutation-based significance tests for multi-harmonic steady-state evoked potentials. IEEE Trans Biomed Eng 56:534–537CrossRefPubMed
16.
go back to reference Felix LB, Miranda de Sa AMFL, Infantosi AFC, Yehia HC (2007) Multivariate objective response detectors (MORD): statistical tools for multichannel EEG analysis during rhythmic stimulation. Ann Biomed Eng 35:443–452CrossRefPubMed Felix LB, Miranda de Sa AMFL, Infantosi AFC, Yehia HC (2007) Multivariate objective response detectors (MORD): statistical tools for multichannel EEG analysis during rhythmic stimulation. Ann Biomed Eng 35:443–452CrossRefPubMed
17.
go back to reference Mast J, Victor JD (1991) Fluctuations of steady-state veps: interaction of driven evoked potentials and the eeg. Electroencephalogr Clin Neurophysiol 78:389–401CrossRefPubMed Mast J, Victor JD (1991) Fluctuations of steady-state veps: interaction of driven evoked potentials and the eeg. Electroencephalogr Clin Neurophysiol 78:389–401CrossRefPubMed
18.
go back to reference Delgado RE, Ozdamar O (2004) Deconvolution of evoked responses obtained at high stimulus rates. J Acoust Soc Am 115:1242–1251CrossRefPubMed Delgado RE, Ozdamar O (2004) Deconvolution of evoked responses obtained at high stimulus rates. J Acoust Soc Am 115:1242–1251CrossRefPubMed
19.
go back to reference Jewett DL, Caplovitz G, Baird B, Trumpis M, Olson MP, Larson-Prior LJ (2004) The use of QSD (q-sequence deconvolution) to recover superposed, transient evoked-responses. Clin Neurophysiol 115:2754–2775CrossRefPubMed Jewett DL, Caplovitz G, Baird B, Trumpis M, Olson MP, Larson-Prior LJ (2004) The use of QSD (q-sequence deconvolution) to recover superposed, transient evoked-responses. Clin Neurophysiol 115:2754–2775CrossRefPubMed
20.
go back to reference Bohórquez J, Özdamar Ö, Açıkgöz N, Yavuz E (2007) Methodology to estimate the transient evoked responses for the generation of steady state responses. Conf Proc IEEE Eng Med Biol Soc 2007:2444–2447PubMed Bohórquez J, Özdamar Ö, Açıkgöz N, Yavuz E (2007) Methodology to estimate the transient evoked responses for the generation of steady state responses. Conf Proc IEEE Eng Med Biol Soc 2007:2444–2447PubMed
21.
go back to reference Mell D, Bach M, Heinrich SP (2008) Fast stimulus sequences improve the efficiency of event-related potential P300 recordings. J Neurosci Meth 174:259–264CrossRef Mell D, Bach M, Heinrich SP (2008) Fast stimulus sequences improve the efficiency of event-related potential P300 recordings. J Neurosci Meth 174:259–264CrossRef
22.
go back to reference Sutter EE, Tran D (1992) The field topography of ERG components in man—I. The photopic luminance response. Vision Res 32:433–446CrossRef Sutter EE, Tran D (1992) The field topography of ERG components in man—I. The photopic luminance response. Vision Res 32:433–446CrossRef
23.
go back to reference Smith SW (1999) The Scientist and Engineer’s Guide to Digital Signal Processing. 2nd edn., California Technical Publishing, San Diego, CA Smith SW (1999) The Scientist and Engineer’s Guide to Digital Signal Processing. 2nd edn., California Technical Publishing, San Diego, CA
24.
go back to reference Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M (2009) ISCEV standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M (2009) ISCEV standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed
Metadata
Title
Some thoughts on the interpretation of steady-state evoked potentials
Author
Sven P. Heinrich
Publication date
01-06-2010
Publisher
Springer-Verlag
Published in
Documenta Ophthalmologica / Issue 3/2010
Print ISSN: 0012-4486
Electronic ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-010-9212-7

Other articles of this Issue 3/2010

Documenta Ophthalmologica 3/2010 Go to the issue